SDAV VIA DETECTORS FOR HIGH-SPEED LINES

Similar documents
Praetorian Fibre Optic Sensing

Praetorian Fibre Optic Sensing

Praetorian Fibre Optic Sensing

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

CLOSURE OF INTERFACES FOR RAILWAY LINE HERZELYA KEFAR SABA IN CLOSURE_INTERFACES_HZL-01

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

Pipeline Integrity Monitoring with DAS

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

OH110, OP110, HI110 Automatic fire detectors

WG Buried Fibre Cable Long Perimeter Detection System

RLS-3060SH REDSCAN ULTIMATE

IR15 Dual Gas Series Datasheet

Section PERIMETER SECURITY SYSTEMS

IR25 Dual Gas Series Datasheet

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

DS-2TD Thermal & Optical Network Bullet Camera

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

FUNCTIONAL SAFETY MANUAL

ALTAIR 5X Multigas Detector Product Specification

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Lamp Supply (Recommended)

The evolution of level switches and detectors

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Transport research opportunities and needs: What can fibre optics do for us? Stephen James Engineering Photonics

DESCRIPTION AND SPECIFICATION

Security designed for your lifestyle

Sentry G3 Machinery Protection Monitor

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

DATA CENTER SECURITY. March 2017 Anton Panaitescu

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

FDOOT221, FDO221, FDT221

A New Standard of Excellence

Product Specification

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Professional perimeter intrusion detection system

PMD2 Plus/EZHD. Elliptic, Multi-Zone and Heavy Duty

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

More Precision. indusensor // Linear inductive displacement sensors

Symphony Plus Combustion instruments

02/11/2015

FTS510 Series. Handheld OTDR Test Set.

02/11/2015

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

XSD Dry Cabinet

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Committed to security

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Fiber Optic Pipeline Monitoring System Preventing and detecting leaks in real time

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Advanced DIGITAL Wired PIR Motion Detector

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

FTS500 Series. Handheld OTDR Test Set.

XSD Dry Cabinet

DCS DSS OSS EIB OBPS OPTS FDS AFSS

Open-area Smoke Imaging Detection (OSID)

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

OTP6123 Series. Handheld OTDR Test Set.

Dräger Flame 2500 Flame Detection

>WIRELESS> ALARM SYSTEM CR200

FUNCTIONAL SAFETY MANUAL

Dräger Flame 2100 Flame Detection

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

XSD Dry Cabinet

RLS-3060SH REDSCAN ULTIMATE

Chapter 1. Introduction

Open-area Smoke Imaging Detection (OSID)

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

F1 Smart Home Security Sensors. Unlocking the Potential of Your Wireless World

User s Manual for ZKIR3 Series IR Day & Night

Datasheet: K-22 LO Sensor

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

HDCVI PIR Camera User s Manual

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Corporate Presentation

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Sentry G3 Machinery Protection Monitor

RailAcoustic Ò Broken Rail Sensing System

General Specifications

Intelligent addressable fire alarm control panel

WG Railway Security Protection System

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Product Tests Report

Transcription:

SDAV VIA DETECTORS FOR HIGH-SPEED LINES Falling Object Detector to track (DCO) Lateral Wind Detector (DVL) Dynamic Behavior Detector Pantograph (DCP) Detector gauge excess in the circulation (DEG) Catenary breakage detector (DRC) FTC_541000005_01

FALL DETECTOR OF OBJECTS TO VIA (DCO) Its mission is the retention and safe detection of objects falling overpasses and road tunnel mouths and communicate simultaneously to the Command Post and the devices, electronic interlocking ENCE, the information in the non-presence of objects falling to way. Detection of objects in impact to 200Kg. Certification SIL4 sensory element detects falling to inform the ENCE for voltage free contacts. Certification Ethernet communications SIL2 ENCE. The main features built into this device are: There is no electronic way. Minimum maintenance. High availability without incident on the farm. Immune to operating conditions. Remote control detector Communications: Ethernet and IEC 600870-5-104 proprietary protocol ADIF profile. ENCE Communications: Ethernet dual SIL2, EN 50159-1. Range based on the number of steps to 40Km. Predictive maintenance analysis system automatically detected the degradation of sensory element. Electrical and environmental interior equipment: o Consumption for 12 steps: <200W. o Operating temperature: 0 to 60 º C indoor team. o EMC: 50121-4:2007, EN 61000-2-4, EN 60870-2. Double Fiber optic illuminated bidirectionally coded identification code and address and pass.

