The revolutionary code-free system as easy as

Similar documents
Intelligent technology made simple

NAPCO FREEDOM F-8 CONTROL PANEL INSTALLATION INSTRUCTIONS. F-TP Touchpad

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

GEM-P800 Programming Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

PROGRAMMING INSTRUCTIONS

PROGRAMMING INSTRUCTIONS

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

RE6100 Series Helix Security and Automation Platform

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DOOR MONITORING/DURESS SYSTEM

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

First Alert 1200C Installer Notes M. Leuck

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

WIRELESS CONTROLS & DETECTORS

EVO192 v3.0 Fire and Burglary What s New

GEM-X255 CONTROL PANEL/COMMUNICATOR

DS7400Xi Addressable Control/ Communicator

The complete wirefree security alarm solution

ARMED STATUS NEXT/YES PRIOR/NO AREA. GEM-RP1CAe2 Keypad NEXT/YES PRIOR/NO AREA. GEM-RP2ASe2 Keypad

P Zone Expandable Hybrid Security System

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

INSTALLATION GUIDE XTLN-WIFI PANEL

Safewatch Pro 3000 System Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Property of Monitronics Inc

One panel offers everything you want built-in

Using your NAPCO FREEDOM. F-TPG Garage Touchpad Home Security System NAPCO 2005 PATENTED OI309 10/05 1

GEM-P3200 CONTROL PANEL/COMMUNICATOR

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

GEM-P1664EX CONTROL PANEL/COMMUNICATOR

USING DEVICE COMMANDS

Control/Communicator

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

StarLink SLE Commercial Series Dual-Path Alarm Communicators INSTALLATION INSTRUCTIONS

OPERATING GUIDE for your GEMC-BK1 KEYPAD

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

LYNXR-2 Series Security System

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

GEM-RP2AS/RP2ASe/RP2ASe2 Keypad

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

ADEMCO VISTA-12A ADEMCO VISTA-12E

Control/Communicator Installation Manual

TABLE OF CONTENTS TABLE OF CONTENTS 1

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Simon XTi Quick Operation Guide

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Using Your GEM-P400 Security System H

Contact ID as of 2/2/2015

Model 17A00 Expansion Enclosure

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Easy Series Intrusion Control Panel. Selection Guide

Wireless Security System

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

ADEMCO VISTA-48 SERIES

ITI Caretaker Basic Commands

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

ADEMCO LYNX XL SERIES Security System

User's Manual 5120XM N8031 6/96

D3D Wi-Fi GSM Smart Alarm System -User Manual

INSTALLATION MANUAL PC15OO

System Overview. PC4020 v3.3

User Manual. with LED Keypad. Alarm Control Panel CA10 plus (software version 4.7) GDAŃSK. ca10pldu_e 07/03

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

Property of Monitronics Inc

Installation Instructions

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Contact ID as of 11/28/2018

"Pegaso" wireless alarm system

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Security System. User s Guide for the Text Command Center

System Introduction. 1.1 Specifications

VISTA-100 Commercial Fire & Burglary Partitioned System

NX-4V2 Control Panel Installation Instructions

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

status AW1 Plus WiFi Alarm System User Manual

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

NetworX Series NX-4V2 Control Panel Installation and Startup

Installation Manual Premier 412/816/832. Issue 10

INSTRUCTION MANUAL PC255O

5HDG\*XDUG5 6HFXULW\6\VWHP 8VHU*XLGHIRU5HDG\*XDUG5. K5481-1V2 10/03 Rev. A OFF STAY ESCAPE AWAY ADD DELETE AUX STAY

OPERATING GUIDE for your GEM-DK1CA KEYPAD

Transcription:

NAPCO introduces a new revolution in home security By NAPCO Complete, standard Freedom F-8KIT1, shown Code-free F-8 security system with 8-zone hybrid control The revolutionary code-free system as easy as locking the door, eliminates callbacks, account attrition and 100% of false alarms caused during exit/entry (the times 85% all false alarms occur in traditional systems.) Napco s Freedom System installs in as little as an hour and uses all standard Gemini Wireless. Starting with a conventional, NAPCO downloadable 8-zone hybrid control, it features a unique, deadbolt lock interface and codeless, easy-install Freedom Touchpad with built in UL siren and built in UL pet PIR sensor. Nothing to touch on the door lock insert interfaces with existing deadbolt locks and transmits wirelessly. FREEDOM to sell and to attract the 78% of households that won t live with the hassles of using a traditional alarm.

