CMA5000 OTDR Module Series

Similar documents
Product Introduction. CMA5000a OTDR

White Paper. Optical Installation and Maintenance

Product Brochure MT9090A. Network Master Series. MU909011A Drop Cable Fault Locator Modules 780nm and 1550nm OTDR for Single Mode Fiber

Advanced Test Equipment Rentals ATEC (2832)

Product Brochure MT9083A. ACCESS Master. 850/1300 nm OTDR for MMF 780/1310/1383/1490/1550/1625/1650 nm OTDR for SMF

MT9080 Series. ACCESS Master TM. 1.31/1.55/1.65 µm (SM)

MT9083 Series. MT9083A/B/C ACCESS Master. 850/1300 nm OTDR for Multimode Fiber 780/1310/1383/1490/1550/1625/1650 nm OTDR for Single Mode Fiber

A truly revolutionary OTDR

MTTplus Modular Test Platform

M700-Series Multifunction OTDR

FLX380-30x FlexTester OTDR

Network Master Series


M700-Series OTDRs. or (800) , (603)

Advanced Test Equipment Rentals ATEC (2832) Product Brochure. CMA5000a. Multi-layer Network Test Platform

Noyes OFL 250B Specs Provided by

MW9070B Optical Time Domain Reflectometer

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

Network Master Series

palmotdr Series Handheld OTDR

VIEW500 FASTEST STANDARD OTDR

palmotdr Series Handheld OTDR

FTS510 Series. Handheld OTDR Test Set.

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

CMA4000i Optical Test System

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

VIEW500 USER-FRIENDLY STANDARD OTDR

MINI2 MOST ACCURATE COMPACT OTDR

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

FTS500 Series. Handheld OTDR Test Set.

FLX380-30x FlexTester3 OTDR

FHO5000 Series Triple-Proof OTDR

OTP6123 Series. Handheld OTDR Test Set.

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

MT9083 Series MT9083A2/B2/C2 ACCESS Master

Fiberizer IIT-6000 Series

AE2200 FTTx Multi-Function Meter

M210 Multifunction Micro OTDR

High cost performance choice

High cost performance choice

Network Master Series

AV6416 OTDR. Product Overview: Main Features:

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Network Master Series

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Intelligent Optical Link Mapper (iolm)

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

M210 Multifunction Micro OTDR

OPX-BOX. Platform Highlights. Software Support. Key Features

VePAL FX300 Fiber Expert OTDR

ACCESS Master MT9085 Series. Product Introduction

Acterna MTS 5000 e Series OTDR and Loss Test modules

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

MT9085 Series ACCESS Master

OFL280-10x FlexTester OTDR

GRANDWAY FHO5000 series OTDR

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

THE ENTRY-LEVEL SOLUTION DESIGNED FOR ALL YOUR TESTING NEEDS

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

Network Master Series

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

FOT-930 MaxTester MULTIFUNCTION LOSS TESTER

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

Network Master Series

M310 Data Center OTDR

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

OPX-BOXe Rugged, Pocket-sized Mini OTDR

Fibre Characterisation and FTTx New challenges

AXS-100. Series NETWORK TESTING OPTICAL HANDHELD OTDR. Compact, rugged, lightweight OTDRs optimized for access/fttx and LAN/WAN network testing

Network Master Series

SunLite OTDR+ Platform Highlights. Key Features. Power meter, light source, fiber inspection probe and VFL options

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

MaxTester 730B FTTx/MDU PON OTDR

Table of Contents 1Q08. Test & Inspection

M210 Multifunction Micro OTDR

AXS-100 Series HANDHELD OTDR. Telecom Test and Measurement

OptiFiber Pro OTDR Built for the enterprise

Terahertz Technologies Inc.

FG-750 Client API SDN-READY INTELLIGENT OTDR

Return loss measurement of fiber optic components

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

FX150 OTDR. Platform Highlights. Key Features

Advanced Fiber Optic Test Equipment Terahertz Technologies Inc.

