Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Similar documents
The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Consultant Specification AGILE Wireless Fire Detection System

Wireless Fire & Security Solutions. Fire Product Showcase

Analogue addressable devices

Intelligent addressable fire alarm control panel

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Product Guide MAN7030-2

Addressable and Conventional Fire Protection

Evolution Analogue Addressable Fire System

Solution F2. Fire Alarm Control Panels one step ahead.

Sita200plus. 200detectors. Single loop analogue addressable System

The new detector from Rafiki

Wireless Fire & Security Solutions. Fire Product Showcase

Eurotech is an established name, one that matters in supplying the latest in fire detection technology to save lives and businesses.

MINERVA MZX125 Digital Addressable Fire Detection System

Fire Product Catalog

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

MINERVA MZX125. Digital Addressable Fire Detection System

Cerberus FIT conventional system

Vega Devices.

Intelligent Security & Fire Ltd

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Intellia Sounder Bases and Sounder Beacon Bases

Touch Screen 1 loop Addressable Fire Alarm Panel

Quick Selection Guide Fire Systems LSN Periphery

A Guide To BS Understanding the selection, spacing and siting of detectors

EFBW series - BiWire Ultra control panel

OH110, OP110, HI110 Automatic fire detectors

Wireless Fire Solutions

Addressable Loop Powered Visual Alarm Devices

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

ID50series. intelligent fire alarm panels

Fire Signalling. Signalling Solutions

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

>WIRELESS> ALARM SYSTEM CR200

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

XP95 Sounder VAD Base

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

IFD-E Flame Detector User Manual

Apollo Accreditation. Need further information? Visit

The complete conventional fire warning system

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

4 wire conventional alarm system

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Reflective Optical Beam Smoke Detector User Guide

5000 INSTALLATION GUIDE

IFD-E Flame Detector User Manual

Fiber Optic Cable Fence Disturbance Sensor

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

INPUT / OUTPUT MINI MODULES

Open-area Smoke Imaging Detection (OSID)

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Conventional Fire Alarm System 2014 V1.2

Hardwired Alarm Accessories

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

An introduction to... Sigma

Contents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

The supplier and installer of the system should be approved by the local civil defence authority.

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Solution F1. Fire Control Panels the new generation

XC10 combined fire detection and extinguishing control

Panel XTO210/610/710 GPRS

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

intelligent fire alarm ID60series panels

Emergi-Lite Orbis detectors

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

LaserFOCUS VLF-250 Engineering Specification

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

DATAssure. Laboratory wireless alarm & monitoring system

XC10 Extinguishing control panels

Analogue Detectors. Series 200 plus

Australia s Advanced Fire System

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

DCS-100. intelligent damper control & monitoring system

EMERGENCY ASSISTANCE ALARMS

Hochiki Devices. It also highlights any specific requirements and technical information.

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

DUR-4047 WIRELESS RADIO UNIVERSAL SMOKE OPTICAL DETECTOR

World Class Leaders in Fire Detection Since PRODUCTCATALOGUE Fire Detection Solutions

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

IQ8Control C Fire Alarm Panel

Fire Detection - Addressable

ENGINEERING PRODUCT GUIDE

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Opal TM AV Devices. Data Sheet. Benefits

Our technology, your peace-of-mind. Product list

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

intelligent solutions

Fire Signalling. Signalling Solutions

Addressable Fire Alarm Control System 2100 series

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Protecting you and your home

INTELLIGENT FIRE TECHNOLOGY

Smoke Vent Control Panel PCB4 V4 Installation Manual

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Transcription:

Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless integration provides the user with maximum flexibility in configuring the system to meet the specific needs of the building into which it is to be deployed. FIREwave employs the latest technology, providing a simple and economic wireless fire detection system installation with minimal disruption to the fabric of the building and its operation. Flexible and versatile, FIREwave is suited to a wide range of applications, matching the requirements of any building from busy hotels to sensitive heritage buildings. FIREwave is the most flexible fire detection solution available that is simple to install and maintain, overcoming installation and maintenance challenges on the most demanding sites; advanced patented technology is used to achieve optimum performance. Operation Through patented and proven wireless technology, FIREwave is built around intelligent Translator and Expander Modules and the advanced wireless communication protocol facilitates the delivery of fully intelligent field device integration, allowing analogue values, device addresses and type codes to be transmitted to the system control panel. Powered directly from the detection loop, Translator Modules ensure a reliable and secure connection between the field devices and control equipment. Each Translator Module can support up to 32 field devices (maximum 16 output) via the proven wireless protocol. Communication between the Translator Module and devices is bi-directional and uses the 868MHz frequency range in Europe, 916MHz in Australia and 433MHz in India. Automatic system adjustments, including channel hopping and signal amplification, are implemented to support the security and stability of communications. Each field device has a range of 100m in free air, but greater distances and complex architecture can be addressed with Expanders to extend the coverage area the signals transmitted, allowing FIREwave systems to be configured to any size and complexity. All FIREwave devices are powered by standard lithium batteries which are both economical and environmentally friendly. Dependant on design and device type, a battery life of up to five years can be anticipated from the primary cell, with a further two months of operation from the support cell. All FIREwave batteries are monitored continually, and any low battery condition is automatically displayed at the control equipment. FIREwave sensors are supplied in three variants: Optical, Thermal and Multi Criteria, which cover a wide range of applications. The Optical and Multi Criteria detectors feature double dust traps and adaptive signal processing to prevent false alarms. Thermal detectors can respond to a fixed temperature threshold, or detect a rate of rise in temperature. The range of FIREwave devices provides a visually attractive wireless fire detection solution, encompassing a wide variety of installation types and sizes. Wall and base mounted audio devices have adjustable volume levels and multiple tone settings, and are available as stand-alone Sounders, or as combined units. Wall mounted units can be supplied in red or white, and weatherproof options are also available. Features Advanced, patented wireless technology ensures optimum system performance Expandable: configurable to any size and complexity of building Simple to install: fast deployment, with minimal disturbance Flexible and versatile: suits all building types 95

Wireless sensors Sensors The FIREwave intelligent wireless sensors come in three variants, Photoelectric/Optical (Smoke), Thermal (Heat) and Multi Criteria (Smoke & Heat). All devices are compatible with the FIREwave Loop Translator Modules and Expander Modules. The detectors parameters are programmed via the Translator Module (RSM- WTM-AS) via a PC link. The Translator Module then automatically manages detector radiated power depending on the device communication quality. Each sensor can then automatically adjust its frequency and radiated power output in accordance with the signal quality received from the Translator Module. The patented smoke chamber of the ROD-E-AS and RMD-E-AS ensures optimal smoke sensitivity from all directions, whilst the double dust trap provides the chamber with increased protection from airborne contamination and background illumination. Each sensor is fitted with a reed switch facility allowing testing using a magnet. Bi-directional wireless communication with self optimising wireless frequency and amplitude Adaptive signal processing helps with the elimination of false alarms. Automatic wireless channel hopping Fully intelligent with high reliability and sensitivity Flexible on site device adjustment Makes additions to existing wired systems easy and cost effective Utilises standard low cost lithium battery technology Fully monitored primary and secondary power sources Compliant with AS7240-5/7/11 & AS4428-9 standards Temperature compensation algorithms ensure a reliable and stable operation across a wide temperature range 96

Wireless sensors www.incitefire.com.au Ordering Codes Photoelectric Smoke Sensor Heat Sensor ROD-E-AS Multi Sensor RMD-E-AS Communication range with the Translator Module 100M (open space) Number of operating channels 7 Time period between wireless signal transmissions From 12 seconds to 2 minute Power supply (dual 3V lithium batteries) 1 x Primary Cell (CR123A) Capacity 1.2Ahr 0.24Ahr Estimated battery life 5 years 2 months RHD-E-AS 1 x Secondary Cell (CR2032A) (dependant on time period between wireless signal transmissions) Operating temperature range -30ºC to +50ºC 0.01 to 3mW QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 97

Wireless audio/visual Audio/Visual The FIREwave base mounted Audio Visual devices provide a visually attractive and cost effective solution for a wide variety of wireless installation types and sizes. The Base Sounder (RSM-BS-AS) and Base Sounder Beacon (RSM-BSB-AS) parameters are programmed via the Translator Module (RSM-WTM-AS) and conventional interface modules via a PC Link. The Translator Module then automatically manages wireless radiated power depending on the device communication quality. All Audio Visual devices are controllable from the Control Panel via the Translator Module and offer the same level of flexibility as a standard addressable loop sounder RSM-BS-AS Base Sounder* Both units feature 32 tone settings as standard with two volume settings allowing adjustment up to 92dB (A) at 1 metre. Both units also come with a pre-moulded base which will accommodate any type of FIREwave wireless detector, or can be removed to accomodate a locking cover plate. Bi-directional wireless communication with self optimising wireless frequency and amplitude Automatic wireless channel hopping Fully intelligent and highly reliable Flexible on site device adjustment RSM-BS-AS Base Sounder** Makes additions to existing wired systems easy and cost effective Utilises standard low cost lithium battery technology Fully monitored primary and secondary cells Compliant with AS4428-9 and AS7240. Temperature compensation algorithms ensure a reliable and stable operation across a wide temperature range *shown with sensor - supplied separately **shown with cap - supplied separately 98

