Installation & Maintenance Instructions

Similar documents
SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

K Series (Model A) Fan Forced Wall Heaters

Installation & Maintenance Instructions

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

SAVE THESE INSTRUCTIONS

R Series B & T2 Model

Electric Space Heater

Tab 8. Cove Heaters HARRIS AIR IN THIS SECTION S"YSTE1V1S, INC. HearinB &..-Air CondirioninB Insrallarion &..-Service

FLCH4R Garage and Utility Electric Heater

... a. Electric Baseboard Heaters IN THIS SECTION J b t S. SY-STEl\t1S, I~C_

CPL Series Pedestal Convection Heater

DH Series Portable Industrial Unit Blower Air Heaters

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

Installation & Maintenance Instructions

Installation & Maintenance Instructions

Installation & Maintenance Instructions

IMPORTANT INSTRUCTIONS

Installation & Maintenance Instructions

ARWH Series Smart Series Architectural Wall Heater

Quest Power Electric Heat EHS 31 Pro

Owner s Manual Phoenix FireBird

HI Industrial Utility Heater HI Soleus Air International

IMPORTANT SAFETY INFORMATION

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Quest Power Electric Heat EHS 62 Pro

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

READ AND SAVE THESE INSTRUCTIONS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

40E ELECTRIC FAN HEATER

USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED

Easy installation in both new construction and retrofit

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

40E ELECTRIC FAN HEATER

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

MaxLite LED Round Pendant Highbay Series

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

User s guide RUH series Economical unit heater Replacement component list included

INSTALLATION, OPERATION AND MAINTENANCE

Spa Control System OWNER S MANUAL

Easy installation in both new construction and retrofit

Installation Instructions

MH70230AS MH70236AS MH70248AS

VSA/VSB & KSA/KSB Series Air Doors

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

AG Series Electric Heaters

Installation Instructions

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Brasch Hazardous Location Unit Heaters

Installation instructions for Plenum-mounted add-on electric heaters

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Installation and Maintenance Manual IM 1102

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Installation Instructions

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

e Heater/Exhaust Fan/Light User s Guide

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

X Series (Model B) Explosion Proof Heater

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS

MaxLite LED MICRO-T PANEL

Bathroom Exhaust Fan/Fluorescent Light Combination

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

18E ELECTRIC FAN HEATER

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Electric Duct Heaters

Installation Instructions

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Type UB-2502A and UB-3002A Forced-Air Heater

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³).

120 VAC SYSTEM CONTROL KIT

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

Installation, Operation & Service Manual

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

e Bath Fan with Light User s Guide

Transcription:

PRH Series Plenum Heaters Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating industry. Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry s leader in design, manufacturing, quality and service.... The Employees of Marley Engineered Products! WARNING Read Carefully - These instructions are written to help you prevent difficulties that might arise during installation of heaters. Studying the instructions first may save you considerable time and money later. Observe the following procedures and cut your installation time to a minimum. TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK: 1. Disconnect all power coming to the heater at main service panel before wiring or servicing. Note: More than one disconnect may be required. 2. All wiring must be in accordance with national and local electric codes and the heater must be grounded. 3. Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing. 4. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. 5. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock, fire, or damage to heater. 6. Do not block air intakes or exhaust in any manner. 7. A heater has hot and arcing (sparking) parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored. 8. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury. 9. This heater is not approved for use in corrosive atmospheres such as marine, green house, or chemical storage areas. 10. FOR DUCT CONNECTED HEATERS, rated at 0.20 external static pressure. SAVE THESE INSTRUCTIONS