Revolutionary code-free Freedom Touchpad is easy to use and multi-functional for meaningful installation and equipment savings The new revolution in security, so advanced it s simpler simpler for you to install; simpler for consumers to operate. Freedom to get more accounts and keep them, by maximizing customer satisfaction eliminating false alarms and attrition. 4-in-1 unit: One unit to mount/wire delivers functions of 4 devices English language touchpad with panics Indoor 95 db siren 25 Pet PIR Wireless receiver for both lock and front door contact built into wireless lock sensor Code-free touchpad controls system and displays lock status for up to 2 doors. For added convenience and value, each touchpad can be used with 2 wireless lock sensor/ transmitters to cover 2 doors. Touchpad in Kit + 2nd Door = Add-On Kit 2 Key Controlled Doors

So simple, it maximizes customer satisfaction and account retention Coming home? Unlock the door, the system turns itself off. Staying in or going to bed? Lock the door and press STAY. Leaving? Press AWAY, lock the door and go! (A tone heard outside confirms it s on.) 1 2 How do the components install & work together? Lock tab is easily inserted in 1. keeper/deadbolt receptacle in the door jamb. Lock tab is wired directly to 2. wireless lock sensor/transmitter (just a few inches) Touchpad mounts on wall, wired like standard keypad, 3. and its built-in receiver communicates wirelessly with lock sensor/transmitter(s).* Downloadable, Gemini-compatible, 4. panel works conventionally. * Up to 2 lock sensors can transmit to 1 touchpad (within 500 open air). 3 Nothing to touch on the door (cut-away view). Freedom lock tab (1) is simply inserted in deadbolt hole in door jamb, wired beneath moulding to wireless lock sensor (2). Lock status and door (open) status are communicated to touchpad s built in receiver (3). Patented. Code-Free Touchpads, Lock Interface & F-IFOBS: Touchpads feature built-in 95db UL siren and 25 UL Pet PIR Sensor with obtuse angle area coverage for easier, more expeditious installation. Max. Number of touchpads: 2 (2 of any kind, Standard F-TP, Bedroom F- TPBR or Garage F-TPG models) Max. number of code-free, key-controlled doors per F-8 System: 4. For installation ease, Freedom s lock tab simply inserts into the premises existing deadbolt lock receptacle (keeper) in door jamb, and wires under the door moulding approx. 24-36 to nearby wireless lock sensor mounted beside the door jamb (higher than touchpad). This enables both lock status and (closed) door status to be monitored by lock tab, and communicated to the lock sensor/transmitter (to which it s wired). The lock sensor/ transmitter sends this information wirelessly to touchpad s built in lock receiver. (Note: This is not applicable with the hardwire kit, F-8KIT-H, designed for prewire installations.) Using model F-2D Wireless Lock 2nd Door Interface kit offers both equipment- and labor-savings, since the lock status transmissions of up to 2 deadbolt door locks can be received by a single (1) Freedom Touchpad s built in, lock sensor. In this application, the user can come and go using the code-free, key-controlled system at either of two (2) doors, despite needing only one (1) touchpad in the installation. The F-2D Lock Interfaces, installed at the second door s deadbolt, however, must be within the touchpadreceiver s range of approximately 500-600 open air. (Note: Use of F-2D is not applicable with the hardwire kit, F-8KIT-H, designed for prewire installations.) Touchpads provide easy 3-step, consumer-friendly code-free operation, oversized buttons and a vivid, color-coded English language display (concealed pull-up zone directory, too.) Touchpad s built in siren will chirp to verify to consumer the Freedom system is armed, following their locking their door (programmable). Touchpads display deadbolt lock status (locked or unlocked), where a steady READY display indicates door(s) are locked and deadbolt is engaged. Touchpads feature 3 programmable 1-button panics, police, fire, auxiliary, operated as hold-down functions to prevent inadvertent alarm activation Touchpads feature programmable ambush and chime functions, too. Each of Freedom s Touchpads has a built in lock sensor receiver and can monitor the signal transmissions of up to 2 deadbolt door locks, using model F-2D. Touchpads have an integral alarm silencing port, which upon alarm, accepts any enrolled F-IFOB credential, silencing all system sounders. Maximum number of F-IFOB credentials: 5 per F-8 system Lost Key Mode Should a consumer have concerns over a lost key to their door lock, to prevent unauthorized security system disarming (using that misplaced key), they can simply activate (and later deactivate) Lost Key Mode with a 2-button sequence at their touchpad, disabling Freedom s key-controlled disarming. While temporarily in Lost Key Mode, ie., while a locksmith is called to rekey or replace their deadbolt lock, users can continue to fully operate their security system, however the F-IFOB credential must be inserted at the touchpad, when reentering the premises to disarm (instead of disarming with that lock s key.) Bedroom Touchpad, model F-TPBR, Bedroom Touchpad requires NO door lock on that room, and may only be used as a secondary touchpad in a system (see next page). Bedroom Touchpad, model F-TPBR, features NIGHT MODE which turns off its built in PIR to permit freedom of motion in that room while the system is armed. For hardwired installations, e.g., prewire installs,, use F-8KIT-H and/or F-TAB/TP-H containing touchpad with hardwired deadbolt lock interface. (This hardwire configuration does not support F-2D Wireless 2nd Door Kit and has a maximum of 2 key-controlled doors and 2 touchpads per system, ie., one per door.) As above, it does fully support the Garage and Bedroom Touchpad applications. Freedom s Garage Door Application is super easy, too (see next page).