Wireless audio /visual Ordering Codes Base Sounder Base Sounder Beacon Base Sounder Cover Communication range with the Translator Module Number of operating channels Time period between wireless signal transmissions Power Supply (dual 3V lithium batteries) Capacity Estimated Battery Life (dependant on time period between wireless signal transmissions) Operating Temperature Range Radiated Power Sounder Output (selectable) RSM-BS-AS RSM-BSB-AS RSM-C-AS 100M (open space) 7 From 7 seconds to 1 minute 1 x Primary Cell (CR123A) 1 x Secondary Cell (CR123A) 1.2Ahr 1.2Ahr 3 years 3 months - 10ºC to +50ºC 3mW (typical) 88 to 92dB (A) at 1 metre 99

Wireless audio/visual Audio/Visual The FIREwave wall sounders are fully intelligent wireless alarm signalling units, providing a signalling solution for a wide variety of system sizes and types. Sounder parameters are programmed via the Translator Module (RSM- WTM-AS) and conventional interface modules via a PC Link. The Translator Module automatically manages sounder radiated power depending on the device communication quality. All wall sounders can then adjust their frequency and radiated power output in accordance with the signal quality received from the Translator Module. The Sounders come as standard with three tones and are fitted with a volume control which is adjustable up to a maximum output of 100dB(A). All devices are fully controllable from the Control Panel via the Translator Module and offer the same level of flexibility as a standard addressable loop sounder. Bi-directional wireless communication with self optimising wireless frequency and amplitude Automatic wireless channel hopping Fully intelligent with high reliability and sensitivity Flexible on site device adjustment Easy and cost-effective additions to existing wired systems Utilises standard low cost lithium battery technology Fully monitored primary and secondary power sources 10 variants of wall sounder available including weatherproof Compliant with AS4428.9 and AS7240 Temperature compensation algorithms ensure a reliable and stable operation across a wide temperature range * (also available in white) ** (also available in red) 100

Wireless audio /visual www.incitefire.com.au Ordering codes Standard Wall Sounders Weatherproof Wall Sounders Standard Wall Sounder Beacons Weatherproof Wall Sounder Beacons Communication range with the Translator Module Number of operating channels Time period between wireless signal transmissions Power supply (dual 3V lithium batteries) Capacity Estimated battery life* Operating temperature range Maximum sound output (adjustable by 20dB) Flash rate / Light output (Beacon only) IP Rating RSM-WS(RED)-AS RSM-WS(WHT)-AS RSM-WS/W(RED)-AS RSM-WS/W(WHT)-AS RSM-WSB(RED)-AS RSM-WSB(WHT)-AS RSM-WSB/W(RED)-AS RSM-WSB/W(WHT)-AS 100M (open space) Frequency Modulation 7 From 7 seconds to 1 minute 1 x Primary Cell (CR123A) 1 x Secondary Cell (CR123A) 1.2 Ahr 1.2 Ahr 3 years 3 months -10 ºC to +50 ºC (standard) -25 ºC to +50 ºC (weatherproof ) 0.01-3 mw 100 db (A) at 1 metre 1 Hz / 1 Cd IP21C (standard) QLD 07 3252 5366 NSW 02 9644 7144 IP66 (weatherproof ) VIC 03 9544 2211 101

Wireless expander module Expander Module The RSM-EXP-AS Expander Module increases radio coverage of a FIREwave RSM-WTM-AS Translator Module, and conventional interface module allowing the use of the system in larger buildings and in difficult wireless environments. Multiple Expanders can be utilised in a micro cell structure to provide a solution to large, complex systems. Up to 7 Expander Modules may be configured to any one Translator Module and conventional interface module forming a micro cell cluster. Each cluster can be programmed with up to 32 radio field devices. These devices can comprise of any combination of detectors, call point and input modules and include up to 16 sounders and output devices. The Expander Module relays the intelligent device information from the field devices to the Loop Translator Module using a highly stable bi-directional radio communication protocol. The system parameters are programmed into the Expander Module via an RS232 PC link. The unit is housed in an IP65 housing making it suitable for mounting in a wet environment or outdoors and is also fitted with two orthogonal antennae, reducing signal fading and ensuring reliable radio communications. Bi-directional wireless communication with self optimising wireless frequency and amplitude Microcell technology allows flexible system design and improved performance on all sizes of system Fully compatible with all FIREwave devices Easy and cost-effective additions to existing wired systems IP65 protection for exterior mounting 102

