VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)

Similar documents
Fire & Life Safety Requirements For Fire Department Access and Water Supplies

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

C I T Y O F B A N N I N G BANNING FIRE SERVICES 3900 W. WILSON STREET (951) PHONE (951) FAX

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

FIRE SERVICE FEATURES

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT


Drexel Heights Fire District 2012 International Fire Code Amendments

FIRE PREVENTION STANDARDS

CHAPTER 6 FIRE SAFETY STANDARDS. Adopted: September 22, Revised: August 7, April 1, May 15, June 1, 2003

TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

FIRE CODE APPLICATION GUIDE FOR DEVELOPMENT IN UNINCORPORATED MULTNOMAH COUNTY

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

ICC CODE CORNER 2015 International Fire Code

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Site Plans. Fire Code Requirements

FIRE PLAN CHECK FORM/CORRECTION List for Single Family Residences, Duplexes, and Garages

CCCFPD RESIDENTIAL BUILDING REQUIREMENTS

Fire District Dwelling Construction Requirements

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

SECTION POLICY MANUAL

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

APPLICATION FOR Large Family Day Care Permit

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE PLAN CHECK CORRECTION List for Single Family Residences, Duplexes, and Garages

Fire Department Access and Water Supply

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

FIRE SERVICE FEATURES

ORDINANCE NO WHEREAS, the WSBCC has recently adopted new editions of several of such International codes; and

CITY OF CHESAPEAKE PUBLIC FACILITIES MANUAL CHAPTER XIII FIRE PROTECTION

Mobile Fire Rescue Department Bureau of Fire Prevention

Construction and Development Guide

City of Vista Fire Department

ORDINANCE NO

VIOLET TOWNSHIP ZONING & BUILDING DEPARTMENT Rustic Drive Pickerington, Ohio (614) Fax (614)

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up)

FIRE SAFE STANDARDS ORDINANCE No. 5905

Residential Based Care Facility Guidelines

Level I Chapter 1 Worksheet

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

RED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information

FIRE PREVENTION CODE

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Construction and Development Guide

We have reviewed the proposed concept plans for Beehive Homes and have the following comments:

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

For additional information regarding R-3.1 residential care facilities please contact (951)

FIRE APPARATUS ACCESS

Chapter 2: Identification, water and access

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Elk Creek Fire Protection District

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Residential-based Care Facility R-4 Guideline

Rental Housing Inspection Guide

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Contractor Information Packet. North County Fire Authority. 10 Wembley Drive Daly City, CA (650)

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Title 14 Fire Code. (Ord. 2426, Amended, 06/22/2009; Ord. 2407, Amended, 08/11/2008; Ord. 2266, Add, 02/28/2005)

DRIVEWAY LOCATION APPROVAL RULES AND REGULATIONS

Large Family Daycare Guideline

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

CITY OF SIMI VALLEY MEMORANDUM

ORDINANCE NO WHEREAS, the WSBCC has recently adopted new editions of several of such International codes; and

OXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA (805) Fax (805)

Business Fire Inspection. City of Guadalupe

CAMP VERDE FIRE DISTRICT

APPENDIX X. Contents:

Certificate of Occupancy Application

HAWAII ADMINISTRATIVE RULES TITLE 12 DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS SUBTITLE 7 BOARDS CHAPTER 45.1 STATE FIRE COUNCIL STATE FIRE CODE

COMMUNITY RISK REDUCTION BUREAU MANUAL TABLE OF CONTENTS EFFECTIVE: APRIL 1, 2016 AUTHORIZED: R. Pearce

CITY OF VACAVILLE PLANNING COMMISSION Agenda Item No. G.1 STAFF REPORT November 15, Staff Contact: Christina Corsello (707)

New Construction Fire Inspection Process

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

Construction & Development Procedures Guide

Apartment Fire & Safety Inspection. City of Guadalupe

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Transcription:

VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California 95688 (707) 447-2252 Requirements for new construction within the boundaries of the Vacaville Fire Protection District include, but are not limited to, the following: 1. All construction shall be sprinklered in accordance with the National Fire Protection Association Standards. A. In all existing buildings/structures when a change in occupancy classification or use occurs, or when any existing occupancy, regardless of total floor area, is converted to a hazardous use. B. In all remodels/room additions where the total area exceeds 25% of the original square footage. (Allowance above 25% will require approval by the Fire Chief of the Vacaville Fire Protection District.) C. In all remodels/room additions with an existing sprinkler system, the system must be recalculated and designed to accommodate the additional flow demand. 2. An approved flashing light shall be installed on all new dwellings in such a position as to be plainly visible from the road fronting the property. The signal light shall be installed in such a manner that it will automatically activate in conjunction with the required sprinkler system. The light may also be installed in so that it may be manually activated to assist in locating buildings during other emergencies. The signal light shall be a flashing blue or white light capable of a minimum of 80 flashes per minute and a minimum of 25000-candle power. 3. Smoke Detectors Shall be provided and installed in accordance with section 1210 of the Building Code. 1001.5.1.3 UFC A. A smoke detector shall be installed in each sleeping room and at a point centrally located in the corridor or area giving access to each separate sleeping area. 1

