Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8

Similar documents
Member of the NIBE Group. Process Heating

Gillelejevej 30b DK-3230 Graested Tel.: Fax: Member of the NIBE Group

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

ZAK M MC KHK Z ZAW ZWM heater: aluminium clamp band: stainless steel or FAL

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

Electric Air Heating Standard product ranges

Explosion-proof Immersion Heater Type D-8660

QZHW Fan Coil Unit. Key features. Specifications

Custom Duct Heaters. Special Applications

MANUFACTURER OF HEATING ELEMENTS

EHH SERIES DRAW THROUGH FAN COILS CFM

ELEMENT WIND SOLUTIONS NIBE ELEMENT WIND SOLUTIONS RELIABILITY ENERGY EFFICIENCY SUSTAINABILITY

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Fan Heaters Type VLEx

Finned Tube Air Heaters Type WD/GG (RVS)

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Tubular Industrial Process

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Hazardous Area Portable Fan Heater The Bulldog

Recessed. Air Curtain. Fig 1. Recessed air curtain

Custom Duct Heaters. Special Applications

LUH HORIZONTAL FAN-FORCED UNIT HEATER

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

Hazardous Area Portable Fan Heater The Bulldog

( )

(770) wwww.southgateprocess.com

FX5 Series Explosion-Proof Electric Air Heaters

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Design Specifications for Panda 900A Car Spray Booth

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

CR1 Series Triton Corrosion Resistant Washdown Heaters

HEATERS MOUNTED ON THREADED PLUG

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

CAW Ceiling-mounted fan heaters for hot water

Hazardous Area Portable Fan Heater The Bulldog

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Gas heaters and convectors ROBUR

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

ATC Heating Devices. P. 1 ATC Heating Devices

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Original instructions. Panther 6-15 kw

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Cleaning System. Amajet. Type Series Booklet

CX1 ProVector Explosion-Proof Heaters

Screw plug immersion heaters

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Condensing Units CUS 15-60

HEATING ELEMENTS FOR WATER HEATING output 500W W water and similar liquid heating

Electric Water Heaters. The STRENGTHS of the product range in detail:

Immersion Heaters. Screw Plug Immersion Heater

Heating Products M arch 2012

FE1 Explosion-Proof Electric Air Heaters

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Flange immersion heaters

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Business Hand dryer High Speed

BRISE. Super-power for heating, cooling and ventilation.

Tubular Heaters Series

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

ULTRA-SAFE Explosion-proof Duct Heaters

MacroAir AirElite HVLS Fans

CASSETTE UNIT. Comfort Circle

Panel Fan Series Operators Manual (Galvanized and Polymer)

INSTALLATION, OPERATION & MAINTENANCE MANUAL

QZB "Standard" comfort fan coil

Flanged Immersion Heaters

Description. Construction

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

Installation and Wiring Instructions

Tubular Industrial Process

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Flanged Immersion Heaters

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

KUH. Horizontal Unit Heater. Applications. Description

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Installation and Maintenance Manual Please retain this manual for future reference.

Silicone Rubber Insulated Heater

Flanged Immersion Heaters

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

CF1 ProVector Explosion-Proof Heaters

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Brochure EX

Installation, operating and servicing instructions

Installation and operating instructions. DK energy storage and DK energy buffer

PRODUCT RANGE: ROOFTOP PACKAGE

Type CODE Speed Heating Cooling

ROBUST Electric fan heaters for demanding environments

Transcription:

Air Heating

Table of Contents Page Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8 Electrical heaters for duct heating: Electrical heaters, round ducts... 10 Insertion heaters... 11 2

Member of the NIBE Group Portable Hot Air Fans Type TEA Type TEA is used for heating of bigger rooms. It has 3 heating levels, protection class IP 44 and is delivered with 2 m cable. It is equipped with 2 limiters, one with automatic reset, one with manual reset. The fan has a built-in overheating fuse, which automatically starts the fan after over-heating. Type TEA 15-32 can all be connected in 3 levels. TEA 40 can be connected in 4 levels. Type Power kw Voltage V Current Amp Air volume m 3 /h Δt C Weight kg Part no. TEA 15 15 3x400 22 1300 33 17 83400 TEA 26 26 3x400 38 2900 25 30 83402 TEA 32 32 3x400 47 2900 33 32 83404 TEA 40 40 3x400 59 2900 40 34 83406 Type BSP is especially designed for use in rooms with minor danger of fire. This can e.g. be farming, carpenter's and joiner's workshops. Not applicable for rooms containing huge masses of dust. NON EX. Technical data: Protection class: IP 54. The fan is protected by a thermo release, which switches off the fan and heating elements. The heating elements are protected against overheating by a limiter. Type BSP is equipped with no-voltage release. At drop outs the hot air fan can only be started manually by a push button. Lowest distance to flamable material: 1.0 m. Delivered with 10 m rubber cable and plug. Type BSP is also available for stationary mounting Type Power kw Voltage V Current Amp Air volume m 3 /h For rooms with danger of fire Type BSP Δt C Weight kg Part no. BSP 2 2 230 9 400 14 6 83335 BSP 4 4.5 3x400 7 950 14 15 83336 BSP 6 6 3x400 9 950 18 16 83337 BSP 9 9 3x400 13 1300 21 17 83338 3

