Infrared Flame Detectors

Similar documents
Infrared Flame Detectors

RAR... Photocell Detectors. Building Technologies Division

QRA10... QRA53... QRA55...

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

Blue-flame Detectors

QRA10... QRA53... QRA55...

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

Flame Safeguards LFE10. Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

LAE10 LFE10. Use. Series 02

UV Flame Supervision System

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies Division

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Heating Element. Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Basic unit with integrated air-fuel ratio control for forced draft burners

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

UV - flame detector dual fuel burners for intermittent burner operations

Section 1 Overview. Introduction 1-1

LME75... Burner controls. Building Technologies

Product Range Overview

FIREYE C9707A ALL FUEL SCANNER

Burner Management System

Burner controls. Building Technologies HVAC Products

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Use. The burner controls are certified to EN 230 and EN 298.

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Power Flame Incorporated

Burner Controls. Building Technologies HVAC Products

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

LFL Series Burner Flame Safeguard Control

Program module for burner control LME71.000

RS /E-EV C01 SERIES

RS /E-EV C01 SERIES

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Forced draught gas burner

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LOW NOx MODULATING GAS BURNERS

Gas Burner Controls. Building Technologies HVAC Products

COMPACT FLAME CONTROLLER CFC 2000

Burner Management System

COMPACT FLAME CONTROLLER CFC 1000

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

EUROFLAT SERIES TYPES C... S... M...

EUROBOX SERIES TYPES CM... SM... MM...

for relative humidity and temperature

Burner Management System

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

MMG Gas burner safety control

COMPACT FLAME CONTROLLER CFC 100

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

RIELLO 40 GS/M SERIES

MMI (40-34) Gas burner safty control

Building Technologies Division

Control Products & Systems OEM

Fireye FLAME SCANNERS

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Distributed By: M&M Control Service, INC

Gas burner automatic safety control MMI / 811.1

Chemical Processes in the Combustion

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

EUROBOX SERIES TYPES CM...N SM...N MM...N

MICROFLAT SERIES TYPES C.../U T X

Rules for Classification and Construction Additional Rules and Guidelines

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

MBCE-110/230UV Flame Sensor Module

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

for relative humidity and temperature

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Talentum - Why use our Flame Detectors?

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Transcription:

7 719 Infrared Flame Detectors QRI... Infrared flame detectors for use with Siemens burner controls, for the supervision of gas, oil and other flames that emit infrared light. The QRI... are suited for burners of any capacity, either in continuous or intermittent operation. The QRI... and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products. Use, features Key features of the QRI... flame detectors: - Detector with infrared-sensitive flame detecting element - Integrated flame signal amplifier - Designed for frontal and lateral (90 ) illumination - Suited for use with burner controls type LMV5... - Secured to the burner with flange and clamp The spectral sensitivity of the QRI... is a maximum of about 2 µm covering infrared radiation emitted by gas, oil, and coal flames as well as other sources of infrared light. Owing to electronic self-supervision of the flame signal, the QRI... can be used in connection with suitable burner controls designed for burners in continuous or intermittent operation. The sensitivity of the QRI... is such that it must be fitted behind the burner s baffle plate.

