P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Certification of Translation Accuracy Translation of Document from Dutch to English

Certifikat och provningsprotokoll för art och 4511

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

Schueco Fire and Smoke Protection Systems

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop. Pilkington Pyrodur

fire protection glass

STOPLINE FIRE RATED GLAZED

Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

fire protection glass

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

SGG CONTRAFLAM SAINT-GOBAIN GLASS PROTECT

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

CLASSIFICATION OF FUNCTION IN FIRE IN ACCORDANCE WITH DIN : with direct field of application FIRES-CR AUPE

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

SoaSA Technology International Ltd. Unit E,19/F, 2nd Wuhan Building Jiahe Road, Xiamen, Fujian China

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 31-2

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

FAÇADE FIRE TESTS Towards a new European standard method

GASTEC QA. Approval Requirements 31-1

Fire resistance test on fire collars protecting a concrete slab penetrated by services

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

KEEP THE FIRE FROM SPREADING

TFI Report Classification

Notification of a Body pursuant to article 10 of the Construction Products Directive 89/106/EEC

Photography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Additional reaction to fire classification report No H

2005-CVB-R0192 Onderzoek naar de mogelijke invloed van FirePro aërosol op in werking zijnde computerapparatuur

COMMISSION DELEGATED REGULATION (EU) /... of

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

General test 74 Thermal properties 75 Fire windows 75 Sound reduction 76 Safety 76 CWCT accreditation 77 Resistance to forced entry (SBD) 78

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

COMMISSION DECISION. of

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Development of a European approach to assess the fire performance of facades

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Test Report: ICL/CR15/11/087

The New Generationn of Firedoors

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Fire classification of construction products and building elements

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

0014-L-16/1 2 March Test report. EPDM Quickgoot system

Additional Reaction to Fire Classification Report

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

INTERNATIONAL STANDARD

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Conformity assessment procedures for the Alarm Components Scheme

25 th November Title:

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

COMMISSION DELEGATED REGULATION (EU) /... of

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

TFI Report Classification

Fire Rated Door Assemblies: Compliant Designs

International 3691 lap, 4

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Centexbel. General certification regulations. Construction products

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

Test Report No: ICL/H17/7967

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

GASTEC QA. Approval Requirements 69-1

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Form: KSD-100:10 Page 1 of 3

Construction Products Directive

Dear Customer. To update your printed copy of C/AS7, please make the following changes: Section Previous version January 2017 Amendment 4

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Transcription:

P.O. Box 554 - NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com Classification of the fire resistance of the Schüco FW50+ FR60 Curtain Wall system according to EN 13501-2:2007+A1:2009 Classification n o Sponsor Product name Karolinenstrasse 1 D-33609 Bielefeld GERMANY FW50+ FR60 Curtain Wall system Prepared by Efectis Nederland BV Brandpuntlaan Zuid 16 NL 2665 NZ BLEISWIJK The Netherlands Notified body n o 1234 Author(s) Dr.Ir. G. van den Berg P.A. Ram Project number 2013103 / 164 Date of issue Number of pages 20 All rights reserved. No part of this publication may be reproduced and/or published without the previous written consent of Efectis Nederland. Submitting the report for inspection to parties who have a direct interest is permitted. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions of TNO or the relevant agreement concluded between the contracting parties. 2013 Efectis Nederland BV Page 1 / 20

1. SUBJECT This classification report defines the resistance to fire classification assigned to the Schüco FW50+ FR60 Curtain Wall system in accordance with the procedures given in EN 13501-2:2007+A1:2009. 2. DETAILS OF CLASSIFIED PRODUCT 2.1 GENERAL A series of fire test was carried out on various versions of the Schüco FW50+ FR60 Curtain Wall system, see Figure 1 for a general lay-out of the system. Figure 1 A total of 5 fire tests have been performed on Full Configurations according to EN 1364-3. The results are reported in the following test reports: GRYFITlab test report LBO-129/10E, dated 17-01-2011 GRYFITlab test report LBO-151/10E, dated 18-01-2011 GRYFITlab test report LBO-143/10E, dated 17-01-2011 GRYFITlab test report LBO-253/11E, dated 13-10-2011 GRYFITlab test report LBO-168/11E, dated 30-06-2011 In addition, a fire test has been performed on a Partition Wall according to EN 1364-1. The results are reported in the following test report: IBS Linz test report 11070808, dated 02-11-2011 For the dimensions and specifications of the materials and significant details of the construction examined, see the next paragraphs 2.2 2.7. Based on these fire tests, the field of application for the Schüco Curtain Wall system has been This report consists of twenty pages and may only be used in its entirety. Page 2 / 20

