Effluent Monitoring. Solutions

Similar documents
SECTION ph/orp Sensors

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Free/Available Chlorine Analysis System

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Diagnostics with fieldbus

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Hydrazine Analyzer Series 2171 Specifications

OMA-300 Process Analyzer

Rinse connection adapter CPR 40

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

APPLIED. OMA-406R Rackmount Process Analyzer

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

A New Standard of Excellence

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Dissolved Oxygen Measurement liquisys M COM 223 / 253

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

HIGH CAPACITY PRODUCT LINE

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Model Q45P/R. ph/orp Monitor...

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

ENERGY SAVING SEIBU GIKEN DST

L automazione al servizio della manutenzione

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Model Q45P/R. ph/orp Monitor...

Contamination Control for Electronic and Semiconductor Applications

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

An Introduction to KC Controls Ltd

Concise catalogue Water-Industry

Products and performance

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

SITRANS F M MAG 3100 P:

VM-3000 Mercury Vapor Monitor

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Rotary Screw Compressors SM Series

Foundation Fieldbus Usability from field Device Perspective. Hemal Desai Endress+Hauser India Pvt. Ltd 16 th October 2014 Automation 2014 Mumbai

Turbimax CUE21 / CUE22

HIGH CAPACITY PRODUCT LINE

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Monitoring Solutions

vanwaltconnect VAN WALT Monitoring your needs

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Dissolved Oxygen Measurement liquisys S COM 223 / 253

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Continuous, real-time detection, alarming and analysis of partial discharge events

Intelligent alarm management

Figure 1 DirectLine DL423 Sensor. Description, continued

Ion Gateway Cellular Gateway and Wireless Sensors

UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

FDT DTM and eddl. Technology Overview Peter Overgaauw - Honeywell

AS950 PORTABLE SAMPLERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Building system automation. How to use

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Integrated Process Solutions. Series 49. Thermal Management System

Industrial Grade Gas Detection

Screw Compressors SM SERIES. Capacities from: 19 to 54 cfm Pressures from: 80 to 217 psig

DISSOLVED GAS ANALYZER (DGA)

Technical Information OUSBT66

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

INC. DESIGN AND INTEGRATION OF ADVANCED SYSTEMS. Multipli Cité REMOTE WATER TREATMENT MANAGEMENT SYSTEM

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

PURSense Sanitary Flange Conductivity Sensors

For Complete Fire and Gas Solutions

Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Liquiline M CM42. Technical Information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Model D12-IR. Digital Gas Transmitter...

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations

Products and systems

The Professionals in Instrument Technology

PROCESS CONTROL COURSES

Dräger X-zone 5500 Area Monitoring

PART 1 - GENERAL 1.1 WORK INCLUDED

Flexible Air-sampling Smoke Detection

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

Mercury Vapor Monitor VM-3000

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Transcription:

Products Solutions Effluent Monitoring Solutions Avoid Unnecessary Fines Services

Effluent Monitoring Solution Overview Our effluent monitoring solution consists of a base package with a redundant ph system. Three ph measurements are analyzed in our CM44P transmitter to output the average of the two closest values, with an alarm being sent if any one drifts out of tolerance. Includes commissioning, remote monitoring and reactive service support. QTY 1 Complete panel with UPS QTY 1 CM44P panel mount transmitter with data logging, and Chemoclean Plus software QTY 3 CPS11D ph sensors, 225 mm version with ion trap for long service life and fouling resistance QTY 1 CYC25 Cleanfit controller with CYR10 cleaning fluid injector QTY 3 CPA871 retractable assemblies Remote monitoring and email/sms alarming with FXA42 Fieldgate On-site commissioning and reactive service support Options Total suspended solids monitoring with optical sensor Product loss detection with absorption sensor CSF34 fixed or CSP44 portable sampler Remote access FieldCare CM44P web server 4-20mA connection to customer control system Product loss detection Redundant ph sensors CM44P Modbus TCP/IP Web server Local display Total suspended solids FXA42 SupplyCare Email alerts SMS alerts (only on cellular models) Web HMI With accessory HG1+ Injector Cleanfit Control ph sensor with retractable assembly Sampler