UL Fan Heater 3kW-9kW Description This fan heater is a rigid and reliable fan heater designed for harsh weather and rough environments, where fine materials and high performance are required for nacelle heating and others. The fan heater is performing superbly down to -40ºC and in high altitude. This heater is therefore the perfect choice for high quality wind turbines in cold climate conditions. The technology has been used successfully for more than 15 years and ongoing development secures that these products still perform as quality units in the next generation of turbines. The UL approved heaters can be supplied from 3-9kW as standard. The heater is supplied with wall bracket. Technical Data A limiter is installed for safety against overheating. The fan heater is designed with an inner round shell which ensures that the entire air flow passes over the heating elements. In this way problems with cold areas and stagging airflow are avoided. The fan heater is supplied in different voltages, therefore all types are available from 240 V - 600 V. NEMA 2 cover. Coating The fan heater is made of electrogalvanized steel plates coated with a 20 my coating in RAL 04 (light grey). When ordering large quantities the fan heaters can be supplied in other colours. Permanent Installation Using the wall bracket the fan heater can be mounted vertically or in a 15 angle. Electrical Installation Permanent installation must be carried out by an authorised electrician in compliance with current regulations. kw Volt Amp m 3 /h Δ T db(a) Part no. 3 240 12,5 450 19ºC 35 69825309 4,5 240 18,8 650 20ºC 42 69825090 3 3x240 7,2 450 19ºC 35 69825308 6 3x240 14,4 650 28ºC 42 69825307 3 3x400 4,3 450 19ºC 35 69825306 6 3x400 8,7 650 28ºC 42 69825305 9 3x400 13,0 800 32ºC 45 69825304 3 3x480 3,6 450 19ºC 35 69825303 6 3x480 7,2 650 28ºC 42 69825302 9 3x480 10,8 800 32ºC 45 69825099 3 3x600 2,9 450 19ºC 35 69825301 6 3x600 5,8 650 28ºC 42 69825300 9 3x600 8,7 800 32ºC 45 69825089 4

Member of the NIBE Group Fan Heater 3kW-21kW Description This fan heater is a rigid and reliable fan heater designed for harsh weather and rough environments, where fine materials and high performance are required for nacelle heating and others. The fan heater is performing superbly down to -40ºC and in high altitude. This heater is therefore the perfect choice for high quality wind turbines in cold climate conditions. The technology has been used successfully for more than 15 years and ongoing development secures that these products still perform as quality units in the next generation of turbines. Technical Data The fan heater is supplied with a 0-40 C thermostat which ensures an optimum service and minimises the electrical consumption. A limiter is also installed for safety against over heating. The fan heater is designed with an inner round shell which ensures that the entire air flow passes over the heating elements. In this way problems with cold areas and stagging airflow are avoided. The fan heater can be delivered in different voltages 110V - 690V. Degree of protection: IPx4. Options can be delivered with different wall bracket systems. can be delivered with different cable lengths. Coating 373 419 The fan heater 320 is made of electrogalvanized 299 steel plates coated with a 20 my coating in RAL 04 (light grey). When ordering large quantities the fan heaters can be supplied in other colours. 73.5 Electrical Installation Permanent installation must be carried out by an authorised electrician in compliance with current regulations. 322.5 373 320 299 419 444.5 373 320 299 419 C thermostat cut out 322.5 139 73.5 322.5 age : 1250V B B B Description Volt kw m 3 444.5 /h Δ T db(a) Routine high voltage test : 1250V 444.5 3000 230 3 450 19ºC 35 3000 3x400/690 3 450 19ºC 35 6000 3x400/690 6 650 28ºC 42 9000 3x400/690 9 800 32ºC 45 15000* 3x400/690 15 1400 30ºC 52 21000* 3x400/690 21 1400 SAN 42ºC SAN 52 *Dimensions have to be informed. 0-40 C thermostat 165 C cut out 139 B Routine high voltage test : 1250V B 5

