STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Similar documents
Instruction Manual Model L2 RF Switch

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM HISTORY ALARM RESET

IF-L/RF Protection Switch

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Instruction Manual Model Backup Switch, 1 for 8

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Model 4001 Series Single Channel Controller

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

GAS MONITOR Model Model

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

6502B RF Distribution

Alarm Tone Generator Model AG17

DataPoint Continuous Relay Controller LC52 Series Manual

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Beacon 800 Gas Monitor Operator s Manual

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

4 & 8-POINT ANNUNCIATORS Instruction Manual

Installation Instructions

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MODEL 5100 VOTING LOGIC MODULE

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Door Release Power Supply

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

SA VOLT SIREN AMPLIFIER

ACCURATE ELECTRONICS INC

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

INSTALLATION AND INSTRUCTION MANUAL

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

Protocol Station Remote Alarm

21-light Remote Annunciator. Owner s Manual

Continuous Relay Controller LC52 Series Owner s Manual

Beacon 410A Gas Monitor Operator s Manual

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

SC-6 Six Supervised Control Module

QMF MAINFRAME Installation Manual

VMD-2008 Operation Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Expanded Backup Control Installation & Operator s Instruction Manual

INTRODUCTION / TABLE OF CONTENTS

Installation and Operation Manual

Booster Power Supply Manual

Model T B Intraoffice T1 Repeater User Manual

Single Station Remote Alarm

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

SA SIREN AMPLIFIER

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

Pump-Up Controller MODEL 4062

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

RATIO:GUARD. MODEL P-1 ph INDICATOR/CONTROLLER GETTING TECHNICAL ASSISTANCE

INTRODUCTION / TABLE OF CONTENTS

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Global Water Instrumentation, Inc.

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

Installation and Operating Instructions

Pump-Down Controller MODEL 4052

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

Model A1600 Series Annunciator

Model AD C AD RS-422 Distributor

Instruction Manual WARNING

CT2 Retro Box Installation Instruction Manual

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Rack Mount Series Installation Guide

Installation and Operation Manual Low Power (LP) DC Power System

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Controllers. Instruction Manual WARNING

RATIO:GUARD Model E-1S EC Monitor

ion Genesis Pump Controller

Environmental Monitoring SmartSlot Card

CZ-6A Six Zone Interface Module

Smart Series TAS-05-11, TAS-05-12

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Panel Mounted Heat Exchangers by Dantherm, Inc.

ESP TECHNOLOGIES LIMITED

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Model OEM-2 INSTRUCTIONS FOR USE

Transcription:

Instruction Manual Model 1582-152 RF Protection Switch November 2009, Rev B. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE RESET ALARM ALARM HISTORY HISTORY RESET POWER Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 1582-152 RF Protection Switch TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 2.0 Installation 5 2.1 Mechanical 5 2.2 Input and Output Signals 6 2.3 Controls and Indicators 7 2.4 Operation 9 2.5 Switch Mode Setup 10 3.0 Environmental Use Information 11 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com 1582-152 Manual, Rev. A Page 2 11/05/09

MODEL 1582-152 RF Protection Switch 1.0 General 1.1 Equipment Description The 1582-152 IF/RF Protection Switch provides Auto, Manual or Remote relay switching between CH1 and CH2 for both IF/L-Band signals (DC to 2.5 GHz) and RF signals (DC to 15 GHz.) Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable). The logic controls two separate RF and IF/L-Band switches, A and B, respectively. Switching logic can be selected as follows: 1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back when CH1 is no longer in alarm or both CH1 and CH2 are bad. 2. Latch to CH2 Mode - Switches to CH2 if CH1 alarms and CH2 is good. Latches to CH2. Push Manual Reset or ground Remote Reset pin to return to CH1 if it has no alarm. 3. Minimum AUTO switching, Initial Channel Select (ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO. AUTO switching occurs only if current channel alarms and other channel is clear. When power is lost, CH1 is selected. The Manual Select switch and (when in AUTO) contact closures to Remote Select pins select CH1 or CH2 independent of alarms. LEDs indicate alarm and switch conditions for CH1 and CH2 and REMOTE or MANUAL operation. The 1582-152 is housed in a 1RU x 12 deep chassis, and is powered by two redundant power supplies. CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE RESET ALARM ALARM HISTORY HISTORY RESET POWER FRONT PANEL AC1 AC2 GND B1 B B2 A1 A A2 J4 J5 J6 1 J7 14 J8 J9 J10 REAR PANEL FIGURE 1.1 Model 1582-152 Front and Rear Panels SWITCH B SWITCHED IF/L-BAND SWITCH A SWITCHED RF SWITCH B IF/L-BAND 2 SWITCH B IF-L-BAND 1 SWITCH A RF 2 SWITCH A RF 1 CH 1 AUTO CH 2 REMMAN 1 2 MON CONTROL LOGIC 1 2 ALM 1 2 REM REM RESE SWITCH RESET FIGURE 1.2 Model 1582-152 RF Switch Block Diagrams 1582-152 Manual, Rev. A Page 3 11/05/09