The ph drift challenge Ensuring that your ph probes are reading accurately and have not drifted is the most common effluent monitoring challenge. To help you meet your challenge we have developed a system with built-in redundancy. Three separate ph measurements are constantly read and analyzed in our CM44P transmitter. The output is the average of the two closest values. An alarm is sent if any one of the sensors drift out of tolerance. Three Orbisint CPS11D digital Memosens sensors are used with the optional ion trap technology which extends sensor life by reducing the effects of fouling. The extended sensor length design is employed as they carry more electrolyte in reserve which also extends sensor life. The system is equipped with an automated cleaning system CYC25, which controls the retraction of the probes for cleaning with water and cleaning solution. The system also includes our innovative Fieldgate FXA42, which seamlessly pushes your critical information to a host of web based interfaces including SMS and email alarming. Remote access to the system will allow our technicians to assess and decide on an appropriate course of action, whether that may be to initiate a cleaning process remotely or to dispatch a technician to site. CPS11D Orbisint Memosens Digital ph Sensors Robust electrode with long poison diffusion path Low maintenance due to large, dirt-repellent PTFE ring diaphragm Corrosion and moisture resistant inductive design Digital memory allows pre-calibration 225 mm length for longer service life Ion trap for resistance to fouling CM44P Liquiline Transmitter Connection of up to 2 optical sensors Up to 4 Memosens Sensors with data storage and automated recognition Digital communications HART, Profibus, Modbus, Ethernet I/P and web server Data logging 8 x 150,000 points, fully configurable Automatic sensor cleaning, PID controllers x 2 and full diagnostics CYC25 Cleanfit Control Automated cleaning eliminates downtime (measurement on hold) Automated restart after shutdown or maintenance Direct control of CPA871 for sensor retraction and cleaning With CYR10 Injector to inject cleaning fluid Direct link to CM44P CPA871 Pneumatic Retractable Assemblies Robust assembly designed for long maintenance free operation Highest operational safety with intelligent functions that prevent any leakage of medium during operation, cleaning or calibration.

Know what s happening at all times A simple interface allows all data to be securely communicated with an FXA42 Fieldgate. It enables visualization of all measured values via an integrated web server and allows specified emails or SMS messages to be sent to key personnel when measurements are out of tolerance. FXA42 Remote Monitoring Fieldgate Limit value monitoring with alarming by email or SMS web server Simple configuration and easy visualization of measured values via its integrated web server Supporting communication interfaces Ethernet, WLAN as well as 3G Ethernet system link to CM44P Four 4...20mA input channels, four digital input and output channels Add other functions to your remote monitoring solution Product loss detection and suspended solids measurements made simple In many effluent streams an optical absorption sensor can be correlated to detect high product concentrations. This combined with total suspended solids measurement can give important insight into your effluent over time. We will aid you in determining the best optical absorption or turbidity sensor to use for your particular effluent requirements. TSS Total Suspended Solids Measurement CUS51D The addition of a turbidity sensor allows continuous monitoring of the total suspended solids in your effluent stream. Pre-calibrated and pre-configured from the factory Highly reliable and accurate four beam alternating light sensor Robust, low-maintenance design with self-cleaning functionality Product Loss Detection OUSAF11 An optical absorption sensor can be added for detection of product loss incidents in the effluent stream. Low-maintenance long-life sensor offering stable operation Robust sensor resistant to aggressive chemicals and fouling

Easy to maintain sampling systems Automate your effluent sampling with an easy to maintain solution. The CSF34/ CSP44 offers the widest range of programmable sampling techniques and is based on the modular Liquiline / Memosens architecture. It is the only sampler on the market with digital communications and integrated online sensors. Integrated sensors enable the sampler to move from being just a collector to operating as a full monitoring station and a state of the art instrument. The integrated sensors facilitate alarm based sampling to draw extra samples when out of range conditions are detected. Vacuum pump for accurate and highly repeatable sample volumes Peristaltic pump for short intake hoses, and variable sample volumes Accepts up to 4 Memosens analytical sensors Digital communications HART, Profibus, Modbus, Ethernet I/P Web server communications Data logging 8 x 150,000 points, fully configurable

www.ca.endress.com Endress+Hauser Canada Ltd 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel: 905 681 9292 1 800 668 3199 Fax: 905 681 9444 Endress+Hauser Canada Ltée 6800 Côte de Liesse Suite 100 St-Laurent, QC H4T 2A7 Tél: 514 733 0254 Téléc.: 514 733 2924 Endress+Hauser Canada Ltd Suite 110, 703 64 Avenue SE Calgary, AB T2H 2C3 Tel: 403 777 2252 1 888 918 5049 Fax: 403 777 2253 Endress+Hauser Canada Ltd 9045 22 Avenue SW Edmonton, AB T6X 0J9 Tel: 780 486 3222 1 888 918 5049 Fax: 780 486 3466