HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Similar documents
HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

Building Regulations 2010: What it means to you.

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Installation and Maintenance

Installation and Maintenance

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Ventilation Product range ADVANCE ECO 4 ECO 2

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

HRU ECO 4. installer manual

Small Room Heat Recovery Ventilation

Installation and Maintenance

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Building Regulations Approved Document F1 Means of Ventilation April 2006

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Installation and Maintenance

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Lo-Carbon Sentinel Kinetic Horizontal

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Installation and Maintenance

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

CI/SfB (57.5) November 2008

Installation and Maintenance

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Healthy, comfortable and energy-efficient ventilation

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

Introducing the RetroVent

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

WHHR Midi & Midi Lite

HOTLINE:

MODEL: BV400 Part No:

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

Healthy, comfortable and energy-efficient ventilation

HRV Enthalpy. Catalogue

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Itho CVE ECO 2 RFT. Installer/User manual

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

The Sentinel Kinetic Horizontal Range

Airflex Radial & ISO Thermal pipe

Polypipe Ventilation Specifiers Guide

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MVHR & MEV VENTILATION GUIDE 2017

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Thank you for choosing EnviroVent

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

Zehnder Comfosystems. ComfoAir 180 Datasheet

VENTILATION AND HEAT RECOVERY

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Short Form Ventilation Product Guide

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Intelligent Air Solutions

ComfoAir Q. Mechanical Ventilation and Heat Recovery

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

Put the V back in HVAC

Domestic & Commercial Fans

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

Ventilation. Product Information

Energy Efficient Air Distribution Systems

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Technical Bulletin 005(B) Developed with Building Standards Scotland

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Lo-Carbon Sentinel Kinetic Range Overview

Ventilation & Heat Recovery. The whole house system from OMNIE

Transcription:

NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

BALANCED VENTILATION WITH HEAT RECOVERY Fresh air intake HRU ECO 3 RF Exhaust bathroom Exhaust kitchen Exhaust ilet Designs for the Future With the Government actively encouraging energy saving and a target for all new homes be carbon zero by 2016, the HRU ECO 3 RF has been designed future proof. The Code for Sustainable Homes which came in force in March 2007, details six levels of CO 2 emission improvement over 2006 Building Regulations requirements. To achieve the three highest levels of reduction of carbon emissions, the air leakage of the dwelling must be improved so significantly that continuous ventilation becomes the only appropriate method. In addition, it must be demonstrated that the ventilation system itself must be energy efficient. The HRU ECO 3 RF has been third party SAP Q 1 tested by the Building Research Establishment (BRE) the apropriate SAP Appendix Q test methodology and is Appendix Q eligible. 1 The Governments Standard Assessment Procedure (SAP) is a method assessing the energy performance of dwellings and SAP Appendix Q provides an allowance for the benefits of energy-saving appliances; products may be independently assessed and the results uploaded the SAP website.

