REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

4. Distances to property line, buildings, other tents, parked vehicles and engines;

REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES

Outdoor Festival and Special Event Guidelines

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

Tents and Temporary Membrane Structures Packet

Tents and Temporary Membrane Structures Permit Procedure

FIRE DEPARTMENT PERMIT GUIDELINES

EXCELSIOR FIRE DISTRICT

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

General Festival Conditions & Temporary Use of Tents Conditions of Approval

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

UC Irvine Environmental Health & Safety TITLE: Special Events Program

Fire and Life Safety Requirements San Mateo City Special Events

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Township of Upper Providence Office of the Fire Marshal

South Elgin & Countryside Fire Protection District

City of Leduc Fire Services Indoor Special Event Requirements

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

Saturday, September 9 th 2017 ***** NO PETS ALLOWED

FOOD PREPARATION WITHIN EXHIBITS

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

FIREDEPARTMENT REGULATIONS AND GUIDELINES

FIRE DEPARTMENT CONDITIONS BELLEVUE FESTIVAL OF THE ARTS Fire Retardant or Flame Retardant Treatment

Canby Fire District 221 S. Pine Street Canby, OR97013 Bus Fax Fire Marshal, Todd Gary

SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

HEALTH DEPARTMENT Environmental Health, Mosquito Control, Neighborhood Protection, Stormwater, and Animal Services

MOBILE FOOD VENDING Food Trucks & Trailers

FIRE SAFETY GUIDELINES

MOBILE FOOD VENDOR DEFINITION & FIRE INSPECTION INFORMATION

PERMIT APPLICATION Central Pierce Fire & Rescue 902 7th Street NW - Puyallup, WA Telephone (253) Fax: (253) 538.

PALM SPRINGS FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS, CONVENTIONS AND SPECIAL EVENT GATHERINGS BASED ON THE 2010 CALIFORNIA FIRE CODE

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

VENDOR BOOTH APPLICATION. Hitched Trailer Food Truck/ Van Canopy Enclosed Tent Other

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

All orders are governed by the GES Payment Policy and GES Terms & Conditions of Contract as specified in this Exhibitor Services Manual.

SAFETY GUIDELINES INDIANA STATE FAIRGROUNDS & EVENT CENTER. Fairgrounds Security:

Exhibits and Trade Shows Permit Application

OCFEC Fire Marshal Summary Report

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

McCormick Place Fire Safety Regulations

Department of Public Safety

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

Stillwater Area Community Services Center Inc.

Fire Safety Guidelines and Requirements CenturyLink Field and Event Center June 2015

FIRE & SAFETY REGULATIONS (Updated )

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

PLACES OF ASSEMBLY CHAPTER 17

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Business Fire Inspection. City of Guadalupe

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

Anticipated Date and Time for Completion of Break-Down:

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

Business License Pre-inspection Checklist

Saturday, September 29, 2018

Ramapo College of New Jersey

Temporary LPG Heat for Construction Sites Information Packet

Element 14.7 Fire Prevention and Control 2018

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

Demolition Permit Application (Please print and complete ENTIRE form)

The City of Temecula Community Services Department

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

To expedite the plan review and inspection processes, please refer to the information below.

LP GAS PIZZA OVEN USER MANUAL

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

NFPA 101 Life Safety Code Culture change 2012

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

CHAPTER 38 FIRE PREVENTION

EVERGREEN RECREATIONAL VEHICLE SHOW SEPTEMBER 29, 30, OCTOBER 1, Exhibitor Information Balance of contract due before move-in

Fire and Life Safety Review Form

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

FIRE PREVENTION CODE

TAMUCC Fire Safety Training

MULTI-LEVEL & COVERED BOOTH CONDITIONS

Washington State Convention Center Fire Safety Guidelines

Osceola County Department of Fire Rescue and Emergency Medical Services

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Fire Safety Handbook

New Facilities. Minimum Requirements

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Fire Prevention Plan

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

Educational Occupancies

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Transcription:

UC Davis Health Fire Marshal s Office 4800 2nd Ave, #1200 Sacramento, CA 95817 (916) 734-3036 hs-fireprevention@ucdavis.edu FIRE MARSHAL S OFFICE Food Booth and Vendor Regulations Introduction Vendors invited to participate in events sponsored by various organizations on the UC Davis Medical Center or UC Davis Health campus are expected to abide by all applicable fire and life safety regulations concerning the vendor s specific service as either cited or referenced in Title 19 and Title 24 of the California Code of Regulations. Listed below are certain minimum fire and life safety requirements, which are common to most events involving food or craft booths. Please take the time to understand these requirements as well as other applicable requirements to make your area of service as safe as possible. Should you have any questions, please contact the UC Davis Health Fire Marshal s Office at 916-734-3036. Prior to the beginning of each event, all vendor booths will be inspected by the UCDH Fire Marshal s Office. Once all applicable fire and life safety requirements, including but not limited to those listed below are met, an inspection compliance tag will be issued to the vendor. The tag must be attached to the booth and displayed in a conspicuous location throughout the event. However, if the inspector determines that the vendor does not comply with minimum fire and life safety requirements, the event coordinator will be notified and the vendor will be asked to correct the problems or discontinue operation. This standard will apply to all tents and membrane structures. Note: Food booths and food trucks must provide a health permit at onset of inspection. Please contact the County Health Department for more information. Note: The event coordinator is responsible for compliance of all regulations. A signed copy of the Food Booth and Vendor Regulations Agreement Form shall be posted in the structure and signed by the vendor. By signing this form the vendor agrees to comply with these regulations. The signed copy will be available on request for review by the UCDH Fire Marshal s Office. Definitions Tent: A structure, enclosure or shelter, with or without sidewalls or drops, constructed of fabric or pliable material supported in any manner except by air or the contents that it protects. Food Booth: A food service establishment that operates at a fixed location in conjunction with a Community Event as defined in the California Health and Safety Code section 113755. Vendor Booth: All booths except food service booths. Page 1 of 5

UC Davis Health Fire Marshal s Office 4800 2nd Ave, #1200 Sacramento, CA 95817 (916) 734-3036 hs-fireprevention@ucdavis.edu Food Booth Construction and Location All fabrics or membranes covering-food booths must bear a conspicuous and durable label indicating that the material is flame resistant. Label and wording must be consistent with the requirements of Title 19 of the California Code of Regulations. Decorative materials must be inherently fire resistive, or must be treated with a fire-retardant paint or spray. Flooring material used within a food booth and under cooking equipment must be noncombustible or fire-retardant treated. All tarps must have the CPAI-84 certification label attached. Untreated plastic tarps will not be accepted. Each food booth must have at least one exit, minimum 3 feet wide by 6'8" in height (booth frame shall not intersect exit path). Food booths with cooking appliances must have a minimum clearance of 10 feet on at least two sides with clearance of at least 10 feet from any vendor booth. Note: For covering, decorative or flooring material listed above, a flame test may be required for non-certified flame retardant or treated materials. A field flame test will require a s ample of material measuring 2 inches by 12 inches. EXCEPTION: 3/8" Plywood or similar material. Heating Equipment All interior heating equipment must be of an approved type and must be a minimum of 18 inches from booth back/side drop materials. Heating equipment shall not be located within 18 inches of exits or combustible materials. Outdoor cooking that produces sparks or grease laden vapors shall not be performed within 10 feet of a tent. Electrical heating equipment shall comply with the California Electrical Code and be UL listed. Propane LP-gas equipment such as tanks, piping, hoses, fitting, valves, tubing and other related components shall be approved and in accordance with the California Fire Code and the California Mechanical Code. Containers shall be located outside. Safety release valves shall be pointed away from the tent, canopy or membrane structure. Containers may NOT be located in approved fire lanes. If containers are located in the fire lane, they will be relocated or the piece of equipment will not be used. Portable LP-gas containers with a maximum capacity of 20 gallons or less shall have a minimum separation between the container and structures of not less than 10 feet. Portable LP-gas containers, piping, valves and fittings which are located outside and are being used to fuel equipment inside a tent, canopy or membrane structure shall be adequately protected to prevent tampering, damage by vehicles or other hazards and shall be located an approved location. Containers shall be secured in an upright position and must be located at least 5 feet apart from each other. Rubber hoses or metal flexible hoses connecting the tank with the appliance must be approved for Page 2 of 5

