Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Similar documents
Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Incremental Comfort Conditioners

Specifications and Performance

Specifications and Performance

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

E Z S E R I E S " W X 16" H

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

Enviromaster International LLC 5780 Success Dr. Rome, NY Nominal Capacities: 30,000-36,000 Btuh

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Commercial High-Efficiency Condensing Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

MAC N-407 Air-Cooled Chiller

Specifications and Performance S2H

Q-TEC QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Water Source / Geothermal Heat Pumps & Air Conditioners

PACKAGED TERMINAL AIR CONDITIONERS

Condensing Units & Air Handlers

Concealed Ducted Split Series R-407C MBH

PTAC 2017 Air Conditioner Collection

Packaged Terminal Air Conditioner (PTAC)

MACH N-407 Heat Pump Air-Cooled Chiller

PTW 42 Series 230/208 VOLT

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SKYPAK II, 3 Ton Series, gives you a

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Q-Tec TM QC-Series Chilled Water Air Conditioner

Packaged Terminal Air Conditioner (PTAC)

TECHNICAL SPECIFICATIONS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

Packaged Terminal Air Conditioner (PTAC)

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

SKYPAK II, 3 Ton Series, gives you a

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

VPRC / VPRH. Specifications and Performance. The Right Fit for Comfort. Vertical Packaged Air Conditioner/Heat Pump

13 SEER CONDENSING UNITS & AIR HANDLERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

WCH5**4. Product Specifications

R4H4. Product Specifications

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Profile SINGLE PACKAGE VERTICAL AIR CONDITIONERS. Features

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SKYPAK II Heating & Cooling Self Contained Packages

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

NEW 2011 DESIGN AIR CONDITIONERS

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Packaged Terminal Air Conditioner (PTAC)

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CM R-410A High Efficiency Water Source Heat Pump

N4H4. Product Specifications

Specifications and Performance

Commercial High-Efficiency Condensing Units

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SG SERIES PTACs THE EXPERTS IN ROOM AIR CONDITIONING

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Water Source / Geothermal Heat Pumps & Air Conditioners

General Description. Operation

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Single Package Vertical Air Conditioners

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

ZoneAire. Packaged Terminal Air Conditioners PRODUCT PROFILE PRODUCT PROFILE. Features THE EXPERTS IN ROOM AIR CONDITIONING

Samsung 360 Cassette, Single Zone, Split System

Single Package Vertical Air Conditioners

THRU-THE-WALL AIR CONDITIONERS

built-in comfort GE built-in air conditioners and heat pumps

Single Package Vertical Air Conditioners. Vert-I-Pak

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

SG SERIES. Packaged Terminal Air Conditioners PRODUCT PROFILE PRODUCT PROFILE. Features THE EXPERTS IN ROOM AIR CONDITIONING

Product Specifications. Vertical Floor Consoles By First Co.

CWA4 Chilled & Hot Water Fan Coil

Transcription:

Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE

New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment friendly, high efficiency cooling and heating where individual, quiet control is a priority. This application flexible unit is a small footprint vertical configuration thru-the-wall air conditioning system or heat pump (PTAC/PTHP) for new construction or property renovation. This highly flexible design typically fits into the corner of a room and serves one or more zones/rooms. A complete system consists of the chassis, a wall sleeve with outdoor louver, factory or site-built room cabinet with return air panel, wall thermostat, flex duct and supply air grille. The room cabinet can be a site-built closet with factory-available return air/access panel. This design provides a barrier between the unit and room occupants, thereby minimizing sound levels. The ducted air delivery system maximizes comfort. Proven technology, quality components, careful design and testing, and the latest in environment friendly technology mean long unit life, user satisfaction, and lower energy costs. Additional features include Rust-Block* corrosion protection system, slinger condenser fan, evaporator freeze protection, and evaporator fan post purge control. Adirondack-Aire is the choice that the competition can t match. Cold Point Corp. backs the PIN with a customer friendly one-year parts and labor warranty and five-year compressor warranty, (see Warranty document for details). Heat pumps are available and include a thermostatic expansion valve, suction accumulator and compressor crankcase heater. Heat pump heating is single-stage operation. Manual fresh air damper is standard on all models. The standard one inch disposable fiberglass air filter is chassis mounted. * Rust-Block corrosion protection system consists of: heavy gauge G90 rated galvanized steel construction, plastic or aluminum condenser fan, stainless steel compressor and condenser motor studs, powder painted drain pan, and Magnaguard and/or stainless steel screws and fasteners. Standard Features: Made in the USA Designed for easy installation and minimum footprint Exclusive Rust-Block corrosion protection High efficiency PSC fan motors with built-in temperature protection ETL approved Quiet, durable, and efficient compressor with built-in pressure and temperature protection Heavy gauge G60 galvanized steel construction Manual fresh air damper High efficiency copper tube-aluminum fin evaporator and condenser coils Slinger ring axial condenser fan Condensate re-evaporation Evaporator fan post purge control Frost-free low ambient cooling* Refrigerant circuit access ports (option) Heat pump heating to 35 F outdoor** (single stage) Capillary expansion. Thermostatic expansion valve (heat pump) Positive shift reversing valve (heat pump) Suction accumulator (heat pump) Precision charged with zerozone R-40A refrigerant Compressor crankcase heater (heat pump) Built-in anti-short cycle timer Chassis-mounted disposable fiberglass air filter * Cooling operation locks out at 34 F outdoor temperature and restarts at 55 F. **Actual temperature affected by relative humidity, solar effect, etc. Electrical Data* Compressor Type Voltage Volt-Hz-Ph Evaporator Motor Cond. Fan Motor Compressor Amps HP Amps HP RLA LRA Total Amps Ckt Ampac. Max Fuse Min Volts Line Cord** PIN-09 Rotary 5/60/.0 0.04.2 /0 8.0 50.0 0.3 2 20 04 5-20P PIN-09 Rotary 208/230/60/ 0.47 0.04 0.6 /0 3.7 22.0 4.8 6 5 97 6-5P PIN-09 Rotary 265/60/ 0.42 0.04 0.6 /0 3.5 22.0 4.5 5 5 240 NIA PIN-2 Rotary 5/60/.0 0.04.2 /0 9.5 50.0.8 4 20 04 5-20P PIN-2 Rotary 208/230/60/ 0.47 0.04 0.6 /0 4.7 25.0 5.8 7 5 97 6-5P PIN-2 Rotary 265/60/ 0.42 0.04 0.6 /0 4.2 22.0 5.2 6 5 240 NIA PIN-5 Rotary 208/230/60/ 0.60 /0.6 /4 5.6 29.0 7.8 9 5 97 6-5P PIN-5 Rotary 265/60/ 0.60 /0.6 /4 5.0 28.0 7.2 9 5 240 NIA * If electric heat option is selected, Total AMPS, Ampacity, Fuse Size and Line Cord data is found in the electric heat table. ** Line cord optional (N/A 265V)

