English. Series. Installation and Use Manual

Similar documents
SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

DUAL OPTIC. Installation manual

Installation And commissioning manual. Series S Double Beam 1/16

CONFIGURATION OF THE OPTICALS

BARRIERE & SENSORI BARRIERS & SENSORS

INDEX. Installation recommendation

BARRIERS & SENSORS Catalogue 2017

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

FSLIMPRO

INDICE. Installation recommendation

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED MODULATED BARRIERS

PARVIS Safe and tranquil thanks to Parvis

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

Description. Optex Incorporated

Long-Range Barrier Sensors

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

D-Tect 2 GJD300 Quad PIR Movement Detector

Movement Detector GJD 300

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

D-TECT Dual Tech. GJD360 Triple Technology External Detector

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

ACTIVE INFRARED BARRIER

Active Infrared Multi Beam Sensors. R Series

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Twin Photobeam Detectors Manual

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Active Infrared Multi Beam Sensors

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Perimeter protection

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Intrusion Outdoor Protection Perimeter

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

Table of Contents. 1. Mounting Tips... 2

PHOTOELECTRIC AMPLIFIER SERIES

WM3000 WIRELESS MODULES

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Laser Distance Sensor Type M Analog-Output

English. Italiano. Português. Françias. Español

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Intrusion. Outdoor protection perimeter

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Advanced DIGITAL Wired PIR Motion Detector

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

RS Pro Infrared Temperature Sensor

Quadruple-beam photoelectric detector

HX-80NRAM. High Mount Outdoor Detector

Safety Photo Beam UL MONITORED DEVICE

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

KwêBeams Effective wire free outdoor early warning system

"Pegaso" wireless alarm system

Photoelectric Beam Detector

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

2 General Application Photoelectric Sensors

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

2 General Application Photoelectric Sensors

1126 Series Ceiling Mount PIR Motion Detector

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

MWS3 Ceiling Mount Microwave Occupancy Detector

Optical Beam Smoke Detector RK90R - RK90RS

2 General Application Photoelectric Sensors

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

ECO N DATE DESCRIPTION OF CHANGE CHG

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Infrared Single Light Barrier. Mounting Instructions DO560

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

2 General Application Photoelectric Sensors

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

Laser Collimated Beam Sensor

Installation Manual Premier Elite Orbit QD/DT INS483-2

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

RLS-3060SH REDSCAN ULTIMATE

DI601AM Outdoor PIR/AM Detector Installation Sheet

FIRERAY 5000 range USER GUIDE

PHOTOELECTRIC DETECTOR

Transcription:

English Series FOSTER Installation and Use Manual FOSTER Rev.13 03/2015 MITECH srl reserves the right to change the information in this document without warning.

Index Anti-intrusion barrier 3 Main components 4 General installation instructions 5 Bracket mounting options 5 Mounting on pole with brackets - support FTN SUP 5 Wall Mounting - support FTN WL 5 Examples of installation 6 Example of how to protect an independent building 7 Cables and wiring on terminal board 8 Receivers board ( RX ) Fig. 1 8 Transmitters board ( TX ) Fig. 2 9 Power supply 10 Aligning the barriers 11 Initial manual alignment 11 Aligning the instrumentation 12-13 Settings and programming 14 Description of indicators (leds) 14 Description of characteristics and jumper settings 15 Technical specifications and consumption 16 Notes 17-18-19 FOSTER Installation and Use Manual Page 2 of 15

Foster anti-intrusion barrier WARNING - Observe the minimum distances between the Tx and Rx barriers (see table on page 15) - Power the device using the 13.8 Vdc stabilised voltage only - It is imperative you switch on the temperature control system for both internal and external installations (24Vac) VIEW OF THE TWO-LENS BARRIER WITHOUT PROTECTIVE COVER FOSTER Installation and Use Manual Page 3 of 20