4. Premises Identification A. To readily respond to emergencies, all homes, business and commercial properties must be easily identified with the address number. 901.4.4 CFC, 30-201 Solano County Ordinance. B. Upon receipt of the address number from the Director of Public Works, the occupant or owner of the property or building shall display the number upon the building or land in such a manner as to be visible from the road upon which the land or building fronts. C. Address numbers shall be conspicuous to ensure positive identification and placed on front doors, near garage doors, or at a single driveway entrance. D. Where residences and/or property are not clearly visible from the road, access identification other than mailboxes shall be on 4 X 4 wood posts, metal stakes, or equivalent markers elevated at least 3 feet for clear visibility and rapid directional identification. E. All numbers shall be a minimum height of 3 inches with a 3/8 inch stroke, reflective and/or color contrasting with the surface where placed. 5. Driveways - Roads Fire apparatus access shall be provided and maintained in accordance with the provisions of the Uniform Fire Code as adopted by the Vacaville Fire Protection District. To provide year-round, all-weather access for heavy fire engines and other emergency equipment to residential building sites that are not covered in the Solano County Road and Street Standards, these minimum access road specifications shall apply, 902.2.2.2 UFC: A. Plans for access shall be submitted to the District for review and approval prior to construction. B. Driveways shall extend from each building site to a public or private roadway and shall have an unobstructed width of not less than 20 feet (6096 mm) with suitable base material. Driveways may be a minimum 12 feet wide with authorization. 902.2.2.1 UFC C. The maximum grade allowed is 12 percent. Appendix III-D, Section 6.1 UFC D. Surface designed and maintained to support a 50,000 lb. load. 2

E. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where the driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. F. Turnout shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. G. Minimum centerline curve radius of 40 feet. H. Necessary drainage improvements. I. Turnaround facilities shall be provided at all building sites on driveways over 300 feet in length, and shall be within 50 feet of the building. The minimum turning radius for a turnaround shall be 40 feet from the centerline of the road. If a hammerhead/t is used, the top of the "T" shall be a minimum of 60 feet in length. J. Any required culverts or bridges shall be designed for a live load of 50 tons and be certified by a professional engineer. Vehicle load limits shall be posted at both entrances to bridges. K. Overhead clearance of limbs, trees, etc. shall be a minimum of 15 feet. 6. Hydrants A. All residences shall be no more than 1000 road feet from a fire hydrant. B. Hydrants shall be of approved type and contain a minimum of one 2½ and one 4½ NHS external thread outlets. (Equal to Model 614 Long Beach Iron Works) C. Hydrant fire flow shall conform to Fire District standards. D. Fire hydrants shall be clearly identified in an approved manner to prevent obstruction by parking and other obstructions. 901.4.3 CFC. E. Fire hydrants shall be identified by the installation of blue reflective markers located in the center of the roadway. 901.4.3 CFC F. Fire hydrants subject to possible vehicular damage shall be adequately protected with guard posts in accordance with Section 8001.11.3 CFC G. A 3-foot (914.4 mm) clear space shall be maintained around the circumference of fire hydrants. 1001.7.2 CFC H. The center of a hose outlet shall not be less than 18 inches (457 mm) to 36 inches above final grade. NFPA 24 3

7. Gates A. Gates shall be at least two feet wider that the width of the traffic lane serving that gate. B. All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that road. C. Where a one-way road with a single traffic lane provides access to a gated entrance, a 40-foot turning radius shall be used. (1) Electrically Operated Gates The design and installation of all electrically operated gates shall be in accordance with the following criteria: (a) (b) (c) (d) The gate control shall be operable by an approved emergency override Knox key switch that is an integral part of the mechanism. In the event of a power failure, the gate shall automatically be transferred to a fail-safe mode allowing the gate to be pushed open without the use of special knowledge or equipment. The key switch shall be labeled with a permanent red sign with not less than ½ contrasting letters reading FIRE DEPT or a Knox decal. A transmitter-operated gate shall have a Knox key switch on the right side of the gates opening approximately 48 above the roadway surface. It shall be visible and easily accessible with a label as specified above. Upon activation of the Knox key switch, the gate shall remain open until returned to normal operation by means of the key switch. (2) Manually Operated Gates and Barriers (a) A Knox padlock shall be used, in order for the Fire District to enter the property during an emergency in a timely manner without the destruction of private property. D. After investigation of the available products, it has been determined that only the product line offered by the Knox Company of Phoenix satisfies the security needs of the Fire District and the community. The Fire District will provide the only acceptable order form. 4

8. Roof Coverings All roof coverings shall be fire retardant as specified in the Uniform Building Code. Wood shakes or other wood materials applied as roof covering shall be fire rated as class B or better. 1504, Table 15-A UBC 9. Spark Arresters Chimneys used with fireplaces or heating appliance in which solid or liquid fuel is used shall be maintained with a spark arrester. 1109.7 UFC, 4291 (F) PRC 10. Development Impact Fees for New Construction On April 26, 2005, the Solano County Board of Supervisors passed and adopted Ordinance 1659 on behalf of the Vacaville Fire Protection District. The adopted fee became effective July 1, 2005. July 1, 2006 through June 30, 2007 a per square foot impact fee of $1.44 July 1, 2007 through June 30, 2008 a per square foot impact fee of $1.62 Vacaville Fire Protection District Disclaimer Statement This information is provided as a service to potential builders within the boundaries of the Vacaville Fire Protection District. These requirements represent merely an overview of preliminary building requirements and additional regulations shall apply. Revised: December 7, 2002 January 7, 2005 September 23, 2005 April 5, 2006 Forms/New Construction Requirements.doc 5