Fibre Optic Basics FIA Summer Seminar 2014

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

AQ7275 OTDR Optical Time Domain Reflectometer

AQ7275 OTDR Optical Time Domain Reflectometer

MaxTester 730B PON/METRO OTDR

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

VePAL FX300 Portable OTDR, Optical Power Meter, Visual Fault Locator, and Laser Source Test Set

MW9060A Optical Time Domain Reflectometer

MULTI FIELD TESTER OTDR. All-in-One handheld optical fiber network test tool

Transcription:

Anritsu 5266-000 Specs Provided by www.aaatesters.com CMA5000 OTDR Module Series Optical Domain Reflectometer SPECIFICATIONS The compact size of the OTDR Application module allows another module (OTDR or test fiber box) to be inserted into a small bay adapter and up to three more into a medium or large bay adapter. The CMA5000 Optical Time Domain Reflectometer (OTDR) application represents the latest offering from a company that s been in the OTDR business for over 25 years. Our world class OTDR modules continue this tradition with the latest in high performance hardware and dedicated, easy to use software. Benefits Never obsolete - modular design allows new or additional modules to be added Sophisticated analysis software provides consistent and accurate fiber characterization Dedicated testing modes simplify commonly performed tasks Easy to use for any skill level - testing from fault location to advanced analysis Dual touch screen and hard key user interfaces ensure smooth and efficient operation Solutions for all network types: Metro, CWDM, ultra-long haul and PON based, FTTP deployments Complete fiber characterization from 8 available wavelengths Automated, on-the-box reporting High Performance Hardware To satisfy even the most demanding testing requirements, the CMA5000 series OTDR modules, feature a multitude of available wavelengths including 850 nm, 1300 nm, 1310 nm, 1383 nm, 1410 nm, 1490 nm, 1550 nm and 1625nm.. Up to four of these wavelengths can then be combined into a single optical port providing full spectrum fiber characterization at the press of a button and are ideal for testing backbone or metro networks that deploy CWDM. For ultra-long haul systems, the CMA5000 OTDR modules feature up to 50 db of dynamic range (enough to see approximately 250 km of fiber) - with an impressive 1 meter resolution. ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 1 of 10

Dedicated, Ease to Use Software To simplify testing, the CMA5000 features dedicated testing modes to automate and simplify the task at hand. FAULT LOCATE mode is designed for the novice just starting out or someone who only uses an OTDR occasionally. Simply connect the fiber and press test, the unit will verify the fiber is connected correctly, select testing parameters, execute the test and provide a text response indicating fault/break location and end to end loss. Fig.1: Fault Locate Mode - ease to read results For those who have more experience or would like to perform more advanced testing, CLASSIC OTDR mode allows the user to select all parameters, compare up to eight traces and even generate splice loss reports. Fig.2: Classic OTDR - advanced testing ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 2 of 10

Cable commissioning is also automated through the use of CONSTRUCTION OTDR mode where a wizard allows the user to select the required testing wavelengths, number of fibers and file naming scheme. The wizard then becomes the project manager guiding the user through the testing and ensuring consistency with testing parameters and file naming - virtually eliminating user induced errors. Fig.3: Construction OTDR - automated multi-fiber testing Challenging new architectures such as Fiber-To-The-x (FTTx) deployments that incorporate Passive Optical Networks (PON) are also easily addressed with our exclusive PON MODE solution featuring dead zones as small as 1 meter and the ability to classify up to a 1X32 splitter. Fig.4: PON Mode - Exclusive testing solution optimized for splitter based networks. Reflectance and Optical Return Loss With data rates increasing and video applications growing exponentially, reflectance and optical return loss (ORL) become key parameters that will make or break your network. To simplify testing these, NetTest has developed a unique OTDR based, ORL application that provides meter accuracy, combined with the trouble-shooting ability of an OTDR to add the expertise you need in testing today s demanding optical systems. Simply connect the fiber, enter your PASS/FAIL threshold and press test. If a test fails ORL, a quick press of our exclusive troubleshooting key presents a table listing the top three contributors to the failing ORL - complete with location. By identifying the problem connector, technicians will save hours of random troubleshooting time. The ORL option also functions as a 1 km single mode launch box increasing its value. ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 3 of 10