Wireless expander module Ordering code Communication range with the field devices Communication with RSM-WTM Translator Module Number of operating channels Time period between wireless signal transmissions Operating temperature range Current consumption Operating voltage IP Rating RSM-EXP-AS 100 m (open space) 200 m (open space) 7 From 7 seconds to 2 minutes -30 C to +50 C 0.01-10 mw 15 ma 10-27 V dc IP65 103

Wireless translator module Translator Module RSM-WTM-AS * Loop Powered * Bi-directional wireless communication * Self optimising wireless amplitude and frequency * Automatic wireless channel hopping * Fully intelligent * High reliability and sensitivity * Flexible on site device adjustment * IP65 protection for exterior mounting * Makes additions to existing wired systems easy and cost effective * Compliant with AS4428-9 * SAI Global Approved Description The RSM-WTM-AS is a fully intelligent wired to wireless Translator Module. Completely compatible with the Hochiki ESP protocol, the module allows the use of fully intelligent radio (wireless) field devices alongside standard hard wired devices. The Translator Module allows the connection of up to 32 radio field devices to an addressable fire detection loop. Multiple Translators can be used on a system providing the system has sufficient loop addresses avaliable. Each radio field device takes a loop address making them fully intelligent and their radio connectivity transparent to the end user. System parameters are programmed via the Translator Module and a PC link. The Translator Module automatically manages detector radiated power depending on the device communication quality. The module is housed in an IP65 housing making it suitable for mounting in wet environments and outdoors. The unit is fitted with two orthogonal antennae which reduce radio fade and ensure reliable radio communication. Ordering Codes RSM-WTM-AS Communication range with the field devices 100 m (open space) Communication with RSM-EXP Expander Module 200 m (open space) Number of operating channels 7 Time period between wireless signal transmissions From 7 seconds to 2 minutes Operating temperature range -30 C to +50 C 0.01-10 mw Current consumption 38 ma Operating voltage 15-42 V dc IP Rating IP65 Dimensions (mm) H160 (240 with antenna) x W120 (200 with antenna) x D50 104

Wireless manual call point Manual Call Point RSM-CP-AS * Bi Directional wireless communication * Fully intelligent * Utilises standard low cost lithium battery technology * Long battery life * Resettable Element * Clear device activated warning flag * High reliability * Automatic channel hopping * Self optimising wireless amplitude and frequency * Compliant to AS4428.9 * SAI Global Approved Description The RSM-CP-AS is a Wireless Resettable Manual Call Point which features a simulated glass front. When activated, a plastic flag is displayed in the window of the unit; the supplied key will reset the flag and unit. Supplied with back box. Weatherproof version also available (RSM-CP/W-AS). The units parameters are programmed via the Translator Module via a PC link. The Translator Module then automatically manages detector radiated power depending on the device communication quality. Each unit can automatically adjust its frequency and radiated power output in accordance with the signal quality received from the Translator Module. Ordering Code RSM-CP-AS Communication range with Translator Module 100 m (open space) Number of operating channels 7 Time period between wireless signal transmissions From 12 seconds to 2 minutes Power supply (dual 3V lithium batteries) 1 x Primary Cell (CR123A) 1 x Secondary Cell (CR2032A) Capacity 1.2 Ahr 0.24 Ahr Estimated battery life* 5 years 2 months Operating temperature range -30 C to +50 C 0.01-10 mw Dimensions (mm) H87 x W87 x D23 (D58 with back box) 105