UC Davis Health Fire Marshal s Office 4800 2nd Ave, #1200 Sacramento, CA 95817 (916) 734-3036 hs-fireprevention@ucdavis.edu propane. The letters LPG and the symbol U/L on the hose are sufficient evidence of acceptability. Slip-end connectors are not allowed; rubber hoses must be fitted with factorymade metal fittings. Cooking appliances must have an on-off valve placed far enough away to be shut off in case of a fire. Shut-off valves must be provided at each fuel source. No storage of extra propane tanks will be allowed in the booth. Tanks not in use must be turned OFF. Unused fuel cylinders shall be stored in a secured position. Unused and empty cylinders must be located 50 feet away from all combustibles. Maximum outside storage is 10 gallons. Note: Specialized cooking equipment, used outside of the booth may have larger tanks, when approved by the UC Davis Fire Marshal. Vendor Booth Construction and Location Each vendor booth shall have at least one exit, minimum 3 feet wide by 6'8" in height (booth frame shall not intersect exit path). Vendor booths shall have a minimum clearance of 20 feet on at least one side with clearance of at least 10 feet from any cooking booth. A 10-foot wide separation shall be provided for every 20 -lineal foot of vendor booths. Electrical Power Generators will be placed in locations approved by the UCDH Fire Marshal s Office for festival use. Generators will be located a minimum of 20 feet from tents, canopies or vehicles and will be isolated from contact with the public by approved means. Refueling of generators is prohibited during event hours. No extra fuel shall be stored during event hours. During approved refueling times, no smoking or open flames are allowed within 25 feet of the generator. Each generator must be provided with a fire extinguisher with a minimum 40B:C rating. The extinguisher shall be located near the generator and accessible at all times. Extension cords will be of grounded type, approved for exterior use and one continuous cord not exceeding 100 feet. Extension cords will not be frayed or worn and will not be laid in any areas with pedestrian traffic unless they are covered by an approved means determined by the UCDH Fire Marshal s Office. Page 3 of 5

UC Davis Health Fire Marshal s Office 4800 2nd Ave, #1200 Sacramento, CA 95817 (916) 734-3036 hs-fireprevention@ucdavis.edu Frying/Flambé/Open Flame Cooking Cooking with charcoal inside a tent or membrane structure is prohibited. Frying is defined as any cooking operation or process whereby the product floats or is submerged in hot oil during the cooking process. Frying is prohibited inside booths and must be located 20 feet from both sides and 3 feet from open flame cooking devices. Frying must not be accessible by the general public. Frying equipment must be equipped with a temperature regulating device or other method of regulating temperatures approved by the Fire Marshal. Frying operations must be equipped with a Class K Type fire extinguisher. Fire Extinguishers 1. Each cooking booth must be equipped with a fire extinguisher with a minimum rating of 2A:10B:C. (5 LB dry chemical extinguisher) 2. For vendor booths, the maximum travel distance to a fire extinguisher with a minimum rating of 2A:10B:C must not exceed 75 feet. 3. Booths that will be frying will require a Class K Type fire extinguisher. 4. Fire extinguishers must be visible and accessible. 5. Fire extinguishers must be serviced annually and be tagged accordingly. 6. Each generator must be provided with a fire extinguisher with a minimum 40B:C rating. The extinguisher shall be located near the generator and accessible at all times. Fire Access 1. Fire Hydrants Fire Hydrants must not be obstructed 10 feet on either side at any time for any reason. 2. Streets Parking is limited, therefore, do not leave your vehicle parked where it will block the street in such a manner as to prevent other vehicles from passing. 3. Fire Apparatus Access Access roads shall have an unobstructed width of not less than 20 feet with vertical clearance of 13 feet, 6 inches. Fire Safety Tips 1. Know where the nearest fire extinguisher is located and how to use it. 2. DO NOT leave cooking operations unattended. 3. DO NOT wear loose fitting clothing while cooking. 4. Remove trash accumulation regularly. 5. Keep combustibles away from heat sources. 6. In case of emergency, DIAL 911 or (916) 734-2555 from a cell phone. Page 4 of 5

UC Davis Health Fire Marshal s Office 4800 2nd Ave, #1200 Sacramento, CA 95817 (916) 734-3036 hs-fireprevention@ucdavis.edu Food Booth and Vendor Regulations Agreement A copy of these requirements and regulations shall be posted in the structure and signed by the vendor. By signing this form the vendor agrees to comply with these regulations. The signed copy will be available on request for review by the UCDH Fire Marshal s Office. For questions, please call the UCDH Fire Marshal s Office 916-734-3036 Food Booth Operator s signature Date of Event Food Booth Operator s printed name Booth Name UCDH Fire Marshal s Office Inspector Date of Inspection Page 5 of 5