AIR COOLED MINI CHILLER

Similar documents
Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

INSTALLATION MANUAL AIR COOLED, DUCTED SPLIT TYPE AIR-CONDITIONERS SPLIT TYPE. Part No.:R IM-MHSB-0806-DAIKIN

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Air Conditioner Service Manual

CASSETTE TYPE AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

Trouble Shooting Guide FAA, 3-phase (D3631)

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

INSTALLATION MANUAL. Model UAT150CGXY1 UAT180CGXY1 UAT240CGXY1 UAT300CGXY1 UAT150CGXY19 UAT180CGXY19 UAT240CGXY19 UAT300CGXY19.

Part 3 Troubleshooting

Air Conditioner Service Manual

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Service Manual. Air Conditional

KSD-35 DR11 KUE-35 DVN11

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

INSTALLATION AND USER MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Service Manual. Air Conditional

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

INSTALLATION AND USER MANUAL

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Beverage Air IMPORTANT

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

15,000 BTU Portable Air Conditioner

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

PDF Created with deskpdf PDF Writer - Trial ::

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

INSTALLATION AND USER MANUAL

KM-630MAH KM-630MWH KM-630MRH

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

Operating Instructions Air Conditioner

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

AIR CONDITIONER ELECTRONIC CONTROL

WineZone Ceiling Mount Ductless Split 15

OPERATING INSTRUCTIONS

Bulletin (Jan 2011) And User s Guide

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

T-Series Air Conditioner T15 Model

NO. 24HE-632 ISSUED: JUL. 11, 2003 REVISED: AUG. 21, 2012 HOSHIZAKI CUBE ICE DISPENSER DIM-30AE DIM-30DE MODEL SERVICE MANUAL

KM-61BAH KM-101BAH KM-151BAH

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Horizontal/Side Discharge Condensing Units

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Air Cooled Module Water Chiller

Inverter Split-type Room Air Conditioner

USER S MANUAL HSC-14/18/24/24A

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

INSTALLATION & OPERATION MANUAL

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Product Features Technical Training 2007

NEXXOS INVERTER USER MANUAL

KML F SERIES KML H SERIES

SLIDER CASEMENT AIR CONDITIONER

Gallery Electric Fireplaces

User s Information and Installation Instructions

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

40KMC KMQ

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Display Cases Deli Cases Service Manual

INSTALLATION AND USER MANUAL

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

T-Series Air Conditioner T20 Model

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Condensing Unit Installation and Operating Instructions

Owner's Manual TABLE OF CONTENTS

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

KM-900MAF KM-900MWF KM-900MRF KM-900MRF3

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Outdoor and Indoor Electric Refrigerator Model COAR

Transcription:

INSTALLATION MANUAL AIR COOLED MINI CHILLER Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы.

INSTALLATION MANUAL This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirements. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. MODEL AIR COOLED MINI CHILLER Reference Model AC040A AC050A AC058A Models AMAC040A / MAC040A AMAC050A / MAC050A AMAC058A / MAC058A AC040AR AC050AR AC058AR AMAC040AR / MAC040AR AMAC050AR / MAC050AR AMAC058AR / MAC058AR AC075B AC100B AC125B AMAC075B / MAC075B AMAC100B / MAC100B AMAC125B / MAC125B AC075BR AC100BR AC125BR AMAC075BR / MAC075BR AMAC100BR / MAC100BR AMAC125BR / MAC125BR Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. Part No.:08019008612

CONTENTS - Safety Precautions page 2 - Outline And Dimensions page 3 - Unit Installation page 4 - Refrigerant Circuit page 6 - Water Filling page 6 - Electrical Wiring Connection page 6 - Chiller Control Operation Guide page 8 - Trouble Shooting page 9 SAFETY PRECAUTIONS Before installing the air conditioner unit, please read the following safety precautions carefully.! Warning Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance. All field wiring must be installed in accordance with the national wiring regulation. Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram. The unit must be GROUNDED to prevent possible hazards due to insulation failure. All electrical wiring must not touch the refrigerant piping, compressor or any moving parts of the fan motors. Confirm that the unit has been switched OFF before installing or servicing the unit. IMPORTANT DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.! Caution Please take note of the following important points when installing. Do not install the unit where leakage of flammable gas may occur. If gas leaks and accumulates around the unit, it may cause fire ignition. Ensure that the drainage piping is connected properly. If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture. Do not overcharge the unit. This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor. Ensure that the units panel is closed after service or installation. Unsecured panels will cause unit to operate noisily.

