NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

Similar documents
NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

DIVISION 10 SPECIALTIES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

ASI Guide Specification

Ship Program Washroom Accessories. Keys. Combination Towel / Waste

BRADLEY COMMERCIAL TOILET ACCESSORIES


Bobrick - Washroom Accessories. Conversion Chart

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

Gen 4 New Build TurningPointS 2.0

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

GUIDE SPECIFICATION Los Angeles World Airports SECTION TOILET COMPARTMENTS

ROVAL COLLECTION PAPER TOWEL DISPENSERS TOILET TISSUE DISPENSERS MIRRORS AUTOMATIC HAND DRYERS

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

TrimLineSeries offers a sleek, minimalist design manufactured with satin-finish Type 304 stainless steel. This range of models features 90-degree

ROVAL COLLECTION PAPER TOWEL DISPENSERS TOILET TISSUE DISPENSERS MIRRORS AUTOMATIC HAND DRYERS

PAPER TOWEL DISPENSERS

Gen 4.5 New Build Palettes

A. Section includes ground-mounted flagpoles made from aluminum.

SECTION ELECTRIC WATER HEATERS

WASHROOM ACCESSORIES

AMERICAN SPECIALTIES INC.

SECTION IDENTIFYING DEVICES

A. Curtains: Provide curtain fabrics with the following characteristics:

PRICE LISTS EFFECTIVE JANUARY 1, 2018 WASHROOM ACCESSORIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION Overhead Coiling Doors

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION FIRE EXTINGUISHER CABINETS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Washroom Accessories 30857eng_09.indd 1 4/5/16 9:36 AM

BATHROOM ACCESSORIES & SHELVING

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

C. Samples for Initial Selection: For units with factory-applied color finishes.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

16028 September 23, 2016

SECTION GYPSUM PLASTER

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

Willoughby Industries - Security Products

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SecuringHospitals.com presents... SUICIDE RESISTANT PRODUCTS. ...helping you keep your patients and facility safe. SecuringHospitals.

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION ELECTRIC WATER HEATERS

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION DUCTWORK

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION DOMESTIC WATER HEATERS

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Construction Standards Page

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

SPECIAL SPECIFICATION 2242 LATH, STUCCO AND PLASTER

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

A. Section Joint Sealants: Seal fixtures to walls and floors.

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

EN. Washroom Accessories

Barben. Washroom Accessories. www. barben.com. au

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

F & S Caretaking Department Design Standards For New or Renovated U of T Premises February 2015

Restroom Accessory Catalog

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

A. This Section includes the following emergency plumbing fixtures:

Partitions. Accessories. Lockers. No-Touch Washroom Accessories

SECTION PLUMBING FIXTURES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

SECTION AIR DUCT ACCESSORIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Coat Racks / Floor Racks / Hooks / Hangers Hook Panels / Concealed Wardrobes

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Restroom Accessory Catalog

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

CLINICAL SERVICES ADMINISTRATION (214)

GSL Artira Inclined Lift Specifications L DS Section

SECTION DRY-PIPE SPRINKLER SYSTEMS

University of Rochester October 17, 2008 Brooks Landing Business Center

Bath Hardware Jeffrey Alexander Collections Viora Talara Trevi Tahoe

FIRE SUPPRESSION SPRINKLER SYSTEM

A. Provide products and workmanship in accordance to: (Where applicable)

Transcription:

SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Public-use washroom accessories. 2. Warm-air dryers. 3. Childcare accessories. 4. Under lavatory guards. 5. Custodial accessories. 1.3 DELIVERY, STORAGE, AND HANDLING A. Receive Owner provided products and provide a secure lock-up these items. 1.4 COORDINATION A. Coordinate accessory locations with other work to prevent interference with clearances required for access by people with disabilities, and for proper installation, adjustment, operation, cleaning, and servicing of accessories. B. Deliver inserts and anchoring devices set into concrete or masonry as required to prevent delaying the Work. C. Owner Provided Products: 1. Coordinate obtaining Owner provided products to allow for Owner activities of purchasing and obtaining the product. 2. Provide quantities of each product required to the Facilities Project Manager. 3. Coordinate receipt and installation of the Owner provided products so that construction activities remain on schedule. 1.5 ACTION SUBMITTALS A. Product Data: For each type of product. 1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes. TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-1

