Product Catalog Split System Air Conditioners Odyssey

Similar documents
Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Split System Heat Pumps

Product Data. Split System Cooling H-EN. January 2017

Product Catalog. Split System Air Conditioners Odyssey SSP-PRC023H-EN. Heat Pump Condenser 6 to 20 Tons 60 Hz Air Handler 5 to 20 Tons 60 Hz

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Split System Heat Pump

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data Split System Cooling

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling E-EN. November 2016

Commercial High-Efficiency Condensing Units

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Split System Heat Pump Condensers

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Split System Cooling

MAC N-407 Air-Cooled Chiller

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data. Split System Heat Pump D-EN. February 2016

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

16 SEER TWO-STAGE AIR CONDITIONERS

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

AIR COOLED SPLIT SYSTEMS LIGHT COMMERCIAL RANGE UN-PRC001-EN

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Product Data. Split System Heat Pump A-EN. March 2016

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Product Data. Split System Cooling A. November 2013

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

13 SEER CONDENSING UNITS

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Condensing Units & Air Handlers

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

R4H4. Product Specifications

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Split System Cooling Product Data

PRODUCT SPECIFICATIONS

R4H4. Product Specifications

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

PACKAGE AIR CONDITIONER

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

13 GEP A L P - 1 A

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Split System Cooling Product Data

Unit Features & Benefits RQPM/RQRM Series

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

C13-Series Engineering Guide

Product Catalog Gas Heating Products: Indoor and Outdoor Units

Variable Speed Convertible Air Handler 5 Ton

Split System Cooling Product Data

13 SEER CONDENSING UNITS & AIR HANDLERS

RGE 13 A T - 1 A

Split System Cooling Product Data

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

TECHNICAL SPECIFICATIONS

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

PAJ3. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

WCH5**4. Product Specifications

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Split System Heat Pump Product Data

T P A 120 S 4 S N 1 Y

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

N4A6. Product Specifications

MERIT Series R-410A - Upflow / Horizontal

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Indoor Air Handlers with Compressors MVS and MVW

N4H4. Product Specifications

Variable Speed Convertible Air Handler 2 1/2 Ton

Transcription:

Product Catalog Split System Air Conditioners Odyssey R-22 Dry Charge HeatPumpCondenser 7.5, 10, 15 and 20 Tons 60 Hz July 2018 SSP-PRC027H-EN

Introduction Wide network availability Flexible applications Easy to install Built-in reliability Easy to service Trane s reputation for providing quality comfort solutions continues with the development of the next generation Light Commercial Odyssey Split Systems. With wide network availability, flexible applications, installation ease, built-in reliability and easy servicing, Odyssey will meet any number of customer applications. Add to that Trane s outstanding customer service and you have the formula to make Odyssey the clear choice for continued customer satisfaction. A broad distribution network provides owners, maintenance personnel, contractors, etc., the meansto get theirhands onequipment when they needit.whetherit s anemergency replacement or a new construction project in its infancy stages, Odyssey products meet an array of needs attheright time and rightprice. No matter what the application, Odyssey provides the solution. A broad array of models and tonnages are available with single or dual compressors, single or dual circuits and numerous accessories. Condensing units can be installed on the ground or on a rooftop along with extended piping runs, while air handlers can be free discharge on the ground or horizontally suspended with long duct runs from a ceiling. Should application challenges arise, Odyssey delivers. Small footprints and low weights combined with factory installed components like TXVs, filter driers, etc., reduce installation time and cost. Colored and numbered wiring and factory tested units make Odyssey the right choice. Keeping in mind that productivity only occurs when equipment is operational,trane has taken the steps to ensure that Odyssey is up and running. Early indicators such as phase/reversal monitors and loss of charge protection provide diagnostics which prevent failure and provide years of worry-free service and operation. When preventive maintenance or service is required, technicians will find efficient access to both air handlers and condensers. Panels provide complete, easy access coupled with standardized cabinets in which all components are located in proximity. Odyssey s improved design results in minimum service times and costs. With these capabilities, Odyssey provides customers high efficiency and superior performance for the best all-around value in the market today. Copyright Trademarks This documentand theinformationin itare thepropertyof Trane,and may notbeused or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. All trademarks referenced in this document are the trademarks of their respective owners. 2018 Ingersoll Rand SSP-PRC027H-EN

