POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Similar documents
Powerflow Unvented water heater

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented Electric Water Heater 10/15 litre Undersink

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Installation and User Instructions HS10U, HS15U.

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Unvented water heater

Zen Boiling Tap Range

HOTFLO 10 / 15. Fitting Instructions and User Guide

Handyflow Undersink HF05MVC

Automatic Infrared Tap TAPIFR. Instruction Manual

Unvented Direct & Indirect Hot Water Cylinders (400L L)

HS&S Alert No: 103 Date: 9 March 2017

Unvented Direct & Indirect Hot Water Cylinders (400L L)

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

TH01B, TH02B, TH03B, TH04B

MULTIPOINT 30 & 50 Litre

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Alpha CombiMax 350 and 600

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

Instructions & Maintenance

INSTANTANEOUS ELECTRIC SHOWER

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Quantum. Installation, User and Service Manual. Hot Spring

HOTFLO 10 / 15. Fitting Instructions and User Guide

SEALED THERMAL STORE

Multipoint Technical Data

Instructions for Use Installation and Servicing

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MULTIPOINT SS H 50/80 & 100

Technical and Installation manual All Models

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 210, 250 AND 300 LITRE CAPACITY INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

Zircon Installation Manual

PremierPlus Unvented Hot Water Cylinder Installation and User Manual

Unvented water heater

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

EPU - WM30 EPU - WM 50 EPU - WM100

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

Megaflo HE issue 6

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

MEGAFLO HE Iss 1

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 100 TO 300 LITRE CAPACITY DIRECT AND INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

SC2000Y, SC2000YST, SC2000YM

HW3 Handwash Installation and Operating Instructions

INSTALLATION & TECHNICAL MANUAL

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

Enzo Concealed Shower Mixing Valve

Installation Manual EXCELSIOR Unvented Water Heater

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Wall Hung Multipoint Water Heaters Installation & Maintenance Manual

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Installation & User Instructions

ZIP AQUAFLO II Unvented storage cylinders

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation, Operating and Maintenance Guide

Schuco SS-TC/SC Cylinders

Installation, operating and servicing instructions

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. PACK CONTENTS

Installation, Operating and Maintenance Guide

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

Inta City Concealed Shower Mixing Valve CT80010CP

Mimosa dual control mixer shower Installation and operating instructions

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

MEGAFLO Eco SystemReady Unvented Indirect Hot Water Cylinders

Unvented Direct & Indirect Hot Water Cylinders

WATER HEATERS INSTALLATION MANUAL

T E C H C A L EBS-1 T High technology heating

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Transcription:

POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009

Hyco POWERFLOW Series Unvented Electric Storage Water Heaters 1. Introduction & Technical Specification Thank you for purchasing a POWERFLOW Series Unvented Electric Storage Water Heater from Hyco Manufacturing Ltd. To use this equipment safely please read this manual carefully. When the unit is installed, the operation and maintenance section should be explained to the user of the equipment. Do not proceed with installation or operation if there is sign of any damage to the product or the power cord. If you have any queries regarding operation or installation please contact our technical department on 01977 517555. Read these instructions BEFORE attempting installation. Installation MUST be undertaken by a competent installer Trained in the installation of unvented water heating systems in accordance with Buildings Regulation G3. Building Regulation G3 requires a Temperature and Pressure relief valve to be factory fitted. This must not be removed or blocked in any way. Installation must comply with the latest edition of the IEE Wiring Regulations. These units are VERY HEAVY. They must be securely fastened to a suitably strong wall using the fixings supplied. Remember to allow for the weight of the water (one kg per litre of capacity) when assessing the suitability of the wall. 2. specifications Model PF30L PF50L PF90L Maximum water pressure to pressure reducing valve 12 bar Power (kw) 3.0 Voltage (V) 230V ~ 50 Hz Current (A) 13A Capacity (Litres) 30 50 90 Operating Pressure 3 bar Expansion vessel charge pressure 3 bar Expansion relief valve setting 6 bar Pressure Reducing Valve setting 3 bar Temperature and Pressure Relief 7 Bar 90 degrees C Minimum recommended pressure 0.8 bar Immersion heater specification Hyco PFEL30 EN60335 x 1 Weight empty (kg) 9 13 24 Weight full (kg) 39 63 114 Heat up time (from 13 C to 60 C) in minutes 21 40 86 Reheat time (70% contents to 60 C) in minutes 16.5 28 57 Height (mm) 620 915 930 Width (mm) 380 380 540 Depth (mm) 295 295 385 Tank Material Stainless steel Inlet / Outlet ½ BSP male 3. Installation Overview Components Checklist Expansion Vessel 3/4" MBSP, precharge pressure 3.5 bar Pressure Reducing Valve, factory set at 3 bar Single Check Valve 15mm x 15mm compression Pressure (expansion) Relief Valve 1/2" BSP male inlet, 1/2" BSP female discharge, factory set at 6 bar Tundish 15mm x 22mm This unit MUST be installed vertically, with the pipes pointing downwards and the Temperature and Pressure relief valve at the top. 1