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the flame detector! All activities (mounting, installation and service work etc.) must be performed by qualified staff. If not observed, there is a risk of impairment of safety functions and of electric shock hazard Before carrying out any work on the flame detector, isolate the power supply completely (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed isolated. If not observed, there is a risk of electric shock hazard Ensure protection against electric shock hazard by providing adequate protection for the burner control s connection terminals. If not observed, there will be a risk of electric shock Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state and that the correct terminals of the LMV5... are used and make the safety checks as described in Commissioning notes. If not observed, there is a risk of impairment of safety functions and of electric shock hazard Make certain that none of the 3 connecting wires of the QRI... is connected to terminal X10-02 pin 3 (mains voltage L)! Risk of damage to QRI... and LMV5...! Due to its mounting location behind the baffle plate, the flame detector has high signal sensitivity and, therefore, identifies small variations in infrared radiation as a flame. For this reason, make certain that so-called heat streaks after loss of flame (emitted for example by after-glowing combustion chamber lining) will not reach the detector as these would simulate a flame. Air turbulence or similar may modulate infrared radiation emitted by hot boiler or burner components in a way that a flame will be simulated. Likewise, moving parts in the detector s viewing range can cause infrared radiation from the boiler (or a viewing tube) to be modulated, thereby possibly generating sporadic detector signals. Strong burner or detector vibrations can also produce variations in radiation. For this reason, the burner or boiler manufacturer must make certain that such modulated radiation cannot reach the flame detector. For example, loose cables (moving up and down in the fan s airstream) are not permitted within the detector s viewing range. If this is not observed, there is a risk of loss of safety functions Consider carefully the use of infrared flame supervision if several burners use the same combustion chamber (if this is not observed, there is a risk of loss of safety functions). In general, this type of flame supervision is not suited for the specific supervision of individual burners Check to ensure that the burner will initiate lockout when while the burner is running the flame detector is removed from its fixing on the burner and without moving it is exposed to room lighting Fall or shock can adversely affect the safety functions. Such units must not be put into operation even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulations are complied with Secure the flame detector to the burner with the clamp and flange provided. With the clamp s fixing screw loosened, the detector can be correctly adjusted toward the flame. This adjustment can be checked by watching the intensity of the flame signal on the AZL5... display and operating unit of the LMV5... burner control, or with the help of the measuring circuit (see Detector signal measurement) Ensure that the connection between the metal surface of the flange and the burner s earthed housing is electrically conductive 2/12

Installation notes Locate the detector such that, if possible, only the flickering peripheral range of the flame will be detected. The view at hot boiler walls or other hot boiler or burner components must be restricted as much as possible. This can be attained by clearly confined viewing conditions behind narrow baffle plates. If this is not possible, a viewing tube should be used to restrict the viewing range to a smaller area of the flame. Length, diameter and alignment of the viewing tube must be determined through testing, depending on the size of burner and boiler The viewing range should be reduced to such an extent that: a) the minimum detector output signal required is attained over the burner s entire output range (for details, refer to the Basic Documentation of the LMV5... (P7550) b) after loss of flame, the valve s operating voltage is switched off by the burner control as required by the standards (see Commissioning notes). Electrical connection of the flame detectors It is important to achieve practically disturbance- and loss-free signal transmission: Never run the detector cable together will other cables - Line capacitance reduces the magnitude of the flame signal - Use a separate cable Observe the permissible length of the detector cables (see Technical data) Always run the ignition cable separate while observing the greatest possible distance to other cables (min. 3 cm) Test the flame detector on all applications. When used in connection with the LMV5..., the test is to be made with a test routine (for details, see the Basic Documentation P7550) Make certain that the detector s cable does not get into contact with hot burner or boiler surfaces Use an AC voltmeter (Ri = 10 MW) to ensure that there is no voltage across the reference line (blue wire = N of the LMV5...) and the burner housing (PE) Commissioning notes When commissioning the plant or when doing maintenance work, make the following safety checks: Safety check Anticipated response a) Burner startup with flame detector darkened Lockout at the end of safety time (TSA) b) Burner startup with flame detector exposed to extraneous light (e.g. light from an incandescent lamp interrupted at about 20 Hz) c) Simulation of flame failure during operation. For that purpose, darken the flame detector during operation and maintain this state d) Check the safety time in operation in the event of loss of flame; for that purpose, disconnect manually the fuel valves from power and check the time the burner control requires from this manual disconnection until the valves power supply is turned off Lockout at the end of the prepurge time Lockout or restart, depending on the burner control s configuration Burner control disconnects power supply to the valves within the period of time allowed for the relevant plant Make a loss-of-flame test with the AZL5... of the LMV5... burner control 3/12