2. Include anchoring and mounting requirements, including requirements for cutouts in other work and substrate preparation. 3. Include electrical characteristics. B. Product Schedule: Indicating types, quantities, sizes, and installation locations by room of each accessory required. 1. Identify locations using room designations indicated. 2. Identify accessories using designations indicated. 1.6 INFORMATIONAL SUBMITTALS A. Sample Warranty: For manufacturer's special warranty. 1.7 CLOSEOUT SUBMITTALS A. Maintenance Data: For accessories to include in maintenance manuals. 1.8 WARRANTY A. Manufacturer's Special Warranty for Mirrors: Manufacturer agrees to repair or replace mirrors that fail in materials or workmanship within specified warranty period. 1. Failures include, but are not limited to, visible silver spoilage defects. 2. Warranty Period: 15 years from date of Substantial Completion. PRODUCTS 2.1 OWNER-FURNISHED MATERIALS A. Owner-Furnished Materials: Paper Towel Dispensers, Soap Dispensers, Toilet Paper Dispensers, and Sanitary Disposal, 2.2 PERFORMANCE REQUIREMENTS A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 2.3 PUBLIC-USE WASHROOM ACCESSORIES A. Source Limitations: Obtain public-use washroom accessories from single source from single manufacturer. B. Sanitary Napkin/Tampon Vendor 1. Basis of Design: Bobrick Washroom Equipment, Inc.; B2706 25 or equal. a. Mounting: Surface b. Material and Finish: Stainless Steel, type 304, satin finish on all exposed surfaces TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-2

C. Grab Bar: c. Cost of Product: Free 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 2. Mounting: Flanges with concealed fasteners. 3. Material: Stainless steel, 0.05 inch (1.3 mm) thick. a. Finish: Smooth, No. 4 finish (satin). 4. Outside Diameter: 1-1/2 inches (38 mm). 5. Configuration and Length: As indicated on Drawings. D. Mirror Unit: 1. Basis-of-Design: Bobrick Washroom Equipment, Inc.; B-290 Series or subject to compliance with requirements, provide products by one of the following: 2. Frame: Stainless-steel angle, 0.05 inch (1.3 mm) thick. a. Corners: Welded and ground smooth. 3. Hangers: Produce rigid, tamper- and theft-resistant installation, using method indicated below. a. Wall bracket of galvanized steel, equipped with concealed locking devices requiring a special tool to remove. 4. Size: As indicated on Drawings. 2.4 PUBLIC-USE SHOWER ROOM ACCESSORIES A. Source Limitations: Obtain public-use shower room accessories from single source from single manufacturer. B. Shower Curtain Rod: 1. Basis-of-Design: Bobrick Washroom Equipment, Inc.; B-207 or subject to compliance with requirements, provide products by one of the following: TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-3

2. Description: 1-inch (25.4-mm) OD; fabricated from nominal 0.0375-inch- (0.95-mm-) thick stainless steel. 3. Mounting Flanges: Stainless-steel flanges designed for concealed fasteners. 4. Finish: Stainless steel, No. 4 finish (satin). C. Shower Curtain: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 2. Size: Minimum 6 inches (152 mm) wider than opening by 72 inches (1828 mm) high. 3. Material: Nylon-reinforced vinyl, minimum 10 oz. (284 g) or 0.008-inch- (0.2-mm-) thick vinyl, with integral antibacterial agent. 4. Color: <Insert color>. 5. Grommets: Corrosion resistant at minimum 6 inches (152 mm) o.c. through top hem. 6. Shower Curtain Hooks: Chrome-plated or stainless-steel, spring wire curtain hooks with snap fasteners, sized to accommodate specified curtain rod. Provide one hook per curtain grommet. D. Folding Shower Seat: 1. Basis-of-Design: Bobrick Washroom Equipment, Inc.; B-5181 or subject to compliance with requirements, provide products by one of the following: 2. Description: Reversible folding shower seat shall have a frame constructed of type-304, satin-finish stainless steel that consists of 16-gauge, 1-1/4'' square tubing and 18-gauge, 1'' diameter seamless tubing. Seat shall be one-piece, 1/2" thick, solid phenolic with mattefinish, antique white-colored, melamine surfaces, and black phenolic-resin core; secured to frame with stainless steel carriage bolts and acorn nuts. Seat shall be reversible for leftor right-hand installation in the field. Shower seat shall be equipped with two 3'' diameter mounting flanges constructed of type-304, 3/16'' thick, satin-finish stainless steel; a guide bracket constructed of type-304, 16-gauge, satin-finish stainless steel; and a spring constructed of type-301, 24-gauge stainless steel that is spot-welded to a baseplate of type-304, heavygauge stainless steel. Seat shall remain in upright position when not in use. 3. Configuration: L-shaped seat, designed for wheelchair access. 4. Seat: Phenolic or polymeric composite of slat-type or one-piece construction in color as selected by Architect. 5. Mounting Mechanism: Stainless steel, No. 4 finish (satin). TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-4

E. Robe Hook: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 2. Description: Single-prong unit. 3. Material and Finish: Stainless steel, No. 4 finish (satin). 2.5 WARM-AIR DRYERS A. Source Limitations: Obtain warm-air dryers from single source from single manufacturer. B. High-Speed Warm-Air Dryer: 1. Manufacturers: Subject to compliance with requirements, provide one of the following products: a. Dyson, Airblade V b. Excel Dryer Inc., XLERATOReco 2. Description: High-speed, warm-air hand dryer for rapid hand drying. 3. Mounting: [Recessed] [Semirecessed], with low-profile design. 4. Operation: Electronic-sensor activated with operation time of 10 to 20 seconds. 5. Cover Material and Finish: Cast iron, with enamel finish in color selected by Architect. 6. Electrical Requirements: <Insert electrical requirements>. 2.6 CHILDCARE ACCESSORIES A. Source Limitations: Obtain childcare accessories from single source from single manufacturer. B. Diaper-Changing Station: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. American Specialties, Inc. b. GAMCO Specialty Accessories; a division of Bobrick. c. Koala Kare Products. d. Or Equal. 2. Description: Horizontal unit that opens by folding down from stored position and with childprotection strap. a. Engineered to support minimum of 250-lb (113-kg) static load when opened. 3. Mounting: [Surface mounted, with unit projecting not more than 4 inches (100 mm) from wall when closed] [Semirecessed, with unit projecting not more than 1 inch (25 mm) from wall when closed]. TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-5

4. Operation: By pneumatic shock-absorbing mechanism. 5. Material and Finish: Stainless steel, No. 4 finish (satin), exterior shell with rounded plastic corners; HDPE interior in manufacturer's standard color. 6. Liner Dispenser: Built in. 7. Manufacturer's name plate shall not be visible once installed. 2.7 UNDER LAVATORY GUARDS A. Under lavatory Guard: 1. Description: Insulating pipe covering for supply and drain piping assemblies that prevents direct contact with and burns from piping; allow service access without removing coverings. 2. Material and Finish: Antimicrobial, molded plastic, white. 2.8 CUSTODIAL ACCESSORIES A. Source Limitations: Obtain custodial accessories from single source from single manufacturer. B. Mop and Broom Holder: 1. Basis-of-Design: Bobrick Washroom Equipment, Inc.; B-239 or subject to compliance with requirements, provide products by one of the following: 2. Description: Utility shelf with mop/broom holders and rag hooks shall be type-304 stainless steel with all-welded construction; exposed surfaces shall have satin finish. Shelf shall be 18 gauge, 8" deep with 3/4" return edges, and shall have front edge hemmed for safety. 3. Length: 34 inches. 4. Hooks: Four. 5. Mop/Broom Holders: Three, spring-loaded, rubber hat, cam type. 6. Material and Finish: Stainless steel, No. 4 finish (satin). a. Shelf: Not less than nominal 0.05-inch- (1.3-mm-) thick stainless steel. 2.9 MATERIALS A. Stainless Steel: ASTM A 666, Type 304, 0.031-inch (0.8-mm) minimum nominal thickness unless otherwise indicated. B. Brass: ASTM B 19, flat products; ASTM B 16/B 16M, rods, shapes, forgings, and flat products with finished edges; or ASTM B 30, castings. C. Steel Sheet: ASTM A 1008/A 1008M, Designation CS (cold rolled, commercial steel), 0.036-inch (0.9-mm) minimum nominal thickness. D. Galvanized-Steel Sheet: ASTM A 653/A 653M, with G60 (Z180) hot-dip zinc coating. E. Galvanized-Steel Mounting Devices: ASTM A 153/A 153M, hot-dip galvanized after fabrication. TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-6

F. Fasteners: Screws, bolts, and other devices of same material as accessory unit and tamper-andtheft resistant where exposed, and of galvanized steel where concealed. G. Chrome Plating: ASTM B 456, Service Condition Number SC 2 (moderate service). H. Mirrors: ASTM C 1503, Mirror Glazing Quality, clear-glass mirrors, nominal 6.0 mm thick. 2.10 FABRICATION A. General: Fabricate units with tight seams and joints, and exposed edges rolled. Hang doors and access panels with full-length, continuous hinges. Equip units for concealed anchorage and with corrosion-resistant backing plates. B. Keys: Provide universal keys for internal access to accessories for servicing and resupplying. Provide minimum of <Insert number> keys to Owner's representative. EXECUTION 3.1 INSTALLATION A. Install accessories according to manufacturers' written instructions, using fasteners appropriate to substrate indicated and recommended by unit manufacturer. Install units level, plumb, and firmly anchored in locations and at heights indicated. B. Install all Owner provided products according to manufacturers' written instructions, using fasteners appropriate to substrate indicated and recommended by unit manufacturer. Install units level, plumb, and firmly anchored in locations and at heights indicated. C. Grab Bars: Install to withstand a downward load of at least 250 lbf (1112 N), when tested according to ASTM F 446. 3.2 ADJUSTING AND CLEANING A. Adjust accessories for unencumbered, smooth operation. Replace damaged or defective items. B. Remove temporary labels and protective coatings. C. Clean and polish exposed surfaces according to manufacturer's written instructions. END OF SECTION 10 2800 TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-7

THIS PAGE IS INTENTIONALLY LEFT BLANK TOILET, BATH, AND LAUNDRY ACCESSORIES 10 2800-8