3. Installation Overview (Continued) Ensure the wall is STRONG ENOUGH to support the heater, including the weight of the water when full. This heater is NOT suitable for outdoor installation. Do not install where there is any risk of freezing. Plan your installation carefully and choose a suitable position for the heater, allowing suitable space for accessories such expansion vessels, pipework and subsequent maintenance. See schematic Diagram 1 for the correct relative positions of the components. Temperature and Pressure Relief Valve Powerflow Pressure (Expansion) Relief Valve Expansion Vessel Balanced Cold Water Draw Off Service Valve Diagram 1 Hot Drain Cock Check Valve To Drain (Waste) Pressure Reducing Valve Cold Water Mains Fit ALL the components supplied. Components may be supplied loose or connected to a manifold. The manifold aids installation but does not alter the relative positions of the components. Do NOT remove the factory fitted Temperature and Pressure relief valve. Ensure in particular that there are no valves of any kind between the expansion relief valve and the heater. Allow at least 400mm of space above and below the unit to permit for maintenance. Observe flow direction arrows on components. 4. Mount on Wall Drill holes for supplied heavy duty bolts to wall at the spacings shown in the table below (also See Diagram 2). Insert bolt hooks and tighten ensuring that they are secure then hang heater on the protruding hooks. B Model Vertical Bolt Spacing A (mm) Horizontal Bolt Spacing B (mm) PF30L 270 320 PF50L 520 320 PF90L 430 320 A Diagram 2 2

5. Make Heater Plumbing Connections Connect ALL the plumbing valves in the sequence shown in diagram 1. The cold water inlet to the heater is marked BLUE and the hot water outlet is marked RED. Observe flow direction arrows on supplied valves. The drain valve must be fitted close to the COLD inlet to allow drain down if necessary. An isolating valve should be fitted UPSTREAM of all of the valves to allow the heater to be maintained without impacting on other facilities. Do NOT fit a service or other valves between the heater and the pressure relief (safety) valve as this could impede its correct operation. The pressure reducing valve is factory set at 3 bar. If a balanced cold water draw off is required this should be tee-ed off down stream of this valve. A balanced cold water feed is recommended as it ensures hot and cold water is supplied at the same pressure. Some mixer taps and thermostatic showers require hot and cold water to be to be at the same pressure for correct operation. The expansion vessel supplied must be supported using a bracket or similar fixing. Do not rely on the pipework alone it will not be strong enough. The orientation of the vessel is not important. When all valves are correctly fitted, open a hot tap and wait until the water flow is steady and without traces of air. Close the tap to allow the system to reach full pressure and carefully check system for leaks. Control valves may be supplied loosely connected for identification purposes, but these joins have NOT been leak tested. This must be done at installation. It is ESSENTIAL to also check the Temperature Pressure Relief valve connection to the heater for leaks. Note that a leak from the Temperature and Pressure relief valve may not be immediately obvious, as the connection is at the top of the heater and leaking water may in the first instance run down the pipework and collect in the heater insulation. 6. Discharge Pipe Connections (See Diagram 3, page 4) This product falls within the scope of Building Regulation G3 which stipulates certain conditions relating to the way any water discharge from relief valves is transported away. These conditions are designed to ensure that any discharge will not present a hazard to people or to property, and that any discharge is clearly visible so that the underlying cause is likely to be rectified promptly. The essential requirement of G3 in relation to water discharge is that the discharge pipe MUST terminate in a safe, visible position. In achieving this aim the G3 regulations strongly recommended that: 1. The tundish is located within 500mm of the Temperature and Pressure Relief valve and it is wherever possible oriented vertically. It must be visible to occupants and positioned away from electrical devices. 2. The discharge pipe has a vertical fall of at least 300mm immediately below the tundish. 3. The discharge pipe below the tundish is at least 22mm diameter (i.e. one size larger than the Temperature and Pressure Relief valve outlet). 4. The discharge pipe should be as straight and as short as is possible and positioned away from electrical components. Diagram 3 illustrates an acceptable discharge pipe arrangement. The table below the diagram specifies how the maximum acceptable pipe length from the tundish to the final outlet depends on the pipe diameter and the number of bends (reference the chart on page 4 for pipe sizing). For example in 22mm copper with no bends the pipe could be up to 9m long. With two bends present the maximum length drops to 9.0m - (2 x 0.80m) = 7.4m. 7. Electrical Connections The heater is supplied pre-wired with appropriate cable. Electrical installation should conform to the latest edition of the IEE Wiring Regulations. Electrical supply should be capable of isolation via a user-accessible double pole isolation switch rated for a 13A supply. 3