Revision History Weights, dimensional drawings have been updated to reflect that service valves are no longer a factory installed feature. Running edits included. Introduction SSP-PRC027H-EN 3

Table of Contents Accessories... 5 Heat Pump Condenser... 5 ModelNumberDescription... 6 Heat Pump Condenser... 6 GeneralData... 7 PerformanceData... 8 ElectricalData... 12 DimensionalData... 13 Cooling Condenser... 13 Heat Pump Condenser... 13 Weights... 16 Heat Pump Condenser... 16 4 SSP-PRC027H-EN

Accessories Heat Pump Condenser Table 1. TWA Accessories Model Used With Coil (Hail/Vandal) Guard BAYGARD058* TWA0902*A BAYGARD060* TWA1202*A BAYGARD061* TWA1802*D, TWA2402*D Rubber Isolators BAYISLT005* (black) TWA0902*A, TWA1202*A BAYISLT009* (red) TWA1802*D BAYISLT010* (green) TWA2402*D Steel Spring Isolators BAYISLT023* (red) TWA0902*A, TWA1202*A BAYISLT024* (black) TWA1802*D BAYISLT025* (yellow) TWA2402*D Service Valve Kit BAYVALV001A TWA0902*A, TWA1202*A BAYVALV006A TWA1802*D, TWA2402*D Low Ambient On/Off Fan Control (External mount, small cabinets) (a) (b) (c) BAYLOAMU01* (External Mount, small cabinets) (d) (all voltages) TWA0902*A BAYLOAMU02* (Internal mount, large cabinets) (all voltages) TWA1202*A, TWA1802*D, TWA2402*D Cycles fan on/off (no modulating). Quantity of 1 required for each fan (2 total for 15 ton and larger). ReliaTel requires onboard EDC function to be disabled when BAYLOAM is used, remove OA sensor from terminal J8-1&2 Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures. (a) (b) (c) (d) SSP-PRC027H-EN 5

Model Number Description Heat Pump Condenser Digit 1 3 Unit Function TWA = Split System Heat Pump Digit 4 6 Tonnage 090 = 7.5 Tons (60Hz) 120 = 10 Tons (60Hz) 180 = 15 Tons (60Hz) 240 = 20 Tons (60Hz) Digit 7 Refrigerant 2 = R-22 Digit 8 Voltage 3 = 208-230VAC - 3 PH (60Hz) 4 = 460VAC - 3 PH (60Hz) Digit 9 Refrigeration Circuit/Stage A = 1 Compressor/1 Line/1 Stage (Single) D = 2 Compressors/2 Line/2 Stage (Duals) Digit 10 Major Design Sequence A = Rev A Digit 11 Minor Design Sequence B = Rev B Digit 12 13 Service Digits 00 = 00 Digit 14 Efficiency Generation A = Generation A Digit 15 Controls R = ReliaTel Digit 16 None 0 = None Digit 17 Coil Protection 0 = Standard Coil Digit 18-20 None 0 = None Digit 21 Communications Options 0 = No Option Digit 22-40 None 0 = None 6 SSP-PRC027H-EN