Added Value To further increase the value of your CMA5000 OTDR, it can be equipped with one of two integrated power meters (standard or CATV), a high output stabilized light source and integrated Visual Fault Locator (VFL). These options are integrated into the single slot OTDR module and do not require an additional module slot like some other solutions. In addition, all OTDR wavelengths are available as stabilized light sources reducing the equipment cost and providing a complete end-to-end loss testing solution. Whatever your testing needs, our world-class OTDR products are designed to reduce the time to install, commission and maintain fiber spans. Specifications Single Mode Models Specifications 6 Optical fiber Model Wavelength type Pulse width 1 Dynamic Range (SNR=1) 2 Deadzone (back-scattered) 3 Deadzone (Fresnel) 4 5225 5235 5236 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 ns 37/36 db 9/9m 4/3.5m 40/40 db 8/6m 4/3m 40/40/40 db 8/6/6m 4/3/3m 1625±15 nm 5245 5, 10, 20, 50, 100, 43/45 db 10/10m 5/5m 200, 500, 1000, 5246 5254 1625±15 nm 1550±20 nm Single Mode (8-10 um) 2000, 5000, 10000, 20000, 30000 ns 43/45/43 db 10/10/10m 6/5/5m 50 db 10m 5m 5281 1383±3 nm 40/38/41 db 8/9/6m 4/5/3m 5283 1383±3 nm 1625±15 nm 5491 5 1490±10 nm 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 ns 35/35/35/35 db 8/9/6/6m 4/5/3/3m 40/40/40 db 6.5m 1.7m 5493 5 Notes 1490±10 nm 1625±15 nm 37/37/37/37 db 6.5m 1.7m 1 2 3 4 5 6 Range dependent SNR=1 with up to 256k averages (typical, subtract approximately 2 db of range to 98% peak noise. Bellcore/Telcordia TR-TSY-000196 Issue 2) Deadzones measured on -45 db reflections (typical) Using Bellcore/Telcordia TR-TSY-000196 Issue 2 (typical) For 549x Modules, the End-to-End Loss Accuracy for Class B PONs is +/- 0.75dB (typical) At 23º C, 10us pulsewidth ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 4 of 10

Quad Single Mode/Multimode and Multimode Models Model Wavelength 6 Optical fiber type Pulse width 1 Dynamic Range (SNR=1) 2 Deadzone (back-scattered) 3 Deadzone (Fresnel) 4 5260 Multimode(50 um), SingleMode(8-10 um) Singlemode: 5, 10, 20, 50, 100, 200, 500, 1000, 24/26/35/35 db 7/8/10/10m 5/5/5/5m 850±30 nm 2000, 5000, 5261 24/26/35/35 db 7/8/10/10m 5/5/5/5m 1300±30 nm 10000, 20000 ns Multimode(62.5 um), Multimode: 5, 20, SingleMode(8-10 um) 50, 100, 200, 5262 500, 24/26/40/40 db 7/8/10/10m 5/5/5/5m 1000 ns 5266 850±30 nm Multimode(62.5 um) 5, 20, 50, 100, 24/26 db 5/7m 2.5/2.5m 1300±30 nm 200, 500, 1000 5269 Multimode(50 um) ns 24/26 db 5/7m 3/3m Notes 1 Wavelength and range dependent 2 SNR=1 with up to 256k averages (typical, subtract approximately 2 db of range to 98% peak noise. Bellcore/Telcordia TR-TSY-000196 Issue 2) 3 4 5 Deadzones measured on -45 db reflections (typical) Using Bellcore/Telcordia TR-TSY-000196 Issue 2(typical) At 23º C, 10us pulsewidth Common Specifications Single mode: 5, 20, 50, 75, 125, 250, 300 km Distance 1 Range Multimode: 5, 15, 20, 40, 64 km Single mode: 0.125, 0.5, 1, 2, 4, 8, 16 m Sampling resolution 1 Multimode: 0.125, 0.5, 1, 2, 4 m Sampling Points Up to 256,000 IOR settings 1.300000-1.700000 Distance Measurement Accuracy 0.0025% of distance measurement± distance resolution ± index uncertainty Loss Measurement accuracy (linearity) ±0.04 db/db Loss Resolution 0.001 db Laser Safety Meets IEC60825-1 Class I and CDRH Class 1 Requirements (Eye Safe) 21 CFR 1040 Optical Connector Operating Modes Single mode: Universal with UFC, USC, UST, AFC, ASC Multimode: Universal with FC, SC, ST Fault Locate, Standard OTDR, Construction (Automated Multi-wavelength, Multi-fiber testing), NetWorks (data processing and report generation) Optional: Power Meter, Stabilized Light Source, Visual Fault Locator (VFL), Video Inspection Probe (VIP) Notes 1 Wavelength and range dependent ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 5 of 10

Loss Test Set Option Specifications (optional) Type Single Mode (8-10 um) Laser (same wavelength and specs as OTDR) Multimode (50 or 62.5 um) LED (850/1300±30 nm) Stabilized Light Source 2 Output -8 dbm (min) -25dBm (min) Stability 1 ±0.2 db (8 hours) +0.1 db (8 hours) Modes of Operation CW, 1 KHz, 2 KHz Power Meter Visual Fault Locator3 Connector Type Detector Type Wavelength Range Calibrated Wavelengths Power Range Resolution Accuracy Linearity Connector Type Wavelength Output Transmission Modes Connector Type Same as OTDR InGaAs 780-1800nm 850, 1300, 1310, 1490, 1550, 1625 nm Standard:+10 to -55 dbm CATV: +20 to -45 dbm 0.01 db, 0.01 watts ±4% (+5 to -50 dbm), ±8% (+10 to +5 dbm, -50 to -55 dbm) ±0.10 db (+5 to -50dBm) Universal (uses LP-XX adapters) 650±20nm 0 dbm into 9/125um fiber (max) CW, 2Hz 2.5 mm universal Safety IEC 60825-1 Class II, FDA (21 CFR 1040. 10 Class 2) Notes 1 2 3 At 23º C Quad models 5260, 5261, 5262 only feature single mode light sources. VFL not available on 5260, 5261 or 5262 ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 6 of 10

Ordering Information The CMA5200 OTDR s are Single Bay modules that include one OTDR/Source Universal Adapter (UC-130-XX) at no charge. For units with a Power Meter option, a Meter Connector Adapter (LP-XX) is also included at no charge. Module Number: 52 - _- OTDR - _ A B C A = Select an OTDR ModuleModule (Additional OTDR modules are available in various combinations of wave lengths and dynamic ranges. Please contact Anritsu for for a comprehensive list.) 25 = Singlemode, 37/36 db dynamic range, dual-wavelength 1310/1550 nm 35 = Singlemode, 40/40 db dynamic range, dual-wavelength 1310/1550 nm 36 = Singlemode, 40/40/40 db dynamic range, tri-wavelength 1310/1550/1625 nm 45 = Singlemode, 43/45 db dynamic range, dual-wavelength 1310/1550 nm 46 = Singlemode, 43/45/43 db dynamic range, tri-wavelength 1310/1550/1625 nm 54 = Singlemode, 50 db dynamic range, single-wavelength 1550 nm 60 = Quad 24/26 db 850/1300 nm 50 μ m multimode and 35 db 1310/1550 nm single mode 61 = Quad 24/26 db 850/1300 nm 62.5 μ m multimode and 35 db 1310/1550 nm single mode 62 = Quad 24/26 db 850/1300 nm 62.5 μ m multimode and 40 db 1310/1550 nm single mode 63 = Quad 24/26 db 850/1300 nm 50 μ m multimode and 40/40 db 1310/1550 nm single mode 66 = Multimode 24/26 db dynamic range, dual-wavelength 850/1300 nm, 62.5 μ m 69 = Multimode 24/26 db dynamic range, dual-wavelength 850/1300 nm, 50 μ m 81 = Singlemode, 37 db dynamic range, tri-wavelength 1310/1383/1550 nm 83 = Singlemode, 37 db dynamic range, quad-wavelength 1310/1383/1550/1625 nm 91 = Singlemode, 40 db dynamic range, tri-wavelength 1310/1490/1550 nm 93 = Singlemode, 37 db dynamic range, quad wavelegth 1310/1490/1550/1625 nm B = Select Meter, Light Source and VFL Options (VFL is not available on 5260, 5261 or 5262 module) 000 = No Meter, Light Source or VFL 001 = VFL Only 110 = +10 dbm Meter and Light Source 111 = +10 dbm Meter, Light Source and VFL 210 = +20 dbm Meter and Light Source 211 = +20 dbm Meter, Light Source and VFL C = Select Connector (APC not available on multimode, for Quad 60, 61, 62 or 63 refer to next section) UFC = FC/UPC AFC = FC/APC USC = SC/UPC ASC = SC/APC UST = ST/UPC AST = ST/APC C = Connector Options for Quad units (60, 61, 62, and 63 only) Select connector for each port. ( 1 2 3 : 1 = SM port, 2 = MM port, 3 = PM port) 0 = none 1 = UFC 2 = USC 3 = UST 4 = AFC 5 = ASC 6 = AST 7 = DIN 8 = LC ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 7 of 10

Example of Order Number and Specification 5236-110-OTDR-AFC 5266-001-OTDR-UFC Singlemode, 40/40/40 db dynamic range, tri-wavelength 1310/1550/1625 nm, Power Meter and Light Source with FC/APC connector Multimode 24/26 db dynamic range, dual-wavelength 850/1300 nm, 62.5 μ m, VFL, with FC/UPC connector ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 8 of 10

Related Anritsu Products MT9083A ACCESS Master Anritsu s new line of MT9083A ACCESS Master OTDRs provides all the measurement functions and performance required for optical fiber construction and maintenance of access, FTTx, LAN and metro networks in a compact, lightweight, all-in-one unit that eliminates the burden of carrying many different test sets and instruments on-site. The ACCESS Master MT9083A is the first all-in-one tool that does not compromise performance. It features extremely high resolution to see those closely spaces splices and connectors, while still being able to certify 100+ km spans- quickly and accurately. In addition to verifying the integrity of the fiber plant, network performance can also be verified ensuring the customer experience is at its highest level. Whatever your work, construction or maintenance, long haul or intrabuilding, Anritsu has an MT9083A model for your needs. CMA50 Optical Loss Test Set All-in-one light source, power meter, visual fault locator and optical return loss meter for optical fiber construction and maintenance. They are offered with common calibration wavelength and connector options to meet any testing requirement from FTTx networks to long haul telephony links to multimode LAN, and CATV. CMA5 Optical Power Meter and Light Source The CMA5 Series Power Meters are ideal for attenuation and power throughput measurements on point-to-point fiber optic links. The CMA5 Series Light Sources provide an economical and stable laser source for use in point-to-point attenuation measurement. They feature a rugged design, built to withstand the difficult testing environment of fiber optic cable installation and maintenance. CMA 3000 Mobile and Fixed Access Network Tester CMA 3000 is designed specifically for field technicians who install and maintain mobile-access and fixed-access networks. The CMA 3000 is a powerful tool for a wide range of applications, including fast first-aid troubleshooting to comprehensive, in-depth and all-layer analysis of transmission problems. The basic CMA 3000 configuration, with its two 2 Mbps receivers and transmitters, supports framed and unframed testing and monitoring of 2 Mbps systems. ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 9 of 10

Anritsu Corporation 5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1264 U.S.A. Anritsu Company 1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-ANRITSU (267-4878) Phone: +1-972-644-1777 Fax: +1-972-671-1877 Canada Anritsu Electronics Ltd. 700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006 Brazil Anritsu Electrônica Ltda. Praca Amadeu Amaral, 27-1 Andar 01327-010-Paraiso-São Paulo-Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940 Mexico Anritsu Company, S.A. de C.V. Av. Ejército Nacional No. 579 Piso 9, Col. Granada 11520 México, D.F., México Phone: +52-55-1101-2370 Fax: +52-55-5254-3147 U.K. Anritsu EMEA Ltd. 200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582-433280 Fax: +44-1582-731303 France Anritsu S.A. 16/18 avenue du Québec-SILIC 720 91961 COURTABOEUF CEDEX, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65 Germany Anritsu GmbH Nemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49 89 442308-0 Fax: +49 89 442308-55 Italy Anritsu S.p.A. Via Elio Vittorini, 129, 00144 Roma, Italy Phone: +39-06-509-9711 Fax: +39-06-502-2425 Sweden Anritsu AB Borgafjordsgatan 13, 164 40 KISTA, Sweden Phone: +46-853470700 Fax: +46-853470730 Finland Anritsu AB Teknobulevardi 3-5, FI-01530 Vantaa, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111 Denmark Anritsu A/S Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark Phone: +45-72112200 Fax: +45-72112210 Spain Anritsu EMEA Ltd. Oficina de Representación en España Edificio Veganova Avda de la Vega, n 1 (edf 8, pl 1, of 8) 28108 ALCOBENDAS - Madrid, Spain Phone: +34-914905761 Fax: +34-914905762 United Arab Emirates Anritsu EMEA Ltd. Dubai Liaison Office PO Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suit 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460 Singapore Anritsu Pte Ltd. 60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533 India Anritsu Pte. Ltd. India Branch Office Unit No. S-3, Second Floor, Esteem Red Cross Bhavan, No. 26, Race Course Road, Bangalore 560 001, India Phone: +91-80-32944707 Fax: +91-80-22356648 P.R. China (Hong Kong) Anritsu Company Ltd. Units 4&5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone: +852-2301-4980 Fax: +852-2301-3545 P.R. China (Beijing) Anritsu Company Ltd. Beijing Representative Office Room 1515, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 10004, P.R. China Phone: +86-10-6590-9230 Fax: +86-10-6590-9235 Korea Anritsu Corporation, Ltd. 8F Hyunjuk Building, 832-41, Yeoksam dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604 Australia Anritsu Pty Ltd. Unit 21 / 270 Ferntree Gully Road, Notting Hill, Victoria 3168 Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255 Taiwan Anritsu Company Inc. 7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817 ISO 9000:2001 certified. ICMA5KOTDR-SPEC04-0804-A4 2008 Anritsu. All Rights Reserved. Page 10 of