OUTLINE AND DIMENSIONS AC075/100/125 AC040/050/058

UNIT INSTALLATION

MODEL A B C AC040 058A AC040AR 058AR 950mm 900mm 900mm MODEL A B C AC075 125B 950mm 900mm 900mm

REFRIGERANT CIRCUIT All mini chiller series is precharged with refrigerant R22, the only pipe work that needs to be done is to connect the water piping between the mini chiller (outdoor unit) and the fan coil (indoor unit). Purging of the refrigerant R22 in AC040A/AR ~ 058A/AR series is only required if the unit is installed separately with hydraulic kit. WATER FILLING In this close water system, the pump can cater for longer piping compared to normal direct expansion units. After connecting all the pipes and equipments, filling water in the circuit, perform leak check for all the connections and joints. Do not start the unit when the system is leaking. To optimize the capacity of the system, ensure that the system is free of air bubbles or air-traps. Air traps in the system seriously unbalance the whole system. It is very important to check the whole water system especially ensuring that the water tank is not full of water. This protection step is not only to prevent tank & piping corrosion but also to ensure optimum performance of the unit. This can be done by releasing the air trap from the auto-air-vent (water tank) and manual air vent (installed in the highest place of the water system). ELECTRICAL WIRING CONNECTION MODEL AC040A/AR ~ AC058A/AR AC075B/BR AC100B/BR AC125BR Voltage Range 380 420V/3ph / 50Hz + Power Supply Cable Size 4 6 10 16 Number of conductor Interconnection Cable Size (mm 2 ) 2.5 2.5 2.5 2.5 IMPORTANT : These values are for information only. They should be checked and selected to comply with local and/or national codes of regulations. Which is also subject to the type of installation and size of conductors used. ;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;; Thermometer ;;;;;;;;;;;;;;;;;;;;;;;;;;; Expansion Tank ;;;;;;;;;;;;;;;;;;;;;;;;;;; Strainer Flexible Two Way Valve ;;;;;;;;;;;;;;;;;;;;;;;;;;; Three Way Valve Presure Differential Valve Thermometer Flexible Worst Controlling Good Controlling Bad Controlling Thermometer Flexible Two Way Valve Three Way Valve Presure Differential Valve Thermometer Flexible Worst Controlling Strainer Good Controlling Bad Controlling Water Feeding / Drainage

AC 040AR ~ 058AR Indoor Unit 12V DC or 230V AC Remote Switch or ON/OFF Switch Power Supply 415V/3ø/50Hz 1 2 N A comp Of 4WV AL1 AL2 COOL HEAT 12V 12V R S T N AC 040A ~ 058A AC 040A ~ 058A Indoor Unit Remote Switch or ON/OFF Switch 12V DC or 230V AC LED Power Supply 415V/3ø/50Hz 1 2 comp N AL1 AL2 12V 12V R S T N AC 075B ~ 125B AC 075B ~ 125B (EXPORT SPEC) Indoor Unit 12V DC or 230V AC Remote Switch or ON/OFF Switch Power Supply 415V/3ø/50Hz 1 2 N AL1 AL2 C.OL FS P.OL LP HP HEAT COOL 12V 12V R S T N AC 075BR ~ 125BR AC 075BR ~ 125BR (EXPORT SPEC) Indoor Unit 12V DC or 230V AC Remote Switch or ON/OFF Switch Power Supply 415V/3ø/50Hz 1 2 N AL1 AL2 C.OL FS P.OL LP HP HEAT COOL 12V 12V R S T N

