(Cabinet Automatic Fire Extinguishing System)

Similar documents
3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

636 and 646 Keypads. User s Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Specification/ Data Sheet

EVO192 v3.0 Fire and Burglary What s New

ELECTRIC FIRE PUMP CONTROLLER

MODEL B2 INSTALLATION MANUAL

EXPERT TRI-STAR. Temperature controller. User s Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

BL Series INSTRUCTIONS

Control Panel User Guide

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

INSTRUCTION MANUAL PC255O

Technical Manual. Level Alarm Unit CARLA & WIDS

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Part 3 Troubleshooting

ion Genesis Pump Controller

INSTRUCTION MANUAL PC255O

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

MANUAL BOOK Sensor faucet

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Fire Command Keypad. XR5 User s Guide

The EN54 Part 2 and 4 Fire System

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

BIG DISPLAY ALARM CLOCK USER MANUAL

USER MANUAL & MAINTENANCE GUIDE OG OO

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

TFD-1 Installation & User s Guide

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Quick Reference Guide

DISPOSER CONTROL CENTER

AFA 500 FUME HOOD ALARMS

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

L900 series USER MANUAL

Auto Dialer. Manual E-921APQ E-921GPQ

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Wireless Keypads LKP(E)S8M Series

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

DISPOSER CONTROL CENTER

DISPOSER CONTROL CENTER

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Alarm Tone Generator Model AG17

NX-148 LCD CODE PAD TABLE OF CONTENTS

AXI LED USER MANUAL (REV. 1.0)

WARNING Important Safety Information

Operating instructions Vigilon panel and Network node Fire detection and alarm system

SC Installation, Operation & Application Guide

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

DAY/TIME Button: Selects hour, minute and day setting.

DC200 Digital Dispenser Operating Manual

User Operation Manual

MANUAL RESET ALARM RELEASE

U S E R M A N U A L UBH1RF HEAT ALARM

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

RELEASE DEVICE CONTROLS

1022 R/T Remote Monitor

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

DEMA 830 Laundry Master TM Installation Instructions

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Installation & Operating Guide

WARNING Important Safety Information

RHMP01 MULTI PURPOSE FAN

Silent Alert Fire Safe System

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

5000 SERIES 8 ZONE INSTRUCTION MANUAL

642 LCD Keypad. User Manual

Installation, Operating and Maintenance Manual

Florida Building Code 2010

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

DISPOSER CONTROL CENTER

Transcription:

(Cabinet Automatic Fire Extinguishing System) For your safety and proper use of this equipment, please read carefully and understand the contents of this manual. Return or keep this manual in its designated place after reading or when not in use. Pre-Engineered Automatic Clean Agent Fire Extinguishing System HFC-227ea HFC-125

Chapter 1 Overview Chapter 2 Characteristics and Specifications 2-1 Characteristics 2-2 Specifications Chapter 3 Control Panel 3-1 Overview 3-2 Essential Electronics 3-3 Control Panel Interface Chapter 4 Installation Methods Chapter 5 Operating Methods 5-1 Automatic Operation 5-2 Manual Operation 5-3 Abort Operation Chapter 6 Inspection & Maintenance 6-1 Inspection 6-2 Maintenance Chapter 7 Special Notice on Maintenance & Service Chapter 8 Troubleshooting Chapter 9 Reference Materials System Diagram of Cabinet Automatic Fire Extinguishing System Detailed Drawing of PCB Electrical Wiring Diagram Installation Methods and Notice Warranty