Main components 2 3 1 8 Part No. Components Quantity Description 1 1 Aluminium bar 2 1 IR cover 3 2 + 2 4 From 2 to 5 Plugging caps + Rubber screw cap Optical assemblies receiver / transmitter 5 From 2 to 5 Flat cable 6 1 Motherboard with terminal board and cable/camper input 7 From 2 to 5 Expansion module 8 1 Tamper module 7 5 4 Part No. Quantity 1 FTN SUP 2 FTN WL 3 GAR POW Optional Description Pole-mounting bracket (1kit comprises two pieces A+B) E.g. 4 kits are required for a pair of barriers 1TX+1Rx Wall-mounting bracket E.g. 4 brackets are required for a pair of barriers 1TX+1Rx Dual power supply unit (cannot be incorporated into the barrier) 1 power supply unit supplies power to a pair of barriers 1 B 3 3 6 A 2 FOSTER Installation and Use Manual Page 4 of 20

General installation instructions 1. After installing the barrier, make sure that it is perfectly closed with the watertight covers supplied. 2. Use the cable clamps supplied to insert the cable in the lower section. 3. Make sure that the path between the sensors is free and that there are no obstacles that could affect the communication between the optical assemblies of the transmitters and receivers (i.e. branches, plants, leaves, etc. that could interfere with the beams). 4. Verify that the optical path of the transmitter used by the receiver barrier is not exposed to direct sunlight at dawn and sunset. 5. Do not stack several barriers, as this could cause the transmitters to interfere with several receivers. It is usually advisable to reverse the transmitters and receivers when installing the barriers (see page 6 in Figure 1-2). 6. Do not use switching power supplies that cause disturbance to power supplies when amplified by optically synchronized systems. Bracket mounting options Mounting on pole with brackets (ø pole 48 mm) support FTN SUP 2. Mounting on pole 1. Rear bracket insertion FTN SUP 2x FTN SUP 48mm Wall mounting support FTN WL FTN WL Rear bracket insertion FOSTER Installation and Use Manual Page 5 of 20

Examples of installation To be able to monitor the whole perimeter of an area, install the barriers as shown in the figure: Barriers can also be stacked: 1. One-lens barriers 2. Two-lens barriers FOSTER Installation and Use Manual Page 6 of 20

Example of how to protect an independent building The Foster barriers come with crossed beams for maximum protection. For visibility purposes, the beams in this drawing are linear. Barriers Tx - Tx Beam transmitted by barriers Rx - Rx Rx - Rx Tx - Tx Barriers WARNING - Always pole-mount two TX and/or RX columns of the same group, to avoid possible communication disturbances/interferences. - Ensure no interference is caused by the presence of photocells for automatic gates or microwave sensors, as these may blind the barriers. FOSTER Installation and Use Manual Page 7 of 20

Cables and wiring on terminal board Receivers board ( RX ) Fig. 1 RX AND (0 Volt) input FOSTER Installation and Use Manual Page 8 of 20

Transmitters board ( TX ) Fig. 2 TX FOSTER Installation and Use Manual Page 9 of 20

Power supply Example of supply barrier RX with unit GAR POW. Note: with a power supply can power a pair of barriers (RX-TX or RX or TX-RX-TX). GAR POW 220 Vac -12 Vdc +12 Vdc 24 Vda 24 Vda 6 5 4 3 2 1 RX CARD +12 Vdc -12 Vdc 24Vda 24Vda WARNING The barrier to work properly, it needs a voltage filtered and stabilized at 230 Vac. Then check the wiring before applying the power supply. FOSTER Installation and Use Manual Page 10 of 20

Aligning the barriers Initial manual alignment 1. Barrier supply (see page 10) 2. Turn the transmitters optical groups towards the receivers and viceversa, adjusting the lens holder horizontally and vertically with light manual movements (be careful to move only slightly). 3. Check the red leds on the electronics of the RX optics are all OFF Horizontal and vertical orientation FOSTER Installation and Use Manual Page 11 of 20

Aligning Aligning the instrumentation Note: Foster barriers are already pre-aligned by the manufacturer. In the event of problems arising during alignment, follow the procedure described below. Alignment procedure Reference value: approx 4V 1. Connect the tester to the RX expansion board situated most centrally on the column, on the contacts marked by the inscription T.P., using the specific cable supplied (redblack). T.P. 2. Move the test jumper on the TX base board to position ON 3. Move the jumper test on the first TX expansion board to position ON FOSTER Installation and Use Manual Page 12 of 20