GENERAL INFORMATION: The PRH Series plenum heaters are design certified by ETL to Standard for Heating and Cooling Equipment ANSI / UL 1995, CAN/CSA C22.2 No. 236-05, third edition. The PRH Series plenum heaters are unique application heaters approved for installation in a concealed space, an area between a finished ceiling and drop ceiling, a plenum space or inside a plenum. These series of heaters may be installed in areas that are not readily accessible and may be installed with a duct system or installed for free-air discharge. Always install units to operate within the intended temperature rise, intended external static pressure range and in the intended installation position (see Figure 2 horizontal-right). Figure 2 AIRFLOW DIRECTION MOUNTING: The PRH Series plenum heaters are intended to be mounted in the horizontal-right installation position (see Figure 2) and in a suspended manner. The unit can be rotated on its axis in any position needed (can not be mounted vertically). Suspend the unit from the building structure in a horizontal plane. Units must be independently supported. Support channels or straps are intended to be permanently attached to unit frame/housing. Be careful not to obstruct access to control panel with support channels or straps. DUCT CONNECTIONS / DUCTING: The PRH Series plenum heaters may either be installed for free-air discharge or with a duct system. The proper sizing of warm air ducts is essential in providing satisfactory heating operation. Ductwork should be in accordance with the latest editions of NFPA-90B (Warm Air Heating and Air Conditioning Electrical Knocknot Ground Connection Power Connection Figure 3 12 Small 11.64 Large 10 Small 15.32 Large Systems) or Canadian equivalent. Every PRH model is equipped with an inlet and outlet grille for free-air discharge. Both grilles are intended to be removed when connecting to a duct system. The inlet and outlet ends of the unit are equipped with perforated flanges to aid in forming both inlet and outlet duct flanges (see Figure 3). These perforations will aid in forming a rectangular inlet and outlet duct flange if they are desired for connection to the duct system. The unit is designed for a rectangular flange duct connecting and the clear area around the flange is intended for screw penetration. This feature aids in attaching the duct work to the unit so that the ductwork may be fastened and sealed to the unit. CONTROL ACCESS: The front door allows access to all the controls and components within the unit. The unit is design certified for 0 clearances however, while installing the unit, be careful not to obstruct access to this control panel. This panel allows access to the unit for making the power connection, the thermostat connection and is intended to allow access to all the internal components that make up the unit. ELECTRICAL CONNECTIONS: All field wiring must comply with NEC and local codes. NOTE: SEE PAGE 3 & 4 FOR WIRING DIAGRAMS All units are designed for a single point connection to supply power to the fan and electric heater. The PRH series plenum heaters are shipped standard with a 80 amp 3-pole disconnect switch. Field power connections are made to the line side of this disconnect switch (see Figure 4). Each unit is equipped with a grounding lug for ground connec- Figure 4 tion. The unit must be properly grounded to comply with NEC and local codes. Before making the power connection, insure that the line voltage to the unit matches the ratings located on the nameplate of the unit. All units should have copper wire sized for 125% of nameplate amperage. Disconnect the power supply before wiring the unit and insure the disconnect switch is in the OFF position while making power connections or servicing the unit. The unit cabinet has a 7/8 electrical knockout for routing power supply to the disconnect switch (see Specifications section for knockout location). Should the unit require a larger electrical conduit connection, this electrical knockout is intended to serve as the pilot hole in order to field convert to larger electrical connections. 2

CONTROL CONNECTIONS: The PRH Series plenum heaters are designed to operate from a 24VAC thermostat. Model TH5220D1003 24V 2 stage thermostat is recommended to be used with the PRH Series heaters. Thermostat connections are made to the thermostat board located inside the unit. The thermostat label indicates which connections are (RGCW) for making these thermostat connections. The unit cabinet has a 3/8 knockout for routing thermostat wiring to the units thermostat board (see Specifications section for knockout location). Instructions for wiring the thermostat are packed with the thermostat. The unit is intended to operate with heat (W) and fan (G). If the unit is intended for cooling signals from the thermostat, make the Y connection from the thermostat to the G connection on the unitʼs thermostat board. UNIT OPERATION: The PRH Series plenum heaters are intended to be operated from a 24V thermostat. (Model TH5220D1003) HEATING OPERATION When there is a demand for heat, the thermostat sends a signal to the unit for this demand for heat. The unitʼs thermostat board will send power to the unit controls to initiate the heating operation. The call for heat makes the connection on the thermostat board by powering W with R. Upon this demand for heat, the heating element starts heating and the fan on delay will power the fan within 60 seconds from the call for heat. The fan delay ensures that there will not be a cold blast of air to ensure comfort heating. When the heat demand has been met, the thermostat will send the signal back to the unitʼs thermostat board to stop the heating operation. This breaks the power connection between R to W and the heating element stops heating immediately. The fan off delay allows the fan to continue running to remove all residual heat from the heating element and will turn the fan off within 60 seconds. Should there be any abnormal conditions to cause the units limit to open during the call for heat, the units heat will turn off immediately but the fan will go through its normal off delay. During this open limit period, the power to the thermostat will be interrupted until the limit closes. This helps in determining abnormalities during heating operation by way of interrupting power to the thermostat. FAN OPERATION When there is a demand for fan, the thermostat sends a signal to the unit for this demand for fan. The unitʼs thermostat will send power to the unit controls to initiate the fan operation. The call for fan makes the connection on the thermostat board by powering G with R. The fan will immediately come on and continue to run until the demand for fan has ended. When the fans demand has been met, the fan will immediately turn off. This breaks the power connection between R to G. HEATING OPERATION + FAN OPERATION When there is a demand for both heat and fan at the same time, the heating element will come on immediately as well as the fan. The fan on delay will be bypassed. Upon completion of the demand for both heat and fan, the heating element will turn off immediately. However, the off delay will work the same as during the heating operation. COOLING OPERATION Should the unit be used for cooling, the Y connection from the thermostat should be connected to the G on the thermostat board. The cooling operation will operate like the fan operation above. WIRING DIAGRAMS Single Phase - Single Element Three Phase - Single Element 480V 3