F-8 Control Panel Features: 6 Programmable Hardwire or Wireless Zones, 2 Wireless Zones* and 2-Wire Fire (*Note: These 2 zones are hardwired when system includes a second Touchpad) Supports all Gemini Transmitters using Gemini GEMRECVXP8 Wireless Receiver 50 Event Log No exit/entry countdowns, eliminates user-caused false alarms when they most frequently occur. To prevent false alarms when arming, during a pre-arm period, the system looks for motion, in all its motion sensors and touchpad PIR sensors, and if detected, automatically converts to Armed STAY, (solely turning on perimeter protection). Programmable Telco Line-Cut and Bell-Cut Supervision Fuseless, maintenance-free operation PCD-WINDOWS PC Programmable (Version 5.2 or higher) including PC-Preset unattended downloading UL listed Communicator Features: All Major Communicator Formats including, Point ID, Ademco Slow, Radionics Slow/Fast, Silent Knight Fast, Universal High Speed, 4/2, etc. Double Reporting & Backup Reporting, including pager format Programmable Telco Line Cut & Bell Cut Supervision Downloadable Control Panel Restoral reporting: AC, Battery, Trouble, Fire Reporting: Low Battery, Opening/closing, conditional closing; system, zone report, tamper, wireless smoke supervisory and low battery System Specifications (with Wireless Lock Interface): Max. number of code-free, key-controlled doors, 4. Max. number of Freedom Touchpads (any): 2 Each of 2 Freedom Touchpads can monitor 2 door locks each, each using F-2D Wireless Lock 2nd Door Interface kit. (Note: Transmission range of F-2D Lock Interface to touchpad s built-in receiver is approximately 600 open air). Operating temperature: 0-49 degrees C (32-120 F) Input power: 16.5 VAC plug-in 20VA transformer Loop voltage: 5 Volts Loop current: 1.1 ma Loop resistance: 300 ohms per zone (max.) Alarm output: Burg: 12 VDC, 2A (max.) Fire: 12 VDC, 65 ma Combined standby current: 500 ma residential burglary (4 hour standby); 500 ma residential fire (4 hour standby); 120 ma residential fire (24 hour standby) Current limiting: Burg/fire: 2.25A Output: 2A, max.-burg; 125mA, max.-fire Maximum charging current: 165mA Housing: 8-3/8 x 10-1/4 x 3 (H x W x D) Required battery: 12V 4AH rechargeable (For Hardwired Freedom F-8 specs. see WI1430) Bedroom Touchpad provides easy control from the comfort of the bedroom. Allows users to arm/disarm their system and monitor deadbolt locked/unlocked status. Includes 1-button disarm/silence in night or stay modes. Night mode, turns on all interior devices, except PIR built into bedroom touchpad. No lock required in bedroom

