LC-3DPRINT BOX. Instruction For Use. LC-3DPrint Box

Similar documents
User s Instruction Manual. NextDent LC-3DPrint Box Instructions for use

User s Instruction Manual Vertex GelMelt 8 Instructions for use

Corning LSE 6L Digital Water Bath

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Accuracy counts! Sensors with analog output

STT 3000 Series STT250 /150 Surge Protection Device Specifications

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Advantages of automatic boiler bottom blowdown

International Product Compliance and Certifications. Product Safety Consulting, Inc.

Nautilus 4050 Heat Press. User Manual

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Fire-Resistant. Automatic Doors

Installation Instructions

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

KNX The worldwide STANDARD for home and building control. KNX Association International

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

CRA24-B3 controlled residential ventilation

WHEN TIME IS OF THE ESSENCE, ONYX FIRSTVISION TM

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

The advantages of closed heating systems. White paper

Future development of the furniture industry A look at the next 3-5 years

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

KNX The worldwide STANDARD for home and building control. KNX Association International

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

BA2702-P Linear Actuator

Portable Sous Vide Instruction Manual

Operation Manual Part-No

Corning LSE Benchtop Shaking Incubator

Corning LSE Digital Dry Bath Heater

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Waterpik Water Flosser Model WF-06

Infrared Thermometer

Return loss measurement of fiber optic components

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Type Approvals GARAGE DOOR OPENER RADIO TRANSCEIVER. (EuroHomeLink 2000) Czech Republic CTU R 1194 Cyprus MCW129/95 12/2000 Denmark 98.

PROCESSING UNIT II V Hz V Hz. Table of Contents

INSTALLATION INSTRUCTIONS ESS 7.0

4th Morocco Furniture; International Furniture & Decoration Fair Gathered visitors from 28 to 31 March 2018

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

Instructions. Consumer Info-Line

BFD Light Curtains The new choice for cutting edge safety for industrial doors

AERO 20 AERO ENGLISH - Operating Instructions

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

BILL COUNTER (NCOUNTER) OPERATION MANUAL

PTG, SWT Series. Heat Recovery Systems

Air and dirt in closed systems

Labeling and Identification Products

Health & Safety and Installation guide

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

Owner Instructions HVR Warning! Read instructions before using the machine

NETWORKING AND INTEGRATION

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

Dry Bath Heating Systems

POLYMIX PX-IG 2000 Operating Instructions

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

stylemakerstm SINCE 1895

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

Introduction. Duncan Hogg Energy Market Manager (507) :50 p.m.

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

WORLDS MOST ADVANCED ANTI-PRY DESIGN 2018 PRODUCT CATALOGUE

U ser's Guide PC6010

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

DIGITAL STEEL FIRE & SECURITY

Signal converters SVE4 Product overview

User Manual for Convection Oven

Manual. Electro Plus. Use and Installation ELECTRIC TOWEL HEATER

Ultraviolet Water Sterilizer Installation and Maintenance Manual

GAN Electronic 750W/1000W DE EU

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

5KSBC1B0XX W B_01_EN_v03.indd 1 5/16/17 11:09 AM

PRODUCT MANUAL. Lynx Mold Mount Piezoelectric LP/LX1 M. Training and Technology for Injection Molding

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

Beckhoff short profile

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

62 MAX/62 MAX + Infrared Thermometer

KFP-CF Series Operation Manual

Instruction Manual. Seco. Dry-running Rotary Vane Vacuum Pumps SV 1003 D, SV 1005 D

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

profi-air 180 flat condensate pump Installation and operating instructions

Visit for more technical information and downloads.

Installation instructions. Built-in oven. and User guide NZ AU GB IE. OB60 single & double multifunction models

Owner Instructions Original Instructions Warning! Read instructions before using the machine

OPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART

STANDARD T6 (200 C) SENSOR CABLE RANGE

ELEKTRON ELEKTROLABORATORIJSKE - VISOKOTEMPERATURNE PEĆI. The view from the back of the oven

Expansion vessel in a solar installation. White paper

30th. English. Anniversary Since 1980 RICH. Heat & Cool molding system RICH-2. ZICUL (Chiller) WATER PURIFIER

SERVICE MANUAL REFRIGERATION

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

CHEFLUX M A N U A L ENGLISH

Heinz Lux. Director, KNX

UV I UNIT030W / UV I UNIT055W

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Transcription:

LC3DPRINT BOX Light Polymerisation unit (Postcuring oven) Leading manufacturer of dental materials for 3D printing Instruction For Use LC3DPrint Box The following instruction is for professionals who want to use the NextDent TM LC3DPrint Box as a light polymerisation unit (postcuring oven) LC3DPrint Box is used to dry and polymerize 3D printing objects which need an additional drying and polymerising process. This unit is equipped with 12 pcs of 18W lights in order to dry and fully polymerize the 3D printed objects. Page 1 of 10

