Knürr RMS Compact II. Knürr RMS Compact II 2.81

Similar documents
Outdoor Temperature Sensor

MiNi Server environment MoNitoriNg SySteM

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Typical applications include the vibration detector. Detection of vibrations and shocks

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

CAN unit for Analog Sensors

AirFlow Sensor for Dry Contact connection

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

IndigoVision Alarm Panel. User Guide

RACK MONITORING SYSTEM RAMOS Ultra

LORAIN CIP 4890/48120 DC Power System

Didactum Monitoring System 50

LORAIN CSP DC Power System

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

EnvironmentalMonitoring

RACK MONITORING SYSTEM - RAMOS Ultra

Data Center. Cold Storage

ECO PDU PE7214/PE7216/PE7324/PE7328

Labkotec Ice Detector

Didactum Monitoring System 100 III

Monitoring Solutions

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Passive infrared ceiling sensor

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

ACTIVE INFRARED BARRIER

Model D12-IR. Digital Gas Transmitter...

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Galaxy Pulsar Plus Digital Battery Plant Controller

DTS MOBATime's Distributed Time System

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

DMFPM-2R MULTIFUNCTIONAL

Fire control panels FC360

Alarm module for leak detection with webserver

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

Instruction Manual Environmental Monitoring Unit with Output Relay

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

CMC-TC Processing Unit II Assembly, Installation and Operation Manual

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

USER MANUAL CONTEG USER MANUAL. for the next decade! CONTEG SOLUTIONS. ...to complete your network. version: CONTEG, spol. s r.o.

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1.

GPS or DCF 77. DTS Masterclock

RSMFM-2R MULTIFUNCTIONAL

UDC100 Universal Digital Controller Specifications

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

idware Idware Remote Site Monitoring Solution

Installation Guide. Ceiling PIR Detector (311) Features and Connections

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

SENSAPHONE 901 Tryens Road Aston, PA PH:

KWX- N1 N2 N3 N4 Remote Monitored PDU

Plug-in Base, Long Range Sensor E3B2

PRELIMINARY EDITION

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Two-Channel Gas Controller

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Panel Mounted Fault Annunciator Series

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Added password for IP setup page : Password must be in IP format!

IntesisBox BACnet/IP Server - Notifier ID3000 series

TELSEC MINI PRO User Guide

REA 105 Arc Protection Module. Operator s Manual

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Innovative Circuit Technology Ltd.

CMC-TC Basic CMC DK

ModBus DE-1 INSTALLATION AND USER MANUAL

Oxygen (O2) Single-Point Gas Detection System

Fire control panels FC726 FC726-XA

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

DS-2TD Thermal & Optical Network Bullet Camera

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

ThermoControl 0 C - 10 C - 20 C - 30 C

PolyGard 2-channel Gas Controller MGC-03

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

Panel Mounted Fault Annunciator Series

Ceiling PIR HS presence detector. Product Guide. Overview. Features

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

EBMHS (standard & slim-line PSU)

ENVIRONMENTAL, POWER & SECURITY MONITORING PROTECT YOUR MISSION-CRITICAL IT EQUIPMENT

SCHMIDT LED Measured Value Display MD Instructions for Use

GUARD YOUR MISSION-CRITICAL IT EQUIPMENT

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Increased safety and reducing energy consumption with the motion control RPI 01

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

EBDSPIR-PRM-LV Product Guide

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

GUARD YOUR MISSION-CRITICAL IT EQUIPMENT ALERTWERKS SERVSENSOR MONITORING HUBS AND INTELLIGENT SENSORS BLACKBOX.