SAN Hot Air Fan Application: Hot air fan for heating and temperature maintenance in the nacelle. All equipment is delivered approved according to international standards, including corrosion-, shock- and vibration tests. Technical data: Output: 5-50kW Voltage: 110-3x690V Volume of gas: 7m/s Op. temperature: -40 to +55 C Casing: IP 55 Composition: Stainless steel Part No.: 10kW: 217252001 5kW: 207406001 and 207406002 6

Member of the NIBE Group SAN Air Heater for wind turbines Description: SAN special designed air heater for frost protection in wind turbines manufactured from galvanized steel consisting of a hexagon duct with forced ventilation from a built-on fan. The terminal box is made from painted steel, with enclosure IP65, containing electrical components and terminations. The heater unit has heavy mounting fixtures in galvanized steel mounted to the surface for fixture in the right position in the wind turbine. The built-in heating elements are made from stainless steel AISI 316Ti and bent into shape to secure perfect heat transportation from the heating element into the air. The air heater is overheat protected by an adjustable limiter with reset located near the surface of the heating elements. All equipment is approved according to international standards, including corrosion, shock and vibration tests. Technical data: Type I Type II Optional Output 5kW 10kW 2,5kW - 50kW Voltage 3x690V 3x690V 3x400V - 3x690V Air flow 2500m 3 /h 2500m 3 /h 800m 3 /h - Temperature range -40 to +55 C -40 to +50 C -40 to +50 C Protection class IP65 IP65 IP65 Casing Galvanized steel Galvanized steel Galvanized/Stainless steel Motor rpm 1380 1380 750-3000 Application: Nacelle heating - Tower heating 7

Air Curtains Type LPX, LSK SAN hot air curtains is especially designed for use over front doors and smaller gates, but is also applicable for many other applications, e.g. for heating and drying in the industry. Delivered with power from 2 kw to 10 kw, where the 2 kw type, LPX 2, is especially applicable for minor openings, such as e.g. hot-dog stands, serving hatches etc. Description of type LPX2 Manufactured from galvanized steel plate with drum fan and stainless pipe heating elements. 2-level switches for air volume and power (1/2-1/1). Thermostat and thermo relay with manual reset (behind the front cover). 2 m wire with plug. Protection class: IP 20. Sound level: 40/48 db. Thermostat: 5 C-35 C. Colour: RAL 9010 (white). Voltage: 230 V. Width: 800 mm. For use at front doors, e.g. in airports, gas stations etc. the heavier types, LSK are recommended. At wide door openings, e.g. at malls or industrial gates, the type RA is recommended. Description of type LSK Manufactured from galvanized steel plate with drum fan and stainless tubular heating elements. Equipped with complete adjustment: 0 - vent. - heating level 1 + 2, thermostat 0 C-40 C and 2 limiters. Protection class: IP 20. Sound level: 42/53 db(a). Colour: RAL 9010 (white). Voltage: 3x400 V Type LSK = 1 m wide. Type LSD = 1.5 m wide. H: 2 mm, D: 240 mm. Type Power kw Air volume m 3 /h Δ T C Weight Part no. LPX 2 2 230/460 25/13 9 83339 LSK 3 3 900/1200 10/7 15 83340 LSK 6 6 900/1200 19/4 15 83341 LSK 9 9 900/1200 29/21 15 83342 For type LSK - LSD a remote control box can be delivered, which can adjust up to 6 hot air blankets. Temperature control still on each unit. BB Separate control box 83339 8

Member of the NIBE Group Air Curtains Type RA Description In principle the type RA recirculates the existing, heated air in the room, which is let out through adjustable plates at high speed. This way an ef-fective air stop is obtained and at the same time the temperature difference between ceiling and floor is equallized. Type RA can also be delivered with heating unit, either for central heating (up to 69 kw) or with electrical surface (up to 36 kw). It is neccessary to dimension type RA depending on the actual assignment. Please contact our sales department. 9

