System Overview. PC4020 v3.3

Similar documents
WIRELESS CONTROLS & DETECTORS

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

P Zone Expandable Hybrid Security System

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1

PC4020 v3.2 Installation Manual DLS-3 v1.3

DS7400Xi Addressable Control/ Communicator

PC4020 v3.2 Installation Manual DLS-3 v1.3

System Manual W A R N I N G. PC6O1O Software Version 2.1

System Introduction. 1.1 Specifications

CATALOG 2008 EMEA EDITION

EVO192 v3.0 Fire and Burglary What s New

TECHNOLOGY PACIFIC SECURITY. Wireless Internal Siren. 2-Way Wireless Outdoor Siren. Alexor 2-Way Wireless Panel

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

PC4020 v3.3 (US, UL) Installation Manual DLS-3 v1.3

PC4020 v3.3 (US, UL) Installation Manual DLS-3 v1.3

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

security timeless design innovative products inspired technology

Installation Guide. NT9010 v 1.0. DLS-3 v1.3 and higher

Programming Worksheets

Installation Manual. This panel will not operate if installed outside of North America. See section 1.1 for details.

The complete wirefree security alarm solution

Integrated Security Solutions

KT-100 Door Controller

From Tyco Security Products PRODUCT CATALOG

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

PC4020 v3.5 (International) Installation Manual DLS2002 or higher

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

NORTH AMERICA CATALOG 2011/2012. proceed to contents

Integrated Security Solutions

Installation Manual RF55O1-433

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Table of Contents. Appendix A Special Characters 31

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

OJD ITB No Attachment E Duress Alarm Equipment Specifications

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

MKTCTBLEFURTINC R001. Catalogue nd Edition

Works when it matters most.

Security Alarm Systems

All-In-One Wireless Security System V1.0. Model #: MG-6060

Addressable Fire Alarm Control Panel

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

INSTALLATION GUIDE XTLN-WIFI PANEL

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Intelligent technology made simple

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Works when it matters most.

Intrusion. Control Panels

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Powerwave Series. Technical Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Installation Instructions

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

UltraSync Modular Hub

TABLE OF CONTENTS TABLE OF CONTENTS 1

Easy Series Intrusion Control Panel. Selection Guide

Contents. Glossary

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

CC408. Quick Reference Guide Solution 880

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

UNC100 Integra Manual

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

>WIRELESS> ALARM SYSTEM CR200

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

F1 Smart Home Security Sensors. Unlocking the Potential of Your Wireless World

U ser's Guide PC6010

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ACP10 & ACP50 Security Systems

proceed to next page From Tyco Security Products North America

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

D2412 Control / Communicator Installation Manual

4-PGM Expansion Module

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

WARNING Software Version 2.3 / DLS-1 v6.7 and up See Back Cover for New Features in Version 2.3

Power864. Installation Manual IMPORTANT. PC5O2O Version 3.1 DLS-3 v1.3 and higher

HARDWIRED CONTROL PANELS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

High-End Wireless Security

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Transcription:

