NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE
BALANCED VENTILATION WITH HEAT RECOVERY Fresh air intake HRU ECO 3 RF Exhaust bathroom Exhaust kitchen Exhaust ilet Designs for the Future With the Government actively encouraging energy saving and a target for all new homes be carbon zero by 2016, the HRU ECO 3 RF has been designed future proof. The Code for Sustainable Homes which came in force in March 2007, details six levels of CO 2 emission improvement over 2006 Building Regulations requirements. To achieve the three highest levels of reduction of carbon emissions, the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the only appropriate method. In addition, it must be demonstrated that the ventilation system itself must be energy efficient. The HRU ECO 3 RF has been third party SAP Q 1 tested by the Building Research Establishment (BRE) the apropriate SAP Appendix Q test methodology and is Appendix Q eligible. 1 The Governments Standard Assessment Procedure (SAP) is a method assessing the energy performance of dwellings and SAP Appendix Q provides an allowance for the benefits of energy-saving appliances; products may be independently assessed and the results uploaded the SAP website.
Code 9800 - HRU ECO 3 RF Manufactured lightweight material. Patented airtight clamped construction. Complete with Wall Mounting Bracket. Complete with a length of sound insulating fl exible duct. 95% efficient (NEN 5128) Synthetic Counter Flow Heat Exchanger. Aumatic 100% Suer Bypass. Aumatic Frost protection device. 2 x Backward curved centrifugal fans with energy efficient DC mors. G3 Filters on both the Fresh Air Inlet and the Extract. All parts guaranteed against defect for 2 years. Complete with 2 x Wireless Control Switches. 3 speed settings + boost speed timer function (10 30 minutes). Energy Saving: pre-warmed fresh air lowers the heating requirement. Comfort: slow air movement eliminates draughts. Health: constant fresh air supply. Noisy sites: balanced system with no need for trickle ventilars. Exhaust house Fresh air bedroom The 2006 Edition of the U.K Building Regulations Approved Document F1:Means of Ventilation (applicable in England and Wales) details 4 clearly defined systems of ventilation dwellings. System 4 - Continuous mechanical extract with heat recovery (MVHR) is complied with by the new HRU ECO 3 RF ultra-high efficiency whole house heat recovery ventilation system. The system provides quiet, uninterrupted extract ventilation the dwelling, removing warm stale air via all of the wet rooms, creating a permanent air path through the property the dry habitable rooms. Air, drawn in the property by the fan is routed through an integral high-efficiency synthetic heat exchanger where warmth the extracted air is transferred the incoming fresh air before it is supplied the habitable rooms. In employing this type of system, there is no need install background ventilars in the dwelling - an ideal solution noisy sites. To counter increased pollutants caused by cooking or bathing activities, a wireless boost facility allows the fan s balanced extract and supply rates be increased anywhere in the property where an RF Switch is positioned. The HRU ECO 3 RF unit is equipped with an integrated fully aumated suer bypass valve that ensures that, if required, fresh air drawn in the unit fl ows directly in the air supply system instead of through the heat exchanger; in this instance there is no heat transfer between the warmer discharge air and the cooler supply air. This is a definite advantage in the suer, when air is often cooler than air indoors. An integrated fully aumatic frost protection valve ensures that the unit does not freeze during the colder months. Due the unique clamping construction in combination with the plastic/synthetic elements, the weight of the heat recovery unit HRU ECO 3 RF fan is only 25 kg. Fresh air living room Designed and Manufactured by Itho bv and supplied exclusively in the U.K. by Vortice Limited. All exhaust and supply air connections have an internal diameter of 150 and external 180. The connections can be used attach Vortice modular rigid ducting and insulated fl exible aluminium ducts and accessories. Each connection is provided with an illustration that shows the direction and source of the air. Standard NEN 5128 defines the efficiency of heat recovery units for dwellings. As a result of the efficiency determined a certificate of equivalence for the HRU ECO 3 RF fan has been issued. An efficiency of 95% can be used in the EPC calculation. In addition, the product has successfully passed the test requirements of BS EN308:1997: Heat exchangers. Test procedures for establishing the performance of air air and fl ue gases heat recovery devices.
