QUICK START GUIDE. QUESTemp o 32 Heat Stress Monitors

Similar documents
QUICK START GUIDE. QUESTemp o 34/36 Heat Stress Monitors

Element B10 / 1 Thermal Comfort

Sustainable HVAC Design: Using Air Movement in Air Conditioned Buildings

WBGT Heat Stress Meter

Comfort and health-indoor air quality

Dehumidification Strategies Application Note

Microtherm Heat Stress WBGT


Getting Started. 1 Please visit for more information.

Heat Stress WBGT Meter Model HT30

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

Humidity An excuse for the 80s

Unit THE NATURE OF HEAT

Energy and Heat Balance *

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

AR/IA/UP 241 Lecture 5: Psychrometrics

The New DUSTTRAK II and DRX Aerosol Monitors

The New DUSTTRAK II and DRX Aerosol Monitors

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

RIGID DC LIQUID CHILLER

ULT Freezer Performance Testing Emerson Design Services Network Project #

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

Contamination Control for Electronic and Semiconductor Applications

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

Removing The Potential For Condensation In An Electronic Cabinet

Solution. System. Pocket Guide for Occupational and Environmental Health Professionals

liquid heating The density of the liquid changes as its temperature increases. This causes energy to be transferred throughout the liquid.

Longline Heating. Contents. Introduction

Rosemount 3051S Electronic Remote Sensors

Solutions. Detection. 3M Personal Safety Division 3M Detection Solutions Products. Pocket Catalog for Safety Professionals

Model 5190-F Temperature/Humidity Probe

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

Incutrol/2 Regulator

USER GUIDE Heat Index Psychrometer

Model 5190-E Temperature/Humidity Probe

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Optimize Evaporative Cooler

CO2 TRANSCRITICAL BOOSTER SYSTEMS

HVAC (Heating, Ventilating, and Air Conditioning)

1SC-SSC Splice Connection Kit Installation Instructions

Global Water Pipeline Leak Detection System (LDS) Market: Trends, Opportunities and Forecasts ( )

Presentation on HVAC: Heating Ventilation Air Conditioning

Meteorology 432. Hygrometry Spring 2013

Thermohygrometer with Single Type K Input and Superheat Function

Contamination Control for Life Science Applications

Use this Construction/HVAC Glossary to answer the questions below.

Air-Handling System Cooling Options

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

& Tips. Basics. Insulation INSULITE HANDBOOK

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Science 7 Chapter 6 Section 1

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

On Balance: Heat Rejection Control a Packaged Solution

A99B Series Temperature Sensors

The SharpEye 40/40I (IR3) Flame Detection

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Factory and Field Installed Splices

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Conceptual Physics Fundamentals

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

MT4 MAX/MT4 MAX + Infrared Thermometer

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Microsprinkler Irrigation for Cold Protection of Florida Citrus 1

Thermal Energy. Conduction, Convection, and Radiation. Before You Read. Read to Learn. Conduction. section 2

Passive cooling of telecommunication outdoor cabinets for mobile base station

62 MAX/62 MAX + Infrared Thermometer

MAXIMIZING FACILITY PERFORMANCE WITH INNOVATIVE HVAC & IRRIGATION SYSTEMS

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

Infrared Thermometer

Refrigeration & Air-Conditioning Laboratory REPORT. Prepared by: AURKO CHATTERJEE 10ME10069 REFRIGERATION AND AIR-CONDITIONING LABORATORY REPORT 1

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

FEB. 17 Rev. A1

Food Service Technology Center

safe and your operations compliant

The Dangers of Heat Stress

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Atmospheric Moisture: Relative Humidity and Dew Point

As mentioned earlier, the fundamental purpose of HVAC systems is to provide human comfort.

SWIMMING POOL HEAT PUMPS

Refrigeration & Air Conditioning Laboratory Laboratory Manual Spring 2016

IRT2 Dual Laser IR Thermometer - User Guide

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

Unlocking the Potential of Blood TSCD II. Next-Generation Terumo Sterile Tubing Welder

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

Air Conditioning Clinic

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Bourns Thick Film Resistive Heaters

Authentic experience in a powered, secured display.