4. Manually adjust the optics of the first lower TX expansion board, towards the centre of the RX receiving column (see image), in order to display the maximum voltage value of around 4 Volt on the tester (over 4 Volt the voltage values are to be considered optimal). It is important in this phase to ensure all the red leds on the RX optics electronics are switched off. In the event of some or all of the leds being on, if it is not sufficient to adjust the RX optics vertically and/or horizontally, redirect the TX optics until the leds switch off. Repeat the operation for all the other expansion boards. PROFILE TX TX PROFILE RX 4 Volt Multimeter RX 5. Set the Jumper Test to the OFF mode of the first TX expansion board at the bottom and repeat the alignment of all the remaining TX expansion boards. 6. Ensure all the jumper tests of the base board and of the TX expansion boards are set to OFF. Double lens version: verify that the barrier generates an alarm signal when each assembly with two lenses is covered (OR setting). Single lens version: verify that the barrier generates an alarm signal when each lens is covered (OR setting). NOTES: a) Some multimeters might display a voltage that is up to 50% lower than the real value, therefore check the equipment is working correctly. b) The use of some transceivers to communicate during installation could affect the multimeter readings. FINAL WARNINGS: During the alignment procedure, verify the following on the base board of the receiver (RX): o the blinding led must be switched off o the AND and automatic mist disabling functions (signal low) must be set to OFF. The settings of the trigger blinding sensitivity trimmer must remain in the default position (the lever must be adjusted vertically, see image). FOSTER Installation and Use Manual Page 13 of 20

Settings and programming Description of indicators (leds) FOSTER RX boards have 6 indicators (leds) used for control purposes, which can be enabled by moving the jumper on the two-pin connector marked as leds to position ON. It is generally advisable to move the jumper back to position OFF at the end of the testing phase. Led S.LOW: low signal (DISQUALIFICATION) Led S.LOW switches on to indicate the presence of intense mist. If intense mist is detected, the barrier does not initially generate an alarm message signalling a missing signal, but switches the S.LOW led on, issuing the signal DISQUALIFICATION on the terminal board (open collector). Led MASK: Blinding signal Led MASK switches on and blinks to signal that the infrared signal detected has a modulated intensity above the one of the signal used. Note: this led is generally OFF in ordinary operating conditions. If the led continues to be lighted or blink, increase the blinding immunity by adjusting trimmer MASK (turn it clockwise to increase sensitivity). Led DETECT: Beam interruption detection Regardless of the alarm output resulting from the tripping delay, which can be adjusted with trimmer SPEED, led DETECT always switches on when the beams of the barriers are obstructed for a long or short period of time. Note: this led is generally OFF in ordinary operating conditions. The led blinks if one or more transmitter signals are not detected. The led lights permanently if no signals are detected from all the transmitters or if one or more receivers are blinded or incorrectly aligned. Led ALM: Alarm acknowledgement This led is normally OFF and switches on to signal the presence of an alarm. The alarms of FOSTER barriers depend on the tripping delay set on trimmer SPEED, which can range from a minimum of 50 msec to 500 msec (turn the trimmer clockwise to increase the delay). Led HTR: Heating system enabling acknowledgement FOSTER barriers have an automatic heating system with electronic control that guarantees a minimum internal temperature of 17 C in all environmental conditions. If the led is on, the heating system is working correctly. POWER: power supply Led POWER is the only one that is permanently on in ordinary operating conditions. It is used to indicate that the board is correctly powered. FOSTER Installation and Use Manual Page 14 of 20

