REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

Similar documents
INSTALLATION PROOF REGISTER YOUR PRODUCT. for warranty claims STAMP. Dealer. Date. here. Please complete and return. For the dental office:

METASYS. Amalgam separator ECONOMY SYSTEM TYPE 2 ECO II. Installation, operation and maintenance

ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

ECO MST 1. Separierautomatik MULTI SYSTEM TYP 1 ECO Gerätedokument Einbau, Betrieb und Wartung

METASYS. Central Suction System EXCOM hybrid 2/5. Equipment Logbook Assembly, operation and maintenance

METASYS. Amalgam Separator COMPACT A8 / A16. Installation, operation and maintenance

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

Syclone Amalgam Separator Installation and operating guide

NXT Hg5 Amalgam Separator Installation and Operations Manual

NXT Hg5 mini Amalgam Separator Installation and Operations Manual

Hg5 HV Amalgam Separator Installation and Operations Manual

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Hg5 Amalgam Separator Installation and Operations Manual

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Bona Portable DCS Manual and safety instructions

SUPERIOR PERFORMANCE

Table of Contents. English

Hoshizaki America, Inc.

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

Hoshizaki America, Inc.

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Tornado Operations & Maintenance Manual

V80-H Multistage Pump Instruction Manual

KM-900MAH KM-900MWH KM-900MRH KM-900MRH3

Aerosol flame projector with spark effect Safety instructions and operating manual

Operating Manual for Profident / Profident PLUS

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH HYDROPHOBIC VALVE

SELF-CONTAINED CRESCENT CUBER

GB Installation instructions DÜRR Combi-Separator 7110

Instruction Manual Spray Booth SK 66

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Tornado Operations & Maintenance Manual

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

Coffee Machine Zia series

Vacu-Mixer. Operating Instructions

User information. Cleaning/descaling and sanitizing

Operating Instructions

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Daily maintenance and checks

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

TECHNOSKLO Ltd. Držkov

USER S MANUAL ATH WH220

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Bona DCS70/Portable DCS Manual and safety instruction

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

OPERATING INSTRUCTIONS

Dental Unit User's Guide

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

TECHNOGEL AMERICA Cream Whipping Machine

KML-600MAH KML-600MWH KML-600MRH

MODEL 7000 SUCTION UNIT

hp Dust Collector With Vacuum Attachment

Hoshizaki America, Inc.

OPERATOR S MANUAL WET/DRY VACUUM PF51 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Light oil burners. One stage operation

Chapter 5 Checks and Maintenance

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-280MAH KM-280MWH INSTRUCTION MANUAL

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

PRO 2000i LOW LEVEL DEPOSITOR

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

Hoshizaki America, Inc.

Hoshizaki America, Inc.

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

CC Series VACUUM PUMPS

OPERATION AND MONTAGE MANUAL ROOF FANS

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

1 Intended Use of the Breas HA 01 Humidifier

DÜRR SUCTION SYSTEMS. High demands reliably exceeded DÜRR AMALGAM SEPARATORS

Page 1 of 18. Part# /5/2013

Models Goldfisch Fat Extraction Apparatus

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

ISSUED: FEB. 23, 1998 REVISED: OCT. 15, 1999 HOSHIZAKI MODULAR FLAKER MODEL F-450MAF(-C)

RC411 Operator Manual

Operating instructions. Mobile mixer LevMix (110 V - US) (Translation of the original operating instructions - English)

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

BarAid 400. Installation and. Starting from Serial No.:

Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

Care instructions ESTETICA E80. Always be on the safe side.