WIRING DIAGRAMS Cont. Three Phase - Single Element Single Phase - Dual Element Three Phase - Dual Element 480V Three Phase - Dual Element 4

WIRING DIAGRAMS Cont. Single Phase - 2 Stage Heat Three Phase - 2 Stage Heat 208V, 240V Three Phase - 2 Stage Heat 480V 5

9 1 6 2 11 10 4 3 8 7 5 Replacement Parts KEY DESCRIPTION 3KW 5KW 7.5KW 10KW 15KW QTY 1 Blower Assembly 1225-2022-000 1225-2022-000 1225-10158-000 1225-10158-000 1225-10158-000 1 2 Contactor / relay 5018-0005-004 5018-0005-004 5018-0005-004 5018-0005-004 5018-0005-004 1 3 Time Delay Relay 410171001 410171001 410171001 410171001 410171001 1 4 Fan Relay 5018-2024-000 5018-2024-000 5018-2024-000 5018-2024-000 5018-2024-000 1 5 Element 208V 302006850 302006804 302006809 302006804 302006809 1 240V 302006851 302006852 854 302006852 854 1 277V 302006838 302006840 855 302006840 855 1 480V 302006853 302006807 302006810 302006807 302006810 1 6 Motor 208V 3900-2094-000 3900-2094-000 3900-10160-002 3900-10160-002 3900-10160-002 1 240V 3900-2094-000 3900-2094-000 3900-10160-002 3900-10160-002 3900-10160-002 1 277V 3900-2095-000 3900-2095-000 3900-10162-000 3900-10162-000 3900-10162-000 1 480V 3900-10164-000 3900-10164-000 3900-10164-000 3900-10164-000 3900-10164-000 1 7 Motor Plug 6109-8090 6109-8090 6109-8090 6109-8090 6109-8090 1 8 Primary Limit Control 1414-2040-000 1414-2040-000 1414-2040-001 1414-2040-001 1414-2040-001 1 9 Capacitor 1432-0002-001 1432-0002-001 1432-0002-VAR 1432-0002-VAR 1432-0002-VAR 1 10 Disconnect Switch 5216-2039-000 5216-2039-000 5216-2039-000 5216-2039-000 5216-2039-000 1 11 Transformer 208-240V 5814-0003-000 5814-0003-000 5814-0003-000 5814-0003-000 5814-0003-000 1 277-480V 5814-0003-001 5814-0003-001 5814-0003-001 5814-0003-001 5814-0003-001 1 480V 5814-0003-002 5814-0003-002 5814-0003-002 5814-0003-002 5814-0003-002 1 Note: Use capacitor P/N 1432-0002-002 with motor P/N 3900-10160-002. All other motors will use capacitor P/N 1432-0002-001. 6