General Data Table2. General datafor 7.5-20 tonheatpump, 60 Hz Compressor 7.5 Tons 10 Tons 15 Tons 20 Tons Single Compressor Dual Compressor TWA1202*A* TWA1802*D* Single Compressor TWA0902*A* Dual Compressor TWA2402*D* Type Scroll Scroll Scroll Scroll No./Tons 1/6.9 1/8.6 2/6.9 2/8.6 System Data No. Refrigerant Circuits 1 1 2 2 Suction Line (in.) OD 1 3/8 1 3/8 1 3/8 1 3/8 Liquid Line (in.) OD 5/8 1/2 1/2 5/8 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) OD 0.375 0.375 0.375 0.375 Face Area (sq ft) 19.24 29.02 52.60 52.60 Rows/FPI (Fins per inch) 2/18 2/18 2/18 2/18 Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter (in.) 1/26 1/28 2/28 2/28 Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM 6,530 9,800 19,500 19,500 No. Motor/HP 1/0.5 1/1 2/1 2/1 Motor RPM 1,100 1,100 1,100 1,100 Refrigerant Charge (Field Supplied) lbs of R-22 20.6 27.9 47.1 47.0 Shipping Dimensions HxWxD (in.) 46.1 x 45 x 38 52.1 x 55 x 42 51.1 x 96 x 48 51.1 x 96 x 48 SSP-PRC027H-EN 7

Performance Data Table 3. Gross cooling capacities (MBH) 7.5 tons TWA0902*A condensing unit only(ip) Outdoor Temp ( F) 65 75 85 95 105 115 Suction Temperature ( F) 30 35 40 45 50 55 Head Press (psig) 161.6 172.5 178.6 185.2 192.0 199.2 Capacity (Btuh/1000) 75.4 83.5 92.3 101.5 111.1 121.0 Unit Power (kw) 4.8 5.0 5.1 5.3 5.5 5.6 Head Press (psig) 190.7 196.7 203.0 209.7 216.7 224.1 Capacity (Btuh/1000) 71.3 79.2 87.7 96.4 105.5 114.8 Unit Power (kw) 5.3 5.5 5.6 5.8 6.0 6.2 Head Press (psig) 217.1 223.3 230.0 237.0 244.3 252.0 Capacity (Btuh/1000) 67.5 75.0 83.0 91.3 99.9 108.8 Unit Power (kw) 5.8 6.0 6.1 6.3 6.5 6.7 Head Press (psig) 246.4 252.9 259.7 266.9 274.5 282.3 Capacity (Btuh/1000) 63.6 70.8 78.3 86.2 94.4 102.8 Unit Power (kw) 6.4 6.6 6.7 6.9 7.1 7.3 Head Press (psig) 278.2 285.0 292.0 299.4 307.2 315.2 Capacity (Btuh/1000) 59.7 66.5 73.6 81.0 88.7 96.7 Unit Power (kw) 7.0 7.2 7.4 7.6 7.8 8.0 Head Press (psig) 312.8 319.8 327.1 334.6 342.5 350.7 Capacity (Btuh/1000) 55.7 62.1 68.9 75.8 83.1 90.5 Unit Power (kw) 7.7 7.8 8.0 8.2 8.4 8.6 Head Press (psig) 350.1 357.3 364.7 372.5 380.5 388.8 Capacity (Btuh/1000) 51.6 57.7 64.1 70.6 77.3 84.3 Unit Power (kw) 8.4 8.6 8.7 8.9 9.1 9.3 Note: Performance data calculated at 15 F subcooling and 15 F superheat and does not include capacity loss due to refrigerant lines. Figure 1. TWA0902*A capacity curve Capacity Curves - Condensing Unit Only 155 Gross Cooling Capacity (MBH) 145 135 115 105 95 85 75 65 55 45 INDOOR COIL FROST LIMIT COMPRESSOR HIGH SUCTION LIMIT 65 75 85 95 105 115 35 25 30 35 40 45 50 55 60 65 70 75 Saturated Suction Temperature (F) 8 SSP-PRC027H-EN