Coffee Machine Zia series

SASE BULL 240C. Dust Collection System Manual

Manual Page 1 of 8. Manual. Laboratory autoclave

Aluminum Heating Mantles

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Operating instructions. Web Cleaner 1 / 2. Air Line

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Transcription:

REGISTER YOUR PRODUCT for warranty claims INSTALLATION PROOF Please complete and return Fax: 305 662 7479 E-mail: pwd@metasys.com Dealer Date For the dental office: Please confirm that your technician has informed you about the following important points: Product function, operation, maintenance Warranty guidelines: Keeping service intervals Operation and cleaning with preparations recommended by the manufacturer Service documentation, return of installation proof Using GREEN&CLEAN M2 daily in order to clean your ECO II amalgam separator and your evacuation system STAMP here Dental office STAMP here Dealer

ECO II AMALGAM SEPARATOR Developed by Pure Water Development LLC Equipment Logbook Assembly, operation and maintenance PURE WATER DEVELOPMENT LLC THE WORLD LEADING COMPANY IN AMALGAM SEPARATION TECHNOLOGIES

Equipment logbook ECO II collection container replacement to be filled in by the technician service and maintenance must be carried out as per the instructions for the installation, operation and maintenance Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities Date of container replacement Dealer Other maintenance activities 2

Index Explanation of the pictograms Practice personnel, technicians 1. Index 3. General information The header on each page defines the user group particular information is aimed at. Chapter Page 1. Index 2 2. Explanation of the pictograms 2 3. General information 3 4. Application 4 5. Construction 4 6. Explanation of the type plate 4 7. Technical data 5 8. Functional description 5 9. Installation options 6 10. Replacement intervals 7 11. Installation ECO II 7 12. Installation ECO II Tandem 8 13. Hose connections between ECO II / ECO II 9 Tandem and EXCOM hybrid central evacuation systems 14. EXCOM hybrid A1 / A2 / A5 evacuation 10 systems with ECO II amalgam separation 15. Replacing the collection container 11 16. Disposal of the full collection container 12 17. Maintenance, cleaning and disinfection 13 2. Explanation of the pictograms i Information Caution! The safety, reliability and performance of the appliance is only guaranteed by PURE WATER DEVELOPMENT if the following instructions are observed: Assembly, alterations or repairs may exclusively be carried out by authorized service personnel in compliance with EN Standard 60601-1 (International Standard for Medical Electrical Apparatus, in particular Part 1: General Rules for Safety). The electrical installation must comply with the regulations of the IEC (International Commission for Electrical Engineering). The appliance must exclusively be used in conformity with the instructions for installation, operation and maintenance. Only original parts may be used for repairs or replacements. All the guidelines provided by the manufacturer on the correct use of the amalgam separator must be followed. Following the commissioning of the amalgam separator, the Installation Proof must be completed and returned to Pure Water Development to establish the guarantee period. Every inspection and servicing must be recorded in the Equipment Logbook. When requested by an authorized engineer, Pure Water Development agrees to make all documents available for the use of technically qualified service personnel. PURE WATER DEVELOPMENT accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention. Users must study equipment and assure themselves of its good condition before every use. Certificates of recycling for the amalgam waste (provided by recycling company) must be kept in accordance with national regulations. General warning sign The equipment is not suitable for use in explosive or combustible environment. 3

Application Construction Explanation of the type plate Practice personnel / technicians 4. Application 1 ECO II The ECONOMY SYSTEM TYPE II (ECO II) is a sedimentation amalgam separator for the installation after a central evacuation system or in the waste water pipe of the dental unit. When used in a liquid ring system, the ECO II can be installed in the suction line before the liquid ring pump. 5. Construction 1 ECO II combines the amalgam separator and the collector tank in one. This means that once the device is completely filled with amalgam waste, the entire ECO II is replaced. 6. Explanation of the type plate 2.5 2.6 2.1 2.2 2 See illustration The type plate is located directly on the front side of the amalgam separator. 2.1 Equipment type 2.2 Serial number 2 2.3 2.4 2.3 Manufacturer s address 2.4 Distributor s address 2.5 Max. suction volume 2.6 Max. water flow rate 4

