Hot Water Circulator Pump LRP

Similar documents
SELF-PRIMING JET PUMPS

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

Elite Primer Baldor Series External Pond Pump

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

V80-H Multistage Pump Instruction Manual

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Flow Factor ~

OPERATION & MAINTENANCE INSTRUCTIONS

WET ALARM VALVE CPF FIRE V.A.U. 3 V.A.U. 4

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

SUBMERSIBLE DIRTY WATER PUMP

CHAMPION PUMP OWNER S MANUAL

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

USER S INFORMATION MANUAL

VADA - Rain2Main Automatic Rainwater Controller

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

APW PSI PRESSURE WASHER

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Antari Low Fog Machine

Refrigerated Compressed Air Dryer

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

MD SERIES Instruction Manual

30 Misting/Oscillating Fan Model Number 01030

Hand Dryer Installation & User Manual

OWNERS GUIDE TO INSTALLATION AND OPERATION

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL

Models: RP-10, RP-15, RP-20. User Manual

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Bar Fridge USER MANUAL MB46W

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

CRU-S Series Stainless Steel Condensate Recovery Unit

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Please Read and Save These Instructions.

Inverted Bucket Steam Traps

Instruction Manual for Dust Collector

2 INSTALLATION OPERATION TECHNICAL SPECIFICATIONS COMPONENTS FUNCTIONS REPAIR Series TS14/TDS14/PL138

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Service Manual Washing Machine

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

16 OUTDOOR MISTING FAN

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

DIRTY WATER SUBMERSIBLE PUMP

OPERATING AND INSTALLATION MANUAL

DIRTY WATER SUBMERSIBLE PUMP KIT

SAFETY AND OPERATING MANUAL

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

ECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING AND INSTALLATION MANUAL

CHILLER. Operator s & Installation Manual

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Food Waste Disposer Instruction Manual

Astro 2 circulator models. Installation and operating instructions

INSTRUCTION MANUAL Water Dispenser

User s Information Manual

30-pint Dehumidifier User Guide

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

USER MANUAL WATER DISPENSER WITH ICE MAKER

Operation and Maintenance Manual 120V/60HZ

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities

Decentralised ventilation units

Pump WaterVISE, FloVISE

User s Information Manual

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Installation and operating instructions. DK energy storage and DK energy buffer

Single Handle Lavatory Faucet

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

O P E R A T I N G M A N U A L

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

6000, 8000, & 15000

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Snifter ATEX22 VERSION. User Manual. Distributor

ULTRASONIC HUMIDIFIER

ULTRASONIC HUMIDIFIER

CHEST FREEZER Model Number: EWCF5W

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Register your product within 30 days of purchase to activate its one-year

Transcription:

Hot Water Circulator Pump LRP

Contents. Introduction.... Safety Instruction... 3.Product Structure... 4 4. Technical Parameters... 7 5. Precautions... 8 9. Troubleshooting Disconnect power supply before service. Problem Possible cause Remedy The motor does not run No power at outlet Motor clogged Impeller plugged Check the fuse and electrical connection Remove the vent hole. Turn the rotor with screwdriver Remove the sundries 6. Installation... 9 Low voltage Adjust the voltage 7. Electrical Connection... 9 8. Cleaning & Maintenance... 9 9. Common Failures & Troubleshooting... 0 The pump does not supply water but the motor is running Capacitor broken Air in the hose Sundries at the impeller entrance Replace the capacitor Check the hose to prevent air from entering into the hose Have the impeller cleaned by the professional Noise from the pipeline The flow rate has been set too high Air in the pipeline Switch to low speed operation Discharge the air in the pipeline Noise from the pump during operation Air in the pump or hose Exhaust pipe broken Turn on the tap. Run the pump for minutes to discharge the air in the pump Increase the system pressure within the permitted range If you fail to solve a problem after following the tips in the above table, please call local distributor or call the customer service of our company: 0-7-39. 0