No leakage fresh air exhaust air 1 Heat exchanger tight fitting in the EPP housing. 2 Tape on sides for extra sealing. 3 Bayonet fitting seals the cover the heat exchanger. 4 Patented Clamp Device guarantees air tightness. 1 2 3 4 Labelled duct connection 1 Supply Air House. 2 Fresh Air Outside. 3 Exhaust Air House. 4 Exhaust Air Outside. 1 2 3 4 Ultra quiet operation 1 Quiet fan. 2 Vibrations damper. 3 Absorbtion foam. 4 Air fl ow speed as low as possible. Capacity adjustable. 1 2 3 4
Wireless 3 speed control with timer - RF-Set Timer push 1 x 10 minutes. Timer push 2 x 20 minutes. Timer push 3 x 30 minutes. Normal Operation Mode Frost Protection Mode Suer Bypass Mode
DIMENSIONS () AND CERTIFIED PERFORMANCE EXT. Ø F INT. Ø E D A C B Model Code A Height over Body B Width C Height (over connections) Depth Duct connection int. Ø E ext. Ø F Discharge condensate ext. Protection Filter Grade Weight kg HRU ECO 3 RF 9800 789 730 848 473 150 180 40 IP31 G3 24,1 Mode Capacity Pressure Power Current Voltage Power Facr Cos Phi Thermic performance m 3 /h Pa W A V * % Mode 1 Minimum mode 50 10 8 0,05 230 0,07 98 Mode 1 Low mode 75 20 12 0,1 230 0,55 98 Mode 2 Medium mode 150 40 29 0,24 230 0,53 96,2 Mode 2 Medium mode 150 80 38 0,31 230 0,53 96,2 Mode 3 High mode 225 100 74 0,59 230 0,59 94 Mode 3 High mode 225 150 88 0,69 230 0,56 94 Mode 3 High mode 275 100 106 0,83 230 0,56 93 Mode 3 High mode 275 150 126 0,99 230 0,56 93 Mode 3 Maximum mode 325 100 156 1,22 230 0,56 92 Mode 3 Maximum mode 325 150 176 1,36 230 0,56 92 * Values entered in the EPC calculation NEN 5128
BUILDING REGULATIONS DOCUMENT F1 2006 Continuous mechanical supply & extract ventilation with heat recovery A continuous balanced mechanical central supply and extract system be positioned in loft or cupboard space. An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost. In employing this type of system, there is no need install background ventilars in the dwelling. Continuous supply and extract 1 Determine the whole building ventilation rate Table 1.1B Allow for infiltration by subtracting - for multi srey dwellings: 0.04 x gross internal volume of dwelling heated space (m 3 ). - for single srey dwellings: 0.06 x gross internal volume of dwelling heated space (m 3 ). 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate Table 1.1A. 3 The required air flow rates are as follows: Maximum Extract Rate (boost) is the greater step of 1 and 2 above. The Minimum individual room extract rates should be at least those given in Table 1.1A for minimum high rate Minimum air supply rate should be at least the whole building ventilation rate in 1 above. 4 No Background ventilars are required with System 4. Table 1.1 A Room Minimum intermittent extract rate Continuous rate Minimum high rate Minimum low rate Kitchen 30 l/s (adjacent hob); or 60 l/s elsewhere 13 l/s Utility room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accomodation 6 l/s 6 l/s Total extract rate must be at least the whole building ventilation rate in Table 1.1B Table 1.1 B Number of bedrooms in dwelling 1 2 3 4 5 Whole building ventilation rate (l/s) 13 17 21 25 29 Minimum value in any dwelling of 0,3 l/s per m 2 fl oor area In addition, the minimum ventilation rate should not be less than 0,3 l/s per m 2 internal fl oor area (this includes each fl oor, e.g. for a two-srey building, add the ground and fi rst fl oor areas). This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as thedefault value. If a greater level of occupance is expected, then add 4 l/s per occupant.
ACCESSORIES CODE DESCRIPTION 22020 Fixed Grille 125/150 Diameter (Grey) 8224 Fixed Grille 150 Diameter (White) EXTERNAL TERMINALS AND 8227 Fixed Grille 150 Diameter (Brown) ASSOCIATED COMPONENTS 8230 Fixed Grille 150 Diameter (Beige) 8233 Fixed Grille 150 Diameter (Terracotta) 9104 Semi-rigid Wall Liner 150 Diameter 8136 Spigot Plate 150 Diameter 8340 Insulated Flexible Ducting 100 Diameter X 4 m Length 8331 Insulated Flexible Ducting 100 Diameter X 10 m Length INSULATED FLEXIBLE 8342 Insulated Flexible Ducting 125 Diameter X 4 m Length ALUMINIUM DUCTING 8333 Insulated Flexible Ducting 125 Diameter X 10 m Length 8341 Insulated Flexible Ducting 150 Diameter X 4 m Length 8332 Insulated Flexible Ducting 150 Diameter X 10 m Length 8681 Y-piece 100 Diameter 8682 Y-piece 125 Diameter 8683 Y-piece 150 Diameter 8174 Duct Joining Piece 100 Diameter 8415 Duct Joining Piece 125 Diameter 8672 Duct Joining Piece 150 Diameter 8063 Reducer 125-100 Diameter FLEXIBLE DUCTING COMPONENTS 9239 Reducer 150-100 Diameter 9238 Reducer 150-125 Diameter 9807 Reducer 180-150 Diameter 8039 Worm Drive Clip 100 Diameter 8040 Worm Drive Clip 125 Diameter 8041 Worm Drive Clip 150 Diameter 8042 Worm Drive Clip 200 Diameter 8020 Pvc Sealing Tape 8410 Flat Channel 1,0 m Length 8416 Flat Channel 1,5 m Length 8406 Connecr 8412 T-piece 8417 Round-square 90 Degree Bend 125 Diameter FLAT DUCTING 8427 Round-square 90 Degree Bend 150 Diameter 8409 Round-square Adapr 125 Diameter 8414 Horizontal 90 Degree Bend 8420 Horizontal 45 Degree Bend 8408 Vertical 90 Degree Bend 8418 Rectangular Pvc Hose 8419 Mounting Strap ROOM TERMINALS 8048 Duct Valve 100 Diameter 8049 Duct Valve 125 Diameter SWITCH 9806 RF Switch - White REPLACEMENT PARTS 9808 Replacement Filter 9809 Replacement Heat Exchanger