PIN SERIES CHASSIS APPLICATION & BENEFITS Quiet Comfort The Adirondack-Aire PIN series vertical PTAC/PTHP offers the ease of installation, simplicity, and flexibility of a PTAC but offers major advances in quiet, comfort, and occupant satisfaction. The small footprint of this unit maximizes usable room space. The conventional wall thermostat control eliminates confusing buttons and dials and improves temperature control and occupant comfort. High efficiency compressors provide demonstrated reliability and low sound levels. The standard manual fresh air damper introduces fresh air to the room. Damage Protection A slinger ring condenser fan provides a blow-thru airflow pattern that reevaporates condensate, eliminating the need, cost, and maintenance of internal drains. The standard evaporator freeze protection stops unit operation before damage occurs, should airflow become reduced or obstructed due to dirty coils, obstructed airflow, or motor failure or lock up. Evaporator blower post purge control improves system efficiency. Condensate re-evaporation and the Rust-Block system assure a stain-free building exterior. The outdoor louver is an architectural style fabricated using rust-free clear anodized aluminum components. Options and Accessories Heat pump Hydronic heat assembly Electric heat Chassis stand Motorized fresh air Return air/ access panel Wall thermostat Internal drain Wall sleeves Louvers Control options LCDI line cord Performance Ratings Cool Btuh Sens Btuh EER Unit Sizes Heat Pump Cooling Btuh Heat Pump Sensible Btuh EER Heat Pump Heating Btuh COP CFM* (Nominal) Cond. Fan Type/ Air Direction Refrigerant PIN-09 9,400 6,800 9.5 9,800 6,600 0.4 9,200 3.0 350 R-40A PIN-2,200 7,700 9.5,500 7,700 0.2,200 3.0 325 Axial/ Blow Thru R-40A PIN-5 4,600 0,800 9.0 4,500 0,300 9.4 5,000 3.0 500 R-40A Continuous engineering improvements may result in performance changes without notice. * Dry coil airflow A B C D E Chassis Weight (lbs) PIN-09 43 6 /4 6 /2 26 /2 20 2 PIN-2 43 6 /4 6 /2 26 /2 20 25 C C PIN-5 43 6 /4 6 /2 26 /2 20 45 PIN-09 HYD HT 49 /4 6 /4 6 /2 26 /2 20 42 A PIN-2 HYD HT 49 /4 6 /4 6 /2 26 /2 20 55 D D PIN-5 HYD HT 49 /4 6 /4 6 /2 26 /2 20 75 B E E Heat Pump Heat Pump Only Only

Access Panel Dimensions A B C D E F PIN-09, 2, 5 49 /4 23 /8 22 48 22 /2 48 /2 PIN-09, 2, 5 HYD HT 49 /4 23 /8 22 48 22 /2 56 /2 Standard color is light beige. Custom colors available.