6. Installation ). ). maintenance. 3). 4). All welding has been finished in the pipe system before installation. Make sure there are no foreign material and sundries in the pipe system, thus it can ensure the pump from damage. The pump shall be installed in a place where it is easy to access. It is advisable to install a valve beside the inlet, to make it easy for In order to prevent water from splashing onto the motor and casing, when replacing pump, priming or reinstall the entire pipe system, it is advisable to install a separating valve at pump inlet and outlet. The flow direction must in accordance with the arrows indicated on the pump. 7. Electrical Connection WARNING Unless the power is off, do not wiring the junction box. The electric pump should have reliable grounding to prevent current leakage with leakage protection switch being equipped. Electrical connection and protection should be conducted according to stipulations. Specification of working voltage is marked on the nameplate; please ensure the motor is in accordance with power supply. In case the working area of the electric pump is too far from the power supply, power transmission lines should be of a heavier gauge, otherwise the electric pump cannot work normally because the voltage drop is too dramatic. In case the electric pump is used outdoor, extended lines should apply rubber cables for outdoor use. 8. Cleaning & Maintenance ). ). 3). The pump is free-of-maintenance under normal conditions. It is advisable to keep water clean. In case of any frost and ice damages, please open the drain plug to empty water in the pump chamber. When start up the pump again, open the drain plug, fill water and tighten it and then the pump is usable. Turn off the bleed valve and open the inlet valve. Make sure there is water inside the pipe before starting the pump. In summer or when the ambient temperature is high, pay attention to ventilation, avoid dew on electrical parts which will result in electrical faults. Before installation, you should carefully read this manual..introduction LRP series is a hot water-circulation pump, which features adjustable speed. Three speed levels are available. It is suitable for circulation systems with pressurized liquids, hot-and-cold water circulation system, water booster for family use, closed industrial circulation systems, air-conditioning systems, heaters, even for circulation of fish-pond and fish-tanks, and as a pressurized supplier for watertowers, etc. Operating conditions: Non-inflammable, non-adhesive and non-explosive liquids not containing solid particles, fibers and mineral oil O Liquids temperature: +~+0 C O Ambient temperature: +~+ C Max. Operation pressure: 0bar Protection grade: IP44 Insulation grade: Class H.Safety Instructions Manual 0N OFF 0 0 ). To ensure normal and safety operation of the electric pump, read the manual carefully before use. ). The electric pump should have reliable grounding to prevent short circuit; for safety, leakage protection switch should be equipped and be careful not to wet the power plug; socket should be connected in damp-proof area. 3). Do not touch the electric pump while working. 9

CHEMCALS C 4). Avoid splashing pressured water to the electric pump as well as prevent the pump immersed by water. 5). Keep the pump in ventilation. 6). In case ambient temperature is lower than, take anti-freezing measures to avoid ice cracking of the pump chamber. 7). Do not transfer any inflammable, explosive or gasified liquids that beyond the stipulation. 8).Ensure the pump will not be accidently turned on while installing and maintaining. The maintenance shall be done by the professional. 9).Power supply should be in accordance with the voltage stated in the nameplate. 5. Installation & Precautions ). ). 3). The pump must be firmly grounded. A 30mA leakage protection switch must be installed. Never run the pump dry. Prevent water from entering into the motor or splashing onto the pump, so as to avoid the risk of electric shock. 4). The pump must never be exposed, including being used outdoors; otherwise its service life will be greatly reduced, along with an increase of chance of electric shock. 5). Never cover the pump surface. The pump must always have ventilation, to reduce the risk of fire. 6). With the exception of the speed switch, never touch the pump while it is running. 7). A drainage facility should be implemented in the vicinity of the installation site. Make repairs to the pump immediately upon leaks being noticed during operation, to avoid risk of electric shock, damage of surrounding equipment, and damage to its exterior. 8). The motor shaft shall be installed horizontally. 9). Place the pump at the boiler outlet. An automatic air release valve needs to be installed at the pump inlet. 0). Add non-softened water to the heating pipelines as infrequently as possible, to avoid calcium deposits accumulating in the pipeline, which will block the impeller. ). In the winter when the ambient temperature drops below 0 or when the pump has not been used for extended period. Drain the pipe system completely, to prevent cracking of the pump body. ). The liquids transferred may be hot and is under high pressure. First empty the liquids in the system or close the cutoff valve before moving and disassembling the pump, to avoid scalding. 3). The hot liquids under high pressure flow out once the discharge plug is removed. Make sure the hot liquids will not result in personal injury or cause damage to other components. 4). Make sure the pump is disconnected from the socket when adjusting the speed. 5). When the pump has not been used for extended period, shut off the valve at the pump inlet and power source is disconnected. 6). Keep out of reach of children after installation of the pump. 7). The pump shall be placed in a dry, ventilated and cool place at normal temperature. 3 8

