P R O D U C T D ATA S H E E T

Similar documents
P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

IGD.CO.UK

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Xgard. Fixed detectors For flammable, toxic or oxygen gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

OLC(T) 100 FIXED GAS DETECTOR

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Lamp Supply (Recommended)

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

MICROpeL 75 Combustible Gas Sensor Part Number: PM

ESD3000 ESD200 Combustible / Toxic Gas Detector

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Dräger PEX 3000 Flammable Gas Detection

3M Oldham OLCT 100. Description. Fixed Gas Detector

Dräger PIR 3000 Detection of flammable gases and vapours

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ESD500. ESD500 Combustible / Toxic Gas Detector

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Sieger Apex. Flexibility that meets your requirements

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

ALTAIR 5X Multigas Detector Product Specification

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

IR15 Dual Gas Series Datasheet

Dräger Polytron 5700 IR Detection of flammable gases and vapours

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

SIL 2. Ultima X Series Gas Monitors CERTIFIED

PREMIER PLATINUM INFRARED GAS SENSOR

GAS DETECTION International Gas Detectors CH4 NO

IRceL CH4 Methane (CH 4

IR1 Single Gas Series Datasheet

GAS DETECTOR ST400EC PART.NO

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Technical data sheet TDS0034

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

INSTRUCTION MANUAL (ATEX / IECEx)

IR25 Dual Gas Series Datasheet

ALTAIR 5X Multigas Detector

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Dräger X-am 7000 Multi-Gas Detection

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

Dräger Polytron 8200 Stationary gas detector (CatEx)

APPLICATION DATA SHEET

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GAS ANALYSIS / DETECTION Gas Detector

SIMRAD GD10PE IR GAS DETECTOR

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Installation & User Manual

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ESD3000IR ESD3000IR. Infrared Gas Detector

Model D12-IR. Digital Gas Transmitter...

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

Dräger Polytron SE Ex Fixed Gas Detector

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Dräger Polytron 8700 IR Detection of flammable gases and vapors

G-TECTA TM. Portable Gas Detection Instruments

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

SIMRAD GD10 IR GAS DETECTOR

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

VQ500 Series Combustible Gas Detector Elements

Dräger PIR 7000 Flammable Gas Detection

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Transcription:

P R O D U C T D T S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors ccessories Series Gas Detectors 4-0m Device and 3 Wire ddressable Versions Compact Size EExd Certified TEX Certified Ingress Protection IP66 vailable as: Wire Toxic Gas Detector Wire Oxygen Sensor 3 Wire Infra Red Flammable Gas Detector 3 Wire Infra Red CO Gas Detector The Tocsin 10 series of gas detectors are TEX approved sensors which incorporate micro processor technology to give a stable 4-0m process signal output. The addressable option allows extensive reductions in cost of installation through material and labour savings. The in built processor can be used to pre-calibrate the sensor prior to installation. range of sensing technologies can be incorporated into the housing to provide the most appropriate detection method. vailable sensor types include Infra red and Electrochemical and PID devices. General Specification Power supply Electrical Outputs Temperature Humidity Ingress Protection Housing Material Protection Concept Dimensions (mm) Mounting Thread Weight 18 to 8V DC and 3 Wire 4-0m -10 C to +55 C 15 to 90% RH non-condensing IP66 Stainless Steel 316 S16 Flameproof 50 Diameter x 80 Length M0 x 1.75 514 grams (Toxic Gases, Oxygen, PID) 550 grams (Infra Red) HSCO SOCO SK 6TS TEX pproved IECEX pproved Ex db IIC T6 Gb Ta = -0 to +40 C Ex db IIC T5 Gb Ta = -0 to +55 C IECEx EXV16.0003X Rating W ExVeritas 16TEX 0141X Fax: +44 (0) 161 484 345

EC Declaration of Conformity Issuers name and address: Oliver Limited of Infra Red point flammable hydrocarbon gas detector certified for use in potentially explosive atmospheres Crosby St,, United Kingdom re in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. 004/108/EC 94/9/EC EMC Directive TEX Directive nd that the standards and/or technical specifications referenced below have been applied or considered. EN 60079-0:01 EN 60079-1:014 EN 60079-31:014 EN 6141-0:006 EN 6141-1:004 EN 61779-1:000 EN 5071:010 EN 61000-6-: 005 EN 61000-6-4/007 EN 61000-3-/:009 EN 61000-3-3: 008 Technical File references Equipment for use in explosive atmospheres. General requirements Equipment for use in explosive atmospheres. Flameproof enclosures 'd Equipment for use in explosive atmospheres. Housing Markings Electrical apparatus for use in the presence of combustible dust. General Requirements Electrical apparatus for use in the presence of combustible dust. Protection by enclosures "td" Electrical apparatus for the detection and measurement of flammable gases Electrical apparatus for the detection and measurement of combustible gases, toxic gases or Oxygen: requirements and tests for apparatus using software and or digital technologies. Excluding requirements for SIL EMC Generic standards. Immunity for industrial environments EMC Generic standards. Emission standard for industrial environments EMC Limits. Limits for harmonic current emissions (equipment input current 16 per phase) EMC Limits. Limitation of voltage changes, voltage fluctuations and flicker in public lowvoltage supply systems, for equipment with rated current 16 per phase T10-TF9 Technical construction File D197 TEX pproval Document File TEX pproved IECEX pproved Product Markings Serial Number: xxxxxxyear 585 Oliver Limited Operate and Independently assessed TEX/IECEX QN. Oliver Limited operate an independently assessed ISO9001:008 Quality Management System. Quality ssurance Certificate Number ExVeritas 16PQN0014 Quality ssurance Notification Number: 585 ExVeritas, Units 16-18, benbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ Ex db IIC T6 Gb Ta = -0 to +40 C Ex db IIC T5 Gb Ta = -0 to +55 C IECEx EXV16.0003X Rating W ExVeritas 16TEX 0141X Quality Management Certificate Number FS 646773 Testing gency: TUV - SUD Octagon House Concorde Way PO 15 5RL Fareham BSI ssurance UK LTD, Chiswick High Road, London W4 4L UK IECEX Certificate can be checked on-line at http://iecex.iec.ch/iecex/iecexweb.nsf/41ce8815c53a3afc157a1e00576486/9486b8f805dc1047c157f48005165c0?opendocument TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued by: Oliver Limited,, SK 6TS, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:010 Name ndrew J Collier M.I.O.D Position: Managing Director Date: HSCO SOCO SK 6TS 10.June 016 Declaration Ref: 10CE-4 Fax: +44 (0) 161 484 345

Toxic, Flammable & Oxygen Gas Detectors Sensor type Flammable Gases Infra-Red Point Basic Part Number Suffix For ddressable Sensor 5107901 Min Range 0-100%LEL 0-100%Vol Methane Propane n-butane n-pentane n-hexane Carbon Dioxide Infra-Red Point Max Range 0-3000ppm 0-5000ppm Manufactured Pellistors 511701 0-% 0-5% 0-100% MKIII MKIV & Type B Poison Resistant Carbon Monoxide 5107101 0-100ppm 0-4000ppm High Reliability Nitric Oxide 5106801 Field Proven Nitrogen Dioxide 5106301 0-0ppm Hydrogen Cyanide 510701 0-10ppm 0-00ppm Chlorine (safe area only non TEX) 5106601 Hydrogen Sulphide 5105501 0-10ppm 0-5000ppm mmonia 5107001 0-100ppm 0-500ppm Oxygen 5106701 0-5% 0-5% Sulphur Dioxide 5106401 Hydrogen Chloride 5106101 Hydrogen 5106901 0-00ppm 0-000ppm Methanol 511801 0-00ppm 0-00ppm Infra Red Gas Detectors Electrochemical Gas Detectors HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345

Infra Red Point Gas Detectors The Tocsin 10IR series of gas detectors uses the proven Non-Dispersive (NDIR) principle to detect and monitor the presence of gases. The detectors are supplied as pre-calibrated units with linear 4-0m outputs. If necessary the detector head can be field calibrated or reconfigured for different gases or ranges using its inbuilt serial port and separate data terminal. The infra red detectors employed have been field proven over many years use resulting in a series of detector heads with excellent stability and reliability in the most arduous conditions. The detector heads have their own control software which continually monitors the head performance. This ensures that in the unlikely event that a fault occurs it is detected and reported immediately. Using the inbuilt serial port this series of detector heads can be integrated onto addressable systems such as the Tocsin 700 or 900 control panels allowing sensors to be daisy chained for ease of installation and operation. LONG MTBF EXTENDED CLIBRTION PERIODS LL STINLESS STEEL CONSTRUCTION DDRESSBLE SERIL PORT CN BE FIELD CLIBRTED LINER 4-0m OUTPUT VILBLE FOR WIDE RNGE OF FLMMBLE GSES ND CO Performance Operation Resolution Warm up time to final zero Warm up time to specification Response time to target gas T90 MTBF Long Term Zero Drift Per Month Zero Repeatability During Operation Span (5%) Repeatability During Operation Continuous %FSD < 0 s < 30 minutes < 0 s > 5 years +/-0.05% +/-0.1% +/-0.1% Environmental: Operating Temperature Storage Temperature Relative humidity (non-condensing) -10 to +55 Deg C -0 to +60 Deg C 0 to100% Connections Outputs 3 Wire 4-0m Power Input Power Consumption 18 to 3V DC 90mW Physical Ingress Protection Housing Material Protection Concept Dimensions (mm) Mounting Thread Weight IP66 Stainless Steel 316 S16 Flameproof 50 Diameter x 80 Length M0 x 1.75 550 grams TEX pproved IECEX pproved Ex db IIC T6 Gb Ta = -0 to +40 C Ex db IIC T5 Gb Ta = -0 to +55 C IECEx EXV16.0003X Rating W ExVeritas 16TEX 0141X 585 II G D ExVeritas 16 TEX 0141X METHNE PROPNE BUTNE CETYLENE HEXNE ETHYLENE BENZENE IRCRFT FUEL JP-4 PETROL VPOURS HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345

SENSOR OPTIONS & CCESSORIES SHOWN WITH EEXd JUNCTION BOX COVER SECURING SCREW M0 x 1.5 18.5 5.0 145.0 16.0 40.0 18.0 Ø7.0 Ø110 EXTERNL ERTH 63.7 DETECTOR SHOWN Standard Junction Box P/N 504580 s bove Diagram Weather Protection ssembly Incorporating Test Gas pplicator P/N 401451 Collector Cone P/N 401061 Engineers Test Gas pplicator For Tocsin 10 P/N 401101 For Compatible Oliver Control Panels See: The Tocsin 601 Single Channel controller The Tocsin 700 One to 64 Channel Controller The Tocsin 90 ddressable System Controller The Tocsin 903 EEx Single Channel Controller The Tocsin 816 19 Rack System HSCO SOCO SK 6TS Fax: +44 (0) 161 484 345