FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

Similar documents
FIRE DOOR CLOSING SYSTEMS

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

FireCurtain STANDARD, gray, with steel slats UL & C-UL LISTED. Phone: RAYNOR Fax:

SECTION Overhead Coiling Doors

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

ROLLING SERVICE FIRE. Product Line COUNTER FIRE INTEGRAL FRAME & SILL FIRE INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

MANUAL RESET ALARM RELEASE

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

MANUAL RESET ALARM RELEASE

MD Series MEDIUM DUTY SERVICE DOORS. superior product + recognized value

Smoke and Fire Curtains

Fire Sprinkler Plan Submittal Form

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

UNDERSTANDING SAFETY CABINETS

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

AL800ULADA. NAC Power Extender. Installation Guide

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Firetex steel fire shutters

R OL L ING F IR E DOOR T E S T ING P R OGR AM

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Distributed By: M&M Control Service, Inc Building Technologies

AUTOCALL FIRE DETECTION SYSTEMS.

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Dependable Solutions for Gas Detection

Conceal-Alarm Series FA100 & FA900. ETL listed to UL standards UL1971, UL1480, UL464

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

SAFEPATH SAFEPATH. Emergency communications system

NFPA 80 Overview January 21, 2016

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Residential Fire Protection

Product datasheet High speed door Albany HS9010PEM. ASSA ABLOY Entrance Systems

Get Your Firehouse Connected with the Next Generation of Commercial Door Operators from LiftMaster.

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

GENERAL AREAS OF INSPECTION

THE INTELLIGENCE BEHIND THE MOST INNOVATIVE FIRE DETECTION SYSTEMS

Operation & Maintenance Manual

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

csw-200 intro d u c t i o n

Intelligent Earliest Warning Aspirating Fire Detector

Hand Chain (Model FCF) &

good things in small packages

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

TOTALPAC2 Integrated Fire Protection System

rpsa FIRE PROTECTION ENGINEERS

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

OWNER S MANUAL. Extended Performance Release Device. Models: Firefly III Plus, Firefly III Plus with Voiceboard

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Across-the-Line SERIES MP300 Combined Manual and Automatic

Motorised Infrared Optical Beam Smoke Detector. User Guide

CHIMNEYS AND VENTS CHAPTER 8

green&clean multi-rinse Rack Type, Energy Saving Device, medium

Innovative protection that combines power and flexibility

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

electric, 150r/h, R>L Warewashing Warewashing green&clean multi-rinse Rack Type, Energy Saving Device, large dryer, electric, 150r/h, R>L

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

MANUAL RESET ALARM RELEASE BOX

INSPECTION AND TESTING FORM

OWNER S MANUAL MODEL FDCL C

2409/2900. Fire Guard

Motorised Infrared Optical Beam Smoke Detector. User Guide

Detection, and Suppression Systems

DCSS (ACB) Data Center Fire Suppression Procedures

Refrigerators. Upright Blood Bank. i.series Horizon Series

Variable Frequency Drive SERIES MP800 VFD

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

SECTION AIR DUCT ACCESSORIES

electric, 150 r/h, left>right Dishwashing Dishwashing Multi-rinse Rack Type Dishwasher with Energy Saving Device, electric, 150 r/h, left>right

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

2408/2900. Fire Guard

Safety Tips for the Office

Transcription:

FIRE DOOR AlarmGard & FireGard Preferred door solutions.

PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the United States. These fires caused 3,275 civilian deaths, 15,775 civilian injuries, and $11.6 billion in property damage. Cookson fire solutions help save property, and more importantly, lives. Our advanced Fire Door Systems offer industry-leading, intelligent operation and will: Activate thermally or electrically to contain fire and stop smoke migration Cookson Rolling Fire Doors are the clear and reliable choice for building owners and designers who demand the highest level of life safety and fire protection available with the lowest cost of ownership in a modern, easily integrated package. 2

ROLLING FIRE DOORS Custom Built for Everyday Use Our Rolling Fire Doors, designed for fire rated openings, provide security and access control for use in openings that are not part of a required means of egress. Factory Mutual UL listed for fire protection ratings of 3 and 4 hours. STANDARD COMPONENT MATERIALS AND FINISHES Curtain Galvanized steel with GalvaNex finish in Gray, Tan, White or Brown Bottom Bar Steel with powder coating in Gray, Tan, White or Brown Guides Steel with powder coating in Gray, Tan, White or Brown Steel Brackets Steel with powder coating in Gray, Tan, White or Brown Hood Galvanized steel with GalvaNex finish in Gray, Tan, White or Brown OPTIONAL MATERIALS AND FINISHES Stainless steel SpectraShield powder coating in more than 180 colors ADDITIONAL BRACKET AND GUIDE OPTIONS Hot-dip galvanizing on steel components Zinc enriched corrosion resistant powder coating in gray POPULAR OPTIONS PERFORMANCE UPGRADES Vis ision ion Wi ndows Cus tom Graph ics Win d Lo ading SmokeShield - UL "S" leakage-rated assembly provides protections against the migration of smoke and gasses. Firemiser Insulated Rolling Fire Doors Provides energy savings, sound attenuation and climate control. STC rating of 32. Flame spread and smoke development index 0. 3