System Overview PC4020 v3.3 The MAXSYS system meets today s challenges with the seamless integration of security, access control, fire alarm, automation, and intercom features that single function systems cannot match. Hardwired input/output expansion over a 4-wire Combus, wireless input expansion, 2-way voice intercom, TCP/IP communication support, and 2- wire addressable input expansion all combine for installation simplicity, flexibility, and economy. Tomorrow s challenges are solved today because access control, fire alarm, Escort audio-assist and automation features are designed into the MAXSYS security panel, ready to be implemented when you need them. Up to 16 Keypads - LCD4500 & LCD4501 series plain language keypads - LCD4520 & LCD4521 series plain language keypads with red bezels Expand Up to 128 Zones Hardwired Expansion Up to 128 zones using - PC4108A 8-zone expansion modules - PC4116 16-zone expansion modules Addressable Expansion Up to 128 addressable zones using DSC addressable devices on 2 addressable loops Wireless Expansion Up to 64 wireless zones using up to 8 PC4164 wireless receivers and DSC wireless detectors 8 Partitions 1,500 User Codes 3,000-Event Buffer Local & Remote Upload/Download Advanced Communications Supports SIA, Contact ID, 10bps and 20bps formats SKYROUTE MAX Cellemetry communication SURE SIGNAL packet data radio communication DVACS communication using PC4401 module T-Link TCP/IP communications Central station talk/listen-in Event-initiated personal paging Cellemetry is a registered trademark of Numerex Corp. DVACS is a trademark of Electro Arts Limited CE Bus is a trademark of CEBus Industry Council Inc. (CIC) Ease of Installation Addressable loop expansion - integral 2-wire addressable loops expand the system to full zone capacity without the added cost of system expansion modules - addressable devices use less current thereby reducing standby power requirements Combus hardwired expansion - simple hardwired system expansion using standard, non-shielded, 4-conductor station wire to connect hardwired keypads and modules up to 1,000ft (305m) from the main control panel - Combus regenerator using PC4204CX extends wire runs Output Expansion Maximum of 144 low current outputs using up to 9 PC4216 16-output modules Maximum of 64 relay outputs using up to 16 PC4204, PC4204CF, or PC4204CX power supply/ 4-relay output modules Annunciation Point/ graphic annunciation using - PC4632 32-zone annunciator - PC4664 64-zone annunciator Fire zone annunciation using PC4612 and PC4612A 12-zone fire annunciators System printer using PC4401 serial output module Integrated Access Control 32 doors using 16 PC4820 2-reader access control modules 1,500 access cards Multiple reader technologies IoProx proximity, 26 bit standard Wiegand, Kantech XSF, Polaris, mag. stripe Integrated Voice-Assisted Security & Building Automation Escort4580 operates in conjunction with any DTMF (tone) telephone to provide voice-assisted security and automation control for up to 32 CEBus or X-10 devices UL/ULC Central Station Fire Alarm All the features of the standard security versions plus special fire system modules - PC4701 fire module with supervised smoke zone, waterflow zone, and dual supervised communicator outputs - PC4612 and PC4612A 12-zone fire annunciators - PS4350R fire system external battery charger - PC4204CF power supply/ 4-relay output panel - LCD4520 & LCD4521 series plain language keypads with red bezels

ADDRESSABLE EXPANSION Benefits: Use 2-wire addressable loops to easily expand to full system capacity without the added cost of system expansion modules. Reduces standby battery requirement due to lower current draw of AML devices Installer-selectable device lockout Simple device test of glassbreak and smoke detectors Each device is fully supervised AMA-100 Acuity Glassbreak Detector Exceptional microphone frequency range provides excellent sound capture at low sound levels and distances up to 25ft (7.6m) Detects breakage of all common types of glass, including plate, float, wired, tempered, and laminated Built-in tamper switch AFT-100 glassbreak tester available AMS-220 Series Photoelectric Smoke Detectors AMS-220 2-wire smoke detector AMS-220T includes 135 F (57 C) fixed temperature heat sensor Red solid-state LED indicator light Continuous self-test for low sensitivity Manual and programmable scheduled tests for low sensitivity and alarm operation Locking/non-locking mounting plate AMB-300 Passive Infrared Motion Detector Multi-level signal processing (MLSP) Dual-element low noise sensor High level static and transient protection High white light and RF immunity Tamper switch Up to 50'L x 60'W (15.2 x 18.3m) coverage 4 lenses available AMX-400 Addressable Loop Regenerator Module extends the allowable wiring distance on the addressable loop Isolates addressable devices which limits the effect of short circuiting Can be powered from the auxiliary power of the control panel or an independent power supply AMB-500 Ceiling-Mount 360 PIR AMP-700 Series Contact Modules Ceiling-mount Quad-element low noise PIR High white light & RF immunity Multi-level signal processing (MLSP) Up to 40' diameter (12.2m) coverage AMB-600 Dual Element Pet-Immune PIR AML-770 Loop Isolator AMP-700 magnetic door / window contact with built-in tamper switch AMP-701 3 inputs to monitor external NC alarm, tamper, and trouble contacts AMP-702 fire point module with 5600Ω EOL supervised loop that monitors N/O contacts Multi-level signal processing (MLSP) Two dual-element low noise sensors High static and transient protection High white light and RF immunity Tamper switch 40'L x 50'W (12.2 x 15.2m) coverage For a single pet weighing up to 85 lbs (38 kg) Provides short circuit isolation for devices connected on the addressable loop Self resets upon removal of short circuit condition Local LED indication of normal and isolation operating status

