LS Condensate Removal Pump Installation, Operation and Service Instructions

Similar documents
LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

CHUGGER PUMP Chugger Max Models

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Instruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica.

INSTALLATION INSTRUCTIONS

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

AGA TOTAL CONTROL. Model No. - TC3

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

FES - Series Portable Electric Heaters

INSTALLATION GUIDE NZ AU C

Dehumidifier. Instruction Manual. Model DH-320/A

Installation Instructions

Two Tier Illumifalls Patio Pond

Installation Instructions

Instruction Sheet. ECM High-Efficiency Circulator. SUPERSEDES: January 24, 2016 EFFECTIVE: March 29, 2016

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

CH750, CH751 & CH951 CHILLERS

SUBMERSIBLE WATER PUMPS

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Dishwasher Installation Manual

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE NZ AU

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

EN Z Subject to change due to technical improvements! Operating instructions

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

GDDEM10 DEHUMIDIFIER

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

! WARNING. Before using product, read and understand instructions.

DOUBLE DISHDRAWER TM DISHWASHER

OPERATION & MAINTENANCE INSTRUCTIONS

Vitronic 9 / 18 / 36. Operating instructions Notice d emploi Instrucciones de uso

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

DIRTY WATER SUBMERSIBLE PUMP

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

CH250 AND CH251 CHILLERS

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

DIRTY WATER SUBMERSIBLE PUMP KIT

PORTABLE DEHUMIDIFIER

SINGLE DISHDRAWER TM DISHWASHER

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

VISUAL DISPLAY DISPENSER OWNERS MANUAL

Ice Maker. Use and Care Instructions. with water dispenser. Durable, high-quality stainless steel finish

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

Removing shipping locks

Installation, Operation & Maintenance Manual. AromaSteam. mr.steam. l Feel Good Inc.

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

K Series (Model A) Fan Forced Wall Heaters

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Viking Installation Guide

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

PORTABLE ICE MAKER 26.5 lb RHIM-15001~2

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

USER MANUAL ICE MAKER

Operating instructions

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

IMPORTANT INSTRUCTIONS READ & SAVE

Installation, Operation & Maintenance Manual. AromaSteam. mr.steam. l Feel Good Inc.

WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE PROBLEMS CORRECTLY BEFORE SERVICING THE UNIT.

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Ice Maker. De Glaçons. Portátil PIM9W. Use & Care Guide Guide d utilisation et d entretien Manual de uso y cuidado. Portable.

hp Dust Collector With Vacuum Attachment

Air Pump Up to 800 gallons

INSTALLATION INSTRUCTIONS

Installation Instructions for. OmniFount

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

2 IN 1 SUBMERSIBLE PUMP

Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

AIR CONDITIONING UNIT

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

FLCH4R Garage and Utility Electric Heater

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Submersible Garden Pump USER'S MANUAL

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Lumination TM Volumetric Retrofit Kit

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Moisture inside the drum is due to final testing.

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

STEAM WALLPAPER STRIPPER MODEL HTW5

3-way switching valve

Transcription:

Bell & Gossett Instruction Manual 6-71-075-115 LS Condensate Removal Pump Installation, Operation and Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. WARNING: This safety alert symbol will be used in this manual and on the pump Safety Instruction decal to draw attention to safety related instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD. Your Condensate Removal Pump should have the warning/caution label and non submersible warning label displayed in Fig. 1 on the pump conduit box. If this warning and caution label is missing or illegible, contact your local B&G Representative for a replacement. Fig.1 The installation and operating instructions in this manual must be followed when installing and operating the LS condensate pump. Please read them carefully. We recommend that you keep it close to the pump. Particular attention must be paid to notes marked as follows: WARNING: If this instruction is not followed, personal safety risks could ensue. If this instruction is not followed, the device may not function properly and could be damaged. Other relevant regulations must also be observed, e.g. accident prevention regulations or internal operating and safety instructions of the system manufacturer. Failure to follow these instructions can result in the loss of all entitlement to claim damages. General Description The LS Condensate Pump is an automatic pump for pumping condensation water from condensing boilers, air conditioning systems, coolers, dehumidifiers, or other similar systems. The corresponding regulations on draining to the sewage system must be observed. If necessary, a neutralizing unit must be installed upstream from the condensate pump.

CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very short period. Applications The LS is designed for condensate from: Gas or oil condensing boiler (maximum heating capacity 682,000 BTU/h) with ph of 2.7 or higher Air conditioning systems, cooling, and refrigeration systems. Air dehumidifiers and evaporators Specifications Supply voltage 100-240 V Frequency 50 / 60 Hz P1 power supply capacity 20 Watt Current consumption 0.2 0.1 A Degree of protection IP 44 / Class F Max. delivery head 45 kpa Max. pump capacity 450 l/h Noise level (L w ) 46 db(a) Acid resistance ph 2 or higher Max. media temperature + 140 F (60 C) Min. ambient temperature Not freezing 50 F (10 C) Floating contact Break contact, switching capacity 250 VA Tank volume 0.7 l (usable volume 0.5 l) Packaging dimensions 8.5 x 8.5 x 7.1 (215x215x180 mm) Packaging weight 3.52 lbs (1.6 kg) Subject to technical changes due to product modifications Fig.2 Dimensional Drawings Fig.3 4.65 (118) 5.83 (148) 3.54 (90) 6.61 (168)

Included Items Your LS Condensate Pump should include the following items. See Fig.4 below. (a) (b) (c) (d) a. LS Condensate Pump unit b. Mounting bracket (designed for rear wall or left side wall mounting) c. Pressure hose connection kit d. Pressure hose (19ft.) Optional items that may be needed for pump installation: Hose clamps Safety Requirements Prior to starting the installation process, please observe and understand the following safety requirements. Failure to understand these instructions could result in personal injury, death, and/or property damage. Mechanical Safety WARNING: - Excessive System Pressure Hazard - The maximum working pressure of the pump is listed on the nameplate - Do Not Exceed This Pressure. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Excessive Pressure Hazard Volumetric Expansion - The heating of water and other fluids causes volumetric expansion. The associated forces may cause failure of system components and the release of high temperature fluids. This can be prevented by installing property sized and located compression tanks and pressure relief valves. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Thermal Safety WARNING: - Extreme Temperature Hazard - If the pump, motor or piping are operating at extremely high or low temperature, guarding or insulation is required. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Electrical Safety WARNING: - Electrical Shock Hazard - Electrical connections are to be made by a qualified electrician in accordance with all applicable codes, ordinances and good practices. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Electrical Grounding Hazard - Adequate electrical grounding is required for the safe operation of B&G Pumps. Connect the ground wire to the ground terminal in the wiring compartment. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Risk of Electric Shock - Do not install this pump in swimming pool or marine areas. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Installation The LS Condensate Pump must be installed in dry rooms (frost proof and where the air temperature does not exceed 140 F (60 C) using the installation bracket provided. It is mounted to the wall below the condensate supply outlet. Ensure that the pump is mounted horizontally. If floor-mounted, ensure that it is in a stable position We recommend that you also secure it to the nearest wall. WARNING: The unit may not be installed in areas where there is a danger of explosion! After a suitable location for installation has been determined. Follow these steps and pre-cautions continued on the next page:

1. Condensate supply hose must be routed with a downward slope to the LS Condensate Pump. (See Fig.5) 2. Ensure condensate supply hose is inserted deep enough into the tank inlet so that it cannot slip out unintentionally. A second inlet opening is available for additional hose connections. 3. For installation of the condensate drainage hose ensure hose is inserted as far as possible onto the non-return valve. Tip: We recommend that you also secure the hoses using hose clamps. 4. After securing hose on non-return valve, lock non- return valve by rotating valve one quarter turn clockwise. Electrical Connection The LS has a 6.5 ft (2m) long mains cable with a shock-proof plug. If the cable is not long enough, we recommend that you use an extension lead or connect a distribution box. The mains cable is permanently connected to the pump and cannot be removed and replaced with a longer mains cable. The electrical connection used must comply with the applicable standards. In particular, it must be properly earthed and fused. WARNING: All electrical work done may only be performed by qualified electrical professionals. Alarm connection The LS Condensate Pump is equipped with an alarm connection (switching with a 15 sec delay). This allows the condensing or air conditioning system to be switched off to prevent more condensate being fed and the tank overflowing. If the alarm connection is to be used, the 6.5 ft (2m) alarm connection cable must be connected as shown in the illustration. If the cable is not long enough, we recommend that you connect a distribution box. The alarm cable is permanently connected to the pump and cannot be removed. If the alarm connection is not used, the alarm cable can be cut off directly at the pump. In order to prevent moisture penetrating into the pump electronics, replace the original rubber cap with the hole with the closed rubber cap provided. Functional Testing After installing the condensate pump, we recommend that you test it to ensure that it functions correctly. To test the function, pour water (approx. 0.4 l) into the tank via the secondary inlet opening if possible, until the activation level is reached and the pump starts. If air in the pump causes the integrated dry-run protection to actuate (pump deactivates, green and red operating lamp flash), add a further 0.2 l of water and wait for one minute. The pump restarts automatically after one minute. The LS condensate pump is now functional. Routine Maintenance and Disassembly of LS Condensate Unit Fig.5 Fig.6 4 L N PE max. 4m WARNING: The LS Condensate Pump must be disconnected from the mains power supply before maintenance or disassembly! The LS pump does not require special maintenance. However, we recommend that you remove encrustation and rinse with clear water regularly in accordance with the occurrence of soiling. When you press in the clip, the LS can be removed by pulling it upwards away from the mounting bracket (see exploded view illustration). Disassembly of the condensate pump: Remove the pressure hose and non-return valve from the pump housing by turning them one quarter turn counter-clockwise. Pull the condensate supply hose carefully out of the tank. WARNING: Condensate from condensing systems is aggressive. Avoid contact with residual condensate in the tank, in the condensate supply hose or in the pressure hose!