PerformanceData Table 4. Gross cooling capacities (MBH) 10 tons TWA1202*A condensing unit only(ip) Outdoor Temp ( F) 65 75 85 95 105 115 Suction Temperature ( F) 30 35 40 45 50 55 Head Press (psig) 166.3 172.1 178.4 185.1 192.3 199.9 Capacity (Btuh/1000) 98.4 108.8 119.9 131.5 143.8 156.6 Unit Power (kw) 7.1 7.3 7.5 7.8 8.0 8.3 Head Press (psig) 189.0 194.9 201.2 207.9 215.1 222.7 Capacity (Btuh/1000) 95.0 105.1 115.8 127.1 138.9 151.3 Unit Power (kw) 7.6 7.8 8.0 8.3 8.5 8.8 Head Press (psig) 213.9 219.9 226.3 233.1 240.4 248.1 Capacity (Btuh/1000) 91.2 101.0 111.3 122.2 133.6 145.6 Unit Power (kw) 8.1 8.4 8.6 8.8 9.1 9.3 Head Press (psig) 241.6 247.7 254.3 261.2 268.5 276.2 Capacity (Btuh/1000) 87.2 96.5 106.5 117.0 127.9 139.4 Unit Power (kw) 8.8 9.0 9.2 9.5 9.7 10.0 Head Press (psig) 272.0 278.2 284.8 291.7 299.1 306.9 Capacity (Btuh/1000) 82.8 91.8 101.2 111.3 121.8 132.7 Unit Power (kw) 9.6 9.8 10.0 10.2 10.5 10.7 Head Press (psig) 305.1 311.3 317.9 324.9 332.3 340.1 Capacity (Btuh/1000) 78.1 86.7 95.7 105.2 115.2.6 Unit Power (kw) 10.4 10.6 10.8 11.0 11.3 11.5 Head Press (psig) 340.8 347.1 353.8 360.8 368.2 375.9 Capacity (Btuh/1000) 73.2 81.3 89.9 98.8 108.2 118.0 Unit Power (kw) 11.3 11.5 11.7 12.0 12.2 12.4 Note: Performance data calculated at 15 F subcooling and 15 F superheat and does not include capacity loss due to refrigerant lines. Figure 2. TWA1202*A capacity curves Capacity Curves - Condensing Unit Only 175 Gross Cooling Capacity (MBH) 160 145 130 115 100 85 70 INDOOR COIL FROST LIMIT COMPRESSOR HIGH SUCTION LIMIT 65 75 85 95 105 115 55 25 30 35 40 45 50 55 60 Saturated Suction Temperature (F) SSP-PRC027H-EN 9

PerformanceData Table 5. Gross cooling capacities (MBH) 15 tons TWA1802*D condensing unit only(ip) Outdoor Temp ( F) 65 75 85 95 105 115 Suction Temperature ( F) 30 35 40 45 50 55 Head Press (psig) 149.9 154.2 158.9 164.0 169.3 175.0 Capacity (Btuh/1000) 148.9 167.0 186.2 206.9 228.7 251.4 Unit Power (kw) 10.4 10.6 10.9 11.1 11.4 11.6 Head Press (psig) 172.4 176.8 181.5 186.6 192.0 197.6 Capacity (Btuh/1000) 141.1 158.4 176.8 196.3 217.1 238.9 Unit Power (kw) 11.3 11.5 11.7 12.0 12.3 12.6 Head Press (psig) 197.3 201.8 206.6 211.6 217.0 222.7 Capacity (Btuh/1000) 133.2 149.7 167.3 185.8 205.4 226.2 Unit Power (kw) 12.2 12.4 12.7 13.0 13.3 13.6 Head Press (psig) 224.8 229.4 234.3 239.5 245.0 250.8 Capacity (Btuh/1000).1 140.9 157.6 175.4 194.0 213.5 Unit Power (kw) 13.2 13.5 13.8 14.1 14.4 14.7 Head Press (psig) 255.2 259.9 264.9 270.2 275.8 281.6 Capacity (Btuh/1000) 116.8 131.9 147.9 164.8 182.5 201.0 Unit Power (kw) 14.4 14.7 15.0 15.3 15.6 15.9 Head Press (psig) 288.4 293.2 298.3 303.7 309.3 315.2 Capacity (Btuh/1000) 108.4 122.8 138.1 154.1 170.9 188.4 Unit Power (kw) 15.7 15.9 16.2 16.5 16.9 17.2 Head Press (psig) 324.5 329.5 334.7 340.1 345.8 351.7 Capacity (Btuh/1000) 99.9 113.6 128.1 143.3 159.2 175.7 Unit Power (kw) 17.1 17.3 17.6 17.9 18.2 18.6 Note: Performance data calculated at 15 F subcooling and 15 F superheat and does not include capacity loss due to refrigerant lines. Figure 3. TWA1802*D capacity curves Capacity Curves - Condensing Unit Only 275 260 Gross Cooling Capacity (MBH) 245 230 215 200 185 170 155 140 110 95 INDOOR COIL FROST LIMIT COMPRESSOR HIGH SUCTION LIMIT 65 75 85 95 105 115 80 25 30 35 40 45 50 55 60 Saturated Suction Temperature (F) 10 SSP-PRC027H-EN