Code 9800 - HRU ECO 3 RF Manufactured lightweight material. Patented airtight clamped construction. Complete with Wall Mounting Bracket. Complete with a length of sound insulating fl exible duct. 95% efficient (NEN 5128) Synthetic Counter Flow Heat Exchanger. Aumatic 100% Suer Bypass. Aumatic Frost protection device. 2 x Backward curved centrifugal fans with energy efficient DC mors. G3 Filters on both the Fresh Air Inlet and the Extract. All parts guaranteed against defect for 2 years. Complete with 2 x Wireless Control Switches. 3 speed settings + boost speed timer function (10 30 minutes). Energy Saving: pre-warmed fresh air lowers the heating requirement. Comfort: slow air movement eliminates draughts. Health: constant fresh air supply. Noisy sites: balanced system with no need for trickle ventilars. Exhaust house Fresh air bedroom The 2006 Edition of the U.K Building Regulations Approved Document F1:Means of Ventilation (applicable in England and Wales) details 4 clearly defined systems of ventilation dwellings. System 4 - Continuous mechanical extract with heat recovery (MVHR) is complied with by the new HRU ECO 3 RF ultra-high efficiency whole house heat recovery ventilation system. The system provides quiet, uninterrupted extract ventilation the dwelling, removing warm stale air via all of the wet rooms, creating a permanent air path through the property the dry habitable rooms. Air, drawn in the property by the fan is routed through an integral high-efficiency synthetic heat exchanger where warmth the extracted air is transferred the incoming fresh air before it is supplied the habitable rooms. In employing this type of system, there is no need install background ventilars in the dwelling - an ideal solution noisy sites. To counter increased pollutants caused by cooking or bathing activities, a wireless boost facility allows the fan s balanced extract and supply rates be increased anywhere in the property where an RF Switch is positioned. The HRU ECO 3 RF unit is equipped with an integrated fully aumated suer bypass valve that ensures that, if required, fresh air drawn in the unit fl ows directly in the air supply system instead of through the heat exchanger; in this instance there is no heat transfer between the warmer discharge air and the cooler supply air. This is a definite advantage in the suer, when air is often cooler than air indoors. An integrated fully aumatic frost protection valve ensures that the unit does not freeze during the colder months. Due the unique clamping construction in combination with the plastic/synthetic elements, the weight of the heat recovery unit HRU ECO 3 RF fan is only 25 kg. Fresh air living room Designed and Manufactured by Itho bv and supplied exclusively in the U.K. by Vortice Limited. All exhaust and supply air connections have an internal diameter of 150 and external 180. The connections can be used attach Vortice modular rigid ducting and insulated fl exible aluminium ducts and accessories. Each connection is provided with an illustration that shows the direction and source of the air. Standard NEN 5128 defines the efficiency of heat recovery units for dwellings. As a result of the efficiency determined a certificate of equivalence for the HRU ECO 3 RF fan has been issued. An efficiency of 95% can be used in the EPC calculation. In addition, the product has successfully passed the test requirements of BS EN308:1997: Heat exchangers. Test procedures for establishing the performance of air air and fl ue gases heat recovery devices.

No leakage fresh air exhaust air 1 Heat exchanger tight fitting in the EPP housing. 2 Tape on sides for extra sealing. 3 Bayonet fitting seals the cover the heat exchanger. 4 Patented Clamp Device guarantees air tightness. 1 2 3 4 Labelled duct connection 1 Supply Air House. 2 Fresh Air Outside. 3 Exhaust Air House. 4 Exhaust Air Outside. 1 2 3 4 Ultra quiet operation 1 Quiet fan. 2 Vibrations damper. 3 Absorbtion foam. 4 Air fl ow speed as low as possible. Capacity adjustable. 1 2 3 4

Wireless 3 speed control with timer - RF-Set Timer push 1 x 10 minutes. Timer push 2 x 20 minutes. Timer push 3 x 30 minutes. Normal Operation Mode Frost Protection Mode Suer Bypass Mode

DIMENSIONS () AND CERTIFIED PERFORMANCE EXT. Ø F INT. Ø E D A C B Model Code A Height over Body B Width C Height (over connections) Depth Duct connection int. Ø E ext. Ø F Discharge condensate ext. Protection Filter Grade Weight kg HRU ECO 3 RF 9800 789 730 848 473 150 180 40 IP31 G3 24,1 Mode Capacity Pressure Power Current Voltage Power Facr Cos Phi Thermic performance m 3 /h Pa W A V * % Mode 1 Minimum mode 50 10 8 0,05 230 0,07 98 Mode 1 Low mode 75 20 12 0,1 230 0,55 98 Mode 2 Medium mode 150 40 29 0,24 230 0,53 96,2 Mode 2 Medium mode 150 80 38 0,31 230 0,53 96,2 Mode 3 High mode 225 100 74 0,59 230 0,59 94 Mode 3 High mode 225 150 88 0,69 230 0,56 94 Mode 3 High mode 275 100 106 0,83 230 0,56 93 Mode 3 High mode 275 150 126 0,99 230 0,56 93 Mode 3 Maximum mode 325 100 156 1,22 230 0,56 92 Mode 3 Maximum mode 325 150 176 1,36 230 0,56 92 * Values entered in the EPC calculation NEN 5128