SIDE WIND DETECTOR (DVL) Its mission is to inform the Control Centre and the interlocking of the prediction of wind speed and direction at different points of travel in order to limit the speed of circulation, relying meteorological parameters of wind speed and direction, relative humidity, temperature and atmospheric pressure and calculation of the predictive algorithm. Its main features are: Recording in real time. Storage of history. Download DB and application. 10 minutal prediction algorithm certified by ADIF and SENER. Available in high-availability version control systems and procedures and redundant communications. Simultaneous, Remote detectors, with ENCE proprietary protocol Ethernet, dual Ethernet. Power supply: 240 Vac., Consumption: <60W Operating temperature: -20 to 70 C. EMC: 50121-4:2007, EN 61000-2-4, EN 60870-2-1 3 in anemometers. Measuring range 0 to 360 º and speed resolution 1 º 0 to 60m / s resolution 0.5 m / s. Mount 2oo3. Thermo-hydrograph. Measuring range 0 to 100% RH and ± 2%. Barometer. Measuring range 600 to 1600hPa with a resolution of 1 hpa... Developed to specifications SIL 2. Terminal maintenance discharge capacity and historical analysis, calibration and system configuration, as well as the representation of sensor data, wind algorithm output, and equipment condition. GENERAL MAP EXPANSION AREA

DETECTOR DYNAMIC BEHAVIOR OF PANTOGRAPH (DCDP) Its mission is to measure physical parameters of the trains in the high-speed (speed, direction). Assistance in the detection of irregularities in the pantograph-catenary interaction (poorly calibrated pressure pantographs, Microfusione in pantographs). Saving historic passage of trains along with their characteristics. Measurement of meteorological parameters. The functions built into this device are: Make auscultation per-view (no contact with the overhead) of the elongation of the overhead contact line caused by the pantograph trains in either direction of movement.. o Maximum speed: 350 km / h o Maximum Elevation: +150 mm,-100mm. o Resolution: 1.2 mm with an accuracy of 1% o Minimum interval between trains or: 55 seconds (safety margin). Alarm detection performance (multiple alarms maximum displacement of the wire (value configurable), alarm operating pedal shaft sensor alarm, alarm, camera, alarm and alarm screen for communicating with the remote). Configurable system with all parameters for the installation environment.. Auto Calibration (Lighting and contact wire position). Immune to vibration of the poles and changes in the contact wire height for environmental effects. The system does not interfere with the operation of the signaling equipment or with equipment loaded onto the trains running Ethernet Communications proprietary protocol. Power supply: 240 Vac. Consumption: <400W. Operating temperature: satellite equipment: -10 to 60 C. Equipment inside: 0 to 60 C

EXCESS OF GAUGE DETECTOR Its mission is to detect any object that exceeds the allowed gauge regardless of flow direction. Non-intrusive to the existing infrastructure. Is designed to be adaptable to the detection of any gauge. Immune to operating conditions. IR laser detection sensors. Storage of history. Characteristics: o Maximum train speed 165 km / h. o Minimum speed 18 km / h.. o Object minimum or maximum speed 20 cm. The accuracy of the measurement is less than ± 1 cm. o Minimum time between trains or 12 sec. o Maximum reaction time of the detectors 300 msec. Communications: o Remote control detectors: Ethernet proprietary protocol. Electrical and environmental interior equipment: o Power: 240 Vac. o Consumption: <100W. o Operating temperature: 0 to 60 C. Electrical and environmental team via: o Power: 240 Vac. o Consumption: <40W. o Temperature: -20 to 70 C. Sensors: o IR or laser technology. o Temperature: -20 to 70 C. o IP 67.

CATENARY BREAK DETECTOR Its main functions are: - The detection of rupture of the overhead contact line. - The compensation control by Detecting the locking of pulleys. The Risk of not Detecting a broken overhead inside a very long tunnel for the circulation Which enter the tunnel is broken With The LAC is a catastrophic Because it very important cause, to effect a fire inside the tunnel. The functions built into this device are: Duality of sensors. Duality of communications equipment inside. Storage of history. Communications dual different physical media (twisted pair and power line) with the integrity level sufficient to meet the EN 50159-1 (secure communications systems in closed environments) Duality of sensor elongation. Alternative road hub. Temperature measurement for predictive maintenance. distributed power supply system of low and high protection. Diagnostic equipment continued The system adapts to small very long tunnels Remote control detector Communications: Ethernet IEC 600870-5-104 ADIF profile. Specifications: o Measurement accuracy: ± 1 mm o Range elongation or the extent of compensation: ± 1000 mm. o Measure of the rate of fall of compensation up to: ± 5m / s. o Power: 240 Vac. o consumption: <150W. o Temperature: -20 to 70 C.

REFERENCES DETECTORS DETECTOR FALLING OBJECTS (DCO) LAV Madrid Lleida. LAV Madrid Levante. LAV Barcelona Figueras. LAV Medina del Campo Olmedo LAV Figueras - Perpiñán SIDE WIND DETECTOR (DVL) LAV Madrid Levante. Drag object DETECTOR (DOA) LAV Figueras - Perpiñán DYNAMIC BEHAVIOR DETECTOR ROUTER (DCDP) LAV Madrid Lleida. LAV Figueras Perpiñán LAV Madrid Levante. LAV Madrid - Valladolid EXCESS OF GAUGE DETECTOR (DEG) LAV Figueras - Perpiñán CATENARY BREAK DETECTOR (DRC) LAV Madrid - Valladolid