RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Similar documents
OHIO UNIVERSITY RADIATION SAFETY REVIEW

HEALTH AND SAFETY MANUAL

California State University Bakersfield Radiation Safety Program Revised November 2017

University of Maryland Baltimore. Radiation Safety Procedure

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Department of State Health Services

X-Ray Protection Program

AGENDA UNIVERSITY OF NEW HAMPSHIRE RADIATION SAFETY COMMITTEE 4th Quarter Meeting 2016 December 8, :30-2:30 pm Rudman G04

C-NRPP Quality Assurance Guidance for Radon Test Devices

Radiation Safety Manual

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

University of Maryland Baltimore Environmental Health and Safety updated 1/3/2018 RADIOACTIVE Lab Inspection Common Findings and Corrective Actions

Minor Change Office of Radiological Safety Number: Revision 00 By: Georgia Institute of Technology. Approved 04/21/2016 Date: / / Page 1 of 6

Portable Survey Instruments NISP-RP-01

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Radiation Safety Manual

ALPHA Radiation Safety Manual

Identify the following features and specifications for the ESP1

HANDBOOK FOR RADIATION SAFETY

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Application Note. Application Note for BAYEX

Carnegie Mellon University Radiation Safety Committee

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

UCONN HEALTH OFFICE OF RADIATION SAFETY PROCEDURES GOVERNING PROCUREMENT, USE AND DISPOSAL OF RADIOACTIVE MATERIALS

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Bethel School District Radon Testing Plan

AUBURN UNIVERSITY X-RAY SAFETY STANDARD OPERATING PROCEDURES

Florida International University. Biosafety Cabinet Program

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

The RSO will submit a copy of the revised manual to the RSC for approval when the revised manual has substantial changes.

Analytical X-Ray Safety Program

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

Nuclear Associates

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CHAPTER 3 RADIATION PRODUCING DEVICES I. AUTHORIZATION TO USE RADIATION PRODUCING DEVICES

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

Minnesota Rules, Chapter 4732 X-Ray Revision

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

SOP SF SOP for LN2 Freezers

Minnesota Rules, Chapter 4732 X-Ray Revision

Radiation Emitting Devices Research X-ray Safety Program

Ranger EXP RADIATION A L E R T

RADIATION PRODUCING MACHINE SAFETY MANUAL

Radioactive Contamination Monitor

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Contamination Meter Users Manual

CHAPTER 240. RADON CERTIFICATION

INTERNATIONAL STANDARD

Radiation Training for Ancillary Personnel. Introduction


Measurement Devices. Topic 5 - Audio 56

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

Procedures for Preparing and Receiving PUF Canisters and Filters

Radiation Alert Frisker INTERNATIONAL

Radiation Monitoring Equipment

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

PRELIMIN INTERNATIONAL

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

RADIATION PROTECTION SERVICE

NCDOI OSFM Evaluation Services

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

Introduction...1 Specifications... 1 Limitations... 1

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

RAM GENE / RAM GENE-1

LABORATORY INSPECTION CHECKLIST

Radiation Safety Guidelines for Non-Users

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers

Appendix C X-Ray Diffraction User s Guide and Approval Form

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ]

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Countering Nuclear Smuggling in Lithuania: Detection Mr Albinas Mastauskas Director, Radiation Protection Centre LITHUANIA

Courtney Sulentic, Ph.D., Chairperson, Radiation Safety Committee*

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Corporate Standard Radiation Safety HB#

Radon Detection Specialists, Inc.

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

Transcription:

RADIATION PROCEDURES MANUAL Procedure Cover Sheet Procedure Title: Sealed Source Leak Tests Procedure Number: TSO-08-04-REV 1 Effective Date: September 1, 2008 Approved By: Date: 19 May, 2009 Technical Safety Office Director Page 1 of 6

Procedure #: TSO-08-04-REV 1 Procedure Title: Sealed Source Leak Tests Approval Date: May 19, 2009 Effective Date: September 1, 2008 A. INTRODUCTION The ISU Broad-scope radioactive material license requires that sealed sources of radioactive material be tested for leakage at regular intervals to verify the integrity of the source containment and, in the unlikely event of failure, to detect the escape of radioactive material before serious contamination of facilities, equipment, or personnel occurs. Leak tests are performed by the Technical Safety Office on a semi-annual basis (June and December). Sealed sources do not need to be leak checked only if 1) they are composed of only 3 H or a radioactive gas, 2) they have a half-life less than or equal to 30 days, 3) they contain less than 100 µci of beta and/or gamma emitting material, or 4) they contain less than 10 µci of alpha emitting material. A leak test shall be capable of detecting the presence of 0.005 µci of radioactive material on the swipe paper. If swipe analysis reveals the presence of 0.005 µci or more of removable contamination, a report shall be filed with the NRC in accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated, disposed of or repaired. B. PURPOSE This procedure specifies criteria and methods for performing leak tests of sealed sources in accordance with regulatory requirements and ISU Broadscope license conditions. C. REQUIRED MATERIAL(S) Previous leak test inventory worksheet Transportation forms for the previous 6 months Radionuclide package arrival reports for the previous 6 months Contamination swipes and related equipment Ring badge Page 2 of 6

D. PROCEDURE Leak tests at ISU consist of 4 steps: preparation, taking contamination swipes, swipe analysis and completing the worksheet. Preparation: 1. Open the previous leak test inventory worksheet found in the Leak Tests folder of tsoshare. 2. Save the inventory worksheet under a new name using the format: Leaks + first 3 letters of month + last 2 digits of year. 3. Ensure that the information regarding the liquid scintillation counter serial number and efficiency at the bottom of the worksheet is correct. 4. Delete the data in the last 4 columns of the spreadsheet. These columns will be filled with the new swipe analysis information once the sealed sources have been tested. 5. Look through the transportation records for the previous 6 months to determine whether any of the sources have been moved to a different location. Update the location column accordingly. 6. Look through the Radionuclide Package Arrival Reports for the previous 6 months. Add any new sources to the spreadsheet that meet the leak test criteria. Be sure to include serial numbers, dates, activities etc. Contamination Swipes: 1. Gather the necessary items for taking contamination swipes. These items include gloves, swipe papers, Ziploc bags, a permanent marker, etc. 2. Obtain a ring badge from dosimetry. Ring badges should be worn inside the gloves with the serial number facing toward the palm. 3. Prepare and label a swipe paper for each of the sealed sources to be tested when you arrive at the source storage location. Include the radionuclide, serial number, current date, and location. 4. Directly swipe the source when possible. If the source is housed in shrinkwrap or another type of closed container, swipe the outside of the container rather than the source itself. Sealed sources with activities in Page 3 of 6

the microcurie range can be safely swiped directly. Use forceps for sources in the millicurie range to minimize exposure to the hands. 5. Bag the finished swipes and return them to the TSO lab for analysis. 6. Repeat this procedure for all of the locations where sealed sources on the leak test spreadsheet are stored. Swipe Analysis: Leak test analysis instrumentation must be capable of detecting 5 nanocuries of activity on the outside of the source housing. A non-leaking source will exhibit background activity levels, so levels above background will indicate the presence of external contamination. For this reason, leak test swipes are analyzed in the TSO Wallace 1410 liquid scintillation counter (currently capable of detecting about 10 picocuries of activity). The procedure for leak test swipe LSC analysis is the same as the procedure for contamination swipe LSC analysis. Leak Test Worksheet: 1. Record the background counts (cpm) from the LSC swipe analysis worksheet in the Bkg column of the leak test worksheet for each source. Note: each LSC batch has a different background so it is important to keep track of the batch to which each source belongs. 2. Enter the gross counts (cpm) for each source into the Gross column. Gross counts are in the CPM column on the LSC swipe analysis worksheet. 3. The DPM column of the leak test worksheet is automatically calculated by a formula. It is important to ensure that the LSC efficiency entered into the formula (the denominator value) is current. 4. The activity is also automatically calculated with a formula in the nci column. Any negative values may be changed to zero. 5. Verify that the formulas and values are correct. 6. Check for high activities. If the activity of a source s test exceeds 5 nanocuries, the source must be safely contained, taken out of service, and assumed defective. A source that shows evidence of leaking must be reported to the NRC within 5 days. Page 4 of 6

7. Save the worksheet into the tsoshare Leak Tests folder. 8. Print out a copy of the leak test worksheet. 9. Make a cover sheet for the leak tests using Word. The cover sheet should include the month and year, your name and a line for the RSO s signature. A cover sheet template is available in the tsoshare Leak Tests folder. 10. Bring the leak tests to the RSO for review. 11. Create a file folder for the leak test worksheet and file the signed document in the appropriate cabinet of TSO office room 101A. Note: It is important to always verify that the serial number of the source being leak tested is the same as that on the leak test worksheet. There are many sealed sources for each radionuclide at ISU, so it is easy to confuse sources if serial numbers are not carefully corroborated before swipes are taken. REFERENCES 10 CFR 30 Page 5 of 6

Procedure #: TSO-08-04-REV 1 Procedure Title: Sealed Source Leak Tests Approval Date: May 19, 2009 Effective Date: September 1, 2008 REVISION TRACKER Revision 1 September 1, 2008 Original Procedure Page 6 of 6