Chapter 1. Overview This manual describes the proper handling and operating of the Cabinet Automatic Fire Extinguishing System manufactured by Masteco Industry Co., Ltd. Specific instructions for components installation, operation, inspection and maintenance are included. Users are strongly advised to carefully follow these instructions to ensure proper operation and prolong the life of the equipment. Maintenance procedures that require replacement of the PCB components are not illustrated in this manual, please contact nearest authorized agent or Masteco at telephone number 032-811-1301. Applicable Products 1. HFC-227ea Cabinet Automatic Fire Extinguishing System (Low Pressure) 2. HFC-125 Cabinet Automatic Fire Extinguishing System (Low Pressure) Chapter 2. Characteristics and Specifications 2-1. Characteristics 1. Direct installation in the protected area Cabinet Automatic Fire Extinguishing Systems are pre-engineered automatic clean agent fire extinguishing system consists of a set of functional components packed in steel enclosure or cabinet as a single piece or unit of equipment. The unit is directly installed in the protected area therefore, does not require specific agent cylinder storage room. 2. Fast and automatic fire extinguishment Cabinet Automatic Fire Extinguishing Systems are designed to discharge the clean agent in less than 10 seconds. This means that fire is extinguished relatively fast. 3. Applicable for both occupied and non-occupied protected area When installed accordingly in specified size of protected space, the agent concentration is safe for humans - making the Cabinet Automatic Fire Extinguishing Systems suitable for occupied protected areas. 4. Power-loss worry free Cabinet Automatic Fire Extinguishing System are equipped with emergency backup power to ensure proper equipment operation when main power supply is cut off for as long as 60 minutes. 5. State-of the-art control circuit Cabinet Automatic Fire Extinguishing Systems utilize small ultramodern electronic circuit with excellent control functions.

6. Multi-check function The products feature multiple-check functions. Users can easily confirm any trouble in the equipment by reviewing the audible and visual warnings. 7. Operation by smoke and heat detector Cabinet Automatic Fire Extinguishing Systems utilize smoke and heat detectors that are setup in synchronous operation to ensure accurate fire detection. Fire is only confirmed after simultaneous operation of both heat and smoke detectors. If only either one of these detectors activate the detection system is automatically reset after predefined time. 8. Clean The extinguishing agent FM-200 or HFC-125 leaves no residue after discharge and fire extinguishment minimizing time for repair or restoration of protected areas. 2-2 Specifications 1. Specifications of Cabinet Automatic Fire Extinguishing System 1) HFC-227ea System Agent Container Capacity 50 kg 1B/T 75 kg 1B/T 100 kg 1B/T Agent HFC-227ea Model ( 캐 04-4), ( 캐 04-4-1) ( 캐 04-9), ( 캐 04-9-1) ( 캐 04-8), ( 캐 04-8-1) Protected Area (Max. Ceiling Height 3.7 m) 74.16 m 3 111.24 m 3 148.32 m 3 Storage Pressure & Discharge Time 2.48 MPa 10 sec 2.48 MPa 10 sec 2.48 MPa 10 sec Working Temperature -10 C to 40 C Enclosure Size (W D H) 500 x 500 x 1900 mm Enclosure Material KSD3503 1.6t Color Ivory (ED003K) Main Power Supply 220V AC, 60Hz Alarm Siren, Vocal Broadcasting, LED Lamp Gross Weight 190 kg 230 kg 265 kg

2) HFC-125 System Agent Container Capacity 25 kg 1B/T 50 kg 1B/T 75 kg 1B/T 100 kg 1B/T Agent HFC-125 Model 캐 09-11 캐 07-18 캐 07-19 캐 07-9 Protected Area (Max. Ceiling Height 3.7 m) 38.52 m 3 77.05 m 3 115.57 m 3 154.09 m 3` Storage Pressure & Discharge Time 2.48 MPa 10 sec 2.48 MPa 10 sec 2.48 MPa 10 sec 2.48 MPa 10 sec Working Temperature -10 C to 40 C Enclosure Size (W D H) 500 x 500 x 1900 mm Enclosure Material KSD3503 1.6t Color Main Power Supply Alarm Ivory (ED003K) 220V AC, 60Hz Siren, Vocal Broadcasting, LED Lamp Gross Weight 165 kg 190 kg 230 kg 265 kg