Technical data Functional description Practice personnel / technicians 7. Technical data Low pressure range Separation rate Collection container volume Max. ambient temperature Possible evacuation systems Max. air flow rate Max. water flow rate Dimensions (H x W x D) Exchange interval 50 mbar - 300 mbar 99% in accordance with ISO 11143 0.4 gal (1.5 liters) 4.5 lb (ca. 2 kg) 0.18 gal (700 ml) amalgam wastes 104 F wet or dry 400 gal/min, 1,514 l/min 0.264 gal/min, 1 l/min 12.2 x 7.7 x 8.4 in (309 x 196 x 213 mm) approx. 12 months 3.1 3.4 3.2 3.3 3.5 3.7 Possible evacuation systems: dry-line vacuum generators with air/water separation, e.g. central evacuation system METASYS EXCOM liquid ring systems 3 3.8 3.6 8. Functional description 3 See illustration The amalgam separator ECO II works on the principle of sedimentation, divided into several sections. The waste water from the dental units runs from the central evacuation system with air/water separation into the inlet nozzle 3.1 of the ECO II. In liquid ring systems, the water flow from the suction line into the inlet nozzle. From there the waste water is led through the first large sedimentation chamber 3.2. Afterwards it is led through the first sedimentation cartridge 3.3, through cascades 3.4 and the second sedimentation cartridge 3.5 into the second sedimentation chamber 3.6. Through the third sedimentation cartridge 3.7 the cleaned water is led directly into the sewage pipe 3.8. In liquid ring systems, the clean water is led into the liquid ring pump. 5

Installation options ECO II / ECO II Tandem Technicians 9. Installation options 1.1 The ECO II allows a variety of different installation options. It is necessary to check if the possible water input from simultaneously operated units can exceed 1 l/min. If the maximal amount of water can exceed 1 l/min or if the waste water from several units is brought together, then the ECO II Tandem must be used, if necessary with a sufficiently dimensioned expansion container. 1 1 See illustration Installation directly into the waste water pipe of the dental units The ECO II is installed after the air/water separation 1.1 directly into the waste water pipe of the dental unit. 2 See illustration Installation after a central evacuation system Volume of waste water <1 l/min: The ECO II is installed after the central evacuation system with air/water separation (waste water outlet) into the waste water pipe. 2 3 See illustration Installation after a central evacuation system Volume of waste water >1 l/min: The ECO II Tandem is installed after the central evacuation system with air/water separation (waste water outlet) into the waste water pipe. 4 Installation in the suction line before a liquid ring pump In liquid ring systems, the ECO II and the ECO II Tandem are installed in the suction line before the liquid ring pump. Order option: If the separator is installed in the treatment room, the ECO II can be fitted in a shapely housing. 6 3

Replacement intervals Installation ECO II Practice personnel / technicians 10. Replacement intervals The maximum service life (replacement interval) of the ECO II results from the chosen installation option and the number of operators. Please mark the appropriate box! 6 The resulting exchange interval must be adhered to! The ECO II must be replaced as soon as the maximum filling level has been reached, or 1x a year even if the maximum filling level has not yet been reached. 7 Filling level A label on the ECO II collection container 7.1 shows the filling level (100%, 95%). The label enables the user to monitor the filling level. 6 Separator ECO II 1 2 No. of Max. service operators life (months) 1 12 2 6 3 9 4 6 5 5 6 4 7.1 11. Installation ECO II 8 Mounting element/wall bracket Slide the two mounting elements together as in the picture. 7 9 Screw together at the marked spots with the supplied screws and screw-nuts. For the mounting element, the following minimal space is required (H x W x D): 14.2 x 7.9 x 9 inches or 360 x 165 x 202 mm. Position mounting element on an even floor space or fix onto wall with suitable screws 9.1. 9.1 10 The readily assembled mounting element has to be fixed on a suitable place on the wall using appropriate screws 10.1. Position the device on the guiding studs of the mounting element and fasten with screws 10.2. Care must be taken that the mounting element is positioned vertically above the level of the suction machine. 8 9 11 Hose connections: 11.1 Waste water inlet: waste water from the dental unit or from the central evacuation system 11.2 Waste water outlet: cleaned waste water directly to the sewage pipe In order to guarantee a trouble-free connection of different sizes of hoses, hose adapters supplied along with the device must be inserted in the inlet and outlet openings.in any case ensure that all connections are properly secured! The waste water must be able to drain off freely into the sewage pipe! 10 10.1 11 11.1 11.2 7

Installation ECO II Tandem Technicians 12. Installation ECO II Tandem 1 IN OUT 8 2

