for Anita Bonding Consoles

Similar documents
LIST OF CHAPTERS 1 ANITA BONDING CONSOLE SERIES HEATING BLANKETS & OTHER HEATING SYSTEMS... 19

LIST OF CHAPTERS 1 ANITA BONDING CONSOLE SERIES HEATING BLANKETS & OTHER HEATING SYSTEMS... 17

LIST OF CHAPTERS 1 ANITA BONDING CONSOLE SERIES HEATING BLANKETS & OTHER HEATING SYSTEMS... 17

INFRARED HEATERS APPLICATIONS INFRARED HEATING

Model 4150 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

Infrared heater - Item Description. Print

Exhaust Air Plenum Heated Supply Air. Direct Impingement Convection Dryer. Heated Drum. Typical Conduction Heating System.

Model 5306 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

ACCELERATE YOUR CURING TIME

Infrared Heaters For Controlled Concentrated Curing

Technical Description

Short Wave Infra-red Car Paint Curing Equipment. User Manual. Model: IR1 IR1+S3 ( ) ( )

KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY)

We offer ceramic radiant heaters and infra-red radiant tubes.

Ceramic/Quartz Infrared Emitters

CURE ZONE 2 (#A )

Shortwave Infrared Paint Curing Lamp SPEED DRY 300AX

Radiant Heaters. Radiant Heaters

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

SHORT WAVE INFRARED PANEL DRYER

Radiant Process Heaters

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

TX1 ArcMesh transmitter

Welcome: AEP Customers and Employees

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Condensing Units CUS 15-60

140 FT. LONG HOT AIR OVEN FOR SOLVENT COATINGS

PRODUCT DATA SHEET. Models 5208, 5090, & Repeatable results can be achieved for consistent process outputs

Programat P510. Efficient firing performance. Excellent results. With infrared camera. The intelligent furnace

Section 16. Infrared & Fan Heaters

We call it Comfort Heating

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

DOUTHITT HEAVY DUTY PLATEMAKER

Operation Manual For Sodir. ½ Size Convection Oven FC-60, FC-60G

EMITTER TECHNICAL DATA

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

INSTALLATION AND OPERATION MANUAL PORTABLE INFRARED HEATER. of REM/RET type

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

Radiographic processing. Processing equipment

Instruction Manual E4 ChamberIR Heater

Molex Premise Networks Corporate Headquarters Harvard, MA Tel: Tel: Fax:

CURE ZONE (#A )

SD Storage Cabinet. Outstanding performance

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Infrared Heaters Fast Response Medium Wavelength Infrared Panel Heaters Features: Configurations:

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

YDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

3 Heating Effect of Electric Current

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Radiant Process Heaters

Figure 1-1 Furnace Front Elevation

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Light Spectrum. Wavelength (in microns)

User Manual. Model: FSL100 Laser Fume Extractor

AMBIRAD.... Vision Radiant Tube Heating Systems...

Model: Ceiling Cassette V 9k-24k

RHINO HEATING, COOLING & DRYING SOLUTIONS

Flat Panel Emitter Replacement Element Guide For CH, MR and FHK Series

Plant Growth Room MBDW Walk In Room

Infrared Electric Heaters - General Product Information

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Handheld Training Manual

USER AND MANUAL BOOK

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Toll Free:

Ozone Generator Air Purifier HE-500/O3

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

Advancement In Coating Curing On Railcars

Caution: The fans must not be used in bath or shower enclosures.

Manufactured....installed worldwide

INTERNATIONAL STANDARD

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

OPERATING AND MAINTENANCE MANUAL

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Pure comfort & design

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Pure comfort & design

Extinguishers. Commercial Industrial High rise buildings

PMFY-P20VBM-E. City Multi Indoor Product Information. Indoor Unit

UNDER-COUNTER WINE COOLER

DEVIL CERAMIC SPACE HEATERS

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

SECTION DOMESTIC WATER HEATERS

AUTOMOTIVE MANUFACTURING CURING EQUIPMENT

PAINT LINES IRT-BOOSTER

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification

Section N. Application Information. Thermal Manufacturing Solutions. Extrusion N-1. Injection Moulding N-2 N-3. Other N-4

Transcription:

Innovation in Technology for Aircraft Maintenance and Fabrication Equipment, Solution Engineering, Research, Training RADIANT SYSTEMS for Anita Bonding Consoles P/N: GMIWRP-MKD011 Revised July 2012 GMI AERO - 9 rue Buffault 75009 Paris Tel : +33142821144 - Fax : +33142829838 Email : gmi@gmi-aero.com - Web : www.gmi-aero.com

RADIANT SYSTEMS for Anita Bonding Consoles, GMI AERO offers a selection of RADIANT equipment to meet a certain variety of use in a composite repair workshop. curing composite repair patch with epoxy resin drying resin, polymerization of paint, primer 1 CERAMIC RADIANT PANEL HEATER When a heating blanket cannot be used for bonding a composite repair, radiant panels constitute a very useful alternative. GMI designs very high quality radiant panels perfectly appropriate to composite repair bonding. This family identified as RAYBOND is designed to produce an even temperature distribution on the part. To allow an easy installation adjustable legs are mounted on each side; the leg position can be adapted so that two panels can be installed side by side to constitute a continuous heating panel.they can be adjusted in height. These panels are designed in terms of power to allow classical curings up to 120/180 C on a composite part Each panel is equipped with an input power stud; a cable is mounted (3 meters long) with a plug compatible to be connected to ANITA Bonding Console. Each panel has 4 adjustable legs; maximum adjustable height: 120 mm. Electrical Connection lead to the Anita for control Legs adjustable in position and height Table 1 :P/N and Definitions Dimensions P/N 30 x 30 cm GMIRP030030-1Z-V 40 x 40 cm GMIRP040040-1Z-V 50 x 50 cm GMIRP050050-1Z-V 60 x 60 cm GMIRP060060-1Z-V 2

2 INFRARED LAMP PANELS MOUNTED ON ARTICULATED ARM ASSEMBLY 2-1STANDARD MODELS This second family of radiant panels regroups models mounted on articulated arms to ease the positioning above complex and large parts. They are mainly used for paint, primers and small area curing of epoxies at low temperature (typically 120 C/250 F). They are proposed mounted on an articulated arm, itself on a rolling assembly. 2-2MODEL STANDARD FOR LARGE SURFACE Its design features provide a large surface coverage with good temperature distribution a. One cassette with 3 infra-red emitters b. high life duration of emitters due to permanent ventilation c. ventilation provides high security for the user d. 10000 hours life duration of emitters e. The panel can be controlled by Anita Bonding Console through direct connection like a heating blanket Figure 1: Articulated Model standard P/N:GMIWRP-MKD011-July 12 3

Connection for Anita Console control cable Figure 2 : Selection Switch and Modes: Left: Timer Mode; Right: Anita Control On the right we see the connection to the bonding console - see also pictures below 2-3TECHNICAL SPECIFICATIONS 1. Rated voltage: 220V - 240 V, 50/60 Hz Single Phase 2. Rated input (Nominal): 3 emitters, full power 3000 W 3. Heating elements: 3 quartz, tungsten filament, Infra Red emitters 4. Area of coverage: 1 m x 0.90 m larger surface for drying temperature (black sheet metal as reference) 5. Dimensions nominal: WxDxH: 95 x 164 x 150 cm 6. Weight: 46 kg 7. Noise level Less than 70 db 8. Max ambient temperature during operation 40 C 9. Max ambient temperature during storage and transportation 70 C 10.Manual mode with timer 4

2-4 xcontrol BY ANITA CONSOLE Figure 3: The infra red heating system is controlled by the Anita like a heating blanket thanks to our adapted interface All our panels are wired to be able to connect to our portable control unit (Anita Bonding Consoles). Our bonding control console will «see the system as an Infra Red Heater. Power connections P/N:GMIWRP-MKD011-July 12 5

are specifically designed. Power is fed to the heaters through a cable to connect safely (see picture below). A selection switch allows to select between Manual Mode with a Timer or Automatic with Anita Bonding Console control. FUSE Figure 4: Connection of the control cable from Anita Console 2-5TO ORDER The radiant system complete P/N: GMIWRP-01M-2 (230 Volts) 2-5.1 SPARES One tube for a cassette as replacement: To order: P/N: GMIWRP-01M-ST-01 (230 Volts) Filter To order: P/N: GMIWRP-01M-F-01 6