FIRE ALARM PC4020CF Fire Alarm Control Panels LCD4520/4521 Plain Language Keypads LCD4520 LCD4521 Identical to the standard security keypads but with red bezels. All the security features of the PC4020 plus added fire features Red cabinet PC4701 fire module includes - built-in transformer - one 2-wire ClassB/StyleB supervised smoke zone - one ClassB/ StyleB waterflow zone - dual supervised digital alarm communicator outputs - common fire alarm & fire trouble relays, form 'C', 2A, 30VDC contacts All panel and expansion zones are configurable for waterflow or fire supervisory UL/ ULC Listed for Central Station Fire Alarm AUTOMATION Escort4580 Voice-Assisted Security & Building Automation Module PS4350R Fire System External Battery Charger INTERCOM PC4936 Audio Interface Module PC4937 Expansion Audio Module PC5921 Intercom Stations PC5904 2-Way Listen-In Station External battery charger c/ w PC4055CR cabinet, red PS4085 multi-rate charger module PT1012 transformer 12VAC Space for 65Ah lead-acid battery The Escort4580 * module allows the telephone to be used as a keypad while providing the user with plain language operational and programming voice prompts, and system status reports. In addition, the Escort module acts as an interface to CEBus or X-10 automation control devices and provides voice-assisted operation and programming of these devices. System Status & Control - Voice Prompt-Assisted Control system or check the system status from any local or remote DTMF (tone) telephone Global or partition access 180 word standard library and 241 word user-programmable library Up to 6 words per voice prompt Automation Control Built-in power line interface for up to 32 CEBus or X-10 control devices Programmable event activation using 16 event timers and 8 schedules Control outputs via local or remote DTMF (tone) telephone keypad * The Communiqué VPM4580 can be used in place of the Escort4580 when a Communiqué telephone system is used in conjunction with the MAXSYS system PC4936 audio interface module (7 ports) with PC4937 expansion module (8 ports) provides 15 output ports for connection of up to 15 PC5921 series intercom stations Local intercom functions - page/answer - do not disturb - doorbell function - door strike release Listen-in broadcast allows any station to be programmed as a broadcast station to which all other internal stations in the system can listen in Answer telephone calls received on a regular voice line - ringing programmable by station - supports call waiting - allows call transfer to in-house phones Use as sounder for fire/ burglar alarms Audio user help plus verbal alarms & verbal door chime - provides plain language system status reports including verbal alarms and door chime annunciation, as well as voice prompts for system operation when installed with Escort4580 Voice Prompt Module and keypads mounted with PC5921 intercom stations PC5904 central station 2-way listen-in station - control tones programmable from central station - select zone, listen/talk, extend on-line time, hang up