Operating Lights and Fault Overview Ready for operation = Steady green light Fault = Red light Pump running = Flashing green light The alarm output is opened when a fault occurs. WARNING: Work on electrical parts of the LS Condensate Pump may only be performed by qualified electrical professionals. Operating Green Lamp Red Cause Solution Off Off Mains plug not plugged in Insert plug Power failure Check mains and fuse Flashing Flashing Dry-run (Poss. air in tank) Pump restarts automatically after one minute On Flashing Pump blocked Visual inspection of the pump inlet in the tank and removal or rinsing of dirt or foreign bodies On On Level exceeds alarm level Pressure hose / non-return valve blocked (clean or remove kink if applicable) Off Flashing Pump blocked and alarm level Visual inspection of the pump inlet alarm exceeded level exceeded in the tank and removal or rinsing of dirt or foreign bodies; Warranty WARNING: The LS Condensate Pump must be disconnected from the mains power supply before maintenance or disassembly! Malfunctioning condensate pumps can be returned to the manufacturer s address. The manufacturer will refuse to accept packages with unpaid shipping or invoices for repair. The manufacturer guarantees the LS condensate pump for two years subject to correct installation and proper use of the device. Product Disposal This product and parts thereof must be disposed of in an environmentally friendly way. Corresponding local regulations must be observed. Product Breakdown 1. Condensate inlet (.95 24mm) 2. Additional inlet opening (6.95 24mm) 3. Magnet float 4. Mounting bracket (for rear wall or left side wall) 5. Clip 6. Main cable (6.5ft 2m) with shock-proof plug 7. Alarm connection cable (floating, 6.5ft 2m) 8. Non-contact electronic fill level detection with echo sensors 9. Connection for pressure hose (.55 x.08, 19ft) 10. Non-return valve with bayonet connection 11. Opening for non-return valve 12. Pressure nozzle 13. Tank (0.7l; usable volume 0.5l) 14. Permanent magnetic rotor/impeller 15. Pump sump 16. Operating LEDs 17. Stator of the high-efficiency spherical motor pump

WARNING: a. For indoor use only and Enclosure type 2 b. Caution: this pump has been evaluated for use with water only or equipvalent c. Non-submersible pump d. To reduce risk of electric shock, pull the plug before servicing this pump e. To reduce risk of electric shock, install with motor and all electrical components above the top grade level of the sump. This pump is not submersible. f. Risk Of Electric Shock This Pump Has Not Been Investigated For Use In Swimming Pool Or Marine Areas g. To reduce risk of electric shock, connect only to a properly grounded, grounding-type receptacle WARNING: a.employer UNIQUEMENT À L INTÉRIEUR and BOÎTIER DE TYPE 2 b. Attention: cette pompe a été évaluée pour une utilisation avec de l eau c. Pompe non-submersible d. Pour réduire le risque de choc électrique, débranchez la fiche avant de réparer cette pompe e. Pour réduire le risque de choc électrique, placer le moteur et tous les composants électriques au-dessus du plus haut niveau de qualité du puisard. Cette pompe n est pas submersible. f. Risque de choc électrique - Cette pompe n a pas été étudiée pour une utilisation en piscine ou en milieu marin g. Pour réduire le risque de choc électrique, connecter uniquement à une prise correctement mise à la terre prise de type WARNING: Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. Instruction shall include the following cautionary: Caution: this pump has been evaluated for use with water only and WARNING: Risk of electric shock This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Copyright 2010 ITT Corporation, Printed in Hungary 11-10 THE ITT ENGINEERED BLOCKS SYMBOL AND ENGINEERED FOR LIFE ARE REGISTERED TRADEMARKS OF ITT MANUFACTURING ENTERPRISES, INC. ITT 8200 N. Austin Ave. Morton Grove, IL 60053 Tel: (847) 966-3700 Fax: (847) 966-9052 www.bellgossett.com