Description of characteristics and jumper settings FOSTER RX boards can be programmed in different configurations by means of the jumpers. RX BOARD BEAM (preset by manufacturer) Use all the jumpers that correspond to the number of receivers fitted on the barrier (if the barrier has 4 double or single lenses, move jumpers to positions 3 and 4). TX BOARD BEAM (preset by manufacturer) Enable only the jumper that refers to the TX optics fitted on the barrier (for example if the barrier has 4 beams, move the jumper to position 4). AND The selection of the ON mode enables to attain the random AND of two beams, which means that an alarm is generated only if at least two beams generate an alarm. This applies to all the beams used both on transmitters and receivers. This function can also be programmed remotely through the 0 Volt command on the terminal board. SPEED TRIMMER Trimmer for the adjustment of the tripping time (50 msec - 500 msec). MASK TRIMMER Trimmer to adjust the sensitivity of the anti-blinding device (generally preset by manufacturer). LEDS If moved to position ON, this jumper enables the leds. NOISE (RX) This jumper has to be programmed if interference from transformers, inverters, etc. is detected. S. LOW: low signal (DISQUALIFICATION) This jumper has to be programmed if intense mist is detected. Note: The S. LOW and MASK outputs provide a transistor NPN that is normally open and closes towards 0V when the output is active. FOSTER Installation and Use Manual Page 15 of 20

Technical specifications and consumption Technical specifications Maximum operating range outdoors (two lens model) Maximum operating range outdoors (one lens model) 100 meters 70 meters Minimum distance 4 m (height 1 m) - 15 m (height 1.5-2.0-2.5 3.0 m) Barrier height Synchronization Total number of beams Power supply Disqualification Max. absorption of columns (version 5 lenses) Maximum absorption of column heaters Operating temperature 1.0 m - 1.5 m - 2.0 m - 2.5 m 3,0 metres Optical 50 crossed 12Vdc Automatic with external signals Tx 120 ma + Rx 270 ma 30W +30W 24Vac with heat regulator 25 C +70 C Vertical alignment angle 30 Horizontal alignment angle 180 Detection system Anti-blinding system Tripping time Alarm output Tamper output Led indicators IR signal AND / OR on Tx and Rx remote AND Automatic, can be disabled Adjustable, 50 / 500 ms Contact of exchange relay NC/NA NC contact Power supply, blinding, heating, low signal, alarm, detection Pulsed, coded Class of protection IP 65 Full warranty 2 years Consumption BARRIER TX RX TOTAL DESCRIZIONE FTN 102M 120mA 110mA 230mA Barriers with 2 single lenses 2TX+2RX (4 cross beams) FTN 102D 120mA 110mA 230mA Barriers with 2 double lenses 2TX+2RX (8 cross beams) FTN 152D 120mA 110mA 230mA Barriers with 2 double lenses 2TX+2RX (8 cross beams) FTN 153D 120mA 150mA 270mA Barriers with 3 double lenses 3TX+3RX (18 cross beams) FTN 154M 120mA 230mA 350mA Barriers with 4 single lenses 4TX+4RX (16 cross beams) FTN 154D 120mA 230mA 350mA Barriers with 4 double lenses 4TX+4RX (32 cross beams) FTN 204M 120mA 230mA 350mA Barriers with 4 single lenses 4TX+4RX (16 cross beams) FTN 204D 120mA 230mA 350mA Barriers with 4 double lenses 4TX+4RX (32 cross beams) FTN 205D 120mA 270mA 390mA Barriers with 5 double lenses 5TX+5RX (50 cross beams) FTN 206M 120mA 270mA 390mA Barriers with 6 single lenses 6TX+6RX (36 cross beams) FTN 254D 120mA 230mA 350mA Barriers with 4 double lenses 4TX+4RX (32 cross beams) FTN 255D 120mA 270mA 390mA Barriers with 5 double lenses 5TX+5RX (50 cross beams) FTN 304D 120mA 230mA 350mA Barriers with 4 double lenses 4TX+4RX (32 cross beams) FTN 305D 120mA 270mA 390mA Barriers with 5 double lenses 5TX+5RX (50 cross beams) FTN 355D 120mA 270mA 390mA Barriers with 5 double lenses 5TX+5RX (50 cross beams) FOSTER Installation and Use Manual Page 16 of 20

NOTES : FOSTER Installation and Use Manual Page 17 of 20

FOSTER Installation and Use Manual Page 18 of 20

FOSTER Installation and Use Manual Page 19 of 20

MITECH S.r.l. Offices: Via Roncaglia, 14-20146 Milano - Italy Tel. +39 02.48006383 Fax+39 02.48025620 Production: Via Ramazzone, 23 43010 Fontevivo (Parma) - Italy Email: tech@mitech-security.com www.mitech-security.com FOSTER Installation and Use Manual Page 20 of 20