RATED COUNTER SHUTTERS Custom Built for Everyday Use Our Rolling Counter Shutters protect interior corridors and create structural seperation in openings where lifesafety is a priority. For use in rated walls, masonry or dry wall with metal or wood studs, our counter shutters can also be used to close full-sized door openings when compact components are required. STANDARD COMPONENT MATERIALS AND FINISHES Curtain Galvanized steel with GalvaNex finish in Gray or Tan Bottom Bar Steel with powder coating in Gray or Tan Guides Steel with powder coating in Gray or Tan Steel Brackets Steel with powder coating in Gray or Tan Hood Galvanized steel with GalvaNex finish in Gray or Tan OPTIONAL MATERIALS AND FINISHES Stainless steel SpectraShield powder coating in more than 180 RAL colors ADDITIONAL BRACKET AND GUIDE OPTIONS Zinc enriched corrosion resistant powder coating in gray POPULAR OPTIONS PERFORMANCE UPGRADES SmokeShield UL S leakage rated assembly Integral Frame and Sill Factory-welded frame and sill configuration for a built-in look. Available Rated Counter Top Vision ion Wi nd ows Cus ustom Graph aphic ics 4

THE IMPORTANCE OF CHOOSING THE RIGHT FIRE DOOR CLOSING SYSTEM Fire doors are mandatory. A closing system can be custom tailored to your needs. Why not choose one with installation is complete? ALARMGARD Alarm Activated Select AlarmGard if you want the most advanced closing system that closes your doors as soon as fire is detected and features hands-free reset. FIREGARD Fusible Link Activated Select FireGard if you want a fusible link closing system that is economical and easy to use. FUNCTION BENEFIT MOTOR TUBE MOTOR* CHAIN OR CRANK MOTOR CHAIN OR CRANK Wires directly to fire alarm control panel without adding a separate release device Integrated connection to create a cleaner look and simplified installation Automatic close initiated by signal from fire alarm control panel Doesn't require human interaction to reset to fully operational status Operates fail-safe Closes in advance of smoke or high temperatures reaching the opening - compartmentalizing the fire O O Automatic close may be initiated by fusible link Performs its intended function in the event of power loss or electrical notification (fusible links are not fail-safe) O O Automatically resets upon alarm clearing or restoration of power Suitable where connection to alarm system is not required or power is not available O O O Does not require manual resetting of Eliminates downtime and maintenance costs associated with resetting process Allows for routine and simple testing of system to occur in minutes Can be tested at floor level with no need for hazardous ladders or resetting tools O O May be retrofit to other manufacturers' doors Gain the benefits of our advanced closing systems without requiring a new fire door and keep existing UL or FM labels Controlled and safe rate of descent 9-12 ips Prevents potential danger to building occupants or objects in the opening when the door closes * Available for Counter Fire Doors x Available as a Standard o Available as an Option 5

CLOSING SYSTEM RELEASE DEVICES Automatic Response in an Emergency If a fire or smoke event occurred in the school pictured here, you would want your fire doors to immediately react to the central alarm signal, causing them to close and prevent the spread of smoke and fire so students could exit safely. Our fire door closing systems can be ordered with an integrated or optional release device, which will respond immediately when the alarm signals and when you need it most. AlarmGard Integrated Fail-Safe Release Device INTEGRATED RELEASE DEVICE On-Board Closing Device The AlarmGard Closing System comes already equipped with an integrated failsafe release device, making it the superior choice for applications where there is minimal wall space for additional devices, or where the coil box must be recessed into the ceiling construction. Activates Door to Close from Alarm Signals Alarm Clears Requires Minimal Headroom Clearance Faster Installation Times Clean, Streamlined Appearance FireGard Optional Release Device OPTIONAL RELEASE DEVICE FUSIBLE LINKS Wall Mounted Closing Device The FireGard Fusible Link Closing System can be ordered with an optional fail-safe release device, which will respond to alarm signals and permit the fire door to close before smoke migration occurs or before high temperatures melt the fusible link. The FireGard space for the installation of the device and where aesthetics are less important. 6

CLOSING SYSTEM ACCESSORIES Available for both AlarmGard and FireGard Closing Systems A variety of accessories are available to enhance the safety and functionality of a Rolling Fire Door or Counter Shutter. Battery Backup Device The addition of a battery backup device to the fail-safe release device prevents unplanned door closure due to power failure. The device also functions as a backup power source for local warning devices and detectors during power failures. Entrapment Protection Devices To meet the UL 325-2010 standards for safety, doors without a monitored and properly functioning primary entrapment device will only function by constant pressure to close. Wireless Sensing Edge Contact with the edge during the close cycle causes the door to immediately stop downward travel and reverse direction to the fully open position. Photo Eyes Interruption of the safety beam during the close cycle causes the door to immediately stop downward travel and reverse direction to the fully open position. Floor Level Test Stations Safely and conveniently test and reset the functionality of the fire door at floor level. May be flush or recess mounted. Fire Door Annunciators ADA compliant safety devices provide a visual or audible advanced warning when the door is about to close. Can be supported by a battery backup device. Voice Warning Module Horn Strobe Visual strobe warning light powered by the release device. 7