Hose connections between ECO II / ECO II Tandem and EXCOM hybrid Technicians 13. Hose connections between ECO II / ECO II Tandem and EXCOM hybrid central evacuation systems evacuation system suction flow IN amalgam separator min. 2% water OUT min. 2% ECO II max. 15 in evacuation system suction flow IN amalgam separator min. 2% water OUT min. 2% ECO II Tandem max. 15 in 9

EXCOM hybrid A1 / A2 / A5 with ECO II amalgam separation Technicians 12. 14. EXCOM hybrid A1 / A2 / A5 evacuation systems with ECO II amalgam separation min. 2 % Model Order no. EXCOM hybrid A1 - ECO II 230 V: 02010251 - min. 2 % Model Order no. EXCOM hybrid A2 - ECO II (international) EXCOM hybrid A5 - ECO II Tandem (international) 230 V: 02010221 230 V: 02010222 400 V: 02010223 400 V: 02010224 10

Replacing the collection container Practice personnel / technicians 15. Replacing the collection container The ECO II collection container must be exchanged according to the replacement intervals as defined in the replacement interval table (cf. page 7, chapter 10). Wear protective gloves and face mask! Avoid contact with the contents of the amalgam separator! It is not possible to open the ECO II and reuse it! Every attempt to open the amalgam separator results in the malfunction of the device. Moreover, the required separation rate will no longer be achieved! 1 2 1 Remove the adapter with the tube at the waste water inlet and waste water outlet. 3.1 2 Tightly close the outlet of the full ECO II with the sealing plug (supplied with the amalgam separator). 3 Detach the screws from the bolts 3.1 and take out the full amalgam separator by lifting it off upwards. 4 Position the full amalgam separator horizontally onto an even surface, make sure that the inlet opening is pointing upwards! Cut open the disinfection pouch for final disinfection (supplied with new amalgam separator) at one corner and pour its content into the inlet opening of the full amalgam separator. 3 4 5 Afterwards also tightly close the inlet opening with the sealing plug. 6 Put the amalgam separator into the plastic liner (supplied with the new amalgam separator), place it into the styrofoam shells and then into the cardboard box. 5 6 7 Install the new amalgam separator 7.1 and secure it with the bolts and screws. 8 Reconnect the adapter with the tube to the IN and OUT openings. 7.1 Check inlet and outlet of the ECO II for tightness! Suck in a large quantity of water (at least 0.5 gal or 2 l) to check the system for leakages. If leakages are found, check the hose connections. 7 8 11

Disposal of the full collection container Practice personnel / technicians 16. Disposal of the full collection container Wear protective gloves and face mask! Avoid contact with the contents of the container! For technical and hygienic reasons the collection container is designed for single use. The reuse of a used container can lead to malfunction and violates the warranty regulations! The disposal of the full amalgam separator will be handled by PURE WATER DEVELOPMENT. 9 Certificates of recycling need to be stored according to national law. 9 See illustration Place the properly sealed amalgam separator into the two styrofoam shells. 10 See illustration Put the amalgam separator in the styrofoam shells into the transport box and close it. 11 See illustration Place the appropriate return label onto the transport box for recycling at PURE WATER DEVELOPMENT (more information on www.ecotwo.com). 10 12 11 www.youtube.com/user/purewaterdevelopment

Maintenance and cleaning Practice personnel / technicians 17. Maintenance and cleaning 1 See illustration Shortly operate the rinsing basin after every treatment! 2 See illustration Suck off some water with each of the suction tubes after every treatment. 3 See illustration: To ensure optimal functioning of the device and high material compatibility, use GREEN&CLEAN M2 for maintenance and cleaning of the ECO II. GREEN&CLEAN M2 should be used before longer periods of downtimes of the dental unit (e.g. lunch break, end of the working day or holidays). 1 4 See illustration The spittoon bowl should also be rinsed with GREEN&CLEAN M2 twice a day. 2 3 www.youtube.com/user/metasysmedizintech 4 13

Pure Water Development LLC 5001 SW 74th Court, Suite 206 Miami, FL-33155 Phone: 305 663 2989 Fax: 305 662 7479 E-mail: pwd@metasys.com www.ecotwo.com 11.2014 ZK-55.221/08 70100325 Subject to printing and setting errors! For more information about PURE WATER DEVELOPMENT LLC, please visit www.ecotwo.com