Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Similar documents
Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Zareba Sensepoint Pro

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Fixed-Point Industrial Gas Detection

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Operating Instructions

Fixed-Point Industrial Gas Detection

XNX Universal Transmitter

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Zareba Metro Gas Detector

EC FX NH3. A new and improved approach to ammonia gas detection

Life Safety Network. Intelligent solutions for advanced requirements

Technical Manual. Zareba Sensepoint Gas Detectors

Operating Instructions and Maintenance Manual

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Searchpoint Optima Plus

SPM Flex Chemcassette Tape-Based Gas Detector

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Zareba Unipoint controller

Sensepoint XCL Fixed Gas Detector

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Honeywell Analytics. Order List BW Clip & IntelliDoX

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

System 57. An advanced World of intelligent gas detection system management

Sieger Apex. Flexibility that meets your requirements

System 57. An advanced world of intelligent gas detection system management

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

3M Oldham OLCT 100. Description. Fixed Gas Detector

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

XNX Universal Transmitter

Product Specifications

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

SPM Flex Chemcassette Tape-Based Gas Detector

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Zareba System Overview

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Transmitters/Sensors. OLCT Series

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Touchpoint Pro Flexible Gas Control System

Neotronics Impact & Impact Pro

Sieger fixed gas detection. Fixed protection from hazardous gas

GAS DETECTOR ST400EC PART.NO

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Operating Instructions

MeshGuard and MeshGuard Gamma

Operating Instructions

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

MeshGuard and MeshGuard Gamma

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Searchpoint Optima Plus

ULTIMA X5000. MSAX5000.com

Gas Detection. Touchpoint Plus. A whole new control experience

CO and NO 2 Monitoring Systems for Parking Structures

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

ALTAIR 5X Multigas Detector Product Specification

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

EXAMPLES OF HOW TO ORDER

Dräger Polytron 8200 Stationary gas detector (CatEx)

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger Polytron 5720 IR Toxic Gas Detection

XNX Universal Transmitter

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger PIR 3000 Detection of flammable gases and vapours

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

APPLICATION DATA SHEET

ALTAIR 5X Multigas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Transcription:

Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sensepoint One-Stop Shop Flammable, toxic and oxygen versions available Suitable for indoor or outdoor use IP65 as standard Proven Sensor Technology Surecell TM electrochemical sensors Poison resistant catalytic bead Fast and reliable Typical 2 to 5 years operational life ATEX Certified Complies with the latest European standards Hazardous area approval AND performance Can be used for uncertified applications Easy to Use Factory set operation Simple to replace Minimal training required Friendly Installation Universal junction box One box, three entries Metric and NPT compatability Includes earth continuity plate for added RFI protection Range of Accessories Weather Housing (IP66) Flow adaptor Duct mounting kit Collecting cone The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs, in or out of doors and even in potentially explosive atmospheres. Supplied with a pre-wired junction box, a detector can be installed using conduit or armored cable and glands depending on individual site standards. Sensepoint flammable and toxic gas detectors are designed for use in potentially explosive atmospheres and allow for hands free, unhindered access, to terminals via the hinged lid of the junction box. Installation should follow national guidelines using suitably approved armored cable and glands or conduit. Supplied with earth continuity plate for improved immunity to RFI the junction box offers the installer a choice of 1/2, 3/4 and M20 connection via conduit or armored cable and Exe certified cable glands. Terminals are suitable for use with screened 0.5mm 2 (20AWG) to 2.5mm 2 (14AWG) cross sectional area cable, as needed to ensure minimum operating voltage at the detector, depending upon installed cable length. Contact Honeywell Analytics for details.

Installation Details Dimensions Sensepoint flammable and toxic gas detectors allow for hands free, unhindered access, to terminals via the hinged lid of the junction box. 156.0mm / 6.1" 102.0mm / 4.0" 76.5mm / 3.0" 34.0mm / 1.3" Supplied with earth continuity plate for improved immunity to RFI the junction box offers the installer a choice of 1/2 NPT, 3/4 NPT and M20 connection via conduit or steel wire armored cable and Exe certified cable glands. Sensepoint flammable, toxic and oxygen gas detectors are designed for direct connection with the Touchpoint and Unipoint range of controllers as well as other Honeywell Analytics controllers. Contact Honeywell Analytics for details. 75.0mm / 3.0" 102mm / 4.0" 202.0mm / 8.0" ø 60.0mm / 2.4" Flammable Version Toxic & Oxygen Version Terminal Arrangement Terminal Arrangement Electrical Connections Electrical Connections Active Non-active 100 ohm 3 Wire mv Bridge Circuit 2 Wire 4-20mA (Sink)