CHILLER CONTROL OPERATION GUIDE 1. ON/OFF Toggle switch Push up to start the chiller. Push down to switch off the chiller for servicing and maintenance. 2. Water Entering Temperature C (Factory Setting) Cooling Mode, setting : 12 C Heating Mode, setting : 40 C 3. Antifreeze Protection for Cooling Mode Setting : 2 C 4. Temperature Setting For cooling mode, press the SW1 button switch once. The green LED will blink for a few seconds. Adjust the small variable resitor (VR3) to the required water entering temperature of between (10 C - 15 C) by using a suitable tool. For extremely low water temperature (obtained by adding glycol), set the water entering temperature to between 3 C to 9 C by adjusting the DIP switch (SW2). S1 COMP AHTR OF PUMP S 2 S 3 + 12V 4WV AL 1 AL 2 + 12V L RL 1 RL 2 RL 3 COOL HEAT L SW 2 RL 6 RL 5 RL 7 PCB RL 4 RL 8 HP LP S 4 PUMP O/L FL COMP O/L OV S6 NEUTRAL TH1 TH2 TH3 TH4 S5 VR 2 VR 3 VR 1 SW 1 OUTDOOR DEFROST SENSOR SOCKET. (LENGTH 1.0M) OUTDOOR AIR TEMP. SENSOR. (LENGTH 0.6M) LEAVING WATER / ANTIFREEZE SENSOR. (LENGTH 1.0M) ENTERING WATER SENSOR. (LENGTH 0.6M) If the DIP switch is set to (0,0,0), the setting temperature will be determined by the VR3 setting. Otherwise, For heating mode, press the SW1 button switch twice and then the red LED will blink for a few seconds. Adjust the variable resistor (VR1) by setting it to the required water entering temperature which (35 C ~ 50 C) for heating mode. To prevent water from freezing in the system, adjust the variable resistor VR2. The setting range is between +3 C to -4 C. Set SW2 Temperature C SW 2-3 SW2-2 SW2-1 Set by VR3 0 0 0 3 0 0 1 4 0 1 0 5 0 1 1 6 1 0 0 7 1 0 1 8 1 1 0 9 1 1 1 Все каталоги и инструкции здесь: 1 = ON http://splitoff.ru/tehn-doc.html 0 = OFF

TROUBLE SHOOTING If any malfunction occurrs, immediately switch off the power supply to the unit, and contact a local dealer if necessary. Some simple trouble shooting tips are given below. SYMTOMS POSSIBLE CAUSES REMEDIAL ACTION 1. Compressor does not start. 2. Fan does not work. 3. Air cooled mini chiller does work, but cools unsuffuciently. 4. PCB display CO. 5. PCB display PO. 6. PCB display FL. * No power supply. * Fuses blown or automatic circuit breakdown open. * Thermal relay tripped. * Defective contactor or coil. * Unit is stopped because safety device has tripped. * Loose wires. * Compressor faulty. * No power supply. * Fan motor faulty. * Thermostat setting too high. * Condenser coil dirty. * Obstacle blocking air inlet or outlet of the unit. * Insufficient refrigerant in the system. * Improper water flow rate. * Water source contains contamination. * Compressor thermal relay tripped. * Terminal loose. * Pump thermal relay tripped. * Terminal loose. * Flow switch connection loose. * Wrong terminal in flow switch. * Water volume not enough. * Flow switch blade too short or too long. * Check power supply. * Look for short circuit or grounded wires in motor windings. Replace fuses and reset circuit breakers when the fault has been corrected. Check tightness and soundness of all electrical connections. * Reset the thermal relay and carefully monitor units operation when it is restarted. * Repair or replace. * Determine the type of safety shut down and correct the default before the unit is restarted. * Check wire connections and tighten terminal screws. * Check power supply. * Reset thermostat. * Remove the obstacle. * Reset the thermal relay and carefully monitor units operation when it is restarted. * Tighten terminal screws. * Reset the thermal relay and carefully monitor units operation when it is restarted. * Tighten terminal screws. * Tighten terminal screws. * Change the terminal. * Add water into the system. * Replace flow switch. 7. PCB, display HP. 8. PCB display LP. * Discharged pressure too high * Reset the pressure switch and observe the units operation when it is restarted. * Overcharge. * Coil dirty. * Clean the coil with chemical detergent. * Condenser Fan does not work * Expansion valve stuck in open position * Replace it. * Suction pressure too low * Undercharge * Gas Leak * Water flow rate too low * Reset the pressure switch and observe the units operation when it is restarted. * Adjust the flow rate. 9. PCB display E3. * Antifreeze protection activated. * Water flow rate too low * Bubble in the heat exchanger * Check the temperature setting. * Adjust the flow rate. * Increase the water volume.

OYL MANUFACTURING COMPANY SDN. BHD. JALAN PENGAPIT 15/19, P.O. BOX 7072, 40702 SHAH ALAM, SELANGOR DARUL EHSAN, MALAYSIA. CK20AN-Cover 2 20/07/2000, 14:49 Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы.