VISION BASED AUTOMATIC FIRE PROTECTION SYSTEM USING SPRINKLER

Similar documents
Implementation of Auto Car Washing System Using Two Robotic Arms

MANUALLY OPERATED FIRE FIGHTING ALL- TERRAIN ROBOT WITH FIRE EXTINGUISHER USING ARDUINO MICRO CONTROLLER

Android Controlled Fire Fighting Robot

Multi - Purpose Fire Fighter Robot

Design and Development of Engineered Fire Suppression System

CLOUD CONNECTED SMART GAS LEAKAGE DETECTION AND SAFETY PRECAUTION SYSTEM

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d

Smoke and Fire Detection

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Team Rescue X: Autonomous Firefighting Robot

BURGLAR ALARM USING ARDUINO AND PIR SENSOR WITH SMS ALERT Burgoji Santhosh Kumar 1, S.Ramesh 2 1

Automobile Security System Based on Face Recognition Structure Using GSM Network

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

SAFETY PRE-ALARM MONITOR SYSTEM BASED ON GSM AND ARM

Fire Detection Using Image Processing

Equipment Based on NDT Technique and Used in Security and Safety Provision Systems

Development of a Sensing Module for Standing and Moving Human Body Using a Shutter and PIR Sensor

Microcontroller based design for Tele-sensing and extinguishing fire

AUTONOMOUS FLOOR CLEANING BOT

GSM Based Computer Lab Security System Using PIR Sensors

Smart Intrusion Detection

A Survey on implementation of Fire detection System Based on ZigBee Wi-Fi Networks

Characteristics of different sensors used for Distance Measurement

Wifi Enabled Wireless Operated Fire Extinguisher Vehicle With Water Jet Spray

"Three Preventions" System Design Based On Single-Chip Microcomputer (SCM) Control Jiaxiong Wen

Wireless Local Area Network Based Fire Monitoring Robot Design Rong Gao 1, a, Qisheng Wu 2,b and Lan Bai 3,c

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

IOT ENABLED FOREST FIRE DETECTION AND ONLINE MONITORING SYSTEM

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Development of cleaning system installed in horizontal moving system for maintenance of high-rise building

Remote Environment Monitoring & Detection Tribot

Design of Climatic Control Fan

Final Report FIREMAN

Firefighting Robot. I. Introduction

International Journal of Scientific & Engineering Research, Volume 7, Issue 7, July ISSN

Impact of Tunnel Ventilation on Tunnel Fixed Fire Suppression System

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

DESIGN OF A CONTROL SYSTEM TO OPTIMIZE POWER CONSUMPTION IN AIR CONDITIONERS TO SATISFY HUMAN THERMAL COMFORT

ENACTMENT OF SCADA SYSTEM FOR JUDICIOUS DWELLING

International Journal of Advanced in Management, Technology and Engineering Sciences

Homework 8: Patent Liability Analysis Due: Thursday, March 24, at Classtime

A System for 360 Video Surveillance with Multiple Remote Control Access

REMOTE CONTROL AND MONITORING OF LANDMINES DETECTION ROBOTIC SYSTEM

Cost Effective Home Automation System

Implementation of Artificial Neural Fuzzy Inference System in a Real Time Fire Detection Mechanism

Pi Cam Based Smoke/Fire Alerting System

Advanced Driver Assistance System with Accident Detection

Exterior Fire Protection for High-Rise Buildings

Gas Detection Instrument Based on Wireless Sensor Networks

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW

Intelligent monitoring system for automobiles

IR Tracking NERF Sentry Gun. Ryan Alvaro, Emily Dixon, Lauren Klindworth Team 13

MICROCONTROLLER BASED HOME AUTOMATION SYSTEMS

FlameRanger. Revolutionary Firefighting Robot.

Petrol Bunk Automation with Prepaid Card using GSM Identification

V.ARCHITECTURE IV.IMPLEMENTATION. Battery. Fig.1.Block diagram

Design of Fire Suppression in Train Using GPS & IoT

A Novel Approach to Garbage Management Using Internet of Things for Smart Cities

Virtual Boundary System Using Passive Infrared Sensor

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Accident Prevention System for Boats in Maritime

Fire Detection System using Matlab

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

ROBOT: HOME AUTOMATION SYSTEM USING RASPBERRY PI AND SENSORS

FIRE SAFETY PRACTICES AND PROCEDURES

Design and Development of General Purpose Alarm Generator for Automated System

Chapter 2 Background. 2.1 VID Technology

AN IOT BASED FOREST FIRE DETECTION AND PREVENTION SYSTEM USING RASPBERRY PI 3

AUTOMATIC CABLE SPOOLING for A ROBOTIC VACUUM CLEANER

AUTOMATIC FIRE EXTINGUISHING SYSTEM for TUNNEL PROTECTION with SPREAD REMOTE CONTROLLED MONITORS (TUDEM-LEGIO)

Android Operated Intelligent Fire Extinguishing Vehicle

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

Design and Development of Gas Leakage Monitoring System

Wireless Sensor Network Based Bank Monitoring System Using LabVIEW

REVIEW ON WATER MIST FIRE SUPPRESSION SYSTEM

Volume Measuring System Using Arduino for Automatic Liquid Filling Machine

Autonomous robots in agricultural field trials

An experimental study of the impact of tunnel suppression on tunnel ventilation

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

Fire Fighting Robot Controlled Using Android Application

IMAGE PROCESSING BASED FIRE DETECTION ANDALERT SYSTEM

VOICE BASED PROJECTS

Early Fire Detection and Automatic Extinguishing in Waste-to-Energy Power Plants and Waste Treatment Plants

An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b

SMUGGLING PREVENTION SYSTEM FOR TREES IN FOREST USING IOT

II. METHODS AND MATERIALS

Raspberry PI Based Wireless RF Controlled Fire Fighting with High Pressure Air Blower

Smart Personal Security Alert Walking Stick For Visually Challenged People

Water Mist Fire Suppression System protecting the electrically powered shredder and the ballistic separator at an MRF in Devon

Fire protection for buildings

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

GORAKSHAK : AN AUTOMATED FARM VIA IOT

Implementation of Weather Monitoring System

FIGHTING FIRE as easy as blowing out a match

Consultant Specification AGILE Wireless Fire Detection System

CCTV, HOW DOES IT WORK?

Transcription:

VISION BASED AUTOMATIC FIRE PROTECTION SYSTEM USING SPRINKLER M. Nandhini, R.Ranjani,R.Srividhya Assistant Professor, Department of Mechatronics Engineering, SRM University, Chennai, Tamilnadu ABSTRACT This paper deals with building an application model of an automated fire protection system in an indoor environment. This model is a highly localized and targeted Fire Extinguishing system. The system consists of an arm which ends with the turret mounted with dispenser. An Infra-Red camera is used to detect the fire using the rays received and the processor inside the camera converts them into an image using various colours for different temperatures. The acquired image is then processed and the sources of heat are isolated. The position of the source of fire is mapped from the camera coordinates to the real world coordinates using a microcontroller and the turret is aimed at the fire by a targeting control system which triggers the servomotor used to move the turret. When the turret is targeted towards the center of the fire source, water is released using the sprinkler controlled by a solenoid valve. Thus the sources of fire in the field of view of the camera are suppressed. Keywords: Indoor environment, Fire Extinguishing System, Sprinkler, Solenoid Valve INTRODUCTION Fire is useful to man only when there is a good control of it. Therefore, it is important to stay away when there is an emergency fire. To prevent or minimize the risks of fire there should be sufficient precautionary measures, such as, immediate warning and notifying the threat. Fire sprinklers are most effective during the fire's initial flame growth stage. A properly selected sprinkler will detect the fire's heat, initiate alarm and begin suppression within moments after flames appear. In most instances sprinklers will control fire advancement within a few minutes of their activation. This will in turn result in significantly less damage than otherwise would happen without sprinklers. Fire sprinklers remain the most reliable and cost-effective measure to reduce or prevent loss of lives and property. In a typical wet system, each fire sprinkler activates independently limiting the number of operating sprinklers to only those near the fire. A properly designed sprinkler system can contain or extinguish a fire before the fire department arrives resulting in less overall damage from smoke and fire. Besides their life property saving benefits, fire sprinkler design and installations can be an economic benefit. Compliance is intended to prevent injury, life loss and property damage. The standard requires at least 10 minutes of sprinkler water on the fire in its initial stage of development. 45