Technical Summary General Specification Use Detectable Gases Low cost, fixed point gas detector for the protection of personnel and plant from flammable, toxic and oxygen gas hazards Gas Measuring Range Operating Temperature* Ident Name 1# 2 3 Min Max F Flammable 0-100% LEL -40 C / -40 F 50 C / 122 F O Oxygen 0-25% VOL -15 C / 5 F 40 C / 104 F C Carbon Monoxide + 0-200ppm 0-500ppm -20 C / -4 F 50 C / 122 F H Hydrogen Sulfide + 0-50ppm 0-20ppm 0-100ppm -25 C / -13 F 50 C / 122 F G Hydrogen 0-1000ppm -5 C / 23 F 40 C / 104 F L Chlorine 0-5ppm 0-15ppm -20 C / -4 F 50 C / 122 F S Sulfur Dioxide 0-15ppm 0-50ppm -15 C / 5 F 40 C / 104 F N Nitrogen Dioxide 0-10ppm -15 C / 5 F 40 C / 104 F A Ammonia 0-50ppm 0-1000ppm -20 C / -4 F 40 o C / 104 F + SureCell TM Sensing Technology # Standard range *Check certified temperature Construction Electrical Flammable (0-100%LEL) Toxic & Oxygen Junction Box 3 wire mv bridge 2 wire loop powered 4-20mA Earth continuity plate 2.9-3.5V, 0.7W (plus screen) BK4 terminal block (4 way) 200mA constant current 16-30Vdc, O.9W 4 x 0.5mm 2 (20AWG) to 2.5mm 2 (14AWG) 1 x M20, 1 x 3/4" NPT, 1x1/2" NPT Material Polyphenylene Sulfide (PPS) Polyphenylene Sulfide (PPS) Fire retardant GFP Weight 190g 185g (205g oxygen) 600g Certification Ex II 2 G D EExd IIC Ex II 2 G D EExd ia IIC Ex II 2 G D EExe II T6 T85 Deg C T4 T135 Deg C T6 T85 Deg C T amb = -55 C to +55 C T amb = -55 C to +65 C T amb = -40 C to +50 C BAS98ATEX2156X BAS98ATEX2157X SIRA04ATEX3018 SIRA03ATEX1116X (Performance) Applicable Standards Environmental IP Rating Operating Temperature Operating Humidity Range Operating Pressure Storage Conditions This product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN50054, Toxic to EN445544 (H 2 S only) IP65 standard, IP66 with weather protection in accordance with EN60529:1992 Dependent upon gas type and certification Continuous: 20-90%RH (non condensing), Intermittent: 10-99%RH (non condensing) 90-110kPa Instrument -40 C to +50 C (-40 F to +122 F) *Oxygen detection products must only be used to detect oxygen depletion in air

Ordering Information Ordering Information e.g. SPSTAX H 1 = SPSTXXH1 GAS TYPE F Flammable O Oxygen C Carbon Monoxide H Hydrogen Sulfide G Hydrogen L Chlorine S Sulfur Dioxide N Nitrogen Dioxide RANGE } 1 Refer to 2 Detectable Gases 3 Table Above Standard Supply Each detector is supplied complete with junction box, multiple cable entries, earth continuity plate, hinged lid and instruction leaflet, all sealed in a plastic bag inside a shipping carton Shipping Details Shipping carton dimensions: L160mm (6.3 ) x W215mm (8.5 ) x 80mm (3.1 ) Approximate weight: 800g Optional Accessories 02000-A-1645 Calibration gas flow housing (for flammable & toxic) 00780-A-0160 Right angle mounting bracket for ceiling mounting 02000-A-1640 Weather Housing for use with flammable detector including remote gassing nozzle 02000-A-1635 Weather Housing for use with toxic/oxygen detector including remote gassing nozzle 02000-A-1642 Collecting cone for use with flammable detector Calibration Equipment Contact Honeywell Analytics Representative

Honeywell Analytics Lines of Business Commercial Gas detection from standalone units to fully engineered, multi-point systems, all offering cost-effective regulatory compliance» Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies» Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial Portables Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments» Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: 847.955.8200 Toll-free: 800.538.0363 Fax: 847.955.8210 detectgas@honeywell.com Technical Services ha.service@honeywell.com www.honeywell.com High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion» Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response Europe, Middle East, Africa Life Safety Distribution AG Weiherallee 11a CH-8610 Uster Switzerland Tel: +41 (0)44.943.4300 Fax: +41 (0)44.943.4398 gasdetection@honeywell.com Technical Services 24/7 global network includes post-sales service and Systems Integration teams» Emergency call out, service contracts, on/off-site repair, training and commissioning» Complete range of spares, consumables and accessories Asia Pacific Honeywell Analytics, Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea Tel: +82 (0)2.2025.0307 Fax: +82 (0)2.2025.0329 analytics.ap@honeywell.com Please Note: While ever effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Sensepoint_DS0326_V3 6/10 2010 Honeywell Analytics HWA6039