defined. The field of application is determined on the basis of the test results obtained and the rules given in: the Direct Field of Application in pren 1364-3:2012 and the Extended Application in pren 15269-6:2012. This is reported in: Efectis NL report 2013-Efectis-R0103.164a, dated. A summary is given in paragraph 2.8. 2.2 GRYFITLAB TEST REPORT LBO-129/10E, DATED 17-01-2011 The test specimen was a Schüco FW50+ FR60 curtain wall with external dimensions 4630 x 4855 mm (w x h). The construction was glazed with Pilkington Pyrostop 60-181. At some locations, panels (based on 36 mm Promatect-H) were installed. The fire test was performed on 22 nd September 2010, according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from inside to outside. 2.3 GRYFITLAB TEST REPORT LBO-151/10E, DATED 18-01-2011 The test specimen was a Schüco FW50+ FR60 curtain wall with external dimensions 4630 x 4855 mm (w x h). The construction was glazed with Pilkington Pyrodur 60-252. At some locations, panels (based on 29 mm Promatect-H) were installed. The fire test was performed on 19 th November 2010, according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from inside to outside. 2.4 GRYFITLAB TEST REPORT LBO-143/10E, DATED 17-01-2011 The test specimen was a Schüco FW50+ FR60 curtain wall with external dimensions 4630 x 4955 mm (w x h). The construction was glazed with Pilkington Pyrostop 60-181. At some locations, panels (based on 36 mm Promatect-H) were installed. The fire test was performed on 22 nd October 2010, according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from outside to inside. 2.5 GRYFITLAB TEST REPORT LBO-253/11E, DATED 13-10-2011 The test specimen was a Schüco FW50+ FR60 curtain wall with external dimensions 3780 x 4955 mm (w x h). The construction was glazed with Pilkington Pyrodur 60-252. At some locations, panels (based on 29 mm Promatect-H) were installed. The fire test was performed on 16 th September 2011, according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from outside to inside. 2.6 GRYFITLAB TEST REPORT LBO-168/11E, DATED 30-06-2011 The test specimen was a Schüco FW50+ FR60 curtain wall, including double doors of type Schüco ADS 80 FR 60. The external dimensions of the test specimen were approx. 3800 x 3800 mm (w x h). The construction was fully glazed with Pilkington Pyrostop 60-181 in both the This report consists of twenty pages and may only be used in its entirety. Page 3 / 20

façade and the door leaves. The fire test was performed on 25 th January 2011, according to EN 1634-1:2009 with heat exposure according to the standard fire curve for the situation fire from inside to outside for the façade and with the door leaves pivoting away from the fire. 2.7 IBS LINZ TEST REPORT 11070808, DATED 02-11-2011 The test specimen was a Schüco FW50+ FR60 partition wall, with external dimensions approx. 2800 x 2800 mm (w x h). The construction was glazed with SGG Vetrotech Contraflam 60 (25 mm). The fire test was performed on 29 th March 2011, according to EN 1364-1:1999 with heat exposure according to the standard fire curve for the situation fire from inside to outside. 2.8 EFECTIS NL REPORT 2013-EFECTIS-R0103.164A, DATED JUNE 2013 Based on these fire tests, the field of application for the Schüco Curtain Wall system has been defined. The field of application is determined on the basis of the test results obtained and the rules given in: the Direct Field of Application in pren 1364-3:2012 and the Extended Application in pren 15269-6:2012. 3. TEST REPORTS & DEFINITION OF FIELD OF APPLICATION IN SUPPORT OF 3.1 TEST REPORTS Name of laboratory Name of sponsor Test report no. Test method GRYFITlab (Poland) Schüco International LBO-129/10E EN 1364-3:2007 GRYFITlab (Poland) Schüco International LBO-151/10E EN 1364-3:2007 GRYFITlab (Poland) Schüco International LBO-143/10E EN 1364-3:2007 GRYFITlab (Poland) Schüco International LBO-253/11E EN 1364-3:2007 GRYFITlab (Poland) Schüco International LBO-168/11E EN 1634-1:2009 IBS Linz (Austria) Schüco International 11070808 EN 1364-1:1999 This report consists of twenty pages and may only be used in its entirety. Page 4 / 20

3.2 TEST RESULTS Table 3.2.1 Summary of results GRYFITlab test report LBO-129/10E Fire test performed according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from inside to outside Integrity (E) Thermal insulation (I) 66 minutes (sustained flaming) 66 minutes (sustained flaming) Heating was terminated after 66 minutes. Table 3.2.2 Summary of results GRYFITlab test report LBO-151/10E Fire test performed according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from inside to outside Integrity (E) Thermal insulation (I) 61 minutes (no failure before end of heating) 61 minutes (no failure before end of heating) Heating was terminated after 61 minutes. Table 3.2.3 Summary of results GRYFITlab test report LBO-143/10E Fire test performed according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from outside to inside Integrity (E) Thermal insulation (I) 70 minutes (no failure before end of heating) 70 minutes (no failure before end of heating) Heating was terminated after 70 minutes. Table 3.2.4 Summary of results GRYFITlab test report LBO-253/11E Fire test performed according to EN 1364-3:2007 with heat exposure according to the standard fire curve for the situation fire from outside to inside Integrity (E) 66 minutes (no failure before end of heating) Thermal insulation (I) 66 minutes (maximum temperature rise on S1) Heating was terminated after 66 minutes. This report consists of twenty pages and may only be used in its entirety. Page 5 / 20

