Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Similar documents
Bulletin , March Electric Hot Gas Bypass Valves

General information on refrigerant controllers

Cerberus FIT conventional system

Acvatix PICV hydronics made easy. The simple and flexible way to energy-efficient HVAC plants with pressure-independent combi valves

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Saving energy while ensuring an enhanced room climate

Install intelligent room automation flexibly and future-proofed

EN aquatech.piovan.com

Room thermostat with 24-hour time switch and large LCD

1592P01. for liquids in piping DN

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Emerson Superheat Control. The smart solution for your application

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Your specialized partner for intelligent building technology

Environmentally friendly refrigeration systems for industrial use

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Tube-in-tube heat exchanger Type HE

Control Products & Systems OEM

Zero Superheat Control

Chapter-8 Capacity Control of Refrigeration Systems

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

EC3-X33 Stand-alone Superheat Controller Technical Data

XC10 Extinguishing control panels

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Sinorix Silent Extinguishing Technology protecting the quiet way

FCHM Hydromatic Pump Control Module

Product Catalog VALVES

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

What extinguishes fires without pressure peaks?

EC3-X33 Stand-alone Superheat Controller

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Air-Cooled Condensing Units with Compact Screw Compressors

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

PoleStar Smart Refrigerated Air Dryers don t just cycle, cycle Smart.

food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

HT V2 HT Split

v SELECTION GUIDELINES

F Series - Refrigeration dryers

FDA241, FDA221 Siemens ASD

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Frost Units for air temperature monitoring

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

How can you minimize consequential damages in case of a fire?

PULSE WIDTH MODULATING VALVES

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Process glycol chillers

Optimal control for superior lighting performance

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Immersion Temperature Controller

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Tube-in-tube heat exchanger Type HE

Distributed By: M&M Control Service, Inc Building Technologies

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

Air Cooled Scroll Chiller

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves for ammonia Type TEA

Room thermostat with Auto Timer, independent DHW

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

LZT High efficiency air to water heat pumps with E.V.I. compressors

Conditioning your ambient, maximising your comfort.

Industrial cooling systems LT

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Air Cooled Packaged Systems AIRAH Back to Basics

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

Refrigeration Compressed Air Dryer Boreas Variopulse

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

SUBCRITICAL & TRANSCRITICAL SYSTEMS

DES IGN I T ALI A N O

DESIGO - Answers for infrastructure. Energy-efficient applications: h,x-controlled Economizer tx2. Application data sheet

AQUAHEAT ADVANCE SPLIT

Heating and D.h.w. Controller RVL482 Basic Documentation

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

DC1192 Input /Output module

SEMI-HERMETIC SCREW COMPRESSORS

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

Transcription:

Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure.

MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661.. and MVS661..N MVL661.. This fine-tuned valve series has an expansion capacity range of 29 to 737 kw. Wide range of application areas MVL661 and MVS661..N cover the three application areas of expansion, hot gas and suction throttle. As such, just one valve series covers all common safety refrigerants. With protection class IP65 (water jet protection), the valves can even be installed in food processing areas. Thanks to their piston construction and valve housing cast in one piece from CrNi steel, the MVL661 and MVS661..N are robust and maintenance-free. The minimum opening, in other words the bypass function for suction throttle, is selectable on the electronics housing. Type DN [mm] k vs [m3/h] Qo E [kw] Qo H [kw] Qo D [kw] MVL661.15-0.4 15 0.40 47 9.2 1.7 MVL661.15-1.0 1) 15 0.63 74 14 2.6 MVL661.15-1.0 15 1.0 117 23 4.2 MVL661.20-2.5 1) 20 1.6 187 37 6.6 MVL661.20-2.5 20 2.5 293 57 10 MVL661.25-6.3 1) 25 4.0 468 92 17 MVL661.25-6.3 25 6.3 737 144 26 MVL661.32-12 1) 32 8 2) 2) 33 MVL661.32-12 32 12 2) 2) 50 Qo E Refrigeration capacity in expansion applications Qo H Refrigeration capacity in hot gas bypass applications Qo D Refrigeration capacity in suction throttle applications Qo with R407C at to = 0 C, tc = 40 C and Δp = 0.5 bar 1) Valve stroke electronically limited to 63% 2) MVL661.32-12 is only approved for suction throttle applications 2

