ZERO CLEARANCE Z-SYSTEM

Similar documents
ZERO CLEARANCE Z-SYSTEM

ZERO CLEARANCE BOX INSTALLATION INSTRUCTIONS

XANDER INSERT WOOD BURNER

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

WOOD HEATING COLLECTION

Cleaner & More Efficient Heating Than Ever Before

OWNER S MANUAL FOR ALL

Caliente. Tested and approved to Australian Standards AS/NZS 2918:2001 and AS/NZS 4013/4012:2014.

Quality Through Integrity

Classic Pricotech proudly supports the activities of Landcare Australia through its membership of the AHHA.

Quality Through Integrity

The Discovery Series Exploring The Australian Indoors. Woodheating

Specification and Installation Instructions

Specification and Installation Instructions

The Discovery Series Exploring The Australian Indoors. Woodheating

Woodheating. Paramount. Woodheater Range. Hamersley Pedestal. The warmest welcome to the great indoors

the flame of the future

Manor maxiheat. Owners Manual For. Wood Heater

A wood heater that s right for every home! THE FLAME OF THE FUTURE

Inset - IB850, IB1100 Fascia Installation Manual NEW ZEALAND EDITION

Kimberley Mk3 Insert. Operation & Installation Instructions. Heating A division of A.F. Gason Pty. Ltd. Troubleshooting (continued)

^ STUV 21: MODEL SPECIFICATIONS

Installation and Operating Instructions for the following Woodsman models

Bringing home the warmth of wood heating Collection

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

INTERNATIONAL GAS CONVECTOR BOX

Flueing Installation Manual

gas & wood fire collection

Model: WS18-AU. Model: WS22-AU

TRUST ONLY GENUINE COONARA WOODHEATERS

IB1100 and IB850 Installation Manual AUSTRALIAN EDITION

Specifications, Installation and Operating Instructions for Woodsman Solid Fuel Burners

P P Gas Fireplace. P See Thru

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

H1200/DS H1400 H1600/DS H1600XXL/DS H1200VLG/D H12003V epi950

Product Catalogue 10YEAR. Fitzroy Profile and Canterbury Classic Series 2015 WAR RAN T Y YEAR

Eco-Choice Insert Wood Burner Installation Instructions. Model: WINS18-AU

LANDSCAPE BALANCED FLUE SPACE HEATER

LANDSCAPE BALANCED FLUE SPACE HEATER

INSTALLATION & OPERATING MANUAL

Studio 2. Balanced Flue with Thermostatic Remote Control. Installation Instructions. For use in AU (Australia). IMPORTANT

Europa 7 Europa 7 VL Multivision 8000 Series Super 9 Visio 8 Plus

TRUST ONLY GENUINE COONARA WOODHEATERS

IB850 and IB600 Installation Manual AUSTRALIAN EDITION

INSTALLATION & OPERATING INSTRUCTIONS

Woodheating. The warmest welcome to the great indoors

INSTALLATION & OPERATING MANUAL

Wok Cookers Instruction Manual

WITH OMRON E5CC CONTROL

Riva Studio. Inset Convector Cassette MODELS: RVS-1/RVS-2/RVS-3. Instructions for Use, Installation and Servicing For use in New Zealand (NZ).

GREENFIRE GAS FIREPLACES

Food Premises - Structural Specifications

Installation & Operation Manual Fascia / Firebox / Build-In Cabinet

gas log fires freestanding & inbuilts

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

CONTENTS OF LOOSE PARTS BAG (Note: You may not need all these parts for your installation)

Heating Accessory Range. ECO flue systems Floor protectors Child guards Climate control General accessories

Australian/New Zealand Standard

Installation Manual EF5000 AUS & NZ

THE CHOICE IS CLEAR. Quality Australian Made Wood Heaters

Scandia Avante Open Fire

THE INSTALLATION AND OPERATING INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT TALISMAN WOODFIRES

GREENFIRE GAS FIREPLACES

----FIREPLACES---- Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces. 24/10/2017 Ver. 15

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

Flueing Installation Manual For Rinnai Flamefire Heaters

The Difference Is Quality

INSTALLATION MANUAL Power Flued Flamefire Space Heater Co-axial Flue System

Model: WS18-AU. Model: WS22-AU

REHR6* WRH605I* WRH608I* WRR614*A WRH908I* Retractable Rangehood User manual

Installation Manual EF5000 NZ

600 SERIES INSTALLATION & OPERATING INSTRUCTIONS

COOKING. Microwave Trim Kit MWTK1S MWTK2W MWTK3B MWTK4S. Instructions for Use Installation and Warranty Details

USER S GUIDE FOR PASTA COOKER SERIALS

PTO50 Outdoor Decorative Fireplace

SPECIALIST GAS LOG HEATER RANGE

CALISTO. Owners Manual For All. Wood Heaters. Freestanding and Insert models Small, Medium and Large sizes

KEMLAN CELESTIAL 900 INSTALLATION & OPERATING INSTRUCTIONS

Trinity Mk II WOODBURNING STOVE

gas log fires freestanding & inbuilts

The. Classic. Collection. Cast-iron fireplace packages for your home

The Victorian High Country Home of Euro Fireplaces

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Southern Series. Free-Standing Wood Burner

ERCE9025BK ERCE9025BA

SHAMIC SHEETMETAL (AUST.) PTY. LTD.