4. Technical Parameters Model LRP5-50/ LRP5-50B/ LRP0-50/ LRP-50F/0 LRP5-50/ LRP5-50/ LRP3-50/ LRP5-/ LRP5-B/ LRP0-/ LRP-F/0 LRP5-/ LRP5-/ LRP3-/ LRP5-K/ LRP5-K/ LRP5-/ LRP5-B/ LRP0-/ LRP-F/0 LRP5-/ LRP5-/ LRP3-/ LRP-70F/0 LRP5-70/ LRP5-70/ LRP3-70/ LRP5-/ LRP3-/ LRP3-F/0 LRP36-F/00 LRP-F/50 LRP5-0/ Voltage/ Frequency ~0V/Hz ~0V/Hz Input Power(W) 3 9 9 46 46 46 46 00 6 6 3 3 3 3 90 5 5 5 5 5 38 38 Max. Flow (L/min) /3/3 /3/3 47/37/5 58//3 55/43/8 /47/3 /47/3 /3/3 /3/3 53/37/5 //3 58/43/8 66/47/3 66/47/3 /3/3 55/43/8 /30/ /30/ /35/5 55/4/30 5/4/30 55/4/30 55/4/30 67/50/ 63/48/35 67/50/ 67/50/ 0//53 83/8/67 83/3/65 83/3/65 83/3/65 65/38/5 Max. Head (m) 4.5/3.8/.5 4.5/3.8/.5 4.5/3.8/.5 4.5/3.8/.5 4.5/3.8/.5 4.5/3.8/.5 4.5/3.8/.5 5.5/4.5/.8 5.5/4.5/.8 5.5/4.5/.8 5.5/4.5/.8 5.5/4.5/.8 5.5/4.5/.8 5.5/4.5/.8 6.0/4.5/.5 6.0/4.5/.5 4./3.5/.3 4./3.5/.3 4./3.5/.3 4./3.5/.3 4./3.5/.3 4./3.5/.3 4./3.5/.3 5.9/5.3/4. 5.8/5.3/4. 5.9/5.3/4. 5.9/5.3/4. 7./6.5/4.9 /9.7/5.4 Inlet/Outlet Dia.(m) Φ5 Φ5 Φ0 Φ Φ3 Φ5 Φ5 Φ0 Φ Φ3 Φ5 Φ5 Φ5 Φ0 Φ Φ3 Φ Φ3 Φ8 Φ4 Φ4 Φ4 Φ4 Φ8 Pipe size (inch).... 3.Product Structure ). Typical Structure Nameplate Discharge plug Terminal box Motor casing Speed switch LRP XX - XX X / XXX Sample: Inlet Outlet Distance between inlet and outlet No identification=cast iron pump body & threaded connection F=Cast iron pump body & flange connection B=Bronze pump body & threaded connection Max. Head (dm) Inlet/outlet ID. (mm) Pump body LEO Hot Water Recirculating Pump 7 4

). Appearance & Dimensions LRP5-/ LRP5-B/ LRP0-/ LRP5-/ LRP5-/ LRP3-/ LRP5-50/ LRP5-50B/ LRP0-50/ LRP5-50/ LRP5-50/ LRP3-50/ LRP5-K/ LRP5-K/ LRP5-/ LRP5-B/ LRP0-/ LRP5-/ LRP5-/ LRP3-/ LRP5-70/ LRP5-70/ LRP3-70/ LRP5-/ LRP3-/ LRP5-0/ 35 35 35 35 5 66 5 37 48 G G G. G G G G G G. G G G G G G G G. G G G G G G G G G Model A(mm) B(mm) C(mm) D C D A B 5 6 E D A B C LRP-F/0 LRP-50F/0 LRP-F/0 LRP-70F/0 0 0 0 0 Model A(mm) B(mm) C(mm) D(mm) M0 M0 M0 M0 E(mm) LRP3-F/0 LRP36-F/00 LRP-F/50 0 00 50 50 38 55 90 73 94.5 7 64 78 Model A(mm) B(mm) C(mm) D(mm) Φ9 9 Φ Φ E(mm) F(mm) Φ00 9 Φ 0 Φ 0