Chapter 3 Control Panel 3-1 Overview The Control Panel is built in the cabinet or enclosure. It electronically controls the functions of the entire Cabinet Automatic Fire Extinguishing System which include confirmation of fire detection, actuation for agent discharge and activation of alarms. It consists of electronic control circuits, switch, fuse, etc. and embedded with control program carefully designed for reliable and safe system operation. 3-2 Essential Electronics 3-2.1 Power Circuit Main electrical power to the Cabinet Automatic Fire Extinguishing System is supplied at the conventional rating of 220V AC, 60Hz. The power circuit is equipped with suitable transformers and other electrical devices that enable conversion of current and supply of 24V DC to the Control Panel while also charging the batteries for back-up power supply. - Power normal condition: At normal condition, the Control Panel is supplied with electrical power from the main electrical power source i.e. AC source at the same charging the batteries if necessary. - Power cut-off condition: When power is cut-off, the batteries automatically supply the electrical power to the Control Panel. When fully charged, batteries are capable of supplying the needed power for about 60 minutes. When the main power is restored, the system automatically switch to power normal condition as pointed out above. 3-2.2 Vocal Broadcasting The Cabinet Automatic Fire Extinguishing System are equipped with Vocal Broadcasting system that produces programmed voice announcement through the speaker in case of fire and general instructions for safe escape. The speaker is fitted with volume controller that is used to adjust voice level. The amplifier output is 10 W with the speaker impedance of 8 Ω. Prior to Vocal Broadcasting siren alarm is sounded that lasts for 10 seconds. The following are the sequence of alarms produced by the fire extinguishing system in the event of fire. 1. Alarm Sound for Escape: Siren alarm for 10 seconds. 2. Vocal Broadcasting for Escape: Vocal instructions for fire escape that is computer preprogrammed within the integrated circuits.

3-2.3 Detection Circuit In the event of fire, electrical signal from the detectors located in a protected flows through the detection circuit and into the control panel. Control panel then activates the fire signal lamp and emergency vocal broadcasting. 3-2.4 Discharge Circuit As the electrical signal from the detectors is received by the control panel, the solenoid cutter is also activated. The solenoid cutter then actuates the agent container valve allowing the discharge of fire extinguishing agent. The extinguishing agent pressure actuates the pressure switch which signals the control panel of the agent discharge. The control panel in turn activates the LED lamp to indicate that the agent is being discharged. The electronic connection of the control panel, solenoid cutter, pressure switch and LED lamp forms the discharge circuit. 3-2.5 Cut-out circuit This cut-out circuit is used to constantly monitor the connectivity of the electric wires of detectors, solenoid valve, discharge lamps and manual control box. Trouble in the electrical line or some abnormal status can be confirmed by the alarm sound (cricket sound) with the green lamp on.

3-3 Control Panel Interface The control panel interface provides a means for operating, testing and monitoring the status of the Cabinet Automatic Fire Extinguishing System. Operating commands can be input to the control panel via the button switches while system status can be verified via the LED lamps. Button switches and LED lamps are labeled accordingly. The function of each button and lamp is described in this section. No Display Part Name 1 Speaker 2 Power Lamp 3 Aux Power Lamp 4 Aux Power Trouble Lamp 5 Fire Lamp 6 Circuit Trouble Lamp 7 Actuator Lamp 8 Discharge Lamp 9 Manual Actuating Lamp 10 Detector 1 Lamp 11 Detector 2 Lamp 12 Voltmeter 13 Battery Check Switch 14 Sound ON/OFF Switch 15 Actuator Stop Switch 16 Reset Switch 17 Detector Test Switch 18 19 Detector 1 Test Switch(L1+,-) Detector 1 Test Switch(L2+,-) 20 Operating Auto mode 21 Operating Manual mode 22 Mode Select Switch 23 Manual Actuating Switch

NO Lamp/Switch Description 1 Speaker Used to produce vocal broadcasting. The output is 10W, and the impedance is 8 Ω. 2 Power Light on confirms the AC power supply. 3 Battery Turns on when main electrical power supply is cut-off or back-up/auxiliary power is active. 4 Monitor of Battery Indicates abnormal status of low battery charging, cut-off fuse, or inferior connecting wire, and battery recharging. 5 Fire When the detector installed in the protected area and manual station is on operation, this lamp will be on, and it is also on during system simulation. 6 Line Disconnected Turns on in case of abnormal status of the detector 1 and/or detector 2. 7 Operating Device Red lamp on when solenoid cutter is operated 8 Gas Discharge Red lamp on when the gas is being discharged. Stays on until system reset. 9 Manual Actuation For system manual actuation, crush/break the acrylic plate cover and push the switch. 10 Detector 1 Red lamp turns on if the Detector 1 installed in the protection area is operated. 11 Detector 2 Red lamp turns on if the Detector 2 installed in the protection area is operated. 12 Voltage Real-time display of actual DC power supply voltage to the control panel ranging from 19V to 29V. 13 Battery Test Press this switch to test battery operation. If switched on, power supply will be switched to battery and Battery lamp will turn on. 14 Sound ON/OFF Press this switch to stop any of the trouble, siren or voice alarms.