How to ensure Thermal Comfort in buildings with CFD

Wet Bulb Thermo-Hygrometer Datalogger

Transcription:

QUICK START GUIDE QUESTemp o 32 Heat Stress Monitors

Up and running 1. Make sure the wet bulb wick is clean. Fill reservoir with distilled water. + Check and fill wet bulb reservoir: remove the reservoir cover and fill with distilled or de-ionized water. Replace cover. 2. Place the instrument in the work area approximate 3.5 feet off the ground. 3. Power on the instrument by pressing I/O Enter key and check the battery. (If the battery is less than or equal to 6.4 volts, replace or recharge the battery.) 4. Allow 10 minutes for sensors to stabilize. 5. The measurements will be displayed. Press I/O Enter key to page through the screens. + Screens include: Wet Bulb and Dry Bulb screen, Globe screen, WBGTi and WBGTo screen, RH and H.I. screen, and BAT (Battery voltage) Wick Reservoir cover Reservoir

QUESTemp o 32 components Natural Wet Bulb Thermometer Globe Thermometer Dry Bulb Thermometer Removable Sensor Bar Two Line Display Sensor Bar 2 and 3 I/O Enter Key Up/Down Arrow keys Setup Key

Common heat stress terms Acclimatization: the body s ability to adapt to heat exposure up to a certain point. Body core temperature: The temperature of the arterial blood irrigating the thermo- regulatory centers in the hypothalamus. Conduction: If the transfer of heat between materials that contact each other. Heat passes from the warmer material to the cooler material. For example, a worker s skin can transfer heat to a contacting surface if that surface is cooler, and vice versa. Convection: Is the transfer of heat in a moving fluid. Air flowing past the body can cool the body if the air temperature is cool. On the other hand, air that exceeds 35 o C (95 o F) can increase the heat load on the body. Dry Bulb Temperature: The temperature of air as registered by a thermal sensor shielded from direct radiant energy sources. Evaporative Cooling: Takes place when sweat evaporates from the skin. High humidity reduces the rate of evaporation and thus reduces the effectiveness of the body s primary cooling mechanism. Globe Thermometer: A black copper sphere with an internal thermal sensor used to determine the effect of surrounding radiant heat. Heat Index (HI): The Heat Index represents how an average person feels relative to climate conditions. For a given temperature, the higher humidity, the higher the Heat Index. Heat Stress: The total net heat load on the body which results from exposure to external sources and from internal metabolic heat production.

Common heat stress terms Metabolic Heat: Heat produced by the body in relationship to work that the individual is doing. The more strenuous the work, the higher the metabolic heat and the harder the body has to work to eliminate it. Micro-Environment: A self-contained environment, such as the inside of a hazardous materials suit, in which thermal exchange with the surrounding air is limited. Natural Wet Bulb Temperature: Used to measure the effect of humidity in air obtained by a wetted sensor that is exposed to natural air movement. Radiant Heat: Heat which is transferred to cooler objects in the surrounding environment. Workers can incur exposure to radiant heat from the sun, hot asphalt, machines and ovens. Relative Humidity: The ratio of the amount of water vapor in the air compared to the greatest amount possible at a specific temperature. WBGT (Wet Bulb Globe Temperature): A weighted average which combines the effects of humidity, air velocity, ambient air temperature and radiant energy into one single index. The resulting WBGT values can be compared to indices of work-rest regimens (stay times) based upon work loads. WBGT (indoor) = 0.7WB + 0.3G (denoted as WBGTi on the display) WBGT (outdoor) = 0.7WB + 0.2G + 0.1DB (denoted as WBGTo on the display)

Quest is a trademark, and TSI and the TSI logo are registered trademarks of TSI Incorporated. TSI Incorporated - Visit our website www.tsi.com for more information. North America and Asia Pacific Telephone: +1 800-680-1220 (USA) +1 651-490-2860 (Outside USA) Fax: +1 651-490-3824 E-mail: technical.services@tsi.com Europe, Middle East, and Africa Telephone: +49 241-52303-0 Fax: +49 241 52303-49 E-mail: tsigmbh@tsi.com P/N 053-045 Rev G 2018 TSI Incorporated