UV Biological Pond Filter. Inlet /Outlet Size

Similar documents
Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

EASYCLEAR 3000 YEAR GUARANTEE

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

EasyClear 3000/ YEAR GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

6000/7500/ YEAR GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Pond Oxygenator. Single / Twin / Four.

6000, 8000, & 15000

SimplyClear Pressurized Filter Product Manual

AllClear G2 Series Pressurized Filters Product Manual

GARDENA. F 3000 Art F 6000 Art F 9000 Art F Art. 7929

pond and garden LED feature light

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

PHOTECH AMPHIBIOUS PA35/PA320/PA520 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

PondoPress 10000, 15000

Pressurized Filter Up to 1250 gallons

AquaReef Cube. Inspiring Excellence in Fish Keeping!

Instructions. DBE_INS_A.indd 1 08/11/ :58

1.8l Rice Cooker. Instruction Manual

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

WARNING: Ensure that the unit is switched off at the mains before you attempt to conduct any type of maintenance on the evouv.

IMPORTANT: RETAIN FOR FUTURE REFERENCE

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

Hand Dryer Installation & User Manual

Refresh & Clean Carpet Washer

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

Instructions for Use. Record Player in Suitcase PARTS:

Flomate Mains Boost Pump Installation & Maintenance Instructions

SUBMERSIBLE DIRTY WATER PUMP

IMPORTANT: RETAIN FOR FUTURE REFERENCE

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

6 in 1 Combi Grill. GCCGPO_IM_A.indd 1 18/04/ :06 TEMP TIME

BLOW DRY & GO HAIR KIT

60cm Chimney Extractor

Mobile Air Conditioner Instruction Manual Model TC-N9KM

MILK FROTHER INSTRUCTIONS FOR USE

Academy The Straightener IM.indd 1 24/06/ :10. Instruction Manual LSHS16

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Multifunctional Food Processor User guide

Next Generation Corona Discharge Installation & Operation Manual

GUH52SD 52 cm GUH75 75 cm Canopy Hood

When using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference:

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

User Manual. Chest Freezer ZFC26500WA

SH3020 USER INSTRUCTIONS

Your Blast Vac Pro. Your Blast Vac Pro

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

SUBMERSIBLE WATER PUMPS

WC2 & WC3 Installation & Maintenance Instructions

18 Piece Roller Set. Model 9033U

SP16. 08/50740/1 (UK) - Issue 1

BioMaster 250/350/600 BioMaster Thermo 250/350/600

NEW. The automatic choice for your pond

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

AEM EASY DRUM M A N U A L

Model No: Little Devil II (inc ss)

Model CWA200 Owner s Manual

Compact Cyclonic Bagless Upright Vacuum Cleaner

1,500 2,500 4,500 9,000 14,000 20,000 30,000 50,000 1,000 1,000 2,000 3,000 4,000 8,000 12,000 18,000 N/A PF2500 (NO UVC)

Turbo Lite Corded Handheld Stick Vacuum

Heated Display. Instruction manual. Model: CW147 / CW148

DYSON CUSTOMER HELPLINE

1300W Pressure Washer RACHP133A

Electronic 30 Watt UV-A Lamp Indoor

Heavy Duty Pressure Washer 150

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

CG60/ 70/ 80/ 90/ 100 SS/BK

GEH9026G Cooker Hood

Do not leave the appliance unattended whilst connected to the mains supply. Always use this appliance on a solid, level, non-flammable surface.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

When using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference:

UV I UNIT030W / UV I UNIT055W

LARDER Instruction booklet

Electrisaver User and Installation Instructions

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

BLACK MAGIC BAB6669BU

When using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference:

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

identity installation & maintenance instructions customer/technical services guarantee

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Contact Details. Please note that some of the contact details on this PDF document may not be current.