Table 3.2.5 Summary of results GRYFITlab test report LBO-168/11E Fire test performed according to EN 1634-1:2009 with heat exposure according to the standard fire curve for the situation fire from inside to outside for the façade and with the door leaves pivoting away from the fire Integrity (E) Thermal insulation I 1 I 2 66 minutes (no failure before end of heating) 51 minutes (measured on a door leaf) 66 minutes (measured on a door leaf) Heating was terminated after 66 minutes. Table 3.2.6 Summary of results IBS Linz test report 11070808 Fire test performed according to EN 1364-1:1999 with heat exposure according to the standard fire curve for the situation fire from inside to outside Integrity (E) 77 minutes (sustained flaming) Thermal insulation (I) 77 minutes (sustained flaming) Heating was terminated after 77 minutes. 3.3 DEFINITION OF FIELD OF APPLICATION Based on the fire tests referred to above, the field of application for the Schüco Curtain Wall FW50+ BF system has been defined. The field of application is determined on the basis of the test results obtained and the rules given in: the Direct Field of Application in pren 1364-3:2012 and the Extended Application in pren 15269-6:2012. 4. AND FIELD OF APPLICATION 4.1 REFERENCE OF This classification has been carried out in accordance with clause 7.5.3 of EN 13501-2:2007+A1:2009. 4.2 The fire resistance of curtain wall constructions in the Schüco FW50+ FR60 Curtain Wall system. This report consists of twenty pages and may only be used in its entirety. Page 6 / 20

Fire resistance classification of: E 15 (i o), E 30 (i o), E 60 (i o) EW 20 (i o), EW 30 (i o), EW 60 (i o) EI 15 (i o), EI 30 (i o), EI 60 (i o) 5. FIELD OF APPLICATION 5.1 GENERAL This classification is valid for the end use applications which are covered in the next sections. The approved constructions and variations thereof are based on the results obtained in the fire tests and the associated Field of Direct Application as given in pren 1364-3:2012. In addition, the rules as specified in the Extended Field of Application standard pren 15269-6:2012 have been used. 5.2 APPROVED CONFIGURATIONS The approved configurations are shown in Figure A.1 in Annex A. The information includes: - storey height - faceted facade - tested door size - angle for transoms/ mullions - sloped angle 5.3 BASIC AND SUPPLEMENTARY PROFILES The approved basic and supplementary profiles are shown in the Figures A.2 A.4 in Annex A. The information includes: - mullions - transoms - cover caps FW 50+ FR 60 5.4 INFILL PANELS The approved infill panels are shown in Figure A.5 in Annex A. The information includes: - glazing options 5.5 ACCESSORIES The approved accessories are shown in the Figures A.6 and A.7 in Annex A. The information includes: - insulation types and intumescent strips - gaskets, glazing supports, T-connections This report consists of twenty pages and may only be used in its entirety. Page 7 / 20

5.6 INSERT UNITS The approved door and window constructions which are to be integrated in the curtain wall system are shown in Figure A.8 in Annex A. The information includes: - Integration of fire resistant door ADS 80 FR 60 Only the door and window configurations as tested are included. A further assessment of alternative door and window configurations is to be based on the rules in EN 1634-1 and the applicable part in the EN 15269-series. This is not part of the present classification. 5.7 SUPPORTING STRUCTURE / ANCHORING The supporting constructions into which the curtain wall system is to be installed are shown in the Figures A.9 A.12 in Annex A. The information includes: - sill attachment - head attachment - side attachments 6. LIMITATIONS This classification document does not represent type approval or certification of the product. SIGNED APPROVED Dr. G. van den Berg Senior project leader fire resistance P.A. Ram Project leader fire resistance This report consists of twenty pages and may only be used in its entirety. Page 8 / 20

ANNEX A DRAWINGS FOR THE CURTAIN WALL SYSTEM FW 50+ FR 60 Figure A.1 This report consists of twenty pages and may only be used in its entirety. Page 9 / 20

Figure A.2 This report consists of twenty pages and may only be used in its entirety. Page 10 / 20

Figure A.3 This report consists of twenty pages and may only be used in its entirety. Page 11 / 20

Figure A.4 This report consists of twenty pages and may only be used in its entirety. Page 12 / 20

Figure A.5 This report consists of twenty pages and may only be used in its entirety. Page 13 / 20

Figure A.6 This report consists of twenty pages and may only be used in its entirety. Page 14 / 20

Figure A.7 This report consists of twenty pages and may only be used in its entirety. Page 15 / 20

Figure A.8 This report consists of twenty pages and may only be used in its entirety. Page 16 / 20

Figure A.9 This report consists of twenty pages and may only be used in its entirety. Page 17 / 20

Figure A.10 This report consists of twenty pages and may only be used in its entirety. Page 18 / 20

Figure A.11 This report consists of twenty pages and may only be used in its entirety. Page 19 / 20

Figure A.12 This report consists of twenty pages and may only be used in its entirety. Page 20 / 20