1.2 Technical Characteristics TABLE 1.1 1582-152 RF Switch Specifications* IF/L-Band Switch (Switch B) Characteristics Impedance/Connectors 75Ω / BNC Return Loss >12 db DC to 1.5 GHz >10 db to 2.5 GHz Frequency Response ±0.5 db, any 40 MHz BW, DC to 2.5 GHz Isolation 55 db min, > 60 db typ, DC to 1.5 GHz 45 db min, > 50 db typ, to 2.5 GHz Switch time 10 milliseconds Insertion Loss 1.5 db max, 1.0 db typ, DC to 1.5 GHz 2.5 db max, 2.0 db typ, to 2.5 GHz Type Relay Configuration SPDT RF Switch (Switch A) Characteristics Impedance/Connectors Return Loss Isolation Switch time Insertion Loss 50Ω / SMA > 18 db, DC to 4 GHz > 15 db, to 8 GHz > 12 db, to 15 GHz > 70 db, DC to 4 GHz > 60 db, to 8 GHz; 10 milliseconds 1 db, DC to 4.0 GHz 1.5 db, to 8 GHz 2.0 db, to 15 GHz Type Relay Configuration SPDT, no termination Other Alarm/Remote Conn. Terminal Strip Power Redundant power supplies; 100-240 ±10% VAC, 47-63 Hz, 30 watts Controls MANUAL SELECT Manually select CH1 or CH2 SWITCH RESET Resets to CH1 in latch mode, and resets REMOTE HISTORY RESET Resets alarm history (prior occurrence of alarms now cleared) - LEDs only Indicator LEDs CH1 ON-LINE Turns green when Channel 1 is selected CH2 ON-LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2. ALARM CH1 Turns red when Channel 1 alarm input is a closure or open (selectable) ALARM CH2 Turns red when Channel 2 alarm input is a closure or open (selectable) ALARM HISTORY 1 Turns red on Channel 1 alarm and stays red until HISTORY RESET is pushed ALARM HISTORY 2 Turns red on Channel 2 alarm and stays red until HISTORY RESET is pushed POWER CH1 Turns green when power is applied to AC1 input on the rear panel POWER CH2 Turns green when power is applied to AC2 input on the rear panel REMOTE Turns amber when REMOTE control is active MANUAL SELECT Manually select CH1 or CH2 *+10 C to +40 C; 2000m max elevation; 80% max humidity; Specifications subject to change without notice. 1582-152 Manual, Rev. A Page 4 11/05/09

2.0 Installation 2.1 Mechanical The 1582-152 consists of one RF/Controller PCB and one IF piggyback PCB housed in a 1 RU (1 3 4 inch high) by 12 inch deep chassis. Redundant switching power supplies provide power for the assembly. The 1582-152 can be secured to a rack using the 4 holes on the front panel. JP2 POWER SUPPLY 2 JP1 JP3 POWER SUPPLY 1 JP4 JP1, JP2, JP3, JP4, AND S4 POSITIONS SHOWN ICS AND LATCHED MODE 1 2 3 4 ROCKER DOWN S4 - ROCKER SWITCH DETAIL SHOWN WITH ALL SWITCH POSITIONS IN THE ON SIDE O F F FIGURE 2.1 1582-152 RF Switch Assembly 1582-152 Manual, Rev. A Page 5 11/05/09