Metal Discharge Pipe (D1) from Temperature Relief to Tundish Safety Device 500mm MAXIMUM Tundish 300mm MINIMUM Metal Discharge Pipe (D2) from Tundish with Continuous Fall Discharge Below Fixed Grating Fixed Grating Diagram 3 Trapped Gully Sizing of D2 Copper Discharge pipe for common temperature relief valve outlet size Valve outlet size Minimum size of discharge pipe (D1) Minimum size of discharge pipe (D2) from Tundish Maximum resistance allowed, expressed as a length of straight pipe (I.E. no elbows or bends) G1/2 15mm 22mm up to 9m 0.8m 28mm up to 18m 1.0m 25mm * to 27m 1.4m 8. Commissioning Visually re-confirm all plumbing and electrical connections are sound. Open a hot water tap and turn on mains water supply to the Powerflow heater Allow unit to fill and leave tap running for a short time to flush out the pipework and purge any air from the system before closing the hot tap and checking the system for any leaks. Check the operation of the Temperature and Pressure relief valve located at the top of the heater twisting the knob at the top of the valve. This lifts the valve seat and water will flow rapidly and be visible at the tundish. Ensure the discharge pipe can cope with this flow rate continuously. Release the Temperature and Pressure relief valve. The flow should stop completely. Open the expansion relief valve and likewise check that water flows freely through the discharge pipe, that the discharge pipe can cope with the flow rate and that the water flow ceases when the valve is released. Switch on the electrical supply and select an appropriate heater setting on the thermostat knob (the thermostat is adjustable in the approximate range 20 C to 65 C. The neon indicator light comes on when the element is heating. 9. Draining the Unit To drain the unit disconnect electrical supply and close service valve on cold inlet. Open the drain cock on cold inlet and open a hot water outlet to enable air to replace draining water. Resistance created by each elbow or bend Note that a small quantity of water will remain in the tank. This residual water can only be drained by removing the heating element. 4

10. Maintenance - Electrical Components Always switch the electrical supply off before undertaking any maintenance to the heater unit. Servicing of electrical parts should only be undertaken by competent individuals. All maintainable electrical components are located under a plastic cover that is next to the inlet and outlet pipes and held in position with two small screws. Remove screws and lower cover to provide access to components. See diagram below for electrical parts identification. If replacing electrical parts take particular attention to ensure that the earthing connections (green/yellow) to the element flange and thermostat housing are sound. 11. Maintenance - Thermal cut-out re-set This unit contains a manually re-settable thermal cut-out that will switch the power off if the temperature reaches an abnormally high level. To reset the cut-out the press button as shown in Diagram 4. Thermostat Diagram 4 Thermal cutout - Press here to reset Element flange - Remove to access anode 12. Maintenance De-scaling procedure If scale is allowed to build up heater performance will suffer and the life of the product will be reduced. The effects of limescale are excluded from any warranty. To de-scale the heater, gain access to the element following the instructions set out in section 10. Remove thermostat and thermal cut-out bulbs from respective pockets and unscrew the 6 nuts holding the element flange in position. Withdraw element. Remove scale carefully. If necessary, dip element in a de-scaling solution available from DIY or plumbing outlets. Do not allow electrical connections to become wet. It is not normally necessary (or practical) to attempt to remove any scale from the tank walls. Refit element and follow commissioning instructions as per section 8. 13. Maintenance Anode inspection There is a magnesium anode fitted to most models of the Powerflow. It is a grey magnesium cylinder fitted to the element base and its role is to reduce the rate of corrosion of the tank. It should be inspected periodically and replaced if there are signs of disintegration from a solid metallic structure. To access the anode, follow instructions in section 10. Remove scale carefully. If necessary, dip element in a de-scaling solution available from DIY or plumbing outlets. Do not allow electrical connections to become wet. 5