15 Abort Discharge If pressed will disable DC power supply to solenoid cutter rendering the solenoid cutter electrically inoperable. 16 Reset Press this switch to reset all functions to normal. 17 Detector Test Press this switch to manually activate the detector during simulation of system operation in case of fire. 18 Detector 1 During fire simulation, press this switch to manually activate Detector 1. 19 Detector 2 During fire simulation, press this switch to manually activate Detector 2. 20 Auto Mode Set the system in automatic mode. 21 Manual Mode Set the system in manual mode. 9

Chapter 4 Installation Methods 1. Install the cabinet (fire extinguishing system) in a suitable location where the agent can be distributed uniformly throughout the protected area during discharge. An optimum location can be the farthest and obstruction-free point in the protected area. 2. Fire Extinguishing Agent Container Fixtures As delivered, verify that the Extinguishing Agent Container is fixed to the steel cabinet using the provided steel band. The flexible hose is also mounted to the container. 3. Pressure Switch Connection The pressure switch is actuated by the pressure from the agent during discharge. It shall be appropriately connected to the unit through the flexible hose using copper tube and fittings. 4. Connecting the Solenoid Cutter Solenoid Cutter is used to open the agent container valve to enable the discharge of agent. Ensure that the safety pin is secured with the needle head and the safety clip is properly mounted to the push button. Install the Solenoid cutter to the top of the container valve by tightening the nut adapter. Connect the wire terminals accordingly. Refer to the Installation Method and Suggestions for more details. 5. External Devices Wiring Connection Electrical devices not built-in with the cabinet must be properly connected to the unit. Connect all detectors, manual station, discharge lamp, and speaker wiring to the control panel of the Cabinet Automatic Fire Extinguishing System in accordance with the corresponding wiring diagrams attached to the control CAUTION: It is highly recommended that manufacturer s suggested devices be used. If other devices are used, make sure that they are compatible with the Control Panel 6. System Integration with Other Facilities After making the necessary connections with the Cabinet Type Auto-Fire Extinguishing System, if applicable, the unit can be connected to other facilities such air-conditioning system, ventilation system, security system, etc. 7. System Function Verification Test all functions of the Cabinet Automatic Fire Extinguishing System. Execute corrective measures of any functional issue is found. 10

Chapter 5 Operating Methods 5-1 Automatic Operation The Cabinet Automatic Fire Extinguishing System automatically operates via the detectors. In case of fire, the detectors are activated sending electrical signal to the Control Panel. The Control Panel activates the fire alarms (audible and visual) systematically and at the same actuates the Solenoid Cutter to open the agent container valve. As the agent is discharged through the flexible tube, part of it flows into the copper tube connected to the pressure switch. The pressure from the discharged agent actuates the switch and electrical signal is sent to the Control Panel to activate the discharge alarm lamp while rest of the fire extinguishing agent is discharged to the protected area through the discharge head that is exposed over the top of the cabinet. 5-2 Manual Operation Manual agent discharge operation of the Cabinet Automatic Fire Extinguishing System can be initiated from inside or outside the protected area (room). 5-2.1 Operation from Inside the Protected Area 5-2.1.1 Operation Using the Manual Actuation Button To manually operate the unit for agent discharge, proceed to the control panel interface and find the Manual Actuation button. Crush/Break the acrylic plate cover of the of Manual Actuation button then press the button. 5-2.1.2 Operation Using the Solenoid Cutter To manually operate the unit for agent discharge, open the cabinet door and find the Solenoid Cutter. Pull-off the safety clip from the Solenoid Cutter and press the Push button. 5-2.2. Operation from Outside the Protected Area To manually operate the unit for agent discharge from outside the protected area, proceed to the Manual Station located by the room door. Open the Manual Station cover, break/crush the safety protection panel and press the button.