Wireless single channel input module Single Channel Input Module RSM-IP-AS * Input circuits are monitored for fire and fault conditions * Bi-directional wireless communication * Self-optimising wireless amplitude and frequency * Automatic wireless channel hopping * Fully intelligent * High reliability and sensitivity * Flexible on site device adjustment * Makes additions to existing wired systems easy and cost effective Description The RSM-IP-AS is a Single Channel Input Module providing a convenient and cost effective solution for monitoring and controlling third party equipment. Module parameters are programmed via the Translator Module (RSM- WTM-AS) which then automatically manages radiated power depending on the device communication quality. All modules can then adjust their frequency and radiated power in accordance with the signal quality received from the Translator Module. The unit is mounted in a protective IP65 housing for mounting in hostile conditions and to enable the termination of fire protected cabling. The module allows the connection of third party equipment to the fire system via the monitored input circuit. The module is also controllable from the Fire Control Panel via the cause and effect programming and offers the same level of flexibility as a standard addressable module. Ordering Code RSM-IP-AS Communication range with Translator Module 100 m (open space) Number of operating channels 7 Time period between wireless signal transmissions From 12 seconds to 2 minutes Power supply (dual 3V lithium batteries) 1 x Primary Cell (CR123A) 1 x Secondary Cell (CR2032A) Capacity 1.2 Ahr 0.24 Ahr Estimated battery life* 5 years 2 months Operating temperature range -10 C to +55 C 0.01-3 mw IP Rating IP65 Dimensions (mm) H95 x W135 x D23 (D58 with back box) 106

Wireless single channel output module Single Channel Output Module RSM-OP-AS * Contacts can be configured as N/O or N/C * Bi-directional wireless communication * Self optimising wireless amplitude and frequency * Automatic wireless channel hopping * Fully intelligent * High reliability and sensitivity * Flexible on site device adjustment * Makes additions to existing wired systems easy and cost effective * Requires external power supply Description The RSM-OP-AS is a Single Channel Output Module providing a convenient and cost effective solution for monitoring and controlling third party equipment. Module parameters are programmed via the Translator Module (RSM- WTM-AS) which then automatically manages radiated power depending on the device communication quality. All modules can then adjust their frequency and radiated power in accordance with the signal quality received from the Translator Module. The unit is mounted in a protective IP65 housing for mounting in hostile conditions and to enable the termination of fire protected cabling. The module allows the connection of third party equipment to the fire system via the monitored input circuit. The module is also controllable from the Fire Control Panel via the cause and effect programming and offers the same level of flexibility as a standard addressable module. Ordering Code RSM-OP-AS Communication range with Translator Module 100 m (open space) Number of operating channels 7 Time period between wireless signal transmissions From 12 seconds to 2 minutes Power supply (dual 3V lithium batteries) 1 x Primary Cell (CR123A) 1 x Secondary Cell (CR2032A) Capacity 1.2 Ahr 0.24 Ahr Estimated battery life* 5 years 2 months Operating temperature range -10 C to +55 C 0.01-3 mw IP Rating IP65 Dimensions (mm) H95 x W135 x D23 (D58 with back box) 107

Wireless powered output module Wireless Powered Output Module RSM-POM-AS * Contacts can be configured as N/O or N/C * Selectable output - 12 V dc or 24 V dc * Bi-directional wireless communication * Self optimising wireless amplitude and frequency * Automatic wireless channel hopping * Fully intelligent * High reliability and sensitivity * Flexible on site device adjustment * Makes additions to existing wired systems easy and cost effective * Powered via two lithium batteries and no PSU is required. Description The RSM-POM-AS is a Wireless Powered Output Module which allows the control panel to activate/switch the circuits of an external device or system wirelessly via an RSM-CIM-AS, RSM-EXP-AS or RSM-WTM-AS. The unit s contacts can be configured to be normally open or normally closed and switch at 30 V dc/125 V ac at 2 A. The unit can be configured to provide either a 12 V dc or a 24 V dc output. Module parameters are programmed via the Translator Module (RSM- WTM-AS) which then automatically manages radiated power depending on the device communication quality. All modules can then adjust their frequency and radiated power in accordance with the signal quality received from the Translator Module. The unit is mounted in a protective IP65 housing for mounting in hostile conditions and to enable the termination of fire protected cabling. The module allows the connection of third party equipment to the fire system via the monitored input circuit. The module is also controllable from the Fire Control Panel via the cause and effect programming and offers the same level of flexibility as a standard addressable module. Ordering Code RSM-POM-AS Communication range with Translator Module 100 m (open space) Number of operating channels 7 Time period between wireless signal transmissions From 12 seconds to 2 minutes Power supply 10-27 V dc (external) Operating temperature range -10 C to +55 C 0.01-3 mw IP Rating IP65 Dimensions (mm) H87 x W87 x D23 (D58 with back box) 108

Wireless overview www.incitefire.com.au QLD 07 3252 5366 NSW 02 9644 7144 VIC 03 9544 2211 109