DIMENSIONS - SMALL CABINET DIMENSIONS - LARGE CABINET IMPORTANT INFORMATION LOW SPEED** HIGH SPEED** WT. CATALOG NUMBER PHASE KW VOLTAGE AMPS* CFM RISE CFM RISE LBS H X W X L PRH138124 208 15.32 PRH132124 1 3 240 13.4 PRH137124 277 11.63 PRH138324 208 9.23 350 27ºF 400 24ºF 49 12.5 x19.5 x24 PRH132324 3 3 240 8.12 PRH134324 480 4.11 PRH158124 208 24.94 PRH152124 1 5 240 21.73 PRH157124 277 18.85 PRH158324 208 14.78 350 45ºF 400 39ºF 49 12.5 x19.5 x24 PRH152324 3 5 240 12.93 PRH154324 480 6.51 PRH158124L 208 24.94 PRH152124L 1 5 240 21.73 PRH157124L 277 18.85 PRH158324L 208 14.78 850 20ºF 1000 16ºF 49 18 x18 x35.5 PRH152324L 3 5 240 12.93 PRH154324L 480 6.51 PRH1758124 208 38.12 PRH1752124 1 7.5 240 33.31 PRH1757124 277 28.91 PRH1758324 208 22.88 850 28ºF 1000 24ºF 69 18 x18 x35.5 PRH1752324 3 7.5 240 20.1 PRH1754324 480 10.16 PRH1102124 1 10 240 43.73 PRH1107124 277 37.93 37ºF 31ºF PRH2102124 1 10 240 43.73 PRH2107124 277 37.93 850 37º / 20ºF 1000 31º / 16ºF PRH1108324 208 29.82 PRH1102324 3 10 240 26.12 37ºF 31ºF PRH1104324 480 13.17 PRH2108324 208 29.82 69 18 x18 x35.5 PRH2102324 3 10 240 26.12 850 37º / 20ºF 1000 31º / 16ºF PRH2104324 480 13.17 PRH1158324 208 43.9 PRH1152324 3 15 240 38.14 850 56ºF 1000 47ºFº PRH1154324 480 19.18 PRH2152324 3 15 240 38.14 PRH2154324 480 19.18 850 56º / 28ºF 1000 47º / 24ºF *Total Amps including Resistive and Inductive loads. **Low speed fan operation not available on 480V models. Low and High speed fan operation is determined during installation of thermostat set up Tested @0.2 S.P. 7

MAINTENANCE & REPAIR Note: Periodic maintenance and repair should be performed by qualified personnel only. 1. Periodically inspect all electrical connections and terminals to avoid electrical wiring difficulties. Inspect all wiring for frayed or worn insulation. 2. Periodically and before each heating season, clean the steel finned elements and fan inlet with compressed air, vacuum, or feather brush. Be sure all electrical covers are tightly closed. 3. If heat output seems to be low, check amperage draw on each element leg. Compare measured values to the correct currents as listed on the unit nameplate. 4. The thermally protected fan motor is permanently lubricated and sealed. No field servicing is required unless needed. Replace only with a factory supplied identical motor or blower. 5. Check blower rotation to be sure that no is inside blower housing. TROUBLE SHOOTING Problem Potential Cause Solution 1. Motor does not operate. > Fan delay not operating and /or connected. > Check connections > Disconnect switch is open > Energize circuit > Blower motor damaged > Verify and relace if necessary > No power supply > Verify and energize circuit > Blocked blower wheel > Verify and unblock wheel for proper rotation 2. Heat not working. > Heating elements are not energized > Check connections and operation > Electical components may be open > Check disconnect, fuses, and circuit breaker > Fan delay not connected. > Check connections > Safety thermal limits opened > Check, verify and replace if necessary > Incorrect wattage or voltage of element > Verify and replace if necessary > Thermostat setting too low > Rotate dial clockwise to a higher setting 3. Airflow is insufficient. > Air filters restriction airflow > Check, clean, and or replace filters > Blocked blower wheel > Verify and unblock wheel for proper rotation. LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the productʼs installation instructions. All claims for warranty work must be accompanied by proof of the date of installation. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center.Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WAR- RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGI- NEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PROD- UCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products. Part No. 5200-2834-004 ECR 38777 07/10 470 Beauty Spot Rd. East Bennettsville, SC 29512 USA 8