5-3 Abort Operation In an unlikely case of faulty operation of the detectors and/or false fire alarm, the system operation can be aborted to prevent agent discharge. To totally abort the agent discharge operation, proceed to the Control Panel interface located at the front of cabinet. Press the Abort Gas Discharge button Alternatively, the system operation can be temporarily aborted via the Abort Switch if installed with the system to hold and/or delay agent discharge. To execute the system abort, proceed to the Abort Switch located by the door outside the protected room. Press and continuously hold down the button to abort system operation. Abort is only active while the button is being held down. Upon release of the Abort Switch, the agent discharge sequence will be re-initiated and the agent will be discharged within 30 seconds. The abort/delay is normally utilized in case of emergency where protected area occupants are being evacuated out of the protected area prior to agent discharge.

Chapter 6 Inspection & Maintenance 6-1 Inspection 1. Daily Inspection Daily inspection should be carried out to cover the following activities. Confirm the Auto-Manual Mode switching operation. Confirm the status of lamps. Confirm the status of switches. Confirm the power voltage of digital voltmeter. Confirm the agent storage status of the agent container. Confirm the transformation and corrosion of external shape. Confirm that the space in front of cabinet is free of any possible obstruction of agent discharge. Confirm the auxiliary battery power. 2. Quarterly Inspection The quarterly inspection is carried out once every other three months. This should be inspected by the firefighting engineer, qualified fire manager, or expert of the Cabinet Type Auto-Fire Extinguisher. Confirm installed position or status of the fire extinguisher. Confirm the damage or corrosion of the component of the unit. Confirm the position of component, and any modification of fixed parts. Confirm the status of solenoid cutter and safety clip and sealing conditions of the unit. Confirm the electrical wiring terminals are properly connected. Confirm that cylinder shows no sign of agent leakage or loss of pressure. Confirm the status of the power supply. Confirm the operating status of the solenoid cutter. Inspect and confirm all functions of the control system. 6-2 Maintenance Maintenance should be performed by firefighting engineers in accordance to instructions of the expert of Cabinet Type Auto-Fire Extinguishing System. Contact the manufacturer for any difficulty or issues related to the product.

Chapter 7 Special Notice on Maintenance & Service 1. As the AC power should be connected at all times (for 24 hours), the users should confirm that electrical power is continuously supplied. 2. Users should always check the battery charging operation. The battery will not recharge after it has been drained or discharged to 8V or below. In such case, the battery must be replaced. 3. The Solenoid Cutter is equipped with slender needle having sharp tip. Take precaution in handling to avoid personal injury. Handle the device with care, avoid external shock and always excessive humidity. 4. When resetting the Solenoid Cutter after the inspection, the users should pay close attention not to damage the needle. (Refer to the Installation Method and Special Notice.)

Chapter 8 Troubleshooting When installing or operating this unit, if any abnormal operation occurs, please take necessary action according to this troubleshooting guide. If the troubleshooting solution herein does not solve the problem, contact MASTECO at telephone number 032-811-1301. Trouble Cause Solution When the POWER lamp turns off When BATTERY lamp is on. When MONITOR OF BATTERY lamp is on. When the FIRE lamp is on *Inferior inlet power line. *The power switch is off. *Abnormal AC fuse. *Inferior AC LED Lamp. *AC power is off. *The power switch is off. *Abnormal AC fuse. *DC power is off, but battery is on. *Inferior battery charging or fuse is cut-off. *In case of detector 1 is operating. *In case of detector 2 is operating. *In case of manual starter is operating. *Confirm the input line. *Confirm On-Off switch. *Change the fuse when the fuse is cut-off. *Change LED. *Confirm the power connection and the power supply. *Powerswitch should be on. *Change the fuse when the fuse is cut-off. *AC switch should be on. *Battery should be connected and the fuse should be changed or battery should be changed. *Inspect the detector 1 and if it is misoperated, please reset it. *Inspect the detector 2 and if it is misoperated, please reset it. *When operated by manual starter, as the agent is discharged within 30 seconds, in case of no fire, push the discharge stop switch, and reset it after investigating the cause. When DETECTOR 1, DETECTOR 2 lamps are on. * In case of DETECTOR 1, DETECTOR 2 is cut-off. *Terminal is disconnected from the register *Trouble relay fail by the faulty wiring. *Reset the cut-off wiring. *Connect the terminal register. *Change the trouble relay.