That controls the fire early, giving residents the time to escape safely and providing sufficient time to the fire department time to arrive. A typical home fire will be controlled and may even be extinguished by the time the fire department arrives. Fires are also fast, they can go from a tiny flame to total destruction in as little as two to three minutes. Fire sprinklers can suppress and often extinguish a fire before the fire department arrives, giving your family to escape. Including fire sprinklers in new home is a great idea that can save family members lives. Surrounding rooms are protected from fire, heat and smoke damage. Fire sprinkler systems are typically designed to release water droplets of a carefully controlled size large enough to get to the core of a fire before they evaporate. The water flow is strong enough to drop the core temperature of the fire below sustainable levels, effectively dousing it before it has a chance to spread much beyond the point of origin. Fire sprinkler systems are designed to cover a certain range of space as well. The space is meant to be large enough to assure that the water distribution is large enough to effectively control a fire large enough to set off the system using only one sprinkler head. Typically, the water flow will continue until the fire sprinkler system is shut off by the fire brigade a precaution taken to make sure the fire is entirely controlled. The main objective of the project has to suppress the fire produced surprisingly in an indoor environment with a minimum number of sprinklers. The location of the hot spot has to be found from the acquired IR image. The turret in the sprinkler points towards the fire and operate the solenoid valve to open up the sprinkler. Thus the water flowing through the solenoid forces the sprinkler to extinguish the fire. This has been aimed at the pin-pointed area of fire either extinguishing it or keeping it under the control, unlike conventional fire sprinklers delivering water over the entire area and not at localized fire. IMAGE PROCESSING Image processing is a method to convert an image into digital form and perform some operations on it, in order to get an enhanced image or to extract some useful information from it. It is a type of signal dispensation in which input is image, like video frame or photograph and output may be image or characteristics associated with that image. Usually Image Processing system includes treating images as two dimensional signals while applying already set signal processing methods to them. An Infra-red camera is used to detect the fire and gives the image to be processed. Image Processing is done using MATLAB software. The area of fire to be maximum is found by processing the image by the separation of the RGB values. The larger area of fire is only suppressed by fire since it causes too many damages to the environment. 46

Fig 1.Separation of Fire The detection and separation of fire is shown in fig 1. The source of fire is found based on the centroid in the separated area and the water is suppressed by the sprinkler. DESIGN OF THE HARDWARE 1.1 Description The hardware system of the sprinkler consists of pneumatically operated solenoid valve in which one end is connected to the reservoir system and the other end is connected to the stepper motor. Pendant type sprinkler system is used. An Infra-red camera is used for the acquisition of the image. It must be placed in order to get the maximum field of view. A circular disc for mounting this entire setup is used. The reservoir system and the discharge pump are used. The arduino microcontroller has been chosen for the controller system. 1.2 Proposed Design The design of the entire system is done using the Pro-E software which was shown in fig 2. A circular disc with support on either side is placed on the top of the experimental box in which the controllers are placed. On the top of the disc, a rod is inserted in such a way that it is connected to the stepper motor for the disc to rotate in 360 degrees. Below the disc sprinkler system and the servo motor is connected through the rod. A shaft is inserted to the servo motor which is held by the bearing in which the sprinkler system is placed. The turret of the sprinkler is rotated by 180 degrees. Solenoid valve is placed above the rotating disc. One end of the valve is connected to the displacement pump and the other end is connected to the sprinkler system. 47

Fig 2.PRO-E model of the system 1.3 Principle of Working In the case of no detection, the system enters scan mode. In this mode the turret slowly rotates its base 180 back and forth, quickly swinging the turret 180 in order to monitor the surrounding area. The speed of each actuator was adjusted considering the camera aperture and detection speed, the entire semi-sphere in range can be imaged in close to half a minute. When one or more points are detected, the control automatically switches to targeting mode optionally by turning the turret towards the hotspot. The water nozzle and the camera are aligned in such a fashion the water hits the region central to the image. When in targeting mode the points detected by the image processor are ordered by distance to the center of the image, then the two actuators are used to align the nearest point with the center, placing the source of detection right under the effect zone, within the reach of the water nozzle. Once the point is within the effect zone, a solenoid valve is activated releasing the fire extinguishing agent. The flow of the system is as shown in fig 3. 48

1.4 Block Diagram Fig 3.A Simplified Flow Diagram The block diagram of the system as shown in figure 4 consists of two parts, electronic circuits and pneumatic circuits. Electronic circuits consist of the controllers, IR camera and the sprinkler. The entire system is placed in the ceiling.ir camera keeps on monitoring the fire, captures the image and sends to the Pneumatic circuits consist of the reservoir, diaphragm pump for pumping the water and the solenoid valve for triggering is placed on the floor. 49

