Case study: EconAqua water mist sprinkler system

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Fire protection for buildings

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

FIGHTING FIRE as easy as blowing out a match

Performance Based Fire Protection With Water Mist

VELMIST. System Mgły Wodnej Niskociśnieniowej

Fire fighting excellence. HI-FOG water mist fire protection

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

What is HI-FOG? The natural enemy of fire

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

Fixed fire protection solutions

FOREFRONT AT THE OF PROTECTION

WATER MIST CONVENTION AND EXHIBITION

MORE THAN JUST FIRE PROTECTION

Fire fighting excellence. HI-FOG water mist fire protection

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Installation and Maintenance Requirements

Water Mist Fire Suppression

Water Mist in Care Homes & Hospitals in the Nordic Territory. Henrik Johansson

MORE THAN JUST FIRE PROTECTION

Fire fighting excellence. HI-FOG water mist fire protection

Water Mist v Sprinklers

Fire Suppression Systems

Fire fighting excellence. HI-FOG water mist fire protection

An Overview of Extinguishing Systems for Computer Equipment

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

The History of IWMA. 18th International Water Mist Conference will (IWMC) take place in London on 19th & 20th September 2018

Ceasefire Watermist Hydrant Systems

HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today

Householders Guide to Fire Sprinklers

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

The Science Behind Water Mist Protection of Typical Building Hazards

Watermist Applications and Approvals

Zurich s experience case studies

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Approval of water mist systems in buildings

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today

New Approaches to Design for Fire Safety - Residential sprinklers, open plan flat layouts and water mist

Approved products and systems for water mist systems and VdS 3188 for planning and installation

Nessie High Pressure Water Mist Components for Fire Fighting

Certificate No: EWS534

Minifog EconAqua Water mist sprinkler systems

How can you minimize consequential damages in case of a fire?

The Macro Quallty Assurance System for Fire Safety Engineering

Association of Irish Risk Management An Introduction to Sprinklers 12th September 2012

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Sprinklers in Europe known problems and misconceptions. Alan Brinson

Fire Extinguishing Concepts for Recycling Plants. 1 Fire Extinguishing Concepts for Recycling Plants

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

Emergency shutdown systems. Procedures for bypassing ESD s

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

This document is a preview generated by EVS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

Welcome to Argonite fire protection from Ginge-Kerr

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

FIRE SUPPRESSION SOLUTIONS

What extinguishes fires without pressure peaks?

Fire suppression systems for server rooms and data centres

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler Heads Revised

Illinois Fire Safety Alliance

Innovative Solutions for Active Fire Protection in Road/Rail Tunnels and Underground Facilities

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Protect your occupancy rate

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

that sense s of ecurity

Sprinkler Identification Numbers

Update on European Standardization Work

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Design of Fire safety in Multi Occupancy Residential Accommodation

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

High flying fire protection HI-FOG for aircraft hangars

TECHNICAL DATA NOTICE

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Personal Protection Systems (PPS)

Domestic and Residential Fire Sprinklers Design Policy

PROTECT WHAT YOU VALUE MOST

Worldwide Contacts.

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

Fire protection solutions for ships and offshore facilities

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Transcription:

SUPPLIER OF LOW PRESSURE WATER MIST TECHNOLOGY FOR FIRE SUPPRESSION WWW.PREVENT-SYSTEMS.COM PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY PREVENT SYSTEMS 1

OUR HISTORY INNOVATION The history about our innovative solutions goes back to 1987. Back then our current Head of Technology started developing water mist nozzles for fire suppression. The systems were originally developed for the maritime sector and are found on board cruise liners, ferries and yachts all over the world. When founding Prevent Systems AS in 2007, the focus was shifted to the land-based market. Our innovative solutions have made us a market-leader within research, development and distribution of automatic fire extinguishing systems with low pressure water mist. Prevent Systems was the first company to meet the test requirements for the Nordic residential water mist standard, INSTA 900-3, and the British water mist standards for residential and domestic, BS 8458, and for low hazard occupancies, BS 8489. We were also the first company to obtain LPCB certification for water mist nozzles, listed on RedBookLive.com. More than 25 years of research and development experience enables us to deliver innovative patented fire protection technology to the fast growing residential market, as well as for light- and ordinary hazard applications. This includes apartment buildings, care institutions, hospitals, hotels, office buildings, schools parking garages and cultural heritage buildings.