SECURITY PC4020 Security Control Panel LCD4500/4501 Plain Language Keypads LCD4500 16-zone main panel Expandable to 128 zones 2 addressable loops for up to 128 addressable devices up to 16 LCD keypads per system 8 partitions 1,500 user codes (4 or 6 digit) 3,000-event buffer 9 account and 3 phone numbers 1 supervised bell zone PC-Link for local upload/ download Remote upload/download with DLS-3 software Supervised digital alarm communicator Optional attack-resistant cabinet Space for two 7Ah rechargeable batteries Fully networkable using the T-Link module LCD4501 2-line, 32-character display Adjustable display brightness and contrast LCD and keys backlit for low light viewing 'Backlighting Boost' on LCD4501 for low light conditions Display zone and system status, trouble conditions, event buffer, and system instructions Piezo buzzer provides audible feedback for correct/ incorrect key entries, entry/ exit alert, and system trouble conditions Global or partition operation 4 keypad-activated alarms panic, auxiliary, fire, and duress 5 programmable keypad functions Separate function keys on LCD4501 Trouble and Armed LEDs on LCD4500 Trouble, Armed, and Ready LEDs on LCD4501 Trouble buzzer Tamper versions available ACCESS CONTROL PC4820 Two Reader Access Control Module Multiple Reader Technologies 16 modules per system 32 readers total 1,500 access cards Polaris Mag-Stripe Readers/ Cards, 26-bit standard Wiegand Distributed processing, for full off-line operation Arm/ disarm partitions and postpone auto-arm by access card or access card and code from outside the protected space 2 low current outputs per door 4 inputs per door door contact, request-to-exit input, arm, and postpone auto-arm 64 access levels 99 seven-day schedules 4 holiday groups, 730 holidays Individual door unlock schedules Fully supervised Program from keypad, or from computer with DLS-3 downloading software 1.5A regulated power supply Multiple reader types supported Power available per door reader 125mA max. @ 5VDC or 250mA max. @ 12VDC lock 250mA max. @ 12VDC Auxiliary power 125mA @ 12VDC Battery req d 12VDC, 7.0Ah Transformer req d 16.5VAC, 40VA PC4850 Telephone Entry Module - integrates access control with building telephone entry - up to 16 PC4850s to control up to 32 doors - 1,500-name, fast scrolling, electronic directory - 12-digit phone numbers - PC4851 no telephone bill option IoProx Proximity Readers/ Cards and Kantech XSF Reader IoProx Proximity Reader with keypad and Kantech XSF version

WIRELESS DEVICES & DETECTORS Wireless Pet-Immune PIRs WLS914-433... DUAL ELEMENT PET-IMMUNE PIR PIR with Multi-Level Signal Processing (MLSP) Coverage up to: 40'L x 50'W (12.2 x 15.2m) Two dual-element low noise sensors For one pet weighing up to 85 lbs (38kg) Excellent false alarm immunity and catch performance 4 AA batteries (supplied) WLS904PL-433 PIR WITH PET IMMUNITY Vertical beam shaping lens* Coverage up to 40 L x 40 W (12.2 x 12.2m) Immunity for multiple pets - 60lbs (27.3kg) total Good false alarm immunity and catch performance High traffic shutdown to preserve battery life 2 lithium batteries (supplied) WLS906 Photoelectric Smoke Detector WLS906-433** PHOTOELECTRIC SMOKE DETECTOR UL/ULC Listed/ CE0560! Exclusive (patented) smoke chamber design provides: - maximum smoke detection - exceptional resistance to dust, insects and air turbulence, thereby reducing false alarms 90 smoke detection pattern Red solid-state LED indicator Loud 85dB alarm horn Automatic self-test once every 40 seconds with visible and audible trouble indication for low smoke sensitivity and low battery Manual user sensitivity test button with local indication of test result Installer test mode allows test locally or by transmission to central station 6 AA batteries (supplied) WLS912 Glassbreak Detector Wireless Transmitters & Contacts WLS907T-433 LOW TEMPERATURE SENSOR*** Sends an alarm when a pre-defined low temperature is reached The pre-defined temperature points at which an alarm and restoral condition are sent are: - Alarm: 43 F ± 3 F (6 C ± 2 C) - Restoral: 48 F ± 3 F (9 C ± 2 C) Fully supervised 3 AAA batteries (supplied) WLS925L-433 MINI DOOR/WINDOW CONTACT*** A magnetic door or window contact Complete with surface-mount magnet Terminal connection for an external contact 1 lithium battery (supplied) Available with a wall tamper switch (WLS935L-433) WLS919 Wireless Key North American # 29003516 R002 WLS912L-433 GLASSBREAK DETECTOR Exceptional microphone frequency range provides excellent sound capture at low sound levels and distances up to 25ft (7.6m) Detects breakage of all common types of framed glass including plate, float, wired, tempered, and laminated 2 lithium batteries (supplied) PC4164 Wireless Receiver Distributed wireless reception - install up to 8 wireless receivers to allow wide area roaming with wireless keys Capacity... 64 wireless zones (PC4020)... 16 wireless keys WLS919 WLS909 WLS909-433 & 919-433 WIRELESS KEYS WLS919-433 features a slide cover, preventing accidental activation 4 programmable function buttons... - Preprogrammed for STAY' arm, 'AWAY' arm, Disarm, and Panic Supervised for low battery Water-resistant (WLS919 only) 2 long-life lithium batteries (supplied with WLS919) 3 x A76 batteries (supplied with WLS909) * Patent Pending ** For residential applications only *** Supervised for tamper, device fault, low battery Printed in Canada 09/01

