Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Similar documents
Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Zareba Sensepoint Pro

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Zareba Metro Gas Detector

Sieger Apex. Flexibility that meets your requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Zareba Unipoint controller

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

OLC(T) 100 FIXED GAS DETECTOR

Operating Instructions

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Neotronics Impact & Impact Pro

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Operating Instructions

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

GAS DETECTOR ST400EC PART.NO

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

3M Oldham OLCT 100. Description. Fixed Gas Detector

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

SIL 2. Ultima X Series Gas Monitors CERTIFIED

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sieger fixed gas detection. Fixed protection from hazardous gas

Transmitters/Sensors. OLCT Series

Technical Manual. Zareba Sensepoint Gas Detectors

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

APPLICATION DATA SHEET

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

ESD3000 ESD200 Combustible / Toxic Gas Detector

XT Series Personal Gas Detector. Operating Instructions

ESD500. ESD500 Combustible / Toxic Gas Detector

Searchpoint Optima Plus

Operating Instructions and Maintenance Manual

Toxic Gas Detection. Model F12. Toxic Gas Detection

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Operating Instructions

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Life Safety Network. Intelligent solutions for advanced requirements

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

SIMRAD GD10 IR GAS DETECTOR

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

XNX Universal Transmitter

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

ALTAIR 5X Multigas Detector Product Specification

P R O D U C T D ATA S H E E T

Lumidor portable gas detection. Portable protection from hazardous gas

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

ULTIMA X5000. MSAX5000.com

P R O D U C T D ATA S H E E T

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Safe Operation Manual. Honeywell IQ Force Gas Detector

Neotronics portable gas detection. Portable protection from hazardous gas

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

XNX Universal Transmitter

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

VQ500 Series Combustible Gas Detector Elements

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

IGD.CO.UK

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Danfoss gas detection unit Type GD Heavy Duty

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

P R O D U C T D ATA S H E E T

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SERIES 47K GAS SENSOR

SIMRAD GD10PE IR GAS DETECTOR

Frequently Asked Questions

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Sensepoint XCL Fixed Gas Detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Transcription:

Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs.

Sieger Sensepoint Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications Proven Sensor Technology Surecell TM electrochemical sensors Poison resistant catalytic bead Fast and reliable Typical 2 to 5 years operational life ATEX Certified Complies with the latest European standards Hazardous area approval AND performance IP 65/66 for use in harsh environments Easy to Use Factory set operation Simple to replace Minimal training required Range of Accessories Weatherproof cap Flow adaptor Duct mounting kit Collecting cone The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Exd or Exe approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics controllers or 3rd party DCS/PLC systems. Both flammable and toxic versions are certified to the latest European ATEX safety and performance standards. The flammable detector is available in either %LEL or PPM detection range versions and provides an industry standard mv bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one. The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Exd, while front end Intrinsic Safety (IS design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of sticky gases such as Chlorine and Ammonia. Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Installation Details Dimensions Flammable %LEL or PPM Version Toxic or Oxygen Version Sensepoint flammable and toxic gas detectors are installed using suitable Exd or Exe junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences. The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Installation Details Electrical Connections Typical Terminal Connections Flammable %LEL Version Brown (S Blue (NS White (01 +VE -VE Signal To Controller 3 Wire mv Bridge Circuit Toxic or Oxygen Version Blue (- Cable Screen +VE Signal To Controller Red (+ Screen 2 Wire 4-20mA (Sink Flammable PPM Version Red (S Blue (NS Green (01 Cable Screen Screen +VE -VE Signal To Controller 3 Wire mv Bridge Circuit