WE SET NEW STANDARDS FOR FIRE SUPPRESSION AND SAVE LIVES Each year thousands of people die in building fires. In addition to lives lost, fires cost owners and society billions of euros in damages. As a result, authorities around the world are implementing stricter regulations, requiring the installation of automatic fire suppression systems. Especially in buildings that house those most at risk, the elderly and disabled. A solution that is becoming more prevalent and in demand, is water mist. Mainly because it requires significantly less water than traditional fire suppression systems, and is proven to be very effective in controlling and extinguishing fires. The most efficient solution Our patented low pressure water mist technology has been tested in full scale fire tests at SP Fire Research (formerly Sintef NBL, Norway), SP Technical Research Institute of Sweden and BRE Global in the United Kingdom. The comprehensive tests show that our water mist systems suppress a fire as good or better than traditional systems, in the fire tests performed. This is accomplished by exploiting water more efficiently, allowing us to use far less water than traditional systems. The efficiency is due to the fact that the fire is attacked from all three sides of the Fire Triangle simultaneously: Heat - The smaller droplets absorb the heat from the fire, and lowers the temperature quickly. Oxygen - The fine droplets in and around the fire «boils» over from water to steam, or water vapor, which is an inert gas. This conversion to water vapor, dramatically increases the volume of water, up by almost 1700 times. The water vapor displaces the oxygen, and suffocates the fire. Fuel - The droplets that are not converted to water vapor, will wet the surrounding area and prevent the fire from spreading. The combination makes the system unique compared to traditional automatic fire suppression systems. Certified safety Prevent Systems was the first company to obtain certificates for water mist nozzles from Loss Prevention Certification Board, one of the world s most recognized certification institutions. The water mist systems are fire tested in full scale fires at accredited fire laboratories according to international standards, with full documentation for applications to be protected - as regulations require. Applications include hotels, apartment buildings, schools, daycare facilities, office and commercial buildings, care homes, hospitals, institutions and heritage buildings. PREVENT SYSTEMS 3

Loss of lives and damage to the environment Building fires represent approx. 40% of all fires in the world. Most fire deaths occur in private homes while people are asleep. Fire damage results in annual compensations amounts which run into billions of dollars on a worldwide scale. Therefore, many insurance companies reward installation of automatic fire suppression systems in residences and other properties by offering lower insurance premiums. PREVENT SYSTEMS 4

ADVANTAGES OF LOW PRESSURE WATER MIST Fire suppression systems from Prevent Systems are based on low pressure water mist technology. Low pressure water mist offers a large number of advantages both to specialists and users. Advantages which make the solutions attractive compared to traditional systems. Efficient fire suppression Comprehensive fire tests speak for themselves: Our water mist systems control and extinguishes fires at least as good, or better than, traditional suppression systems in tests performed. By exploiting the water more efficiently considerably smaller amounts of water is required compared to traditional sprinklers. Documented and certified Prevent Systems water mist systems are fire tested in full scale fires at accredited fire laboratories according to international standards, with full documentation for applications to be protected. Our water mist nozzles were the first to be certified by LPCB and listed on RedookLive.com Easy and fast installation - Discrete and space-saving design Since our systems require less water, the water intake can be smaller, and all pipes and fittings are smaller. This results in easier and space saving installations, a greater architectural advantage, which is very important to builders, architects, contractors and owners. Water damage proof systems offered WIth the unique PrevPex pipe in pipe system Prevent Systems offers a leakage proof, exchangeable piping system. This system requires that the pipes are filled with water, and that the pipes are installed behind a fire retardant surface. The system is especially well suited for embedding in concrete floor dividers, either poured on-site, or pre-made elements hoisted into place. Eco-friendly high quality components Low pressure water mist technology use small components, which require less amount of material to manufacture, and more eco-friendly to transport and store. All components are of high corrosion free quality, designed to last the life of the building without considerable need for replacement and maintenance. PREVENT SYSTEMS 5