Standards and certificates Note! Only in connection with burner controls! EAC Conformity mark (Eurasian Conformity mark) ISO 9001:2015 ISO 14001:2015 OHSAS 18001:2007 China RoHS Hazardous substances table: http://www.siemens.com/download?a6v10883536 For use in the U.S. / Canada, the flame detectors carry the marks. Service notes To clean the detector s lens, use a soft, clean cloth (free from oil and solvents). Disposal notes The flame detector contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. Mechanical design The QRI... has an impact-proof housing made of black plastic. The lens is fitted in a dust-tight position. The QRI... can be secured to the burner within its adjusting range, using the clamp and the flange provided. The 3-core connecting cable is ready connected to the QRI... and features cable strain relief. Depending on the type of burner construction, there are flame detectors for frontal or lateral illumination available. Type summary Article no. Type reference Illumination Cable length (L) Cable end BPZ:QRI2A2.B180B QRI2A2.B180B Frontal 180 cm Stripped --- BPZ:QRI2B2.B180B QRI2B2.B180B Lateral 180 cm Stripped --- Accessories BPZ:QRI2B2.B180B1 QRI2B2.B180B1 Lateral 180 cm Stripped 4 241 8898 0 Flange straight and clamp When ordering, please give the complete type reference according to Type summary. 4/12

Accessories Flange, with radius 4 241 8855 0 Article no.: BPZ:424188500 Flange, straight 4 241 8898 0 Article no.: BPZ:424188980 Clamp 4 199 8806 0 Article no.: BPZ:419988060 Mounting kit for frontal illumination AGG2.110 Article no.: BPZ:AGG2.110 Consisting of heat insulating piece AGG15 (¾ 14-NPSM thread), heat insulation glass, adapter sleeve and clamp Adapter, protective sleeve Pg9 / ½ 14-NPSM thread AGG2.120 Article no.: BPZ:AGG2.120 Mounting coupling AGG04 Article no.: BPZ:AGG04 Adapter of ¾ 14-NPSM thread for a European pipe thread (G1"). Heat insulating piece (spare part) AGG15 Article no.: BPZ:AGG15 Mounting of the mounting coupling AGG04 and the mounting kit AGG2.110 AGG2.110 QRI... AGG04 7719z03/1213 5/12

Technical data General detector data Operating voltage - Operation - Test Signal voltage Length of connecting cable Degree of protection Power consumption Length of auxiliary detector cable Safety class Vibrations to IEC 6068-2-6 Weight incl. cable 180 cm Mounting position DC 14 V ±5% DC 21 V ±5% DC 0...5 V Max. 180 cm IP54 <0.5 W Max. 100 m II Max. 1 g / 10...500 Hz Approx. 0.175 kg Optional Environmental conditions Storage DIN EN 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...+60 C Humidity <95% r.h. Transport DIN EN 60721-3-2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -20...+60 C Humidity <95% r.h. Operation DIN EN 60721-3-3 Climatic conditions Class 3K5 Mechanical conditions Class 3M2 Temperature range -20...+60 C short-time (max. 1 min) up to 75 C Humidity <95% r.h. Installation altitude Max. 2,000 m above sea level Attention! Condensation, formation of ice and ingress of water are not permitted! If not observed, the safety functions are no longer ensured and there will be a risk of electric shock. 6/12