Technical Specification Gas & Range Flammable 0-100%LEL Flammable PPM (Typically 0-10%LEL Hydrogen Sulfide (H 2 S 20/ 50/100ppm Carbon Monoxide (CO 100/200/500ppm Ammonia (NH 3 50/ 1000ppm Chlorine (Cl 2 5/15ppm Oxygen (O 2 25% V/V Hydrogen (H 2 1000/ 10000ppm Sulfur Dioxide (SO 2 15/50ppm Nitric Oxide (NO 100ppm Nitrogen Dioxide (NO 2 10ppm Operating Temp. -55 to +80 C 1-30 to +65 C. -25 to +50 C. -20 to +50 C. -20 to +40 C. -20 to +50 C. -15 to +40 C. Operating Humidity Continuous: 20 to 90% RH (non-condensing. Intermittent: 10 to 99% RH (non-condensing. Storage Conditions 0 to 25 C; 30 to 70% RH. 0 to 25 C; 30 to 70% RH. Operating Pressure 90 to 110kPa. Warm-up Time < 10 minutes. < 20 minutes. < 3 minutes. < 5 minutes. < 3 minutes. 12 hours. 1 hour. Response Time T20 < 6 secs. < 5 secs. < 10 secs. < 3 secs. < 3 secs. < 15 secs. T50 < 5 secs. < 15 secs. < 12 secs. < 10 secs. < 20 secs. < 5 secs. < 10 secs. < 10 secs. < 5 secs. < 30 secs. T90 < 10 secs. < 40 secs. < 30 secs. < 65 secs. < 105 secs. < 10 secs. < 45 secs. < 90 secs. < 30 secs. < 60 secs. Supply 200mA; 0.7W maximum. 18 to 30V dc; 0.9W maximum. Signal Output mv bridge. Loop powered 4 to 20mA. Linearity < 5% fsd or ±10% of reading < 5% fsd. Operating Life 5 years (typical. 2 years (typical. 18 months (typical. 1 year (typical. 18 months (typical. Storage Life Typically, over 5 years when in original sealed packaging. 6 months. Stability (zero with time* < ±3% fsd/yr. < ±2% fsd/yr. with temperature** < ±1% fsd 2 < ±3% fsd. < ±5% fsd. < ±6% fsd. < ±2% fsd. < ±2% fsd. < ±5% fsd. with humidity < ±1% fsd. < ±10% fsd. < ±2% fsd. < ±10% fsd. < ±2% fsd. < ±2% fsd. < ±10% fsd. Stability (span with time* < ±3% fsd/yr. < ±2% fsd/yr. < ±4% fsd/yr. < ±20% fsd/yr. < 10% fsd/yr. < ±20% fsd/yr. < ±2% fsd/yr. with temperature*** < ±3% fsd < ±8% fsd. < ±25% fsd. < ±20% fsd. < ±20% fsd. < 40% fsd. < ±10% fsd. < ±60% fsd. < ±15% fsd. < ±25% fsd. with humidity < ±2% fsd. < ±10% fsd. < ±2% fsd. < ±10% fsd. < ±2% fsd. < ±1% fsd. < ±2% fsd. < ±10% fsd. Weight 190g. 185g. 205g. 185g. Construc. Materials Polyphenylene sulfide (PPS I.P. (NEMA Rating IP65 (standard, IP67 (with weather protection fitted Certification Details (ATEX Other Certifications Applicable Standards Ex II 2 GD EEx d IIC T6 (Tamb = -55 C to +55 C T5 (Tamb = -55 C to +70 C 3 BAS98ATEX2156X/4 SIRA03ATEX1116X (Performance Ex II 2 GD EEx dia IIC T4 (Tamb = -55 C to +65 C BAS90ATEX2157X/5 Australian: SAA, Russian: GOST This product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN50054/57, Toxic to EN445544 (H 2 S only NOTES 1 High temp range version available -55 to +150 C See separate datasheet DS0303 2 Over temp range -20 to +55 C 3 LEL version T4-55 to +80 C, T3-55 to +150 C * = % of range (fsd per year ** Over operating temperature range *** = % of applied concentration

Ordering Information Accessories 00780-A-0100 Term Hsg Bartec DE1155 With Continuity Plate 1 X 25mm 3 X 20mm Entries ATEX Approved 00780-A-0160 Right Angle Mounting Bracket For Ceiling Mounting 02000-A-1635 Series 2000 Weather Housing Use With Toxic Sensor 02000-A-1640 Series 2000 Weather Housing Use With Flammable Sensor 02000-A-1642 Series 2000 Collecting Cone Use With Flammable Sensor 02000-A-1645 Series 2000 Calibration Flow Housing Assembly (Flam & Toxic 02000-A-3120 Series 2000 Flow Housing Assembly Plastic 2106B1110 Catalytic Bridge To 4-20mA Converter 2106B2114 Toxic Calibration Kit including calibration cover, removal tool, potentiometer adjustment tool 2106D2055 M36/M40 thread adaptor 225-262-138 Cable gland and caps, 20mm, Nylon Spares 2106B1545 2106B1546 2106B1547 2106B1548 2106B1549 2106B1594 2106B1595 2106B1596 2106B1597 2106B1598 2106B1599 Calibration Equipment Find out more www.honeywellanalytics.com Customer business centre O 2 Electrochemical Cell Exchange Kit SO 2 Electrochemical Cell Exchange Kit Cl 2 Electrochemical Cell Exchange Kit CO Electrochemical Cell Exchange Kit H 2 S Electrochemical Cell Exchange Kit NO Electrochemical Cell Exchange Kit NH 3 0-1000 ppm Electrochemical Cell Exchange Kit NH 3 0-50 ppm Electrochemical Cell Exchange Kit H 2 0-1000 ppm Electrochemical Cell Exchange Kit H 2 0-10000 ppm Electrochemical Exchange Kit NO 2 0-10 ppm Electrochemical Exchange Kit Contact your local Honeywell Analytics representative for details of suitable calibration equipment Europe and the rest of the world Honeywell Analytics AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (044 943 4300 Fax: +41 (044 943 4398 sales@zelana.co.uk Sensepoint Combustible 2106B1200 Sensepoint 0-100% LEL Flammable Sensor M20 2106B1201 Sensepoint 0-100% LEL Flammable Sensor M25 2106B1202 Sensepoint 0-100% LEL Flammable Sensor M26 2106B1203 Sensepoint 0-100% LEL Flammable Sensor M26 (VQ1AB pellistor 2106B1204 Sensepoint 0-100% LEL Flammable Sensor 3/4NPT 2106B1205 Sensepoint ppm (0-10% LEL Flammable Sensor M20 2106B1209 Sensepoint ppm (0-10%LEL Flammable Sensor 3/4NPT Sensepoint Toxic 2106B1400 Sensepoint Hydrogen Sulfide (H 2 S 0-20 ppm Toxic Sensor M20 2106B1401 Sensepoint Hydrogen Sulfide (H 2 S 0-50 ppm Toxic Sensor M20 2106B1402 Sensepoint Hydrogen Sulfide (H 2 S 0-100 ppm Toxic Sensor M20 2106B1700 Sensepoint Hydrogen Sulfide (H 2 S 0-20 ppm Toxic Sensor 3/4NPT 2106B1701 Sensepoint Hydrogen Sulfide (H 2 S 0-50 ppm Toxic Sensor 3/4NPT 2106B1702 Sensepoint Hydrogen Sulfide (H 2 S 0-20 ppm Toxic Sensor 3/4NPT 2106B1405 Sensepoint Carbon Monoxide (CO 0-100 ppm Toxic Sensor M20 2106B1406 Sensepoint Carbon Monoxide (CO 0-200 ppm Toxic Sensor M20 2106B1407 Sensepoint Carbon Monoxide (CO 0-500 ppm Toxic Sensor M20 2106B1705 Sensepoint Carbon Monoxide (CO 0-100 ppm Toxic Sensor 3/4NPT 2106B1706 Sensepoint Carbon Monoxide (CO 0-200 ppm Toxic Sensor 3/4NPT 2106B1707 Sensepoint Carbon Monoxide (CO 0-500 ppm Toxic Sensor 3/4NPT 2106B1410 Sensepoint Chlorine (Cl 2 0-5 ppm Toxic Sensor M20 2106B1411 Sensepoint Chlorine (Cl 2 0-15 ppm Toxic Sensor M20 2106B1711 Sensepoint Chlorine (Cl 2 0-15 ppm Toxic Sensor 3/4NPT 2106B1413 Sensepoint Ammonia (NH 3 0-50 ppm Toxic Sensor M20 2106B1414 Sensepoint Ammonia (NH 3 0-1000 ppm Toxic Sensor M20 2106B1415 Sensepoint Ammonia (NH 3 0-100 ppm Toxic Sensor M20 2106B1713 Sensepoint Ammonia (NH 3 0-50 ppm Toxic Sensor 3/4NPT 2106B1714 Sensepoint Ammonia (NH 3 0-1000 ppm Toxic Sensor 3/4NPT 2106B1715 Sensepoint Ammonia (NH 3 0-100 ppm Toxic Sensor 3/4NPT 2106B1416 Sensepoint Hydrogen (H 2 0-1000 ppm Toxic Sensor M20 2106B1417 Sensepoint Hydrogen (H 2 0-10000 ppm Toxic Sensor M20 2106B1716 Sensepoint Hydrogen (H 2 0-1000 ppm Toxic Sensor 3/4NPT 2106B1717 Sensepoint Hydrogen (H 2 0-10000 ppm Toxic Sensor 3/4NPT 2106B1418 Sensepoint Nitric Oxide (NO 0-100 ppm Toxic Sensor M20 2106B1718 Sensepoint Nitric Oxide (NO 0-100 ppm Toxic Sensor 3/4NPT 2106B1420 Sensepoint Sulfur Dioxide (SO 2 0-15 ppm Toxic Sensor M20 2106B1421 Sensepoint Sulfur Dioxide (SO 2 0-50 ppm Toxic Sensor M20 2106B1720 Sensepoint Sulfur Dioxide (SO 2 0-15 ppm Toxic Sensor 3/4NPT 2106B1721 Sensepoint Sulfur Dioxide (SO 2 0-50 ppm Toxic Sensor 3/4NPT 2106B1422 Sensepoint Nitrogen Dioxide (NO 2 0-10 ppm Toxic Sensor M20 2106B1722 Sensepoint Nitrogen Dioxide (NO 2 0-10 ppm Toxic Sensor 3/4NPT 2106B1430 Sensepoint Oxygen (O 2 25% V/V Toxic Sensor M20 2106B1730 Sensepoint Oxygen (O 2 25% V/V Toxic Sensor 3/4NPT Customer business center Americas Honeywell Analytics Distribution, Inc. 400 Sawgrass Corporate Pkwy Suite 100 Sunrise, FL 33325 USA Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 sales@zelana.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. 2005 Honeywell Analytics H_Sensepoint_DS0326_V1 09/05 2005 Honeywell Analytics 11577