PerformanceData Table 6. Gross cooling capacities (MBH) 20 tons TWA2402*D condensing unit only(ip) Outdoor Temp ( F) 65 75 85 95 105 115 Suction Temperature ( F) 30 35 40 45 50 55 Head Press (psig) 164.1 169.9 176.1 182.8 189.9 197.5 Capacity (Btuh/1000) 196.0 217.1 239.8 263.8 288.9 315.2 Unit Power (kw) 14.3 14.8 15.2 15.7 16.2 16.8 Head Press (psig) 186.5 192.3 198.6 205.3 212.4 219.9 Capacity (Btuh/1000) 187.6 208.1 229.8 253.0 277.4 302.8 Unit Power (kw) 15.3 15.7 16.2 16.7 17.2 17.7 Head Press (psig) 211.3 217.1 223.4 230.1 237.3 245.0 Capacity (Btuh/1000) 178.5 198.3 219.2 241.4 264.8 289.3 Unit Power (kw) 16.4 16.8 17.3 17.8 18.3 18.8 Head Press (psig) 238.7 244.7 251.1 257.8 265.1 272.7 Capacity (Btuh/1000) 168.8 187.8 208.0 229.1 251.6 275.1 Unit Power (kw) 17.7 18.2 18.6 19.1 19.5 20.0 Head Press (psig) 268.9 275.0 281.4 288.2 295.4 303.1 Capacity (Btuh/1000) 158.4 176.7 195.9 216.2 237.4 259.9 Unit Power (kw) 19.2 19.6 20.1 20.5 21.0 21.5 Head Press (psig) 301.8 307.9 314.4 321.3 328.5 336.2 Capacity (Btuh/1000) 147.6 164.9 183.3 202.5 222.7 243.8 Unit Power (kw) 20.9 21.3 21.7 22.2 22.6 23.1 Head Press (psig) 337.5 343.7 350.2 357.1 364.1 371.6 Capacity (Btuh/1000) 136.2 152.7 170.0 188.2 207.1 226.7 Unit Power (kw) 22.7 23.1 23.5 24.0 24.4 24.8 Note: Performance data calculated at 15 F subcooling and 15 F superheat and does not include capacity loss due to refrigerant lines. Figure 4. TWA2402*D capacity curves Capacity Curves - Condensing Unit Only Gross Cooling Capacity (MBH) 350 335 320 305 290 275 260 245 230 215 200 185 170 155 140 INDOOR COIL FROST LIMIT 110 25 30 35 40 45 50 55 60 Saturated Suction Temperature (F) COMPRESSOR HIGH SUCTION LIMIT 65 75 85 95 105 115 SSP-PRC027H-EN 11