BUILDING REGULATIONS DOCUMENT F1 2006 Continuous mechanical supply & extract ventilation with heat recovery A continuous balanced mechanical central supply and extract system be positioned in loft or cupboard space. An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost. In employing this type of system, there is no need install background ventilars in the dwelling. Continuous supply and extract 1 Determine the whole building ventilation rate Table 1.1B Allow for infiltration by subtracting - for multi srey dwellings: 0.04 x gross internal volume of dwelling heated space (m 3 ). - for single srey dwellings: 0.06 x gross internal volume of dwelling heated space (m 3 ). 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate Table 1.1A. 3 The required air flow rates are as follows: Maximum Extract Rate (boost) is the greater step of 1 and 2 above. The Minimum individual room extract rates should be at least those given in Table 1.1A for minimum high rate Minimum air supply rate should be at least the whole building ventilation rate in 1 above. 4 No Background ventilars are required with System 4. Table 1.1 A Room Minimum intermittent extract rate Continuous rate Minimum high rate Minimum low rate Kitchen 30 l/s (adjacent hob); or 60 l/s elsewhere 13 l/s Utility room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accomodation 6 l/s 6 l/s Total extract rate must be at least the whole building ventilation rate in Table 1.1B Table 1.1 B Number of bedrooms in dwelling 1 2 3 4 5 Whole building ventilation rate (l/s) 13 17 21 25 29 Minimum value in any dwelling of 0,3 l/s per m 2 fl oor area In addition, the minimum ventilation rate should not be less than 0,3 l/s per m 2 internal fl oor area (this includes each fl oor, e.g. for a two-srey building, add the ground and fi rst fl oor areas). This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as thedefault value. If a greater level of occupance is expected, then add 4 l/s per occupant.

ACCESSORIES CODE DESCRIPTION 22020 Fixed Grille 125/150 Diameter (Grey) 8224 Fixed Grille 150 Diameter (White) EXTERNAL TERMINALS AND 8227 Fixed Grille 150 Diameter (Brown) ASSOCIATED COMPONENTS 8230 Fixed Grille 150 Diameter (Beige) 8233 Fixed Grille 150 Diameter (Terracotta) 9104 Semi-rigid Wall Liner 150 Diameter 8136 Spigot Plate 150 Diameter 8340 Insulated Flexible Ducting 100 Diameter X 4 m Length 8331 Insulated Flexible Ducting 100 Diameter X 10 m Length INSULATED FLEXIBLE 8342 Insulated Flexible Ducting 125 Diameter X 4 m Length ALUMINIUM DUCTING 8333 Insulated Flexible Ducting 125 Diameter X 10 m Length 8341 Insulated Flexible Ducting 150 Diameter X 4 m Length 8332 Insulated Flexible Ducting 150 Diameter X 10 m Length 8681 Y-piece 100 Diameter 8682 Y-piece 125 Diameter 8683 Y-piece 150 Diameter 8174 Duct Joining Piece 100 Diameter 8415 Duct Joining Piece 125 Diameter 8672 Duct Joining Piece 150 Diameter 8063 Reducer 125-100 Diameter FLEXIBLE DUCTING COMPONENTS 9239 Reducer 150-100 Diameter 9238 Reducer 150-125 Diameter 9807 Reducer 180-150 Diameter 8039 Worm Drive Clip 100 Diameter 8040 Worm Drive Clip 125 Diameter 8041 Worm Drive Clip 150 Diameter 8042 Worm Drive Clip 200 Diameter 8020 Pvc Sealing Tape 8410 Flat Channel 1,0 m Length 8416 Flat Channel 1,5 m Length 8406 Connecr 8412 T-piece 8417 Round-square 90 Degree Bend 125 Diameter FLAT DUCTING 8427 Round-square 90 Degree Bend 150 Diameter 8409 Round-square Adapr 125 Diameter 8414 Horizontal 90 Degree Bend 8420 Horizontal 45 Degree Bend 8408 Vertical 90 Degree Bend 8418 Rectangular Pvc Hose 8419 Mounting Strap ROOM TERMINALS 8048 Duct Valve 100 Diameter 8049 Duct Valve 125 Diameter SWITCH 9806 RF Switch - White REPLACEMENT PARTS 9808 Replacement Filter 9809 Replacement Heat Exchanger

KOVENT Kumanovska 14, 11000 Beograd Tel. 011 308 57 40 Faks 011 344 41 13 E-mail: office@kovent.rs www.kovent.rs