FIRE SUPPRESSION WITH WATER MIST FROM A PRACTICAL STANDPOINT Water mist is defined as water droplets less than 1mm in diameter. Water from the mains or a tank, flows through distribution pipework and is atomized to many very fine droplets, as it passes through a water mist nozzle. Many tiny water droplets create a greater total surface area per liter of water. Combines the size of droplets The water mist solutions from Prevent Systems combine both the small and somewhat larger water droplets. The smaller droplets absorb the heat from the fire and lowers the temperature quickly. The fine droplets in and around the fire boil over from water to steam increasing the volume of water by almost 1700 times. This process displaces the oxygen and suffocates the fire. The droplets that are not converted into water vapour will wet the surrounding area and prevent the fire from spreading. OXYGEN HEAT COMBUSTIBLE MATERIAL In other words, the solution attacks all three sides of the fire triangle effectively! PREVENT SYSTEMS 6

HOW DOES THE WATER MIST AFFECT THE ENVIRONMENT? The water mist solutions from Prevent Systems ensure that the fire suppression system respects the environment. It involves a non-toxic fire-fighting medium with long life high quality components. The water mist systems only require pure water and thus does not contain any poisonous chemicals. The solutions from Prevent Systems are also designed to last the life of the building. We obtain the long durability by way of high quality components with corrosion-proof pipes and parts requiring a minimum of maintenance. Reduced water consumption Water mist is a solution that is becoming more prevalent and in demand. Mainly because it is proven to exploit the water more efficiently and therefore requires significantly less water than traditional fire suppression systems. Reduced material consumption Less water requires a smaller water intake with smaller dimension pipes that are lighter, easier, faster and space-saving to install. The result is significant reduced material consumption and energy consumption in connection with production and transport. PREVENT SYSTEMS 7

24/7 Like having a fireman on watch 24 hours a day An automatic water mist system reacts quickly on temperature. Most fire scenarios are extinguished within few minutes from system activation. 80% 1:1700 The water consumption can be reduced by as much as 80% The water mist solutions are high-efficient and can use as little as one fifth of traditional sprinklers water consumption. 1 litre of water = 1,700 litres of steam Water mist solutions utilise the heat from the fire to reduce water consumption. The heat makes the water expand so 1 litre of water turns into almost 1,700 litres of steam or water vapour, under optimized conditions. PREVENT SYSTEMS 8

SOLUTIONS Low pressure water mist is the automatic fire suppression system of the future. With hundreds of installations, our solutions have proven to be very cost competitive and yielding a very attractive total economy. Our solutions protect thousands of residences and other building types, from hotels, offices and commercial buildings to institutions, schools, day-care facilities, care homes, hospitals and heritage buildings. Residences The water mist solutions offer safety and are connected to the existing water supply with regular water pressure. The solutions are for instance found in 500 apartments at the Bread Factory (Brødfabrikken) in Oslo, Norway. Schools and institutions Low pressure water mist ensures efficient fire protection of schools, kindergartens and other institutions. The solutions are for instance found in the kindergarten called The Building Block (Byggeklossen) in Harstad, Norway. Developer of the project is the Stor-Oslo Eiendom AS Hospitals Extinguishing with water mist makes the following clean- up faster and ensures minimal interruption of daily operations. Commercial premises Offices, shops and other commercial premises are fire protected with low pressure water mist. The solutions are found in several office buildings, e.g. Tykkemyr in Moss, Norway. Hotels Solutions from Prevent Systems are discrete and merge nicely with architecture and interior. For instance, the solutions are found in the Saga Hotel in Oslo, Norway. Buildings worth preserving Water mist solutions are easy to install and ensure safe protection. For instance, the solutions are found in Windsor Castle in the United Kingdom. PREVENT SYSTEMS 9