Page 2 of 10

STOP: READ ME FIRST. DO THIS AT INSTALLATION. Check And Change Your Voltage If Needed The LC3D Print Box comes with a preset voltage from the factory that may require changing to align with your country specific voltage rating. Note: No damage will occur to your unit if plugged into a different voltage than how the unit is configured. For proper heater and light output, it is required to select the correct voltage. This is a onetime setting done at initial setup of your LC3D Print Box. Voltage Selection on Print Box 100V 110V/115V 120V/127V 220V 240V Follow these instructions on how to change the preset voltage to your country specific voltage. Please see the Voltage Chart below to identify your country specific voltage. Note: If your country is not listed, choose the correct voltage from the pulldown list on the print box (see voltage list below). After print box is turned on, the preset voltage appears at lower right corner of welcome screen. It will also display on the main screen in the upper right corner. Country Voltage Country Voltage US 120V Australia Germany Italy Spain UK Ukraine France New Zealand S. Korea 220V Canada China 120V 220V Mexico 120V / 127V UAE 220V / Taiwan 110V Russia 220V / Czech Republic Chile 220V Turkey 220V / Portugal Morocco 220V / 127V India Page 3 of 10

If the voltage needs to be changed, Please follow these steps to adjust the voltage setting. 1. Access the engineering mode display screen by pressing the Arrow Up and Down button together and hold for 3~4 seconds. 3. To save the voltage, turn off the LC3D Print box using the power switch on right side of the print box. 2. In engineering mode (voltage appears in the top, middle of screen), change voltage by pressing the P button. Please wait until you see that the voltage has changed. Continue to press the P button until your country specific voltage rating appears. 4. Once saved, the newly set voltage should appear on the Welcome screen when the unit is turned back on. This particular unit has been changed to 220V. Specifications Type of unit: Model name: Rated Voltage: Power Consumption: Fuse: Dimension: Weight: Light Polymerisation unit (Postcuring oven) LC3DPrint Box AC110240V 50/60Hz Max. 264W AC250V T5.0A W410 x D440 X H380 22Kg Page 4 of 10

General cautions Read this manual before use. This machine should be used by professionals only. The builtin safety mechanism should not be removed or modified. Do not allow unauthorized persons to repair the machine. Do not use this machine for any other kind of material than NextDent TM 3D printing Materials. Package content NextDent TM LC3DPrint Box AC Power cable (250V,10/16A) 6 pcs of UV18W lamps71 colour 6 pcs of UV18W lamps78 colour Metal plate with glass insert Instruction for use Electric diagram Declaration of conformity Warranty conditions Transportation / preparing the site of machine For units weighing more than 18kg (units weight: 22kg), transportation unit like a pallet truck is needed and at least two persons are needed for transportation and installation. The surface should be flat and free of dust. Make sure there is enough space on all sides. Make sure that there is enough space between fan and wall. This unit is for indoor use only. Environmental conditions Temperature and Humidity: 5~40 C / 80% Indoor use only Steps for installation Please read instructions for use. Specifically read general caution including safety information. Connect all the lamps (12pcs) to all lamp sockets which are placed in the cover and the chamber. The recommended position of the supplied lamps (6pcs of 18W lamps71color and 6pcs of 18W lamps78color) is as shown in picture on the right. Please make sure of rated voltage and power supply (110240V 50/60Hz). Only the supplied power cable can be used. Connect the power cable with connector plug to the power socket. Safety warning label and symbol information & Safety information Do not touch live electric parts. Turn off power source and disconnect power cable before installing or servicing the machine. Turn off the machine when not in use. Do not use worn and damaged cables. Use only well maintained equipment. Keep away from children. Always turn off the machine before cleaning. Do not open the cover when machine is in use. Do not cover the fan at the back. Only use the machine with Figure 4 TM, Fab Pro TM, and NextDent TM 3D printing materials. Wear UV protective glasses. Do not touch the cover during operation, this cover warms up. Wear protective gloves. The longest program is for 30 min. the temperature inside the working chamber can go up to 80 C. Protective earth. Wear UV protective glasses. Caution! UV light hazard. Avoid eye and skin exposure. Wear proper eye and skin protection. Wear protective gloves. Be aware of the potential dangers of lifting heavy loads. Ignoring this can lead to injuries. This device may only be lifted and moved to its final destination for installation by two people. Page 5 of 10

Rear Fan Front Front panel Fuze Box and AC power cable socket Identification label Fan The machine is equipped with a fan to cool down the inside and maintain a proper working temperature inside the machine. Fan operates when the machine is in use and cooling is needed. If the fan does not work the temperature will raise and ERROR1 will appear in the display. (see error message) Front panel Display / LCD Fuse Box and AC power cable socket FUSE AC50V T5.0A Increase button Decrease button Program button Start/Stop button Side Description of function key Start/Stop button Start / Stop button for starting and stopping operation. Increasing button Button for increasing the operation time. Decreasing button Button for decreasing the operation time Power On / Of button Program button Program button for choosing the preset programs. (preset programs are: 10, 20 and 30 min) Page 6 of 10