Function Maximum detector cable length With this type of flame supervision, the changes in infrared radiation are used to generate the flame signal. The flame-detecting element is an infrared-sensitive photoresistor whose spectral sensitivity covers the range of approximately 1...3 µm. The detector does not respond to constant radiation or radiation with mains frequency harmonics (e.g. 50 Hz or multiples thereof). The suppression of these radiation frequencies is made electronically, directly dependent on the current mains frequency at which the relevant burner control (e.g. LMV5...) is operated. As a result, filtering takes place within a very narrow band, which means that the signal generated by the flame can almost completely be utilized since the frequency and the rate of change of infrared radiation constantly change. Hence, the detector s ability to capture the flame s radiation behind the burner s baffle plate is extremely high. As a result of the high level of sensitivity, constant or mains frequency-harmonic extraneous light sources remain undetected only if the detector itself is not moved. Due to its short-wave spectrum, the ignition spark will not be detected. The detector s analog output signal (0... approx. +5 V) is a measure of the changes of the flame s radiation intensity. If the connecting cable length of 180 cm is not sufficient, the burner manufacturer can extend it up to a maximum of 100 m (also see Installation notes). SIEMENS Landis & Staefa QRI Made in Germany sw bl br 7719m04/1199 max. 1,8 m Z < 100 m Legend bl Blue wire = reference line sw Black wire = signal line br Brown wire = power line Z Extension cable 7/12

Spectral curves Flames Relative intensity of radiation 3 2 a c b 7719d01e/0700 1 b d 0 0 1 2 3 Wave length (µm) d 4 5 Spectral emission of radiation of luminous and nonluminous flames at 1,500 K (extract from VDI Report no. 423, 1981). Legend a b c d Black body radiation Pulverized coal flame Oil flame Gas flame Sensitivity of flame detector 100 % 7719d02e/0302 Typical relative sensitivity 10 % 1 % 1 1.5 2 2.5 3 3.5 4 Wave length (µm) 8/12

Measuring circuit and connection examples Measurement of the detector current See Signal voltage in Technical data. Made in Germany sw bl br LMV5... X10-02 / 6 X10-02 / 4 X10-02 / 2 7719a01/1213 + 0...10 V Ri > 10 M Measurement of the detector s signal with a Voltmeter is not normally required since the flame signal s intensity is shown on the AZL5... display and operating unit. Drawing of disposition AGG2.110 Mounting kit is supplied completely assembled. Clamp Adapter sleeve Heat insulation glass Adapter nipple (heat insulator) 7719z01/0314 9/12

Dimensions Dimensions in mm QRI2B... for lateral illumination 56 40 12 69 144,5 22 18 Made in Germany 55,7 7719m02/0603 156 L QRI2B... viewing angle 7719z04/0216 ca. 10 ca. 10 IR Legend IR L Infrared rays Available cable length (see Type summary) QRI2A... for frontal illumination 56 40 69 144,5 22 18 55,7 6,8 162,8 L 7719m08/0603 QRI2A... viewing angle ca. 10 IR ca. 10 7719z05/0216 Legend IR L Infrared rays Available cable length (see Type summary) 10/12

Dimensions (cont d) Connecting cable Cable ends stripped Brown Blue 40 + - 1 7 + - 0,5 7719m01e/0302 Black Mounting kit AGG2.110 Clamp (4 199 8806 0) + adapter sleeve + heat insulating piece 12 70 25 24 34 3/4"-14NPSM 7719m11/1013 Adapter AGG2.120 6,5 7719m06/0302 Pg9 1/2"-14NPSM SW24 7,5 28,5 11/12

Dimensions (cont d) Mounting coupling AGG04 69.9±0.5 3/4"-14NPSM Pipe thread ISO228/1-G1 SW 36 3/8 cooling air supply 7711m02e/1010 SW 21 Flange straight 4 241 8898 0 36 18 7 R4 25 3 15 30 7719m09e/0608 Company logo to LN 3 8380 0102 0,2 mm elevated 3 10 24 48 Flange with radius 4 241 88550 36 24,3 R2 R4 7 R0,3 R2 30 R40 25 3 15 7719m10e/0114 Company logo to LN 3 8380 0102 0,2 mm elevated 3 10 18 24 48 ã2018 Siemens AG, Berliner Ring 23, D-76437 Rastatt Subject to change! 12/12