HARDWIRED EXPANSION INPUT PC4108A/4116 8/16-Zone Expansion Modules ANNUNCIATORS PC4632/4664 Point/Graphic Annunciators PC4612 PC4108A 8-zone input module PC4116 16-zone input module 30 programmable zone types - all zones programmable as NC, EOL, and DEOL 250mA, 12VDC auxiliary power for local devices Add up to 112 zones on PC4020/4020CF OUTPUT PC4216 16-Zone Low Current Output Module PC4216 PC4204 PC4204CF 16 programmable outputs Outputs rated for 50mA @ 12VDC 59 programmable output options Up to 9 modules/system for 144 total outputs on all systems PC4204 Power Supply/4-Relay Output Module/ Combus Regenerator Up to 2.2A @ 12VDC power for - Combus power - local input devices - local output signals PC4204CX Combus Regenerator extends wiring distance up to 4000 (1220m) 4 form 'C' programmable relays - contacts rated for 2A @ 30VDC 59 programmable output options Supervised for - AC power fail - aux. supply fault - low/disconnected battery PC4020 up to 16 modules per system for 64 relays total PC4204CF Power Supply/4-Relay Output Module Packaged version of PC4204 for UL Listed commercial fire systems Up to 550mA @ 12VDC power for - Combus power - local input devices - local output signals PT1016 transformer 16VAC, 40VA (supplied) PC4052CR cabinet, red Space for one additional PC4108A module Space for two 7Ah rechargeable lead acid batteries all other specs the same as the PC4204 PC4612A Remote system annunciators for point or graphic display of zone, partition, and system status information Display up to 144 points per system with multiple annunciators Connect anywhere on the Combus Egg-crate backplane for flexible indicator location Red, yellow, and green LED assemblies Clear transparencies (2) for custom graphics - PC4632... 32 point - 8.5" x 11" (21.6 x 27.9cm) display area - PC4664... 64 point - 11" x 17" (27.9 x 43.2cm) display area PC4612 & PC4612A point annunciation of up to 10 fire zones and 2 supervisory zones - PC4612... matches LCD4500 style keypads - PC4612A... matches LCD4501 style keypads Alternate Alarm Communications... T-Link... TCP/IP Communications Module PC4632 COMMUNICATIONS - uses the TCP/IP protocol to transmit alarm signals - compatible with 10BaseT networks - allows control panel to maintain telephone backup connection - DLS communication over LAN/WAN PC4401 Serial Interface Module DLS-3 SA System Administrator Software - User-friendly Windows - based software - Program user cards, codes and schedules - Sort and print system event buffer - View system status - Remote keypad commands available PC4664 SKYROUTE MAX - Cellemetry receiver snaps into MAXSYS enclosure and connects to the Combus - no additional power supply or cellular account required SURE SIGNAL - Packet radio supervised wireless communication DVACS high security communications interface DataLink data port - RS-232 serial interface - allows integrators real-time access to system events and the ability to send control commands to MAXSYS Printer interface - print time and date - stamped reports of system events - supports 300, 1200, 2400, and 4800bps serial printers Represented by : DSC is a registered trademark of Digital Security Controls Ltd. and may not be reproduced without permission Windows is a registered trademark of Microsoft Corp. 2001 Digital Security Controls Ltd. Toronto, Canada www.dsc.com An ISO9001 registered company