Cover Inside Lamp holding clamp Operation Please put the bottom plate with glass insert inside the chamber and put a printed and cleaned object on the glass. Then operate the machine according to the following program operations and the instructions for use of the material used for printing the part. Starting mode Press the power switch (green button) on the right side of the machine. Lamp holding clamp Reflection plate Lamp Socket Silicone Oring Lamp socket welcome! LC3DPRINT BOX V300 1/110V When switching on the machine, the version information will appear in the display. Chamber inside 10:00 END After 5 seconds, the last operation time will appear on the display. Working Progress Cover locking sensor Cover Locking Sensor: sensor for opening and closing. The machine does not work when opened. Lamp holding clamp Reflection plate Lamp Socket Metal plate with glass insert Operation Mode 10:31 RUN Working Progress 00:00 END Working Progress When the last operation time has appeared on the display, the user can choose a preset time by holding the program button. Or the user can increase or decrease the operation time by pressing the increase or decrease button. Start the machine by pressing the start/stop button. The time will count down and the dots will be blinking. (By pressing the start/stop button, the operation time will be memorized automatically). Stop the machine by pressing the start/stop button again. After operation time, the message End will be displayed automatically. At the same time, the machine beeps 9 times. Plate has two handles Page 7 of 10

Maintenance General instructions Repair or maintenance of the machine, must be carried out by qualified persons only. Any repair or maintenance must be carried out with official replacement parts supplied from the manufacturer/distributor. Before cleaning, please remove the power plug from the power supply. For cleaning, please use a soft cloth with mild cleaning agent. Operation of this machine must be done according to this instructions for use. If error continues after replacing the lamps, the ballast must be replaced by a qualified person. Lamp 1/2 = Ballast 1 Lamp 3/4 = Ballast 2 Lamp = Ballast 3 Lamp = Ballast 4 Lamp = Ballast 5 Lamp = Ballast 6 Error message by automatic selfchecking system. 10:31 OPEN Working Progress The message OPEN will appear on the display when a user opens the cover during operation. At the same time, the machine beeps three times. 00:31 ERR1 Check IFU ERROR 1: In case the temperature around ballast reaches over 60 C, the machine stops automatically and Err1 will appear on the display. 71 Color Lamp: 1, 3, 5, 7, 9, 11 78 Color Lamp: 2, 4, 6, 8,10,12 Always change 2 lamps 71/78 together 00:31 ERR2 Check IFU 00:31 ERR3 Check IFU ERROR 2: When there is a problem with the temperature sensors, the machine stops automatically and Err2 will appear on the display. (contact distributor) ERROR 3: If there is a defective lamp, numbers belonging to the defective lamp or lamps will change to red on the display. ERR3 & Check IFU message will also appear on the display. When operation time elapses, change the indicated lamps. Always replace both indicated lamps, to insure constant UV output. This error will also occur if the voltage is not set to match the country supplied voltage. Lamp Time: 750h 00:31 ERR5 Check IFU ERROR 5: will appear if the the UV Lamps have burned for 750 hours. (Lamp time). Between the 740 and 750 hours burned the change alll lamps message will appear in the display. Indicating that all lamps must be replaced before reaching 750h. When the 750h burning time of the lamps is reached the machine will stop and beep, showing ERR5 The change all lamps message will appear. Replace all lamps with new ones according to the schedule above. After changing the lamps reset the timer by pressing the decreasing button for 5 seconds. The lamp time will now read 000h. Machine will be ready for use. When replacing the lamps, always disconnect the power cable, or switch off the machine to prevent burns. Let the lamps cool down for several minutes before replacing them. Please note that electrical/electronic units must be disposed off separately. Do not dispose with household waste. The black bar on the garbage bin symbol indicates that the unit was put into circulation after August 13, 2005. Please note that the unit is subject to regulation 2002/96/EC (WEEE) and applicable following national laws and must be disposed off accordingly. Please contact your dealer if the unit needs to be disposed of. Page 8 of 10

Page 9 of 10

For more information, please contact: Warranty Hotline from the Americas +1 888.598.1438 +1 803.326.3930 Weekdays during normal business hours or by email at SupportUS@3DSystems.com Warranty Hotline from Europe, Africa, and Middle East (EMEA) +44 1442.279.839 +49 6151.357.499 Weekdays during normal business hours or by email at SupportEMEA@3DSystems.com. Warranty Hotline from Asia/Pacific +852.8191.2453 Weekdays during normal business hours or by email at SupportAPAC@3DSystems.com. www.nextdent.com 2016 VertexDental B.V. All Rights Reserved NextDent is a registered trademark of VertexDental B.V. used under a temporary license granted by NextDent B.V.. Neither. NextDent B.V. nor any of its affiliates is responsible for the manufacturing of the product(s). IFU ID: ILCPB201801UK PN: 40D093, Rev B Page 10 of 10