Pinhole Detector Data Sheet / Instructions

Similar documents
THE COMPLETE SOLUTIONS PACKAGE

PRODUCT INSTRUCTIONS MODEL M/1 WET SPONGE HOLIDAY DETECTOR. Unpacking Checklist. The Model M/1 Holiday Detector Kit includes the following:

Introduction to Docking Technology

Spy model 673 wet sponge holiday detector ope rati ng instructions

Elcometer 270. Pinhole Detector. Operating Instructions

Operating Instructions

Hazardous Area Zirconia Oxygen Systems

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

CHANGING THE WORLD OF INDUSTRIAL FIRE PROTECTION

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Your specialist partner for total electrical compliance. Electrical Testing

BLOOD PRODUCT STORAGE.

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

DiscovR R134a Refrigerant Identifier

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

T.ex Single Gas Detector VISA

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

PNEUDRI High Efficiency Compressed Air Dryers.

PAC1500Xi PORTABLE APPLIANCE CHECKER

Ingersoll Rand. Refrigerated Air Dryers

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

REFRIGERANT LEAK DETECTOR

FURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER

CD100A COMBUSTIBLE GAS DETECTOR

Design Manual Installation Operation Maintenance

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Conventional & Twin-wire Fire System

Unrivalled Detection.

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Quantum Production Limited

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

WEB & SHEET CLEANING SYSTEMS

SENSIT HXG-2d Combustible Gas Detector

Ingersoll Rand. Refrigerated Air Dryers. mb air systems ltd

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Zareba Metro Gas Detector

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

PERSONAL COMBUSTIBLE GAS DETECTOR

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Electromagnetic Flowmeters

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information


QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

ELD500 PRECISION LEAK DETECTOR

Wireless DC Voltage Detector

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Tube skin temperature sensors for surface measurement

G-TECTA TM. Portable Gas Detection Instruments

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co.

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

APPLICATION DATA SHEET

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

Datalogging as standard

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Manual Vane Anemometer PCE-VA 20

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Instruction Manual MSI Sensit HXG

We measure it. testo 316-Ex CH 4 testo 316-1

KAE Gas Alarm Operation Manual

Precision Infrared Thermometer. Users Manual

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

OPERATING INSTRUCTIONS

CO warning instruments and gas spillage detectors

Equipment specifications (D6)

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

LD-5000 REFRIGERANT LEAK DETECTOR

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

LABORATORY ILLUMINATED FLOTATION BATH

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Digital Salt / TDS Meter. 390a. The Value Leader TM

Dräger X-am 7000 Multi-Gas Detection

HART XL High Sensitivity Smoke Detection

Operation and Maintenance Manual

Transcription:

Paint Test Equipment Pinhole Detector Data Sheet / Instructions

Pinhole Detector Information ISO 29601: Paints and varnishes. Corrosion protection by protective paint systems. Assessment of porosity in a dry film. The Pinhole Detector uses the wet sponge principle to detect through-pinholes, cracks and damaged areas on non-conductive coatings on conductive substrates. These flaws would eventually lead to corrosion and premature failure of the coating. Operation is by a wet sponge, moistened with a wetting agent, being moved over the coating. The wetting agent penetrates any pinhole and makes a conductive path through to the substrate. The Pinhole Detector has test voltages of 9 Volts, 67.5 Volts and 90 Volts, which are easily selectable. The Calibration Certificate with traceability to UKAS is an optional extra. The Certificate is supplied as hard copy and is available online through the Calibration Management Cloud (under Calibration) on our website. Supplied in an industrial foam-filled Carrying Case with 150mm Sponge Assembly and 5m Earth Cable. The Pinhole Detector detects this conductive path and indicates that a pinhole has been detected by sounding an audible alarm and giving a visual warning by a red flashing indicator.