Trouble Cause Solution Lighting status of LINE DISCONNECTED lamp. DETECTOR 1 is cut-off. DETECTOR 2 is cut-off. Trouble relay is disordered by the faulty wire connection. Restore the cut-off line. Make out the terminal register. Change the trouble relay. No fire, alarms sound *Manual box door is open Close the door of the manual box. No voltage signal at the VOLTAGE (the signal : DC24 is correct, but 00:0 is not normal) Troublesome of regulator IC. Electrical shock and damage Change the regulator IC. Change the 4051MUX IC.

Trouble Cause Solution If the warning sound is too low or too loud. In case of adjusting the delay time of Solenoid Cutter operation. Adjust the volume of warning sound. *Adjust the time delay. *There is volume control at the center of the board equipped to the top end. Adjust volume accordingly. Clockwise : - (Decrease) Counter-clockwise : + (Increase) *The volume equipped to the board of the lower end is adjusted. Clockwise : - Counter-clockwise : + Detailed Dwg of PCB In case of adjusting the delay time of solenoid cutter operation. If the warning sound is too low or too loud.

Installation Method and Safety Notes A. Drawing Clean Agent Container B. Safety Pin Position While On System Setup C. Reset Method After System Operation Bottom Should be fixed with anchor bolts 1. The extinguishing agent container should be installed in suitable location such that the discharged agent is equally distributed in the protected area. 2. The cabinet should be installed indoor on level floor and away from any flammables. The rear side should evenly rest against the wall and the bottom fixed to the floor by anchor bolts. 3. Remove possible obstacles from the discharge head located on top of the cabinet. 4. The flexible hose should be assembled to the container valve according to the installation drawing. 5. Ensure that the extinguishing agent container is securely fastened to the cabinet by bands and bolts. 6. Note that the safety pin must be removed from the needle head to ensure solenoid cutter actuation. Failure to remove the safety pin may result to system inability to discharge agent even during fire. 7. Operator of the equipment MUST read the manual for other details. Bottom Should be fixed with anchor bolts

Warranty Period Model No./Product Description : Date of Purchase : Buyer Information (Name/Company) : Address : Sales Agent/Representative : Address : Phone : LIMITED WARRANTY SHEET : 1 year from the date of purchase GENERAL POLICY: All Cabinet Automatic Fire Extinguishing System products are inspected and approved by Korea Fire Institute; Masteco Industry Co., Ltd., the manufacturer based in Incheon, Korea provides a limited warranty against defects in material and workmanship on all Cabinet Automatic Fire Extinguishing System components; One (1)-year warranty is limited the following options (to be decided by manufacturer): (a) Replacement or free-of-charge repair of defective components; (b) Refund of purchase price for such components paid by buyer; Buyer to pay transportation-related fees incurred from sending to manufacturer or service center any component for repair and receiving the repaired or replacement component; The buyer has the right to enforce such warranties; On-site inspection or repair services rendered after expiration of 1-year warranty are subject to appropriate charges. WARRANTY SHALL NOT APPLY WHEN: Product has been subjected to neglect, misuse, abuse or damage; Product has been installed or operated other than in accordance with the instructions in this manual; Repair or reassemble was done by party/parties other than authorized servicemen; Product has been damaged due to natural calamity, fire, flood disaster; Warranty Sheet is not provided when requested. To make warranty claim contact: MASTECO INDUSTRY CO., LTD. Head Office: 1101ho, Beotkkot-ro, Geumcheon-gu Seoul, 153-788, Korea Tel.: 02-785-1301, Fax: 02-785-1313 Service Center: (146BL-13LT) 715-12, Gojan-dong, Namdong-gu Incheon, 405-821, Korea Tel.: 032-811-1301 Fax: 032-811-1305

This product is inspected and approved by the Korea Fire Institute. Within 1 year from the date of procurement, this product can be after serviced (A/S). After 1 year of warranty period, this product can be after serviced at suitable cost. This warranty sheet shall be presented when requested during after service Head Office : Richensia B-304, 61, Yeoido-Dong, Youngdongpo-Ku, Seoul, Korea. Tel : 82-02-785-1301, Fax : 82-02-785-1313 A/S Center : (146BL-13LT) 715-12, Gojan-Dong, Namdong-Ku, Inchon, Korea Tel : 82-032-811-1301 Fax : 82-032-811-1305