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

PURE AQUARIUM KIT. Instruction manual. Manuel d instructions Bedienungsanleitung Handleiding руководство по эксплуатации

4L Instant Water Boiler Instructions for Use

AQUARIUM HEATER RANGE AH-25 / AH-50 AH-100 / AH-200 AH-300

Complete Cleaning System

Transcription:

EasyFilter PXPF04500 PXPF12000 UV Biological Pond Filter PXPF20000, PXPF30000 Model Power Rating Dimensions Diamtr x hght Inlet /Outlet Size Max Pond Vol. (Ltrs) Rec. Pump PXEF04500 7W 270 x 370 12/20/25mm 4,500 PXFP03000 PXEF09000 9W 340 x 440 20/25/32/40mm 9,000 PXFP06000 PXEF12000 11W 340 x 520 20/25/32/40mm 12,000 PXFP08000 PXEF20000 18W 413 x 694 20/25/32/40mm 20,000 PXFP12000 PXEF30000 24W 413 x 694 20/25/32/40mm 30,000 PXFP15000 All UV filters have a rated voltage of 220-240V, 50Hz Introduction Congratulations on the purchase of your pondxpert filter. Once your filter is connected you can look forward to many years of healthy pond water. Your filter is pump fed so must be connected to a suitable pond pump in order to work correctly. Ideally a solids-handling pump will be used as this will push dirty waste and debris into the filter. PondXpert filters are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions and warnings in the manual may result in product damage and/or serious injury. Be sure to read and save this manual for future reference. General safety Instructions Read and observe all of the instructions before installing, connecting and operating. Make sure the filter is securely and correctly installed before switching on. Always disconnect the UV when not in use and when carrying out maintenance. Always disconnect all equipment in the pond before starting to handle, maintain, repair or install any pond equipment. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

For safety reasons, servicing or repair of this item should only be carried out by PondXpert. Never hang or carry the pump by the power cord. Do not operate the pump with a damaged cord or plug. The supply cord of the appliance cannot be replaced. If the electrical cord is damaged the product should be scrapped.. Safety and Electrical Connections This unit is designed for outdoor use only. It is weatherproof and should be situated safely pondside. The filter should be sited where it cannot fall into the water or become waterlogged. NO PART OF THIS UNIT SHOULD EVER BE SUBMERGED IN WATER. Direct exposure to UVC light can damage the eyes and skin. NEVER look directly at the UV when switched on. The translucent inlet will illuminate showing that the UV is working. Always disconnect all equipment in the pond before starting to handle, maintain, repair or install any pond equipment. The ultra violet clarifier housed within the filter is electrically operated so great care must be taken during installation and operation. The following electrical and safety guidelines must be carefully followed. Each filter is supplied with a length of 3 core electrical cable which is permanently connected to the ultra violet clarifier unit housed inside the filter. The wires in the mains electrical lead are coloured in accordance with the following code: BLUE Neutral (marked with an N in most terminal connections) BROWN LIVE (marked with an L in most terminal connections) GREEN/YELLOW EARTH (marked E or in most terminal connections) 1 st January 2005 revised Building Regulations for England and Wales Installing this product in the garden is classified as notifiable. The Regulations now require you to tell your local authority building control department that you intend to install this product before installation. Your local authority will let you know how you can get your installation approved The termination to the mains supply should be permanent, inside a dry weatherproof enclosure, through a double pole switched fused spur with a minimum contact gap of 3mm (disconnected) to BS 3676 and fitted with a 3 or 5 amp fuse. Exposed cable runs should be sensibly positioned, and protected if necessary by armoured conduit. A 10mA or 30mA Residual Current Circuit Breaker (RCD) MUST be fitted to the mains supply. Permanent installations to the mains supply (hard wiring) must comply with the regulations of the local electricity authority which may stipulate the use of metal or plastic conduit to protect the cable. If in any doubt about wiring to the mains supply contact a qualified electrician or your local electricity authority.

