CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027 fan heater prevents the formation of condensation and ensures an even temperature in enclosures. The integrated thermostat is used to set the desired temperature while the high performance axial fan provides forced air circulation. The CR 027 is also available with a continuously running fan (when powered). 3.94 (100 mm) 6.5 (165 mm) 5 (128 mm) 4.8 (124 mm) Wiring note: Only connect the and 1 terminals - 2 is not used and Grounding is not required Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) see table below 2-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max.. plastic, U 94V-0, light grey Optical indicator thermostat control light Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 6.5 x 3.94 x 5.0 (165 x 100 x 128 mm) Approvals U File o. E204590 Heating Power / Ambient Temperature (@ 50 Hz) Heating Power / Ambient Temperature (@ 60 Hz) 900 850 800 750 700 650 600 550 500 450 650W 550W -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Temperature 400-40 C C -20 C 00 C 20 C 40 40 C -40 F F -4 F F 32 F F 68 F F 104 104 F Temperature Part o. Heating capacity 1) (@ 50 Hz) Heating capacity 1) (@ 60 Hz) Operating voltage Max. current (inrush) Air flow, free blowing Thermostat setting range Weight (approx.) 02700.0-00 475 W 550 W AC 220-240 V 11.0 A 20 cfm (35 m³/h) 0 to 60 C 2.0 lbs. (0.9 kg ) 02701.0-00 550 W 650 W AC 220-240 V 13.0 A 26 cfm (45 m³/h) 0 to 60 C 2.4 lbs (1.1 kg) 02700.9-00 400 W 550 W AC 100-120 V 14.0 A 20 cfm (35 m³/h) 32 to 140 F 2.0 lbs. (0.9 kg ) 02701.9-00 510 W 650 W AC 100-120 V 15.0 A 26 cfm (45 m³/h) 32 to 140 F 2.4 lbs (1.1 kg) 1) at 68 F (20 C) ambient temperature
30 CR 030 Foot-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat Double insulated plastic housing The compact CR 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DI rail mount, the CR 130 fan heater is recommended. 4.1 (105 mm) high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, clamping torque 0.8 m max. Mounting M5 screws (not included) horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 5.7 x 6.6 (100 x 145 x 168 mm) Weight approx. 3.1 lbs. (1.4 kg) * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 5.7 (145 mm) 5.1 (130 mm) 6.6 (168 mm) M 3.9 (100 mm) Wiring diagram Part o. Heating capacity Operating voltage Setting range Approvals 03051.0-00 950 W AC 230 V, 50/60 Hz 0 to 60 C U File o. E234324, VDE 03051.0-02 950 W AC 230 V, 50/60 Hz 65 %RH, factory-set U File o. E234324, VDE 03051.0-07 950 W AC 230 V, 50/60 Hz none (no integrated controls) U File o. E234324, VDE 03059.9-00 950 W AC 120 V, 50/60 Hz 32 to 140 F U File o. E234324 03059.9-02 950 W AC 120 V, 50/60 Hz none (no integrated controls) U File o. E234324 CR030/11-12/US
10 20 0 30 40 50 60 CS 028 Touch-Safe PTC Fan Heater 150 W Quiet operation Heating power adjusts to ambient temperature DI rail or screw mount available The CS 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 028 s small size make it ideal for use in enclosures where space is at a premium. 2.95 (75 mm) 2.56 (65 mm) 3.54 (90 mm) Max. current (inrush) 6 A @ AC 120 V, 12 A @ AC 230 V Surface temperature max. 122 F (50 C) at housing, 212 F (100 C) at top grill; measured at 68 F (20 C) ambient temperature service life 40,000 h at 104 F (40 C) approx. 8 cfm (13.8 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max. Mounting screw mount or clip for 35 mm DI rail, E 60715 View: back side Screw mount DI clip Weight approx. 10.6 oz. (300 g) Operating / Storage temperature -49 to +158 F (-45 to +70 C) 3.74 (95 mm) 2.95 (75 mm) ote other voltages available upon request 1.26 (32 mm) Thermostat CS 028 Fan Heater 3 4-40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Wiring example Part o. Heating capacity 1) Operating voltage Dimensions Mounting Approvals 02800.0-00 150 W AC 230 V, 50/60 Hz 2.95 x 2.56 x 3.54 (75 x 65 x 90 mm) DI clip U File o. E234324, VDE 02800.0-01 150 W AC 230 V, 50/60 Hz 4.49 x 2.56 x 3.54 (114 x 65 x 90 mm) Screw mount U File o. E234324, VDE 02800.9-00 150 W AC 120 V, 50/60 Hz 2.95 x 2.56 x 3.54 (75 x 65 x 90 mm) DI clip U File o. E234324 02800.9-01 150 W AC 120 V, 50/60 Hz 4.49 x 2.56 x 3.54 (114 x 65 x 90 mm) Screw mount U File o. E234324 1) at 68 F (20 C) ambient temperature CS028/11-12/US
30 CS 030 Foot-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) Double insulated plastic housing The compact CS 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DI rail mount, the CS 130 fan heater is recommended. Heating Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, M Mounting clamping torque 0.8 m max. M5 screws (not included) horizontal Wiring diagram Operating / Storage temperature Dimensions -49 to +158 F (-45 to +70 C) 4.7 x 5.7 x 6.6 (120 x 145 x 168 mm) Weight approx. 2.6 lbs. (1.2 kg) 4.1 (105 mm) 5.7 (145 mm) 5.1 (130 mm) 6.6 (168 mm) 4.7 (120 mm) -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Setting range Approvals 03060.0-00 1200 W AC 230 V, 50/60 Hz 13.0 A 0 to 60 C U File o. E234324, VDE 03060.0-01 1200 W AC 230 V, 50/60 Hz 13.0 A none (no integrated controls) U File o. E234324, VDE 03060.9-00 1200 W AC 120 V, 50/60 Hz 16.0 A 32 to 140 F U File o. E234324 03060.9-01 1200 W AC 120 V, 50/60 Hz 16.0 A none (no integrated controls) U File o. E234324 CS030/11-12/US 1) at 68 F (20 C) ambient temperature
CS 028 Touch-Safe PTC Fan Heater 250 & 400 W Quiet operation Heating power adjusts to ambient temperature DI rail or screw mount available The CS 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 028 s small size make it ideal for use in enclosures where space is at a premium. Screw mount 4.33 (110 mm) 3.54 (90 mm) 3.35 (85 mm) View: back side 4.37 (111 mm) DI clip Surface temperature 250 W: max. 122 F (50 C) except upper protective grill, 400 W: max. 149 F (65 C) except upper protective grill; measured at 68 F (20 C) ambient temperature service life 40,000 h at 104 F (40 C) 32 cfm (54 m³/h) at AC 120 V; 26 cfm (45 m³/h) at AC 230 V 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, screw torque 0.8 m max. Mounting screw mount or clip for 35 mm DI rail, E 60715 Weight approx. 17.6 oz. (500 g) Operating / Storage temperature -49 to +158 F (-45 to +70 C) 1.26 (32 mm) Thermostat CS 028 Fan Heater Wiring example -40 C -20 C 0 C 20 C 40 C 60 C -40 F -4 F 32 F 68 F 104 F 140 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Dimensions Mounting Approvals 02810.0-00 400 W AC 230 V, 50/60 Hz 15 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324, VDE 02810.0-01 400 W AC 230 V, 50/60 Hz 15 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324, VDE 02810.9-00 400 W AC 120 V, 50/60 Hz 9 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324 02810.9-01 400 W AC 120 V, 50/60 Hz 9 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324 02811.0-00 250 W AC 230 V, 50/60 Hz 9 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324, VDE 02811.0-01 250 W AC 230 V, 50/60 Hz 9 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324, VDE 02811.9-00 250 W AC 120 V, 50/60 Hz 6 A 3.54 x 3.35 x 4.37 (90 x 65 x 111 mm) DI clip U File o. E234324 02811.9-01 250 W AC 120 V, 50/60 Hz 6 A 5.08 x 3.35 x 4.37 (129 x 65 x 111 mm) Screw mount U File o. E234324 1) at 68 F (20 C) ambient temperature CS028/11-12/US
1.26 (32 mm) 1.26 (32 mm) HV 031 Fan Heater 100-400 W Flat design Built-in overheat protection 3-side DI rail mountable Shown: 100W - HV 031 Fan Heater The compact HV 031 high-performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. For large OEM use, this fan heater can also be provided without the fan, in which case the OEM/customer must provide a fan which meets the minimum airflow requirements. 2.81 (71.5 mm) Important! Heater must be operated together with a fan. Operating without a fan creates the danger of overheating. 100W/ 150W Heater Mounting hole for DI clip 0.98 (25 mm) 0.87 (22 mm) 0.16 (4.2 mm) 3.15 (80 mm) high performance cartridge Overheat protection built-in temperature limiter Heater body die-cast aluminum, glass bead finish 3-pole terminal AWG 14 max. (2.5 mm²), torque 0.8 m max.. housing Mounting clip for 35 mm DI rail, E 60715 horizontal Operating / Storage temperature -49 to +158 F (-45 to +70 C) / I (grounded) / service life 50,000 h at 77 F (25 C) see table below Axial fan connection 2-pole terminal AWG 14 max. (2.5 mm²), terminals 2/2 Approvals U File o. E187294 (all), VDE (230VAC only) Air flow abel Axial fan 2.68 (68 mm) 0.71 (18 mm) HV 031 Fan Heater 200W/ 300W/ 400W Heater Mounting hole for DI clip 0.16 (4.2 mm) 0.98 (25 mm) 0.87 (22 mm) Thermostat 4.13 (104.8 mm) 4.68 (119 mm) Air flow 1 2 abel Axial fan 2.68 (68 mm) 0.71 (18 mm) Part o. - AC 120 V Part o. - AC 230 V Heating capacity Min. airflow (free blowing) Dimensions (as mounted) Weight (approx.) 03102.9-00 03102.0-00 100 W 20 cfm (35 m³/h) 1.85 x 3.15 x 4.41 (47 x 80 x 112 mm) 1.3 lbs. (600 g) 03103.9-00 03103.0-00 150 W 20 cfm (35 m³/h) 1.85 x 3.15 x 4.41 (47 x 80 x 112 mm) 1.3 lbs. (600 g) 03113.9-00 03113.0-00 200 W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) 03114.9-00 03114.0-00 300 W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) 03115.9-00 03115.0-00 400 W 63 cfm (108 m³/h) 1.85 x 4.68 x 5.94 (47 x 119 x 151 mm) 2.0 lbs. (900 g) HV031/11-12/US
CSF 060 Touch-Safe PTC Heater 50-150 W ow surface temperature Integrated thermostat Wide voltage range Double insulated protection DI rail mountable The CSF 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. This model with plug-in thermostat does not require additional wiring. The CSF 060 is also available in a version without thermostat (CS 060). Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heating capacity see table Surface temperature < 176 F (80 C), except upper protective grill 4-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -40 to +158 F (-40 to +70 C) / -49 to +158 F (-45 to +70 C) Approvals VDE *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. 200 178 CSF 060 Heater 150 100 50 122 66 160 110 61 147 102 55 132 93 50 119 85 44 150 W 100 W 50 W Part o. Wiring example Heating capacity 1) Max. current (inrush) Air outlet temperature 2) 0-40 C -40 F Switch-off temperature 3) Switch-on temperature 3) Dimensions Weight (approx.) 06001.0-00 50 W 2.5 A 187 F (86 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 10.8 oz. (305 g) 06002.0-00 50 W 2.5 A 187 F (86 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 10.8 oz. (305 g) 06011.0-00 100 W 4.5 A 248 F (120 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 11.2 oz. (320 g) 06012.0-00 100 W 4.5 A 248 F (120 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54 (133 x 60 x 90 mm) 11.2 oz. (320 g) 06021.0-00 150 W 8.0 A 293 F (145 C) 59 F (15 C) 41 F (5 C) 6.8 x 2.36 x 3.54 (173 x 60 x 90 mm) 15.9 oz. (450 g) 06022.0-00 150 W 8.0 A 293 F (145 C) 77 F (25 C) 59 F (15 C) 6.8 x 2.36 x 3.54 (173 x 60 x 90 mm) 15.9 oz. (450 g) 1) see Heating capacity / Ambient temperature diagram 2) measured 2 (50 mm) above protective grill 3) tolerance of ± 5K -20 C -4 F 0 C 32 F Ambient Temperature 20 C 68 F 40 C 104 F CSF060/11-12/US
HG 046 Fan Heater 250 & 400 W Built-in overheat protection ong service life DI rail mountable The compact HG 046 fan heater prevents formation of condensation. The integrated high performance axial fan provides forced air circulation and so guarantees an even temperature in enclosures. The heater is wired using the internal terminal connectors. 3.94 (100 mm) 3.35 (85 mm) Overheat protection Heater body Surface temperature resistance - micanite built-in temperature limiter extruded aluminum, anodized 400 W heater - max. 167 F (75 C) service life 50,000 h at 77 F (25 C) 3.35 (85 mm) AC: 26 cfm (45 m³/h) - 50 Hz; 32 cfm (54 m³/h) - 60 Hz DC: 32 cfm (54 m³/h) 3-pole terminal AWG 16 max. (1.5 mm²) with strain relief, clamping torque 0.8 m max. housing Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) ote: In the case of DC 24 V and DC 48 V, the fan heater must be switched via a relay. For this application, the SM 010 Electronic Relay (Part o. 01000.0-00 or 01001.0-00) is recommended. Pilot contact e.g. KT 011 Thermostat Heater Fan Heater HG 046 (AC 120 V or AC 230 V) Heater Fan Heater HG 046 (DC 24 V or DC 48 V) SM 010 Electronic relay Pilot contact e.g. KT 011 Thermostat Part o. Heating capacity Operating voltage ength () Weight (approx.) Approvals 04640.0-00 250 W AC 230 V, 50/60 Hz 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324, VDE 04641.0-00 400 W AC 230 V, 50/60 Hz 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E234324, VDE 04640.9-00 250 W AC 120 V, 50/60 Hz 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324, VDE 04641.9-00 400 W AC 120 V, 50/60 Hz 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E234324, VDE 04640.1-00 250 W DC 24 V 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324 04640.2-00 250 W DC 48 V 7.2 (182 mm) 2.4 lbs. (1.1 kg) U File o. E234324 04641.2-00 400 W DC 48 V 8.7 (222 mm) 3.1 lbs. (1.4 kg) U File o. E234324 HG046/11-12/US
30 CR 130 Panel-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat Double insulated plastic housing Panel or DI rail mounting The compact CR 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 130 was designed as a stationary unit for panel or DI rail mounting. For foot mounting on the bottom of an enclosure, the CR 030 fan heater is recommended. high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, clamping torque 0.8 m max. Mounting clip for 35 mm DI rail, E 60715 or M6 screws (not included) horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 6.3 x 7.2 (99 x 160 x 182 mm) Weight approx. 3.1 lbs. (1.4 kg) * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 2.6 (67 mm) 5.6 (142 mm) 3.9 (99 mm) 6.3 (160 mm) 7.2 (182 mm) Wiring diagram M Part o. Heating capacity Operating voltage Setting range Approvals 13051.0-00 950 W AC 230 V, 50/60 Hz 0 to 60 C U File o. E234324, VDE 13051.0-02 950 W AC 230 V, 50/60 Hz 65 %RH, factory-set U File o. E234324, VDE 13051.0-03 950 W AC 230 V, 50/60 Hz none (no integrated controls) U File o. E234324, VDE 13059.9-00 950 W AC 120 V, 50/60 Hz 32 to 140 F U File o. E234324 13059.9-02 950 W AC 120 V, 50/60 Hz none (no integrated controls) U File o. E234324 CR130/11-12/US
CREx 020 Explosion-proof Heater 50 & 100 W arge convection surface Maintenance free DI rail mountable The CREx 020 convection heaters are used in areas with explosion hazard to maintain minimum operating temperatures to help prevent failure of electronic components caused by condensation and corrosion. Explosion protection according to E CIE (aboratoire Central des Industries Electriques) Conformity certificate 01 ATEX 6073/03, CIE 06 ATEX Q8011, IECEx CI 07. 0021 high performance cartridge Heater body aluminum profile, black anodized Si HF - JZ 3 x AWG 18 (0.75 mm²), length 3.3 ft (1 m) PE 4 mm² Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) IP65 4.65 (118 mm) DI clip can alternatively be mounted to other side 2.7 (69 mm) 5.9 / 7.1 (150 / 180 mm) Type: CREx 050W EEx d IIC T5 AC 230-240V / 50W Art. r. 02010.0-00.C.I.E. 98.E 6110 Serial o.: e pas ouvrir sous tension. Attendre 15 min. avant ouverture. icht unter Spannung öffnen. Vor öffnen 15 min. warten. Do not open while energized. Wait 15 min. before opening. France S.A. Part o. Operating voltage Heating capacity Ex protection type Surface temperature ength () Weight (approx.) 02010.0-00 AC 230-240 V 50 W d IIC T5 - Ex td A21 IP6x T100 C 212 F (100 C) 5.9 (150 mm) 2.9 lbs. (1.3 kg) 02010.0-01 AC 110-120 V 50 W d IIC T5 - Ex td A21 IP6x T100 C 212 F (100 C) 5.9 (150 mm) 2.9 lbs. (1.3 kg) 02011.0-00 AC 230-240 V 100 W d IIC T4 - Ex td A21 IP6x T100 C 275 F (135 C) 7.1 (180 mm) 3.3 lbs. (1.5 kg) 02011.0-01 AC 110-120 V 100 W d IIC T4 - Ex td A21 IP6x T100 C 275 F (135 C) 7.1 (180 mm) 3.3 lbs. (1.5 kg) CREx020/11-12/US
30 CS 130 Panel-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) Double insulated plastic housing Panel or DI rail mounting The compact CS 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for panel or DI rail mounting. For foot mounting on the bottom of an enclosure, the CS 030 fan heater is recommended. Heating Overheat protection built-in temperature limiter service life 50,000 h at 77 F (25 C) 94 cfm (160 m³/h) 2-pole terminal AWG 14 max. (2.5 mm²) with strain relief, M Mounting clamping torque 0.8 m max. clip for 35 mm DI rail, E 60715 or M6 screws (not included) horizontal Wiring diagram Operating / Storage temperature Dimensions -49 to +158 F (-45 to +70 C) 4.7 x 6.3 x 7.2 (120 x 160 x 182 mm) Weight approx. 2.6 lbs. (1.2 kg) 5.6 (142 mm) 6.3 (160 mm) 7.2 (182 mm) 2.6 (67 mm) 4.7 (120 mm) -40 C -20 C 0 C 20 C 40 C -40 F -4 F 32 F 68 F 104 F Ambient Temperature Part o. Heating capacity 1) Operating voltage Max. current (inrush) Setting range Approvals 13060.0-00 1200 W AC 230 V, 50/60 Hz 13.0 A 0 to 60 C U File o. E234324, VDE 13060.0-01 1200 W AC 230 V, 50/60 Hz 13.0 A none (no integrated controls) U File o. E234324, VDE 13060.9-00 1200 W AC 120 V, 50/60 Hz 16.0 A 32 to 140 F U File o. E234324 13060.9-01 1200 W AC 120 V, 50/60 Hz 16.0 A none (no integrated controls) U File o. E234324 1) at 68 F (20 C) ambient temperature CS130/11-12/US
HG 140 PTC Heater 15-150 W Wide voltage range Heating power adjusts to ambient temperature Cage clamp connectors for quick & easy wiring DI rail mountable These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature must be maintained above a minimum value. The aluminum profile heater body design has a chimney effect to distribute heat evenly. The cage clamp connectors save time and simplify installation. Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heater body extruded aluminum profile, anodized 3 cage clamps for solid wire AWG 20-14 (0.5-2.5 mm²), and stranded wire AWG 20-16 (0.5-1.5 mm²) with wire end ferrule casing Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -49 to +158 F (-45 to +70 C) I (grounded) Approvals U File o. E234324, VDE ote other voltages available upon request *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. Part o. Heating capacity 1) Max. current (inrush) ength ( on dim. dwg.) Weight (approx.) 14000.0-00 15 W 1.5 A 2.56 (65 mm) 7.6 oz. (215 g) 14001.0-00 30 W 3.0 A 2.56 (65 mm) 7.6 oz. (215 g) 14003.0-00 45 W 3.5 A 2.56 (65 mm) 7.6 oz. (215 g) 14005.0-00 60 W 2.5 A 5.5 (140 mm) 14.1 oz. (400 g) 14006.0-00 75 W 4.0 A 5.5 (140 mm) 14.3 oz. (405 g) 14007.0-00 100 W 4.5 A 5.5 (140 mm) 14.3 oz. (405 g) 14008.0-00 150 W 9.0 A 8.66 (220 mm) 21.3 oz. (600 g) 1) at 68 F (20 C) ambient temperature
CS 060 Touch-Safe PTC Heater 50-150 W ow surface temperature Wide voltage range Double insulated protection DI rail mountable The CS 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 060 is also available in a version with a plug-in thermostat requiring no additional wiring (CSF 060). Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heating capacity see table Surface temperature < 176 F (80 C), except upper protective grill 4-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E 60715 Operating / Storage temperature -49 to +158 F (-45 to +70 C) Approvals U File o. E234324, VDE ote other voltages available upon request *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. 200 CS 060 Heater Thermostat CS 060 Heater 150 100 50 178 122 66 160 110 61 147 102 55 132 93 50 119 85 44 150 W 100 W 50 W Wiring examples 0-40 C -40 F -20 C -4 F 0 C 32 F Ambient Temperature 20 C 68 F 40 C 104 F Part o. Heating capacity 1) Max. current (inrush) Air outlet temperature 2) Dimensions Weight (approx.) 06000.0-00 50 W 2.5 A 187 F (86 C) 4.3 x 2.36 x 3.54 (110 x 60 x 90 mm) 10.4 oz. (295 g) 06010.0-00 100 W 4.5 A 248 F (120 C) 4.3 x 2.36 x 3.54 (110 x 60 x 90 mm) 10.6 oz. (300 g) 06020.0-00 150 W 8 A 293 F (145 C) 5.9 x 2.36 x 3.54 (150 x 60 x 90 mm) 15.5 oz. (440 g) 1) see Heating capacity / Ambient temperature diagram 2) measured 2 (50 mm) above protective grill CS060/11-12/US
CSK 060 Touch-Safe PTC Heater 10 & 20 W ow surface temperature Wide voltage range Double insulated protection DI rail mountable The CSK 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. Heating capacity see table Surface temperature < 185 F (85 C), except upper protective grill 2-pole terminal AWG 14 max (2.5 mm²), torque 0.8 m max. Mounting clip for 35 mm DI rail, E 60715 Operating / storage temperature -49 to +158 F (-45 to +70 C) Approvals U File o. E234324, VDE ote other voltages available upon request Thermostat CSK 060 Heater Wiring example Part o. Heating capacity 1) Operating voltage 2) Max. current (inrush) Dimensions Weight (approx.) 06030.0-00 20 W AC/DC 120-240 V 2.5 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 6.1 oz. (170 g) 06040.0-00 10 W AC/DC 120-240 V 1.0 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 5.0 oz. (140 g) 06040.1-00 10 W AC/DC 12-30 V 8 A 3.86 x 2.95 x 1.5 (98 x 75 x 38 mm) 5.0 oz. (140 g) 1) at 68 F (20 C) ambient temperature 2) operating high voltage heaters below AC/DC 140 V reduces heating performance by approx. 10% (min. 110 V, max 265 V). CSK060/11-12/US