NOZZLES Nozzles from Prevent Systems are available both as ceiling and wall models. The nozzles are approved for protecting residential, light- and ordinary hazard applications. The nozzles have been tested to the following standards: BS 8458, BS 8489, BS 9252, INSTA 900-3, IMO Res. 265(84) Public Space and CEN Test Protocol Parking V1. Prevent Systems offer 10 years of product guarantee on all nozzles. Prev2exp For light and ordinary hazard applications, including offices, schools, retail and general public space areas in hospitals, hotels, care home institutions, etc. Type of nozzle: Pendent Max coverage area: 16m2 Water pressure: 8.4 bar K-factor: 13.4 Prev2up For light and ordinary hazard applications, including parking car garages, offices, schools, retail and general public space areas in hospitals, hotels, care home institutions, etc. Type of nozzle: Upright Max coverage area: 16 m2 Water pressure: 8.4 bar K-factor: 13.4 Prev3exp For residential and domestic applications including homes, care institutions, apartment buildings, and sleeping areas in hospitals, hotels etc. Type of nozzle: Pendent Max coverage area: 16m2 Water pressure: 5.2 bar K-factor: 14 Prev3con For residential and domestic applications including homes, care institutions, apartment buildings, and sleeping areas in hospitals, hotels etc. Type of nozzle: Pendent Max coverage area: 16m2 Water pressure: 5.2 bar K-factor: 14 Prev4sw For residential and domestic applications including homes, care institutions, apartment buildings, and sleeping areas in hospitals, hotels etc. Type of nozzle: Sidewall Max coverage area: 16m2 Water pressure: 8bar K-factor: 12.4 Prev5exp For light and ordinary hazard applications, including offices, schools, retail and general public space areas in hospitals, hotels, care home institutions, etc. Type of nozzle: Pendent Max coverage area: 16m2 Water pressure: 2.4 bar K-factor: 30 Prev5exp20 For residential and domestic applications including homes, care institutions, apartment buildings, and sleeping areas in hospitals, hotels etc. Type of nozzle: Pendent Max coverage area: 20,25m2 Water pressure: 2.2 bar K-factor: 29 Proud member of: PREVENT SYSTEMS 10

PUMP-SETS AND PIPING SYSTEMS Our pump-sets are developed in partnership with Grundfos, which produces and delivers pump-sets in accordance with current standards. We offer complete approved piping systems to our low pressure water mist systems. Most commonly used is PrevPex Pipe-in-Pipe, Pressfitting systems in stainless steel and RedPipe in PP-R - all of course corrosion-free systems. Pump-Set for residential purposes Our CM pump-sets are delivered in accordance with current standards. Pump-Set for ordinary hazard class (OH) Our CR pump-sets are delivered in accordance with current standards. PrevPex PrevPex is a leakage-proof and replaceable pipe-in-pipe system for use in Prevent Systems Low Pressure water mist systems, based on JRG Sanipex system manufactured by Georg Fischer AG. Well suited to be embedded in concrete. Stainless steel Pressfittings piping system in stainless steel 316L quality, VdS certified. Redpipe Pipe system in fiberglass PP-R is corrosion-free, VdS and LPCB certified. Please refer to the respective data sheets and Prevent Systems Design, Installation, Operation & Maintenance (DIOM) manual for detailed information on components. PREVENT SYSTEMS 11

WWW.PREVENT-SYSTEMS.COM PLEASE TAKE YOUR FIRE SAFETY SERIOUSLY! DON T WAIT! CONTACT US TODAY +vonbülow.co Fåberggaten 126 2615 Lillehammer Norway T: +47 612 60 909 www.prevent-systems.com