COMPRESSOR SERVICE REPLACEMENT KIT P/N (WCC 500A, 115/60, AIR COOLED)

Similar documents
ABS HOPPER LID SWITCH KIT ASSEMBLY

ED200/250 KSTYLE LID KITS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CH750, CH751 & CH951 CHILLERS

CH250 AND CH251 CHILLERS

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

VISUAL DISPLAY DISPENSER OWNERS MANUAL

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

ICE/BEVERAGE DISPENSER

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

CHILLER. Model CH3000. Operator s & Installation Manual

ILLUSTRATED PARTS LIST ENDURO VALVE

CHILLERS. Operator s & Installation Manual

CHILLER MODEL: CH1500, 2000 AND 3000

IMI CORNELIUS CHILLER

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual

ICE/BEVERAGE DISPENSER

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

FCB PINNACLE. Operator s Manual. 2 and 4 Flavor

STARBUCKS UC100 PROGATE

CONTINUOUS FLOW ICEMAKER

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

Manual No: Revision: D. Sump Sensor. Installation Guide

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Installation Instructions

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Installation Instructions

EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual

Installation Instructions

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1


HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

Installation Guide. Wind Baffle for Outdoor Units VRF-SVN079A-EN. VRF Single-Phase and C-Series Systems. October 2015 SAFETY WARNING

AVS Air Handlers Installation Manual for Classic SC, SD, and SDH

JetSpray Visual Display Dispenser JT20C

EarthLinked AVN Series Air Handlers Installation Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

Models , Equinox, and Sirens Clutch Replacement Service Manual

HX Series Recirculating Chiller Remote Condenser

1PIECE FREESTANDING BATHTUB

Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Installation & Operation Manual Ice Cream Freezers

Cincinnati, OH USA

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

QUANTUM SERIES Installation and Service Manual

RPI Industries, Inc.

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

InstructIon Manual KrEs EQuIPMEnt stands

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Installation Instructions

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

92831 TEL: (714) FAX:

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

EarthLinked AFN Series Air Handlers Installation Manual

Installation Instructions

GETZ MANUFACTURING PART # CYLINDER DRYER

Instruction Manual Refrigerated Counter Top Displays

Installation Instructions

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

INSTALLATION AND OPERATING MANUAL

C7 Series Split System Uncased Indoor Coils

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

MARTIN Insertable Dust Collector

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

AXIS Bodyweight Trainer Owner's Manual

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

INSTALLATION INSTRUCTIONS

AVANI Grinding Booth

SM Field Installed Electric Heat Kit

Panel Mounted Heat Exchangers by Dantherm, Inc.

Transcription:

COMPRESSOR SERVICE REPLACEMENT KIT P/N 629097166 (WCC 500A, 115/60, AIR COOLED) INSTALLATION INSTRUCTIONS Release Date: July 05, 2012 Publication Number: 620056387INS Revision Date: March 18, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

The products, technical information, and instructions contained in this manual are subject to change without notice. These instructions are not intended to cover all details or variations of the equipment, nor to provide for every possible contingency in the installation, operation or maintenance of this equipment. This manual assumes that the person(s) working on the equipment have been trained and are skilled in working with electrical, plumbing, pneumatic, and mechanical equipment. It is assumed that appropriate safety precautions are taken and that all local safety and construction requirements are being met, in addition to the information contained in this manual. This Product is warranted only as provided in Cornelius Commercial Warrant applicable to this Product and is subject to all of the restrictions and limitations contained in the Commercial Warranty. Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal service conditions with respect to the Product, (2) improper voltage, (3) inadequate wiring, (4) abuse, (5) accident, (6) alteration, (7) misuse, (8) neglect, (9) unauthorized repair or the failure to utilize suitably qualified and trained persons to perform service and/or repair of the Product, (10) improper cleaning, (11) failure to follow installation, operating, cleaning or maintenance instructions, (12) use of non-authorized parts (i.e., parts that are not 100% compatible with the Product) which use voids the entire warranty, (13) Product parts in contact with water or the product dispensed which are adversely impacted by changes in liquid scale or chemical composition. Contact Information: To inquire about current revisions of this and other documentation or for assistance with any Cornelius product contact: Trademarks and Copyrights: www.cornelius.com 800-238-3600 This document contains proprietary information and it may not be reproduced in any way without permission from Cornelius. This document contains the original instructions for the unit described. Printed in U.S.A. CORNELIUS INC 101 Regency Drive Glendale Heights, IL Tel: + 1 800-238-3600