RESULTS AND DISCUSSIONS 1.5 Experimental Setup Fig 4.Block Diagram of the System The controller system where the program is loaded is shown in fig 5a. The whole setup is balanced with the help of this controller box. Below this the sprinkler setup placed is shown in fig 5b. A sprinkler is connected to the frame of the aluminium shaft. Fig 5.a)Controller Setup b)sprinkler Setup 50

1.6 Calculation of Sprinklers The pressure at the orifice of the sprinkler depends on the header of the source. In this project the source is the over tank whose vertical height is approximately measured as 12ft(144 inches). 27.71inchesH 2 o=1psi 144inchesH 2 o =5.20psi 1kg/cm 2 =14.22psi Therefore 5.20psi=0.36kg/cm 2 0.5bar According to NFPA, If the pipe used is of half inch diameter, For a water pressure of 0.5bar and density of 5 litres/min per ft 2. One sprinkler is required for every 180ft 2 The area taken for this project has dimensions of 12ft x 15ft (180ft 2 ).Hence one sprinkler is required for this project. 1.7 Limitations Sprinkler system cannot be used in an open environment since the radiation of the sun may disturb the reception of IR rays from the fire. Requirement of water has to be clean and free from sand. The storage of flammable or combustible liquids is generally not allowed. Flue spaces between storage pallet loads within storage racks must be maintained. Electrical fires cannot be extinguished using the sprinkler system since it is water controllable. CONCLUSION In this project,employed control systems and actuators as well as digital imaging to propose a new solution to an old problem. A prototype was assembled (presented in figure 2), demonstrating successfully the suitability of the proposed alternative to replace conventional fire sprinklers. Upon activation the water damage in minimized in opposition to the extensive water damage caused to electronic equipment, furniture, books and paperwork by conventional sprinklers. The numbers of sprinklers were reduced to a particular area. The tilting of the sprinkler can cover about a larger area which provides an additional advantage. The proposed model is expected to respond quickly in controlling fire thus having an outright advantage over other systems which are in use. 51

REFERENCES [1] Agostino De Santis, Bruno Siciliano, and Luigi Villani (2005), Fuzzy Trajectory Planning and Redundancy Resolution for a Fire Fighting Robot Operating in Tunnels Proceedings of the IEEE International Conference on Robotics and Automation. [2] Daniel J. Pack, Robert Avanzato, David J. Ahlgre and Igor M. Verner (2004), Fire-Fighting Mobile Robotics and Interdisciplinary Design-Comparative Perspectives IEEE Transaction on Education, Vol. 47, No. 3. [3] Hongke Xu, Hao Chen, Chao CAI, Xunzhao Guo, Jianwu Fang and Zhu Sun (2011), Design and Implementation of Mobile Robot Remote Fire Alarm System International Conference on Intelligence Science and Information Engineering. [4] Jean-Luc Wybo (1998), FMIS: A Decision Support System for Forest Fire Prevention and Fighting IEEE Transaction on Engineering Management Vol. 45, No. 2. [5] KuoL. Su (2006), Automatic Fire Detection System Using Adaptive Fusion Algorithm for Fire Fighting Robot IEEE International Conference on Systems. [6] Lasith Fernando, Hiran Ekanayake and Nalin Ranasinghe (2004), Automated Fire Controlling for Structured Zones by Autonomous Robots, IEEE Conference on systems. [7] Martinson. E, Lawson. W, Blisard. S, Harrison.A and Trafton. G (2012), Fighting Fires with Human Robot Teams IEEE/RSJ International Conference on Intelligent Robots and System. [8] Rogério Neves, Francisco Zampirolli and Thiago Okazaki, A Smarter Fire Sprinkler Proceedings of the 5th International Symposium on Communications, Control and Signal Processing, May 2012. [9] Swetha Sampath.B (2011), Automatic Fire Extinguisher Robot International Conference on Ubiquitous Robots and Ambient Intelligence. [10] Ting L. Chien, Jr H. Guo, Kuo L. Su and Sheng V. Shiau (2007), Develop a Multiple Interface Based Fire Fighting Robot Proceedings of International Conference on Mechatronics. [11] Yen Kheng Tan and Sanjib Kumar Pand(2011), Self-Autonomous Wireless Sensor Nodes With Wind Energy Harvesting for Remote Sensing of Wind-Driven Wildfire Spread IEEE Transaction on Instrumentation and Measurement, Vol. 60, No. 4. [12] Young-Duk Kim, Jeon-Ho Kang and Duk-Han Sun (2007), Design and Implementation of User Friendly Remote Controllers for Rescue Robots in Fire Sites SICE Annual Conference. 52