Pinhole Detector Operation Pinhole Detector Specifications Part No Range Maximum Test Thickness 9V Maximum Test Thickness 67.5V Maximum Test Thickness 90V Accuracy Cal Cert Part No S3002 9V/67.5V/90V 300µm (12mils) 500µm (20mils) 500µm (20mils) 1% NS002 SA005 Earth Cable 20m SS004 Spare Earth Cable 5m SS005 Spare Sponge Assembly 150mm

Pinhole Detector Accessories Circular Sponges for the testing of internal diameter of pipes. Pinhole Circular Sponges Part No Product Size Metric Size Imperial Extension Size SA601 Circular Sponge and Assembly 50mm 2 200mm / 8 SA602 Circular Sponge and Assembly 100mm 4 200mm / 8

Holiday Detector Accessories Extension Rods extend Sponges for applications where a long reach is required. Pinhole Extension Rods Part No Product Size Metric Size Imperial SA002 Extension Rod 500mm 20 SA003 Extension Rod 1000mm 40

Pinhole Detector Operation Safety Safety precautions must be strictly adhered to whilst using the Pinhole Detector. The Pinhole Detector must not be used in any area which could have a combustible or flammable atmosphere, as the test voltage can cause a spark and an explosion could occur. All items under test must have a secure connection to earth or ground. Testing Wet the Sponge with water containing a wetting agent. Squeeze the Sponge so that the excess water is removed and the Sponge does not drip. Place the Sponge on the coating to be tested and move over the full area of the coating, ensuring a wet interface is maintained between the Sponge and the surface. If a pinhole is detected, the water will make a conductive path through the pinhole in the coating to the metal substrate, the alarm will sound and the red flashing fault indicator will illuminate. The flaw can now be marked for repair and further testing can be resumed. To switch the Pinhole Detector off, press the mode keypad until the selectable voltages indicators are not illuminated. If the coating has been applied recently, it should be cured in accordance with the manufacturer s instructions before testing. In the absence of manufactures instructions the coating should be cured for at least 10 days. The surface of the coating should be free of oil, dirt and other contaminants before testing. Connect the plugs on the Pinhole Detector Handle and Earth Cable to the colour-coded sockets on the base of the instrument. Connect the Earth Cable to the base metal of the item under test. It is essential that the base metal of the item being tested is also connected to a true earth. Switch the Pinhole Detector on and select the test voltage of 9V, 67.5V or 90V using the mode keypad. The test voltage should normally be 90V. A test voltage of 9V can be used for coatings with a mean thickness of up to 300µm.

Pinhole Detector Operation General Replacing Battery When the battery requires replacement, the red Lo Bat indicator will illuminate. To replace, remove the cover located on the rear of the instrument. Replace with an alkaline PP3 battery, ensuring correct polarity.

About Us Paint Test Equipment is a global leader in the manufacture of specialist test equipment specifically for the industrial painting and coating industries for the protection of steel assets from corrosion, mainly in the oil, renewables and steel construction sectors. We have over 30 years experience and extensive knowledge in delivering practical solutions in supporting our customers with world class products for corrosion prevention. Prevention of corrosion on steel is essential to extend the asset lifetime, optimise performance and minimise downtime for expensive maintenance work. Using Paint Test Equipment products ensures that industrial coatings are applied to the highest achievable quality standards of ISO compliance. We supply small, medium and multinational companies with the full range of technologies and innovations in our unrivalled portfolio of products for our customers to grow their business and enhance profits through cost effective corrosion management equipment. Paint Test Equipment is committed to providing proactive and innovative solutions to meet customer requirements for the highest quality, user friendly inspection equipment. Paint Test Equipment is the partner of choice. Paint Test Equipment reserves the right to alter specifications without prior notice. Copyright Paint Test Equipment 2018. Paint Test Equipment 3 4 The Courtyard Greenfield Farm Estate Congleton, Cheshire CW12 4TR, England www.paint-test-equipment.com Tel: +44 (0)1260 275614 e-mail: sales@paint-test-equipment.com