Electrical Heaters for duct heating SAN round electrical heaters have been designed for building-into spiro ducts. They are manufactured from hot galvanized steel plate mounted with stainless steel tubular heating elements and equipped with terminal box with BK gland for each group. With built-in temperature limit type TGS 140ºC with manual reset and fire thermostat with automatic reset. Specific watt load : 3 W/cm 2 Min. wind velocity : 3 m/sec. ELECTRICAL HEATER RVF 3 x 400 V Type Power Dimensions Part kw Ø D x L mm no. RVF 16/36 3.6 160 x 250 55500 RVF 16/54 5.4 160 x 250 55510 RVF 16/72 7.2 160 x 250 55515 RVF 25/87 8.7 250 x 350 55520 RVF 25/116 11.6 250 x 350 55525 RVF 25/145 14.5 250 x 350 55530 RVF 25/174 17.4 250 x 350 55535 RVF 315/210 21.0 315 x 550 55540 RVF 315/280 28.0 315 x 550 55543 RVF 315/350 35.0 315 x 550 55545 Type RVF SAN electrical heaters are manufactured from stainless tubular heating elements, mounted in galvanized sheet iron frame with 30 mm flanges and equipped with terminal box and BK gland for each group. With built-in temperature limit type TGS 140 C with manual reset and fire thermostat with automatic reset. Specific watt load : 3 W/cm 2 Min. wind velocity : 3 m/sec. ELECTRICAL HEATER FKV 3 x 400 V Type Power Dimensions Part kw H x W x L mm no. FKV-3/1 4.50 50450 FKV-3/3 6.75 50675 300 x 300 x 300 FKV-3/5 9.00 50900 FKV-3/7 18.00 51800 FKV-4/1 11.25 51125 FKV-4/3 18.00 51801 400 x 400 x 425 FKV-4/5 27.00 520 FKV-4/7 38.25 53825 FKV-5/1 24.75 52475 FKV-5/3 47.25 500 x 500 x 500 54725 FKV-5/5 76.50 57650 Type FKV Group division according to request. Each group must be multible of 2.25 kw. As tubular heating element, our standard types in stainless and acid proof steel are most often used, however, on demand, tube material MONELL 400, INCOLOY 800, INCONEL 600 or TITANIUM are used. Duct frame is in equal material. 10

Member of the NIBE Group Insertion Heaters Type RKV for duct heating SAN insertion heaters are for mounting in ventilation systems with spiro ducts. FOR TEMPERATURES UP TO MAX. 60ºC. SAN insertion heaters can be mounted and after-mounted on all spiro ducts by means of an application - easily and simple. SAN insertion heater is manufactured from hot galvanized steel plate with normal tight terminal box, with 2 PG 13.5 and terminal box for electrical connection. The heating element is in acid proof, stainless steel Werkstoff-No. 1.4435. Insertion heater Bending Spiro duct SAN insertion heater is equipped with over-heat protection consisting of 1 bimetal thermostat with automatic reset and 1 temperature limit, 1-pole with reset for manual reset in separate thermo well. SAN insertion heater can be reset to 4 different effects. D DEMKO approved. INSERTION HEATERS RKV Type Power W Part no. RKV 16 500/1000/2000 W - 230 V 30510 RKV 25 1500 W - 400 V 30516 Type RKV 16: 160 for mounting in spiro pipe 160 and 200, height = 145 mm Type RKV 25: 250 for mounting in spiro pipe 250 and 315, height = 155 mm Air velocity: 500 W - 230 V: min. 0.5 m/sec. 1000 W - 230 V: min. 1.0 m/sec. 1500 W - 400 V: min. 1.5 m/sec. 2000 W - 230 V: min. 2.0 m/sec. Other sizes, power and voltages are delivered according to specification. 11

Member of the NIBE Group Process Heating Heating Elements Heating Cables Finned Tubular Radiators Immersion Heaters Church Heating Frost Protection Ex-Material Oilfilled Radiators Drum Heaters Heating Pads Flow Heaters Air Duct Heaters High-voltage Resistors Controllers With more than 50 years of experience SAN Electro Heat s most valuable asset is special knowhow about design, product development and manufacturing of professional electrical heating equipment for industrial use. The company is geared to deliver 100% customized products, and thus functions both as a catalyst for a development project and as supplier of the final product. At the same time we insure and maintain the required quality level, mechanical and electrical dimensioning, approvals and documentation. Denmark, Mainoffice: Gillelejevej 30b DK-3230 Graested info@san-as.com tel.: +45 4839 8888 fax: +45 4839 8898 UK: Harold Comerford H_comerford@btconnect.com tel.: +44 1432 851999 mobile: +44 7802 853862 www.san-as.com Germany: Wolfgang Biehs wolfgang.biehs@nibe.de tel.: +49 6171 887 724 mobile: +49 1622 793 484 2014/December 16th