2.2 Input and Output Signals Figure 2.2 shows the input and output connectors on the rear panel. AC1 - POWER IN 1 AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. AC2 - POWER IN 2 AC input for switching power supply. 90-260 VAC, 47-60 Hz. J4 - IF INPUT B1 SWITCH 1 IF input. BNC (female), 75 Ω. J5 - IF OUTPUT B (COMMON) SWITCH COMMON IF output. BNC (female), 75 Ω. J6 - IF INPUT B2 SWITCH 2 IF input. BNC (female), 75 Ω. AC1 AC2 B1 B B2 GND J4 J5 J6 A1 A A2 1 J7 14 J8 J9 J10 J7 - MONITORS and CONTROLS Terminal Strip. See Table 2.1. J8 - RF INPUT A1 SWITCH 1 RF input. SMA (female), 50 Ω. J9 - RF OUTPUT A (COMMON) SWITCH COMMON RF output. SMA (female), 50 Ω. J10 - RF INPUT A2 SWITCH 2 RF input. SMA (female), 50 Ω. FIGURE 2.2 1582-152 RF Switch Rear Panel Inputs/Outputs Table 2.1 J7 Pinouts (Monitors and Controls) Pin Function Description 1 REMOTE 1 IN When in AUTO, momentary ground on this pin selects CH1 2 REMOTE 2 IN When in AUTO, momentary ground on this pin selects CH2 3 GROUND Ground 4 REMOTE RESET IN When in LATCH mode, ground resets switch to CH1 5 NC Not Connected 6 SWITCH COMMON Common pin for SWITCH 1, 2 7 GROUND Ground 8 MANUAL *Open collector output (< 5Ω) to GND when in MANUAL mode 9 REMOTE *Open collector (< 5Ω) to GND when in REMOTE mode 10 GROUND Ground 11 SWITCH 1 **Relay closure to J7 pin 6 (<5Ω) when CH1 RF is selected 12 SWITCH 2 **Relay closure to J7 pin 6 (<5Ω) when CH2 RF is selected 13 ALARM 1 IN Ground or Open (selectable by JP2) is CH1 alarm 14 ALARM 2 IN Ground or Open (selectable by JP2) is CH2 alarm * Max voltage to be connected is +20 VDC @ 30mA ** Max voltage to be connected is +30 VDC @ 100mA *NOTE* When the 1582 RF Switch is installed into a system, J7 Pins 13 and 14 (Alarms In) and appropriate grounds must be interconnected between the primary(s), backup(s) and the 1582 RF Switch for proper switch function. 1582-152 Manual, Rev. A Page 6 11/05/09

2.3 Controls and Indicators Figure 2.3 shows the front panel controls and indicators. S3 - MANUAL SELECT 3-position switch manually selects CH1 or CH2 or puts the unit in AUTO mode (switch position determined by Alarm and Remote closures). S1 - SWITCH RESET Push-button resets switch to CH1 if it is good and switch is in LATCH mode. Also resets REMOTE selection to normal AUTO operation. S2 - HISTORY RESET Push-button resets ALARM HISTORY LEDs only. DS9,DS10 - POWER LEDs Light green when power is applied to AC1, AC2. SWITCH STATUS CH1 AUTO CH2 1 2 1 2 1 2 CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE RESET ALARM ALARM HISTORY HISTORY RESET POWER DS6 - CH1 ONLINE LED Lights green when CH1 is selected. DS5 - CH2 ONLINE LED Lights green when CH2 is selected. DS3 - MANUAL LED DS4 - REMOTE LED Lights red when CH1 or Lights yellow when CH2 is manually remote control is active. selected (using S3). DS8,DS7 - ALARM LEDs Light red when CH1 or CH2 alarm input is a closure or open (selectable). DS1,DS2 - ALM HIST LEDs Light red on CH1,CH2 alarm, and stay red until HISTORY RESET is pressed. FIGURE 2.3 1582-152 Front Panel Controls and Indicators 1582-152 Manual, Rev. A Page 7 11/05/09