COMPRESSOR SERVICE REPLACEMENT KIT! WARNING: Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment.! WARNING: Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. All wiring and plumbing must conform to national and local codes. Failure to comply could result in serious injury, death or equipment damage. These instructions describe how to install a replacement refrigeration compressor. Unpack and inspect the kit. Make sure all parts listed are present and in good condition. Loose-Shipped Parts Sl.No. Part Number Description Qty. 1 620054548 Compressor Copeland RST45 1 2 620054549 Compressor E-Box Assembly RST45 1 3 620055910 Set Mount Compressor 1 4 620055907 Tube Suction Line Assembly 1 5 620054227 Tube Discharge 1 6 620056299 Dryer Assembly 1 7 620056388 Label Compressor 1 8 620056305 Label External 1 9 169225015 Insulation 3/4ID X 3/8 wall 8 Ft. 10 620056168 Wire Harness 1 11 620055364 Cable Compressor 1 12 620055361 Wire Grounding 1 13 620056387INS Manual Installation Instructions 1 Figure 1. New Compressor with grommets 2012-2014, Cornelius Inc. - 1 - Publication Number: 620056387INS

REPLACEMENT COMPRESSOR 1. Remove the electrical connections from the existing Compressor E-Box and remove the existing Compressor cable. 2. Remove the existing Compressor E-Box from the base panel. 3. Disassemble and remove the existing compressor and Tubings (Debraze the condenser tubing) as per established procedures in handling refrigerants. 4. Drill a 0.157 diameter hole on the base panel as shown in Figure 2 for mounting the new Compressor E-Box. EXISTING COMPRESS Figure 2. Location of the hole to be drilled on base panel 5. Put the Label 620056388 on the new Compressor, just above the seam. Refer Figure 3. Figure 3. Compressor Sticker Publication Number: 620056387INS - 2-2012-2014, Cornelius Inc.

6. Position new compressor with grommets on the base panel and secure using bolts, washers. Figure 4. Schematic Showing the Orientation of the New Compressor 7. Release the Nitrogen from the Compressor. Connect the Discharge tube and Process tube as shown in Figure 5. Figure 5. Connection of Discharge Tube & Process Tube 2012-2014, Cornelius Inc. - 3 - Publication Number: 620056387INS

8. Connect the Dryer assembly as shown in Figure 6. Figure 6. Connection of the Dryer assembly 9. Connect the Suction HX assembly as shown in Figure 7. Figure 7. Connection of the Suction HX assembly 10. Braze the joints, evacuate and charge with refrigerant per established procedures in handling refrigerants. Make sure that TXV Bulb is not placed on Brazing bead/seam. Mount the TXV bulb in 12 Clock position. Publication Number: 620056387INS - 4-2012-2014, Cornelius Inc.

11. Insulate the suction line assembly and TXV as shown in Figure 8 and put the tie wraps firmly on the insulation. Figure 8. Refrigeration Layout Figure 9. Refrigeration Layout with New Tubings Highlighted 2012-2014, Cornelius Inc. - 5 - Publication Number: 620056387INS

12. Install the new compressor E-Box on the base frame. Refer Figure 10. Figure 10. Installation of New Compressor E-Box NOTE:Ensure that all electrical components i.e., Compressor, Condenser Fan Motor, Compressor E-Box and Control E-Box are properly grounded according to Federal, State and Local laws. 13. Connect electrical power and confirm proper operation. 14. Put the label 620056305 on the back panel below the serial label. Refer Figure 11. Figure 11. External Label Publication Number: 620056387INS - 6-2012-2014, Cornelius Inc.

Cornelius Inc. www.cornelius.com