Freedom s garage door application is as easy to install as it is to operate! Easy 3-step garage installation 1 Step 1. Wire Garage Touchpad beside interior garage entry door (just like a typical keypad). 3 2 Step 2. Garage Door Motor Sensor plugs in to garage door motor and wires to back of Garage Touchpad. Garage Kit and 2nd door add-on Add F-GDMS to kit for second garage door Step 3. Install standard overhead magnetic contact (of your choice) on garage door and wire to back of touchpad. It enables the system to detect the activation of the garage door and subsequent open/close of the contact on it to activate arming/disarming. Garage Door Kit, F-GKIT Simplest consumer operation with garage: Leaving Consumer presses AWAY on touchpad, gets inside vehicle, backs vehicle out of garage. When garage door closes, system arms. Optional chirp of siren can audibly confirm arming. Returning home Consumer opens garage normally, with standard garage door opener, and system automatically disarms.

Freedom System options and add-ons Add garage door w/touchpad F-GKIT Add 2nd auto. garage door F-GDMS Add garage touchpad, only F-TPG Add second door F-2D Add second door with touchpad F-TP/TAB Add bedroom touchpad (no lock required) F-TPBR Freedom ordering information: Choice of 3 starter kits with F-8 Hybrid Control and touchpad/lock interface: F-8KIT1 Complete Freedom Kit: Touchpad w/built-in siren, downloadable 8-zone hybrid control, wireless lock sensor, deadbolt tab, 3ea. F-IFOBs (for alarm silencing,only), transformer. (Kit supports 2 codeless, keycontrolled doors, expandable to 4 key-controlled doors.) F-8KIT2 Kit w/pir, as above, plus 45 65lb pet immune, microprocessor passive sensor, PIR1680PT F-8KIT-H Complete Freedom Hardwire Kit, ideal for prewire installations: Touchpad w/builtin siren, downloadable 8-zone hybrid control, hardwire lock sensor, deadbolt tab, 3ea. F- IFOBs (for alarm silencing, only), transformer. (as above in F-8KIT1, but with Hardwired lock interface. Maximum 2 codeless, key-controlled doors.) (See WI1430 for hardwire-compatible options, including F-TP/ TAB-H, below) Works with all Gemini Wireless components! Optional Gemini Accessories: GEM-RECV-XP8 Wireless 8 pt. receiver GEM-TRANS2 Window/door transmitter GEM-KEYF Gemini newly redesigned mini keyfob GEM-KEYFLR Long range Gemini keyfob (classic style) GEM-WP Wireless waterproof panic button GEM-SMK Wireless smoke detector GEM-HEAT Wireless heat detector GEM-PIR Wireless PIR GEM-PIRPET Wireless pet immune PIR GEM-RTRANS Wireless recessed transmitter GEM-DT Wireless dual technology sensor GEM-GB Wireless glass break detector Freedom F-8 System add-ons: See color-coded boxes at your distributor: Blue=Standard applications Purple=Bedroom applications Green=Garage applications F-TP/TAB Touchpad w/built-in siren & PIR, wireless lock sensor and deadbolt tab. F-2D 2nd Door Add-on Kit, includes all lock interfaces, ie., everthing needed for adding second door with deadbolt. F-IFOB Alarm-silencing credential fob (1) F-TPBR Bedroom touchpad w/siren and PIR (doesn t require deadbolt lock). F-GKIT Complete Garage Kit, with Garage Touchpad (F-TPG) and Plug-in Automatic Garage Door Motor Sensor (F-GDMS) for interfacing with one garage door. (containing 2 items (below). F-TPG Garage touchpad w/siren & PIR (for interior garage door entrance). F-GDMS Automatic garage door motor sensor (for adding a second automatic garage door, used in conjunction with F-GKIT) F-TP/TAB-H Hardwired secondary door kit with touchpad and wired lock interface. F-MTAB Mortise lock application tab F-DRILL Optional steel drilling jig tool F-PROG Optional keypad-style panel programming tool (not for installation) PCD-WINDOWS Windows panel dowloading software, Version 5.2 (or higher) For an online demo of FREEDOM by Napco go to www.napcoinsider.com 1-800-645-9445 631-842-9400 www.napcosecurity.com email: hotline@napcosecurity.com NASDAQ: NSSC NAPCO, 11/05. Specifications subject to change without notice. NAPCO Freedom is a trademark of NAPCO. Patented A505