2.3.1 PC Board Settings NOTE: Dot position means jumper goes from pins 1-2; non-dot means jumper goes from pins 2-3 JP1-3-pin jumper - 3-pin jumper that works with JP3 In the dotted position when CH1 alarms the 1582-152 will switch to CH2 until CH2 alarms. At this point, if CH1 is still in alarm, the switch will stay on CH2. When the CH1 alarm clears if CH2 is still in alarm, the switch will switch to CH1. JP1 normal position - dot (operates in conjunction with JP3 as noted below) JP2 - Input Alarm Condition 3-pin jumper In the dotted position open is normal, ground is alarm In the non-dot position ground is normal, open is an alarm. JP2 normal position - dot JP3 - LATCH to CH2 mode ON / OFF - 3-pin jumper effective when JP1 is in the non-dot position. With JP3 in the dot and JP1 in the non-dot, when channel 1 alarms, the 1582-152 switch switches to channel 2 and stays there until the reset button is pushed on the front panel or by an external closure to ground on the remote RESET pin on J7, and then it switches to channel 1. (If channel 1 alarms are cleared ). If in the ICS mode and originally set to CH2 the 1582-152 will not switch if CH2 alarms. Only the RESET functions (front panel pushbutton or J7 closure to ground) will return the switch to CH1. With JP3 in the non-dot and JP1 in the non-dot, when channel 1 alarms the 1582-152 switches to channel 2 until the alarm on channel 1 clears and then the 1582-152 switches back to channel 1 automatically. JP3 normal position - dot JP4 - CH2 Alarm Enable / Ignore - 3-pin jumper Dotted position - Failure in CH1 will cause a switch to CH2 even if CH2 is in alarm. LEDs will correctly show CH2 alarm status. Non-dotted position - Failure in CH1 will cause a switch to CH2 only if CH2 is not in alarm. JP4 normal position - non-dot S4 - Initial Channel Select (ICS) Mode - 4-position DIP switch Selects the Initial Channel Select mode when JP1, JP2, JP3 in Dot and JP4 in Non-dot. S4 positions 1,2,3,4 to ON - ICS enabled. In the ICS mode, the initial channel can be either CH1 or CH2 by switching the front panel MANUAL SELECT switch to either CH1 or CH2 and then back to the AUTO position or by grounding either REMOTE 1 or REMOTE 2 pins on J7 and then grounding the REMOTE RESET pin on J7 causing the 1582-152 to go back to AUTO in the channel last selected remotely if both channel alarms are clear or both channels are in alarm. The initial channel can also be selected if both channel alarms are clear or both channels are in alarm. S4 positions 1,2,3,4 to OFF - ICS disabled (Minimum Auto switching, Return to Last State Mode) The 1582-152 goes to the last state (CH1 or CH2) it was in when in AUTO after manually or remotely switching and returning to AUTO. Auto switching occurs only if current channel alarms and the other channel is clear. S4 normal position - 1,2,3,4 to ON 1582-152 Manual, Rev. A Page 8 11/05/09

2.4 Operation 1. Set the on board controls as desired (Tables 2.2, 2.3, Figure 2.3). 2. Install the 1582-152 in the equipment rack. 3. Connect RF to the SMA connectors (J1,J2,J3). 4. Connect to signals on the MONITORS AND CONTROLS connector, J7, as desired (see Figure 2.2, Table 2.1). 5. Connect power via two power cords to AC1 and AC2. 6. Manually switch between channels 1 and 2 and be sure switching occurs. 7. Switch to AUTO. Alarm channel 1 and note that automatic switching occurs. Remove alarm to CH1 and note that the output switches as desired. Push RESET if in LATCH mode. Repeat for CH2. 8. Check that CH1 and CH2 are selected when in AUTO and momentary ground is applied to J7 pins 1 and 2. Momentarily ground Remote Reset pin 4 on J7 if in LATCH mode to return to AUTO operation. FUSE DRAWER SPARE FUSE AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.4 Fuse and Spare Fuse Locations 1582-152 Manual, Rev. A Page 9 11/05/09

2.5 Switch Mode Setup The following gives the switch mode settings of the on board controls that can be changed in the field with JP1, JP2, JP3, JP4; S4. ( Figure 2.3). All shown with external alarm = ground. 1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm Non-dot JP1, JP3, JP4; Dot - JP2; S4 - ALL TO OFF. 2. Latch to CH2 Mode - Switches from CH1 to CH2 if CH1 alarms and CH2 is good. Latches to CH2. Push Reset or ground Remote Reset pin to return to CH1 if it has no alarm or both CH1 and CH2 are in alarm. Non-dot - JP1, JP4; Dot - JP2, JP3; S4 - ALL TO OFF. 3. Minimum Auto switching, Initial Channel Select (ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO if both channel alarms are clear or both channels are in alarm. Auto switching occurs only if current channel alarms and the other channel is clear. Non-dot - JP4; Dot - JP1, JP2, JP3; S4 - ALL TO ON. Factory set mode is generally 1) CH1 Prime Mode. 1582-152 Manual, Rev. A Page 10 11/05/09

3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1582-152 Manual, Rev. A Page 11 11/05/09

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 1582-152 Manual, Rev. A Page 12 11/05/09