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Transcription:

Knürr RMS Compact II Knürr RMS Compact II 2.82 to 2.85 2.81

Knürr RMS Compact II Damage prevention with checks and controls System and network management requirements mean the systems ambient conditions must be monitored. Reliability and system availability are indispensable. Compliance with the required ambient parameters is extremely important for the fault-free operation of high-grade components. Inadmissible fluctuations in temperature or humidity often cause hardware defects. Constant automatic monitoring of these parameters is therefore a basic requirement for ensuring properly functioning operability. With the rack monitoring systems offered by Knürr, this information can be recorded and forwarded directly to a higher-level management system, e.g. Nagios Liebert Nform TM. This recording is not, however, sufficient to ward off damages. For short response times when faults occur, it is helpful if the monitoring system can perform actions automatically (e.g. activate additional fans). When defined incidents occur, the Knürr RMS Compact II can immediately send a message as an 'SNMP trap' to the management agement system or directly as an e-mail to a technician or an SMS gateway. Rapid fault-finding and removal is extremely valuable! The ability to connect additional sensors to monitoring systems not only allows racks to be monitored so too can complete rooms or building sections. All important environmental parameters of a system can consequently be recorded and evaluated in a simple and straightforward way. The benefits of Knürr s modern rack monitoring system: Guarantees fault-free operation Detects disturbances early Logs incidents Makes service assignments easier with automatic monitoring Activates countermeasures in the event of a fault Central control of consumables (filters, paper, toner, meter readings, inspection intervals, etc.) Connection of up to 12 sensors in any arrangement 2.82

Knürr RMS Compact II RMS20013 RMS20015 - Compact construction - Zero unit solution (for mounting outside the 19 installation area) - 19 installation with adapter bracket - Safe clamping of all connected cables with integrated cable clamping bracket - Cost-effective orderly installation with Plug & Play concept - Convenient cabling with RJ45 sensor - TCP/IP connection via Ethernet (10/100 Base T) - Configuration via SNMP and web browser - Web access is password-protected and optionally encrypted (https) - 3 different user levels - Freely programmable filter system (boolean logic) for implementing all alarm conditions - Compatible with standard network management systems HPOpenView, Cabletron Spectrum, Castlerock, IBM Netview, IBM Tivoli, MG-Soft, Compaq Insight Manager, SUN NetManager, etc. - Sensors for monitoring all current environmental influences (optional) - Internal power supply for sensor equipment (no additional power supply necessary) - Alarms via LEDs, relay, network management or e-mail (SMTP) - Syslog support for continuous external data storage - System time balancing with NTP servers - 12 universally usable sensor inputs for temperature sensors, humidity sensors, digital (on/off) or analog sensors (0...10V) - 3 digital outputs (2 x relay, max. 3A at 230VAC, 1x 750mA at 48VDC) - Power supply: 100 240 VAC - Operating voltage: 12VDC Approvals - CE Symbol in acc. with Low Voltage Directive 73/23/EEC, EMC directive 89/336/EEC Color - RAL 7021 dark gray 1 Knürr RMS Compact II 1 power supply 2 19 mounting brackets 1 power supply mounting bracket 1 CD ROM (with manual, MIB file) - 350 42 170 RMS Compact II 06.108.200.8 1 set ECO Temperature Sensor - Humidity measuring range, 30-90% - Accuracy: +/- 5% LUF20069 RMS compact-specific - Insensitive to disturbances - The sensor does not have to be recalibrated with RJ45 port Order no. UP 06.108.212.9 1 unit - Temperature measuring range, 0-60ºC - Accuracy: +/- 5% ECO 06.108.220.9 1 unit RMS20005 Smoke Detector - Optical smoke detector with VdS approval - For early fire detection with smoke emission - Power supply provided via RMS compact Humidity Sensor - Operates between -20 C and +75 C RMS20019 (similar to picture) RMS compact-specific - Insensitive to disturbances - The sensor does not have to be recalibrated Ø 90 75 06.108.211.9 1 unit 2.83