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

St. Croix Greenfield Installation Manual

argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9

VC10LPH with HEPA Filter & Disposable Dust Bag

Flue Installation Manual

Evolve 951 & Product specification pages

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Nectre N60. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

IGE850 ISLAND GOURMET ELITE CUT OUT SPECIFICATIONS

ABOUT EURO FIREPLACES

ERR627SA ERR927SA. Rangehood Installation manual

Transcription:

Innovation. Performance. Efficiency. ZERO CLEARANCE Z-SYSTEM INSTALLATION INSTRUCTIONS Standard, Edwardian & Victorian Models Large & Medium Sizes Please read and save these instructions in a safe place for future reference. Serial No: Model: Colour: Date Installed: Park- Tec Engineering Pty Ltd ABN: 23 001 387 382 Building A2, Campus Business Park, 350-374 Parramatta Road, Homebush NSW 2140 Made in China. Imported by GLG Australia.

Important Safety Information WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING TESTED TO AS/NZS 4013. ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013. CAUTION: MIXING OF APPLIANCE OR FLU-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE. CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS S OR CERAMIC TILES, MAY RENDER THE INSTALLATION UNSAFE. Exclusion of Liability Whilst every care has been taken in formulating these instructions, no responsibility whatsoever will attach to and/or claim lie against, the manufacturer and/or the distributor of the heater as a result of any failure to follow the whole or any part of the instructions and/or as a result of incorrect information herein and/or any omission here from. Clean Air Woodheating P/L Page 1

Step 1 Refer to clearances as specified throughout these instructions and select position for your heater. Allow for clearances in roof for flue system. Ensure heater is clear of any combustible materials. EXAMPLES OF TYPICAL INSTALLATIONS Air vents as shown must be used. The vents at the bottom need to be a minimum of,000mm² (equivalent of a cm x cm opening). This allows the air to flow through the enclosure. See Step 4 for further details. AIR VENTS AIR VENTS HEATER 30 mm REAR CLEARANCE 30 mm REAR CLEARANCE AIR VENTS 30 mm CORNER CLEARANCE AIR VENTS Clean Air Woodheating P/L Page 2

Step 2 Put your heater into position: a) For Concrete Slab Only: Use spacers underneath heater to achieve required hearth height. For Combustible Floors Only (such as timber floors): If there is to be any combustible floor covering material (such as carpet) under the heater s final position, it is recommended that it is removed before placing the sub frame and heater into position. Place the sub frame on floor. Place the heater on top of sub frame. The sub frame is provided with the heater. It consists of 12 mm fibre cement sheet, 25 mm steel tube, with 6 mm spacers. SUB FRAME TIMBER FLOOR DIAGRAM NOT TO SCALE b) A hearth will need to be installed in front of the heater. Use 12mm thick cement sheet. Refer to the table below for the hearth dimensions. MEDIUM LARGE WIDTH (mm) DEPTH (mm) 950 50 When the heater is in position, remove the front fascia. Clean Air Woodheating P/L Page 3

Step 3 Fix triple case flue to heater. Screw the bottom flue heat shield to the flue outer casing - allow 25 mm clearance. Install through roof to manufacturers specifications to comply with AS/NZS 2918. The heater must be installed by a certified installer. We recommend you use a Maxiheat Zero Clearance Flue Kit. INSTALLATION TO AS/NZS 2918:2001 IMUM HEIGHT OF THE FLUE SYSTEM FURTHER THAN 3 m FROM THE HIGHEST POINT OF THE ROOF SHALL BE 1 m ABOVE ROOF PENETRATION FLASHING IMUM 1 m SEAL BOXED AREA WITH CEMENT SHEET FROM EXTERNAL DRAUGHTS & VER TRIPLE CASE FLUE ONLY 25 mm IMUM CLEARANCE TO TIMBER EXISTING WALL LINING (eg. PLASTER) FLUE BRICKWORK EXISTING WALL LINING (eg. PLASTER) HEAT SHIELD TO MANTLE SHELF (see details in Step 6) BOTTOM HEAT SHIELD FOR TRIPLE CASE FLUE (details on page ) (use non-combustible sheeting) STAINLESS STEEL INNER FLUE MUST BE FIXED TO THE HEATER HEATER HEATER IMUM 30 mm FROM COMBUSTIBLE MATERIALS AT REAR HEARTH SUB FRAME Clean Air Woodheating P/L Page 4