Electrical Data Table 7. Electrical characteristics compressor and condenser fan motors heat pumps 60Hz Tons 7.5 10 15 20 Unit Model Number No. Volts Phase Compressor Motor Compressor 1 Compressor 2 Condenser Fan Motor Amps RLA LRA RLA LRA No. Volts Phase FLA LRA Amps Amps Amps Amps (Ea.) (Ea.) TWA09023A 1 208-230 3 22.4 164 N/A N/A 1 208-230 1 3.1 8.1 TWA09024A 1 460 3 10.9 100 N/A N/A 1 460 1 1.6 3.8 TWA12023A 1 208-230 3 30.1 231 N/A N/A 1 208-230 1 5.0 14.4 TWA12024A 1 460 3 15.5 114 N/A N/A 1 460 1 2.5 5.8 TWA18023D 1 208-230 3 22.4 164 22.4 164 2 208-230 1 5.0 14.4 TWA18024D 1 460 3 10.9 100 10.9 100 2 460 1 2.5 5.8 TWA24023D 1 208-230 3 30.1 231 30.1 231 2 208-230 1 5.0 14.4 TWA24024D 1 460 3 15.5 114 15.5 114 2 460 1 2.5 5.8 Note: Electrical characteristics reflect nameplate values and are calculated in accordance with culus specifications. Table8. Unit wiring heat pumps 60Hz Tons 7.5 10 15 20 Unit Model Number Unit Operating Voltage Range Minimum Circuit Ampacity Maximum Fuse or HACR Circuit Breaker Size TWA09023A 187-253 31 50 TWA09024A 414-506 15 25 TWA12023A 187-253 43 70 TWA12024A 414-506 22 35 TWA18023D 187-253 60 80 TWA18024D 414-506 30 40 TWA24023D 187-253 78 100 TWA24024D 414-506 40 50 Note: HACR type circuit breaker per NEC. 12 SSP-PRC027H-EN

Dimensional Data Cooling Condenser Heat Pump Condenser Figure 5. 7.5 ton heat pump, single compressor SEE NOTE 3 SERVICE PANEL NOTES: 1. ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY. 2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36" ( 914.4) FROM WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72" (1828.8). RECOMMENDED SERVICE CLEARANCE 48" (1219.2) 3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" (2540) MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT 4. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING) SEE NOTE 4 HAIL GUARD (OPTIONAL) SERVICE CLEARANCE 48" (1219.2) (SEE NOTE 2 FOR CLEARANCE) HAIL GUARD (OPTIONAL) LINE VOLTAGE CONTROL WIRING 35 15/16" (912.8) WITH HAIL GUARD 33 15/16" (862) SEE NOTE 1 REFRIGERANT ACCESS LIQUID LINE SUCTION LINE 5 5/8" (143) 8 5/16" (211.1) 36 3/8" (923.9) 29 13/16" (757.2) 1/16" (1.6) SERVICE PANEL 6" (152.4) 21 11/16" (550.9) 33 13/16" (858.8) SERVICE PANEL SIDE 6" (152.4) 39 3/16" (995.4) 26 15/16" (684.2) 14 3/8" (365.1) 3 1/16" (77.8) 2" (50.8) 41 1/16" (1043) 42 1/8" (1070) WITH HAIL GUARD 3" (76.2) 7/16" (11.1) DIA. ISOLATOR MOUNTING HOLES (OUTSIDE HOLES - 4 PLACES) 40 3/4" (1035) 34 3/4" (882.7) BOTTOM OF UNIT 4 3/16" (106.4) 1 13/16" (46) 27 11/16" (703.3) SSP-PRC027H-EN 13 2 5/16" (58.7)

Dimensional Data Figure 6. 10 ton heat pump, single compressor SERVICE PANEL SEE NOTE 3 NOTES: 1. ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY. 2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36" (914.4) FROM WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72" (1828.8). RECOMMENDED SERVICE CLEARANCE 48" (1219.2) 3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" (2540) MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT 4. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING) SEE NOTE 4 HAIL GUARD (OPTIONAL) SERVICE CLEARANCE 48" (1219.2) (SEE NOTE 2 FOR CLEARANCE HAIL GUARD (OPTIONAL) 4 1/4" (108) 39 15/16" (1014.4) 1 1/4" (31.7) WITH HAIL GUARD LINE VOLTAGE 37 15/16" CONTROL WIRING (963.6) SEE NOTE 1 REFRIGERANT ACCESS 5 9/16" (141.3) 8 1/4" (209.5) 42 5/16" 35 3/4" (1074.7) (908) SERVICE PANEL 44 3/4" (1136.6) 32 7/8" (835) 14 5/16" (363.5) LIQUID LINE SUCTION LINE 4" (101.6) 4 3/8" (111.1) 1/16" (1.6) 6" (152.4) 25 11/16" (652.5) 6" (152.4) 1 13/16" (46) 37 11/16" (957.3) 2 7/8" (73) 50 15/16" (1293.8) 3" (76.2) SERVICE PANEL SIDE 51 15/16" (1319.2) WITH HAIL GUARD 7/16" (11.1) DIA. ISOLATOR MOUNTING HOLES (OUTSIDE HOLES - 4 PLACES) 50 3/4" (1289) 44 3/4" (1136.6) BOTTOM OF UNIT 2 3/16" (55.6) 3 13/16" (96.8) 31 11/16" (805) 1 11/16" (42.9) 14 SSP-PRC027H-EN

DimensionalData Figure 7. 15-20 ton heat pump, dual compressor SEE NOTE 2 NOTES: 1. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36" (914.4) FROM WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72" (1829). RECOMMENDED SERVICE CLEARANCE 48" (1219.2) 2. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" (2540) MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT 3. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING). SEE NOTE 3 HAIL GUARD (OPTIONAL) SERVICE CLEARANCE 48" (1219.2) (SEE NOTE 1 FOR CLEARANCE) DETAIL A SERVICE PANEL 46" (1168.4) WITH HAIL GUARD 95 7/16" (2424.112) WITH HAIL GUARD 44 3/16" (1122.4) HAIL GUARD (OPTIONAL) HAIL GUARD (OPTIONAL) 45 1/8" (1146.2) SERVICE PANEL 93 5/16" (2370.1) 41 3/8" (1051) 1/16" (1.6) 9" (228.6) 25 11/16" (652.5) 9" (228.6) 7/16" (11.1) ( DIA. ISOLATOR MOUNTING HOLES (OUTSIDE HOLES - 4 PLACES) SERVICE PANEL SIDE CONTROL WIRING LINE VOLTAGE 9 1/4" (235) 6 13/16" (173) 1 3/16" (30.2) REFRIGERANT ACCESS 41 5/8" 39 7/8" (1057.3) (1012.8) BOTTOM OF UNIT 36 7/8" (936.6) 41 1/2" (1054.1) 14 1/2" 14 5/8" 12 5/8" (368.3) (371.5) (320.7) 3" (76.2) 2 3/16" 6 13/16" 87" (55.6) (173) (2210) 93" (2362.2) 5 5/8" (143) 4 1/4" (108) SUCTION LINES FRONT DETAIL A DIMENSIONAL DETAIL LIQUID LINES 15/16" (23.8) 3 11/16" (94) 6 5/16" (160.3) SSP-PRC027H-EN 15

Weights Heat Pump Condenser Table9. TWA unitand corner weights lbs(60hz) Tons Model No. Shipping Max (lbs) Net Max (lbs) Corner Weights 1 2 3 4 7.5 TWA0902*A 397 339 116 86 58 79 10 TWA1202*A 482 437 126 121 72 118 15 TWA1802*D 920 762 201 191 181 190 20 TWA2402*D 1003 845 253 265 147 181 Figure 8. TWA0902*A, 1202*A #3 Figure 9. TWA1802*D,TWA2402*D #4 #1 #4 #1 #2 #3 SERVICE ACCESS #2 SERVICE ACCESS SERVICE ACCESS LIFTING HOLES (BOTH SIDES) LIFTING HOLES (BOTH SIDES) 16 SSP-PRC027H-EN

Notes SSP-PRC027H-EN 17

Notes 18 SSP-PRC027H-EN

Notes SSP-PRC027H-EN 19

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. SSP-PRC027H-EN 10 Jul 2018 Supersedes SSP-PRC027G-EN (March 2018) 2018 Ingersoll Rand