13. Maintenance - Anode inspection (Continued) It is not normally necessary (or practical) to attempt to remove any scale from the tank walls. Refit element and follow commissioning instructions as per section 8. 14. Maintenance - Safety Valve Checks The Temperature and Pressure relief and expansion relief valve relieve any dangerous pressure or temperature build up that may arise as a consequence of abnormal operation. BOTH valves should be tested periodically by twisting the cap and checking that water flows freely.the water flow should cease when the valve is released. The pressure reducing valve contains a wire mesh gauze that may become clogged over time.to clean, close off mains water and open a hot outlet to drain the system of water. Unscrew the plastic top of the pressure reducing valve from the brass housing and remove complete mechanism including wire mesh. Rinse mesh to remove grit, scale etc as necessary and replace. Re-commission system following instructions as per section 8. 15. Maintenance Expansion Vessel Water expands when it is heated.the expansion vessel accommodates expanded water during the heating cycle via a pressurised diaphragm arrangement so that water is not wasted. The vessel is supplied already pressurised to 3 bar.over time the pressure may be lost and water may be discharged during the heating cycle. The pressure should be checked using a standard car tyre foot pump or similar device. The pressure should be re-set to 3 bar. 16. Troubleshooting Symptom Likely Fault(s) Remedy Water not heating Thermal cut-out needs re-setting Reset as section 11. Element failure Thermostat failure Thermal cut-out failure Electrical supply failure Replace Replace Replace Check supply is present Water too hot Thermostat set too high Reduce setting Fit thermostatic mixing valve Water milky coloured Dissolved gases coming out of solution as they are heated this is normal condition for pressurised systems Water discharged during heating cycle only Water discharged all the time Expansion vessel has lost its charge Either the pressure reducing valve is failing to reduce the water pressure to 3 bar approx, or one of the safety valves is operating at below is nominal level. To differentiate measure the water pressure downstream of the pressure reducing valve. If the pressure is more than about 4 bar, replace the pressure reducing valve. No action needed. Water will turn clear after standing for a few seconds. Re-pressurise vessel as section 15. Replace appropriate valve. If the pressure is less than 4 bar, replace the safety valve that is opening. No / limited water flow Check mains water is turned on. Check pressure reducing valve for grit. Mixing valves not working correctly Unbalanced pressure. Ensure cold is tee-ed off after pressure reducing valve so hot and cold are at equal pressure. 6

17. User Instructions This water heater will store water at a temperature selected via the thermostat on the front of the heater. To set the temperature turn the control clockwise to increase the temperature and anti-clockwise to decrease it. The indicator light comes on when the unit is heating. Maximum energy efficiency and product life is obtained avoiding very high temperature settings. The optimal temperature setting balances these factors. The maximum temperature setting is about 65 degrees. This can be excessively hot for some situations. In situations where very young children, the elderly or other vulnerable people are likely users a suitable thermostatic mixing valve should be fitted by your installer. If there is any risk of frost the heater should be left switched on at it lowest heat setting. If the heater is to be left unused for long periods, it should be drained. This unit should be maintained in accordance with the instruction in the sections 12-16. Never interfere with any safety valves. Be aware that hot water discharged from safety valves could be very hot. 18. Guarantee and Service Policy This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion repair, replace or refund any faulty unit. Incorrect installation and the consequences of limescale deposits are excluded. Consequential losses such as damage to fittings or labour charges are excluded from this guarantee. Hyco Manufacturing Ltd California Drive Whitwood Castleford West Yorkshire WF10 5QH Tel: 01977 517555 Fax: 01977 517666 Web: www.hyco.co.uk E-mail: sales@hyco.co.uk 7