Expansion applications using MVL661 + MVS661..N + + Hot gas applications using MVL661 + MVS661..N + + Suction throttle applications using MVL661 + MVS661..N Bypass Innovative technology offers a host of user benefits The high-resolution stroke allows for precise evaporator control. The control performance is unique under all load conditions and extremely stable even in the short-stroke range. The fast positioning time of less than a second controls even complex systems with plate heat exchangers and small quantities of refrigerant safely and precisely. With four selectable control signals DC 0/2...10 V, 0/4...20 ma, the MVL661 and MVS661..N are compatible with the most common controllers. The stroke position feedback signal can be utilized for process monitoring. In the event of a power failure, the valves close thereby ensuring maximum safety. Accurate positioning thanks to the highresolution stroke allows precise capacity control. The internal stroke control loop compensates for non-linearity and hysteresis. The maximum permissible pressure difference Δp max of 25 bar and the maximum permissible operating pressure of 53 bar allow the use of many types of refrigerant and can be used in applications with high pressure difference between the high-pressure and low-pressure side of the refrigeration system. Economical operation Compared to thermostatic expansion valves, the amortization time is less then one year. This is thanks to precise superheat control under all load conditions. The integrated mechanical close function saves additional system components. The integrated valve electronics housing with selectable control signals simplifies installation and commissioning. And as only one valve is needed to cover expansion, hot gas and suction throttle applications, it is easier to manage parts storage. In addition, the electronics housing is integrated and included in the price. MVS661..N This valve was developed for ammonia refrigerant applications. An exchangeable valve insert allows various k vs values to be covered using a DN25 valve. For servicing, the valve insert can also be exchanged on site if the necessary precautions are taken. Highlights MVL661../MVS661..N Hermetically sealed Solder connection One valve type, 3 applications MVL661.. has 5 k vs values Fast positioning time (< 1 s) Selectable standard interface DC 0/2...10 V or 0/4...20 ma Exchangeable electronics housing Closed when deenergized (NC) MVL661.. special Ex protection edition available on request MVS661..N as MVL661.. plus Valve for ammonia and CO 2 applications Welding connection One size, 5 k vs values Exchangeable ASR.. valve inserts Exchangeable ASR inserts for MVS661..N: ASR0.16N = 0.16 m 3 /h ASR0.40N = 0.4 m 3 /h ASR1.0N = 1.0 m 3 /h ASR2.5N = 2.5 m 3 /h ASR6.3N = 6.3 m 3 /h 3

M3FB..LX M3FB..LX and M3FK..LX The M3FB..LX can be used as a diverting or straight-through valve for continuous capacity control in compression refrigerant systems and for heat recovery. Indirect hot gas bypass In this application, the control valve reduces the capacity of a compressor stage. The hot gas is fed directly to the evaporator and allows the capacity to be adjusted from 100% down to 0%. This application is suitable for large air conditioning systems where excessive temperature fluctuations occur between each compressor stage. In doing so, this ensures the system functions correctly under all load conditions. Indirect hot gas bypass also makes it possible to heat without requiring an additional heat exchanger. Application areas include ripening chambers or containers. In addition, the indirect hot gas application can be used for hot gas defrosting of cooling coils. Compared to mechanical hot gas valves, the M3FB..LX excels thanks to its more precise evaporation temperature and pressure control. Direct hot gas bypass The control valve reduces the capacity of a compressor stage. The gas is fed through to the suction line of the compressor and cooled by an injection valve. This application is suitable for larger air conditioning systems with multiple compressors. It allows a high evaporation pressure to be maintained with reduced capacity thereby preventing the cooling coils from frosting up. The application is similar to suction throttle control, but covers a wider capacity range. The M3FB..LX allows the suction pressure for the compressor to be controlled more accurately compared to using mechanical hot gas valves. 4

M3FK..LX Heat recovery Various applications using multiple condensers can be realized using the hot gas bypass valve. While the additional condenser or gas cooler removes heat according to demand, the unwanted heat is discharged via the main condenser. Typical applications include producing warm water and preheating of air. These applications save energy and costs when generating heat. The M3FK.LX can be used as a mixing or straight-through valve to continually regulate the capacity of condensers. It can be used either on the liquid or gas side. Assorted types of heat recovery system can be equipped with the condenser control valve. Compared to hot gas applications, much higher capacities can be controlled on the condensate side with a similarly sized valve. The diagram on the left shows the condensate control of an auxiliary condenser. This application is suitable for preheating, domestic hot water preparation or low-temperature heating systems. Up to 1000 kw can be controlled per valve. The diagram on the right side shows the gas-side control of condensers connected in series. This application is suitable for air reheaters. Two-way applications The nominal diameters 40 mm and 50 mm are also used as suction valves. In doing so, the lower port 2 is closed. Highlights M3FB..LX/M3FK..LX Hermetically sealed Positioning time < 1 s AB -> A/1-3 closed when deenergized High resolution and accuracy of control Selectable ZM.. electronics housing: DC 0...10 V, 4...20 ma, 0...20 V Phs For safety refrigerants M3FK..LX as an extension to the MVL661.. series, DN40 and DN50 for suction throttle applications 5

Proportional magnet for refrigerant valves Proportional magnet as an actuator for refrigerant valves. Over 30 years of experience For over 30 years, Siemens has been developing and producing refrigerant valves with magnetic actuators. Today, our range includes four valve ranges of 25 different types. The one thing they all have in common is the actuator technology: the ultra precise, permanent DC magnet. Environment and safety All our valves save energy in refrigeration systems thanks to precise control even in the partial load operation. The valves are hermetically sealed and are therefore safe for the environment. The magnetic plunger in all actuators is completely housed in a pressure tube. The coil is outside the refrigerant loop making the system hermetically sealed. The magnetic coil generates a magnetic field that is transmitted by the pressure tube causing the plunger to change position thus causing the valve to stroke. Consequently, refrigerant valves from Siemens neither have static nor dynamic seals which could allow refrigerant to escape into the environment in the event of damage. Proportional versus ON/OFF In its basic design, the proportional permanent DC magnet is similar to a solenoid valve that is controlled by pulse width modulation. However, it has considerable additional benefits: as the valves are continually adjusting, hydraulic hammering is prevented which would otherwise lead to noise, vibration or even system damage. A positive impact on service life is due to the fact that proportional solenoids do not need to utilize the valves full stroke. Proportional valves offer very good control even in the partial load operation. Solenoid valves controlled by pulse width modulation have a relatively high minimum throughput as the opening time cannot be controlled to as short a time as required. This makes control more difficult in the partial load. 6

PolyCool CPS40 superheat controller set Want to save energy and improve the performance of your refrigeration system? With the PolyCool superheat controller set CPS40, you can easily achieve energy savings of up to 25% and increase cooling capacity at the same time. Save time and energy The PolyCool superheat controller set CPS40 is impressive as it is simple to install and can be configured directly on site thanks to its integrated user interface. With the PolyCool superheat controller set, you can achieve energy savings of up to 25% through precise super heat control. The electronic expansion valve optimizes the refrigerant charge in the evaporator, enables smaller superheat. The higher evaporating pressure increases the COP of the system which leads to a reduction in energy consumption. Highlights Four capacity classes with a refrigeration capacity range between 20 740 kwh Safety switch-off for compressors Limitation of evaporating pressure (MOP) True superheat control through pressure and temperature monitoring Optimal control algorithm for minimum superheat Up to two independent superheat control loops Valve starting action adjustable in terms of time and degree of opening 7

Technical data Operating voltage AC 24 V/DC 20...30 V AC 24 V/DC 20...30 V Power consumption 22 VA 22 VA MVS661..N MVL661.... M3FB..LX.. M3FK..LX.. Control signal DC 0/2...10 V, 0/4...20 ma DC 0/2...10 V, 0/4...20 ma Positioning time < 1 s < 1 s < 1 s < 1 s Emergency positioning function Closed Closed AB-A closed 1->3 closed Position feedback DC 0/2 10 V, 0/4...20 ma DC 0/2 10 V, 0/4...20 ma Protection class IP65 IP65 Ambient temperature -25...+55 C -25...+55 C -40 +50 C -40...+50 C Installation position Upright to horizontal Upright to horizontal As desired As desired Permissible operating pressure 5300 kpa 4500 kpa 4300 kpa 3200 kpa Δp max control port 1->3 A->AB Δp max bypass port 1->2 Control port leakage rate 1->3/A->AB Bypass port leakage rate 1->2 2500 kpa Max. 0.002% 2500 kpa DN32: 200 kpa Max. 0.002% See table 1 800 kpa Max. 0.05% Max. 0.5% gas: 800 kpa liquid: 200 kpa gas: 800 kpa liquid: 200 kpa Max. 0.05% Max. 0.5% Medium temperature -40...+120 C -40...+120 C -40 +120 C -40...+120 C Valve characteristic Linear Linear Linear Linear Stroke resolution ΔH/H100 1:1000 1:1000 1:200 1:200 DN [mm] 25 15-32 15-32 15-50 k vs [m 3 /h] 0.16-6.3 0.4-12 0.6-12 0.6-30 Valve body Stainless steel Stainless steel Steel Steel Inner fitting Stainless steel, teflon Stainless steel, brass, teflon Brass, stainless steel Brass, stainless steel Data sheet CE2N4716 CA2N4714 CA2N4721 CA2N4722 a) b) b) a) DN32 only for suction gas applications b) ZM electronic interface must be ordered separately. See table 2 Table 1 Δp max Table 2 ZM101/A ZM121/A ZM111 Typ [kpa] Operating voltage AC 24 V AC 24 V M3FB15LX06/A 2200 M3FB15LX15/A 2200 Positioning signal DC 0...10 V 4...20 ma Phs 0...20 V Protection class IP54 IP54 IP54 M3FB15LX/A 2200 M3FB20LX/A 1800 M3FB25LX/A 1200 M3FB32LX 800 8

9

Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel +41 41 724 24 24 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Siemens Switzerland Ltd, 2013 Order no. 0-92308-en 0,351302 Answers for infrastructure. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure. www.siemens.com/buildingtechnologies