Step 4 Locate the timber frame around the heater cabinet. Dimensions below are to the first timber studs in the frame. CAVITY FOR HEATER 1200 (from base of heater) 0 (from heat shield to first internal timber stud) 955 (MEDIUM) 55 (LARGE) You will also need to adhere to the clearance dimensions below. MEDIUM LARGE A 545 595 B 515 565 C 265 315 AIR VENT 200 x 0 mm BOTH SIDES All dimensions are in millimetres. 30 mm IMUM FROM COMBUSTIBLE MATERIALS VENTILATION TO ENCLOSURE FOR AIR FLOW AND IMUM HEAT RETURN 3 A B B & C are heater dimensions C 115 BOTTOM HEAT SHIELD Allow 25 mm clearance between heat shield and flue outer casing AIR VENT Note: 1. The boxed area for the heater must be sealed from external draughts and vermin. 2. The frame must extend to the ceiling. 3. All dimensions and clearances are IMUM and must not be reduced under any circumstances. Clean Air Woodheating P/L Page 5

Step 5 We recommend the heater frame be covered with non-combustible sheeting. A floating isolator panel also needs to be installed. The floating isolator panel sandwiches between the front of the heater and the heater fascia as per diagram below. This panel MUST use noncombustible sheeting. Do not fix the panel. NON-COMBUSTIBLE SHEETING (RECOMMENDED) FRAME FLUE EXISTING WALL LINING FRONT FASCIA HEATER CABINET SUB FRAME DIMENSIONS All dimensions are in millimetres 955 MED 55 LGE 1200 700 MED 750 LGE 720 MED 820 LGE Re-install front fascia over the floating isolator panel. If installing with a mantlepiece: the floating isolator panel edge will be covered by the mantlepiece. If installing without a mantlepiece: a floating isolator panel is still required. Use a trim to finish off the panel edges so that it remains floating. Paint surrounding area and tile hearth with desired tiles. Note: Minor hairline cracks on the floating isolator panel may be noticed with time. These are not a problem and can be repainted after sheet settles. Clean Air Woodheating P/L Page 6

Step 6 : Installation with Mantlepiece Fit the mantlepiece and complete the area. Please refer to following pages for mantlepiece installation clearances. MANTLEPIECE INSTALLATION CLEARANCES STANDARD ZERO CLEARANCE WOODHEATER MEDIUM STANDARD 250 180 1 Min. 70 mm wide x 330 75 595 25 960 25 LARGE STANDARD 250 180 1 Min. 70 mm wide x 330 75 645 25 60 25 NOTE: 1. All dimensions are in millimetres. 2. Clearances are to combustible materials and are a minimum. 3. The minimum distance between the hot air outlet and the underside of the mantle shelf is 330 mm. For distances over 600 mm, no heatshield is required. 4. The heatshields, as specified above, must be used to maintain clearances. Ensure heatshields extend the width and depth of underside of mantle shelf and key. 5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards when installed to enclosed dimensions. Test Reports: MED HCMG/04/025 & LGE HCMG/04/026 Clean Air Woodheating P/L Page 7

MANTLEPIECE INSTALLATION CLEARANCES EDWARDIAN ZERO CLEARANCE WOODHEATER MEDIUM EDWARDIAN 250 180 1 Min. 70 mm wide x 330 75 595 60 800 60 LARGE EDWARDIAN 250 180 1 Min. 70 mm wide x 330 75 645 60 900 60 NOTE: 1. All dimensions are in millimetres. 2. Clearances are to combustible materials and are a minimum. 3. The minimum distance between the hot air outlet and the underside of the mantle shelf is 330 mm. For distances over 600 mm, no heatshield is required. 4. The heatshields, as specified above, must be used to maintain clearances. Ensure heatshields extend the width and depth of underside of mantle shelf and key. 5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards when installed to enclosed dimensions. Test Reports: MED HCMG/04/025 & LGE HCMG/04/026 Clean Air Woodheating P/L Page 8

MANTLEPIECE INSTALLATION CLEARANCES VICTORIAN ZERO CLEARANCE WOODHEATER MEDIUM VICTORIAN 250 225 Min. 70 mm wide x KEYSHIELD 0 x 30 x 1 mm sheet metal 600 2 25 595 60 800 60 LARGE VICTORIAN 250 235 Min. 70 mm wide x KEYSHIELD 0 x 30 x 1 mm sheet metal 580 2 25 645 60 900 60 NOTE: 1. All dimensions are in millimetres. 2. Clearances are to combustible materials and are a minimum. 3. The minimum distance between the hot air outlet and the underside of the mantle shelf is 600 mm. 4. The heatshield and keyshield, as specified above, must be used to maintain clearances. Ensure heatshields extend the width and depth of underside of mantle shelf and key. 5. Clean Air Woodheaters tested by HRL Technology P/L to comply with Australian Standards when installed to enclosed dimensions. Test Reports: MED HCMG/04/025 & LGE HCMG/04/026 Clean Air Woodheating P/L Page 9

Bottom Flue Heat Shield Specifications A heat shield must be added to the front of the outer flue casing in order to maintain the clearances specified throughout these instructions. This heat shield is provided with the Maxiheat Zero Clearance Flue Kit. If you have purchased a different flue kit, please refer to the diagram below for the bottom flue heat shield requirements. 254 127 00 Corrosion protected sheet metal must be used. Material thickness - 0.7mm Clean Air Woodheating P/L Page