AlarmGard Model ERD10 The Most Advanced and Complete Fire Door Closing System Activated by fire alarm systems or local detectors, this closing system features an integrated release device for an immediate, fail-safe response to a fire event, even in the event of a power failure. AlarmGard Operating System Benefits Compact Design Includes Integrated Fail-Safe Release Device Automatic Reset Plus Automatic Open Eliminates Reset Chain and Crank Operated Spring Tension Not Released Upon Activation Safe, Controlled Activated Closing speed of 9-12" Per Second Minimum Clearance Requirements Motor Operated AlarmGard System These advanced systems close the fire door in response to an alarm signal and are fail-safe by design, safely closing the door during a fire event or prolonged power failure. When the alarm is cleared and power is restored, the door is automatically reset. AlarmGard operators do not require an optional release device. AlarmGard is especially beneficial in recessed applications because there is no need for direct access to the closing system to reset the door. Retrofit Operators The AlarmGard operating system can be retrofit to most manufacturers' fire doors while maintaining the door's listing agency ratings. 8

AlarmGard Tube Motor Operator For Fire Doors and Counter Fire Shutters AlarmGard Tube Motor Operators are concealed in the shaft assembly, making them ideal for openings with tight clearances or when you need to conceal the operator drive components without adding a bulky and unsightly motor cover. The AlarmGard Tube motor operator can be used on Fire Doors or Counter Fire Shutters. Features and Benefits: Convenience of motor operation in a low-profile, concealed design Auto-Reset and selectable Auto-Open Available with or without battery back up UL 325 compliant and UL 864 listed motor assembly Rated for up to 10 cycles per day Electrical connections from the operator to wall-mounted control panel is plug and play Internal fail safe release device and internal centrifugal governor Recommended Applications: Fire Door and Counter Fire Shutters that require convenient motor operation in limited spaces conditions Conditions that will benefit from hidden components and aesthetically pleasing profile Applications requiring a back-up battery to eliminate nuisance activations from power interruptions Chain and Crank AlarmGard Systems Economical Function Even with manual modes of operation, the advanced AlarmGard system includes an integrated fail-safe release device that electrically activates and automatically resets the door. Resetting spring tension or re-engaging the operator is not required. Requirements: An AlarmGard tube motor can operate a fire door or fire counter shutter up to approximately 120 sq ft.* The tube motor requires 115 VAC/60Hz or 230VAC/50Hz** input power and 24Volt alarm input * Size limit varies by door configuration and gauge required. ** Special order - additional lead time will apply. Recommended Applications: Use for fire products that do not require the daily operating convenience of a motor operator. Clearance and access to the hand chain or crank eye is required. 9

FireGard Model ERD10 Save Time and Money on Daily Operation, Testing and Resetting The FireGard s convenient and economical design is thermally activated. This system can be readily drop tested and reset with minimal downtime - dramatically reducing labor and inspection costs. FireGard Operating System Benefits Activates without Releasing Spring Tension Fusible Link Activation Standard Safe, Controlled Closing Speed 9-12" Per Second Will Not Automatically Close Upon Power Failure Compact Design Easy Installation Connection to Alarm System (Optional) Floor Level Test Station (Optional) Motor Operated FireGard System Features and Benefits: Convenience of motor operation Auxiliary chain for emergency operation Simple and inexpensive annual testing Chain and Crank Operated FireGard System Features and Benefits: Power not required Economical Simple and inexpensive annual testing Retrofit Operators The FireGard operating system can be retrofit to most manufacturers' fire doors while maintaining the door's listing agency ratings. 10

A FULL LINE OF ADVANCED FIRE DOOR CLOSING SYSTEMS With quality and reliability as our first priorities, leading functionality and intelligent operation. Visit our website for more information on features, options and finishes available for our rolling fire doors and shutters. A NETWORK OF LOCAL DEALERS TO PROVIDE SUPERIOR SERVICE Whether you want to install a new closure system or are looking to service currently installed products, our Local Dealer Partners are trained and equipped with the tools and resources to ensure your satisfaction. ARCHITECTURAL DESIGN SUPPORT Our experienced Architectural Design Support Team is available to help you customize our products and develop uniquely engineered solutions to fit your specific design needs. MAKE OUR YEARS OF SUCCESS A PART OF YOURS Family owned and run since 1828, our expert design teams and ISO registered state-ofthe-art facilities are focused on providing quality closure solutions that protect lives and property. Contact ADS@cooksondoor.com or call 1.800.294.4358 ext. 1280 for design support. FOR MORE INFORMATION AND TECHNICAL DETAILS, VISIT COOKSONDOOR.COM/FIRE. 11

Your Authorized Cookson Dealer: Cooksondoor.com/fire CornellCookson 6.2017 Preferred door solutions.