AC Voltage Monitoring Water Sensor RMS20033 - Monitors the AC power supply via an IEC Euro connector - Signals status via an integrated signal cable to the RMS Compact RMS20031 - Detects presence of water - Operating voltage: max. 24 VDC Monitored AC voltage: Connections: 230 VAC 50/60 HZ IEC plug, RJ45 socket with 2 m connection cable 1 mounting brackets 06.108.217.9 1 unit 06.108.222.9 1 unit Vibration Sensor Door Contact Sensor RMS20019 - Detects vibrations - Theft protection - Reset possible via Viewer software RMS20006 - Magnet bridge sensor, works on every magnetic conductive material (no special mating part required) - Can also be used for monitoring side panels and roof 06.108.213.9 1 unit - Operates between -20 C and +70 C - Switching voltage, max. 200 VDC - Switching current, max. 500mA Fan Speed Sensor 06.108.215.9 1 unit Passive Infrared Movement Sensor - Room monitoring with the latest stateof-the-art technology - VdS approval Classes A + B - Volumetric lens range 2-16 m - Long lens range 29-50 m - Curtain lens range 17-30 m - Manipulation monitoring - Digital fault evaluation - Corner or wall mounting - Automatic detection as analog sensor - Does not have to be recalibrated - Offset and alarm parameters can be set in RMS - Measuring range: 0 to 0.8 l/s - Non-linear measurement, values table: < 0 m/s < 1 V 0 m/s 1 V 1 m/s 1.7 V 2 m/s 2.9 V 3 m/s 4.1 V 4 m/s 5 V (6 V max.) 06.108.214.9 1 unit 20 39 9 06.108.218.9 1 unit Dimensions in mm: W = Width H = Height D = Depth h = installation height d = useful depth L = length Conversion: 1 mm = 0.03937 inch U = standard height unit 1 U = 44.45 mm UP = unit of packaging kg = weight = Express item 1 kg = 2.2046 pound 2.84

Sensor Cable - With 4 m length the cable is used for connecting further analog/ digital sensors or alarm outputs to the sensor input of the Knürr RMS compact II. - One end of the cable has an RJ45 connection. The other end is free. - The RMS automatically detects a sensor, which is connected with this cable, as an analog sensor. - Using the cable a sensor can be supplied with 12 V voltage. Length, 4 m 1 cable 1 layout overview Model L Order no. UP Analog Sensor Cable 4000 06.108.225.9 1 unit Digital Sensor Cable 4000 06.108.224.9 1 unit Sensor Extension Cable - The cable is used for extending RMS compact II sensors. - It consists of a cable with a connected RJ45 plug and a connected RJ45 socket. Length 3 m and 10 m 1 cable Model L Order no. UP Sensor Extension Cable 3000 06.108.223.1 1 unit Sensor Extension Cable 10000 06.108.223.5 1 unit Carbon Monoxide Alarm Sensor - Used for detecting carbon monoxide caused by the burning of fire retardant cables. - Sensor signals carbon monoxide to the RMS and emits a loud alarm sound itself (as carbon monoxide is toxic). - The RMS automatically recognizes this sensor as a digital sensor - Operating voltage: 12 V DC (± 20 %) - Power consumption: approx. 190 ma (calm) approx. 280 ma (alarm) - Sensitivity: 100 ppm CO - Ambient temperature: -15 C to +40 C - Piezo alarm: approx. 85 db(a) at 3 m away - Protection rating: IP 20 - Activated output 12 V DC: max. 170 ma - Relay output: Changeover contact, max. 5 A 230 V DC, max. 5 A 30 V DC - Reset: automatic, when the gas concentration falls below sensitivity Dimensions - Length, 140 mm - Width, 125 mm - Height, 40 mm Color White connection cable Mounting material Instructions Power over Ethernet (PoE) Update Set Model Order no. UP Carbon Monoxide Alarm Sensor 06.108.211.8 1 unit - PoE stands for power supply "over" an Ethernet cable. This saves on costly power supply installations (e.g. WLAN access points) or enables centralized UPS for decentral equipment (e.g. IP phones). - Using the PoE Update Set the RMS can therefore support installations with the corresponding UPS concepts and/or "broom closet" installations. - Input: 48 V DC, 400 ma - Output: 12 V DC (12 W) - Operating temperature: 0 to 40 C - Storage temperature: -40 to 70 C - Operating air humidity: 10% to 80% rel. humidity Dimensions - Length, 81 mm - Width, 52 mm - Height, 28 mm Approvals - EMI: FCC Part 15 Class B, CE Class B - Safety: UL, TUV 1 PoE Adapter 1 mounting bracket for easy attaching on the RMS (similar to the classic power supply mounting bracket) Model Order no. UP PoE Update Set 06.108.230.8 1 unit 2.85