Protect from frost. In cold winter weather (when fish are inactive and algae growth ceases) the unit may be switched off. It should then be drained of water, removed (if possible) from its installation and stored in a dry, frost-protected area. The supply cable cannot be replaced. If the cable is damaged, the unit must be discarded. Directions for use Installation Once installed and connected to a suitable pump the pond water will flow through the filter. As this is a Pressure Filter the filter is sealed shut meaning the filtered water leaves the filter still under pressure. This means that you have maximum opportunity in positioning your filter as it can be buried up to it s hinged lid and below the water exit point. PondXpert filters are pump-fed, external filters with an integral UVC unit. Your filter is supplied with a black hosetail. This should be screwed into the threaded filter inlet. Pond hose size 20-40mm (3/4 to 11/2 ) can be attached to the inlet hosetail. Your pump and filter outlet should be positioned at opposite ends of the pond to promote maximum circulation. Cut the inlet hose to the size appropriate to the size of hose you are using. Then connect the hose from your pump to this inlet hosetail and secure with hose clips. The translucent hosetail should be connected to the filter outlet as described above. Maturation of the Filter Your filter comes complete with mechanical and biological filter media. The filter foam acts as a mechanical barrier to pick up solids whilst the bioball media housed at the bottom of the unit helps to develop friendly bacteria. These friendly nitrifying bacteria help to convert harmful fish waste and other organic waste (ie, ammonia, nitrite) into harmless nitrate. This biological maturation process usually takes 6-8 weeks. It is recommended that you do not switch on your UVC during this period. Maintenance As the filter does it s job the foam filters will block up reducing water flow. If the pond is very dirty then the foams may need cleaning every couple of days or so at first. Full Clean Cleaning Procedure: The filter requires minimum maintenance. If your pond is very dirty, initially you may need to clean the filter every couple of days. When the filtering process kicks in your water will become clearer and there will be less waste to remove. The red domed indicator turns completely red when pressure builds inside the filter suggesting that cleaning is necessary. Switch off any electrical connected to the pond (including the filter itself). Access to the filter can be gained simply by unlocking the securing clamping bracket around the rim (locking catches on smaller models). You can then simply lift the lid. Take the foam filters out of the unit and carefully wash away any solids using a bucket of POND WATER. Once clean replace the foams back in position. The bacterial chamber at the bottom of the unit should not be cleaned unless they are highly contaminated and should only be cleaned with pond water to preserve the microorganisms that keep your filter biologically active.

Quick Easy Clean Backflush Turn to the clean position, the water flow is reversed and exits through the waste outlet. This waste water should run to waste by attachment of a suitable length of hose. The movement of the cleaning handle from work to clean on PXPF04500 to PXPF12000 PXPF20000 to PXPF30000, triangle graphic on handle set to FILTER, to clean push handle down and turn handle round so triangle graphic is at CLEAN position Turn the handle back once the water from the filter runs clear (about 30 seconds). Note: if water water continues to leak from discharge pipe unscrew the plate on the underside of the lid and reposition the disc inside a smear of Vaseline may help the seal. If your filter is ever taken away from the pond (ie-winter storage) then all of the filter media (foams and biomedia) must be thoroughly cleaned before restarting. Your filter will then need to undergo the maturation procedure phase as described above. Note: Take care to ensure rubber O ring is correctly positioned between lid/unit after opening. Failure to do so will lead to leaks (a smear of Vaseline around this ring may help keep the seal watertight).

Filtration Spares and consumables The filter is supplied with everything you need to get started (including filter media, UV bulb and quartz tube for the UV). Over time these parts may need replacing and can be purchased from your retailer. Periods of operation Maintain filtration 24 hrs a day through the fish feeding season (typically early March- October when the water temperature is above 10 degrees C), but preferably all year round. In the winter operating the pump and filter will maintain a background level of friendly bacteria in the filter and help prevent the pond icing up in all but the severest weather conditions. Changing the UV Bulb The UV bulb should be changed at the beginning of every new season. The lamp may look like it is working but the levels of effective UV radiation decrease over time. First disconnect the unit from the electricity supply. At the time of writing access to the bulb in the PXPF04000 could be achieved internally. The larger units required the screws to be removed from the housing on the lid dome. If you are having problems please call 01642 370888 for advice. Remove the UV bulb by gently pulling out of the electrical connection. Insert a new UV bulb by gently pushing into the electrical connection then reassemble. PXPF20000/30 000 is easy to access and change but be careful when lifting out as bulb can displace easily Smaller models require removal of four screws from lid to access the twist cap UVC Limited Warranty This product is guaranteed for a period of 12 months from the date of purchase for material or manufacturing defects. The guarantee covers the substitution of defective parts. However, the guarantee is considered null and void in the case of improper use, improper handling or negligence on the part of the buyer. The UV bulb is not guaranteed. If your pondxpert filter fails please take it back to the retail outlet from where it was purchased. You will be required to provide your receipt/proof of purchase. This does not affect your statutory rights. PondXpert A3 Bentley Avenue Billingham TS23 4BU UK 01642 370888 www.pondxpert.co.uk Your appliance contains valuable materials which can be recovered or recycled. Leave it at a local civic waste collection point.