Grille Sizing* Grille PIN-09, 2, 5 () 6 x 4 * Or equivalent Wall Sleeve Dimension A B C PIN-09, 2, 5 7 8 /2 27 /2 Wall Sleeve Rough Wall Opening Width Height Depth* PIN-09, 2, 5 7 /2 28 Specify * Std. 0 wall depth

Electrical Heat Specifications Heater No. 2 3 4 5 * Line cord optional Volt Watts Btuh Htr Amps Total Htr Amps Min Ckt Amps Max Fuse Line Cord* Application 208,700 5,800 8.2 8.7 5 6-5P PIN- 09, 2 208,700 5,800 8.2 8.8 5 6-5P PIN- 5 230 2,070 7,050 9.0 9.5 2 5 6-5P PIN- 09,2 230 2,070 7,050 9.0 9.6 2 5 6-5P PIN- 5 265 2,750 9,365 0.4 0.9 4 5 N/A PIN- 09,2 265 2,750 9,365 0.4.0 4 5 N/A PIN- 5 277 3,000 0,230.4.9 5 5 N/A PIN- 09,2 277 3,000 0,230.4 2.0 5 5 N/A PIN- 5 208 2,255 7,690 0.9.4 4 5 6-20P PIN- 09,2 208 2,255 7,690 0.9.5 5 5 6-20P PIN- 5 230 2,760 9,40 2.0 2.5 6 20 6-20P PIN- 09,2 230 2,760 9,40 2.0 2.6 6 20 6-20P PIN- 5 265 3,660 2,480 3.8 4.3 8 20 N/A PIN- 09,2 265 3,660 2,480 3.8 4.4 8 20 N/A PIN- 5 277 4,000 3,640 4.5 5.0 9 20 N/A PIN- 09,2 277 4,000 3,640 4.5 5. 9 20 N/A PIN- 5 208 3,000 0,230 4.5 5.0 9 20 6-20P PIN- 09,2 208 3,000 0,230 4.5 5. 9 20 6-20P PIN- 5 230 3,675 2,530 6.0 6.5 2 20 6-20P PIN- 09,2 230 3,675 2,530 6.0 6.6 2 20 6-20P PIN- 5 265 4,880 6,640 8.5 9. 24 25 N/A PIN- 5 277 5,330 8,75 9.3 9.9 25 25 N/A PIN- 5 208 3,700 2,620 7.8 8.4 23 25 6-30P PIN- 5 230 4,520 5,45 9.7 20.3 26 25 6-30P PIN- 5

Hydronic Heat Performance Specifications Capacity CFM GPM EWT Btuh 6647 9 300 2 20 8827 3 9946 942 9 300 2 40 2454 3 4325 233 9 300 2 60 649 3 8782 5344 9 300 2 80 2073 3 23260 NEMA Configurations Non Locking Plugs/Receptacles Voltage 25V 250V 277V 5A Recp. 5A Plug 20A Recp. 20A Plug 30A Recp. 30A Plug Capacity CFM GPM EWT Btuh 2 350 2 350 2 350 2 350 6963 2 20 9452 3 0742 9869 2 40 3304 3 552 2905 2 60 7656 3 20384 609 2 80 2222 3 25278 Capacity CFM GPM EWT Btuh 5 450 5 450 5 450 5 450 744 2 20 0372 3 2038 0549 2 40 4648 3 7455 3798 2 60 9500 3 2309 729 2 80 24622 3 28607

INNOVATIVE HEATING AND COOLING SOLUTIONS Cold Point equipment has been specified in hundreds of projects in these and other applications: Direct Replacement New Construction Renovation Commercial & Residential Solutions Cold Point values reliability as much as you Your Cold Point sales representative knows their reputation is on the line with every sale. Therefore, they are as personally invested in your comfort as you are, and take great pride in creating your perfect indoor environment. Rest comfortably, knowing Cold Point stands behind our products The Cold Point Corporation backs our products with a standard warranty that includes labor for the entire first year of ownership. Registered Limited Warranty terms include: 2 month limited warranty on components, 60 month limited warranty on all unit compressors from the date of original installation OR 5 months limited warranty on components, 63 month limited warranty on all unit compressors from the date of original sale, whichever comes first. For all coverage options and complete coverage terms, check with your local Cold Point representative for full details. Industry-leading expertise Cold Point Corporation is the industry-leading supplier of aftermarket comfort solutions for commercial and residential applications. We have over 8 years of experience developing OEM-style replacement products to keep you happy and comfortable. Whether it is a water source heat pump application or an air source PTAC system, Cold Point has the knowledge and products to restore your system to its original operating condition. Reliable comfort products backed by the industry experts in OEM-style replacement units To learn more about how the Cold Point Corporation can help you save time and money on your next project, contact your local Cold Point representative. Call 35-339-233 to speak with one of our specialists, or e-mail your request to info@coldpointcorp.com. Your Cold Point Representative: 7500 Cold Point Dr Rome, New York 3440 Phone (35) 339-233 Fax (35) 339-2358 www.coldpointcorp.com 207 Cold Point Corp. All rights reserved. rev. -8 CPL03