Product Information and Technical Guide

Similar documents
Product Information and Technical Guide

Room Air Conditioner Service and Parts Manual

Product Information and Technical Guide

Room Air Conditioner Service and Parts Manual

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

Product Information and Technical Guide

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Product Information and Technical Guide

Product Information and Technical Guide

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Thru-the-Wall Series

Service. Compact Quiet Zone Room Air Conditioners

Service Manual Electric Cooktop

SERVICE DATA SHEET (9704) Rev. D

Room Air Conditioner Service and Parts Manual

Servi. Sli e C Air C. Amana AAC081SRA AAC101SRA AAC121SRA AAC141SRA AAC182SRA AAC202SRA AAC242SRA

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

Thru-the-Wall Series

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

Window Y9USC/E 09 / 12 / 18 B5R

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

AIR CONDITIONER ELECTRONIC CONTROL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

SLIDER CASEMENT AIR CONDITIONER

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

ROTARY CONTROL AIR CONDITIONER

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Room Air Conditioner

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Servi. Sli e Chassis Air C. i io AAC081SRB. Amana

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

User s Information and Installation Instructions

KM-61BAH KM-101BAH KM-151BAH

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Operating & Maintenance Manual for Islandaire EZ Series WM/LM Water Source Heat Pump Packaged Terminal Air Conditioners.

SERVICE MANUAL. Room Air Conditioner

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

InstructIon Manual KrEs EQuIPMEnt stands

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

Split Floor-Mounted Cooling System Operation Care Installation Manual

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

LG Room Air Conditioner

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E

T-Series Air Conditioner T20 Model

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00014EB

THRU-THE-WALL AIR CONDITIONERS

KM-630MAH KM-630MWH KM-630MRH

Low Profile. Baseboard Heater

TECHNICAL SERVICE GUIDE

AH-600 Baseboard Heater

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

INSTRUCTIONS! DO NOT DISCARD!

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

SERVICE MANUAL OFFICE PRO 60. Unit Serial Number Range: 0407XXXX600 to Present (From April 2007 to Present)

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

T-Series Air Conditioner T15 Model

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

AE/AH R410A Window Air Conditioners & Heat Pumps

Installation & Service Manual

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Transcription:

Product Information and Technical Guide 2004 Room Air Conditioners MS2 and Compact 2 Models Safe Servicing Practices 3 Model Specifications 4-11 Compressor Overloads 12 Restrictor Tube Data 12 Receptacle Codes 13 Product Dimensions 14 Thermostat s 14 ATTENTION SERVICERS! To get a helping hand, visit the Frigidaire Web Site at: http://www.frigidaire.com User name: service Password: tips Fan/Blower s 15 Wiring s 16-20 Troubleshooting 21-23 5995414041 August 2004

TABLE OF CONTENTS Safe Servicing Practices...3 Model Specifications...4-11 Compressor Overload Data...12 Restrictor Tube Data...12 Receptacle Outlet Codes...13 Product Dimensions...14 Control Thermostat Location s...14 Fan and Blower Location s...15 Wiring s...16-20 2202019075...16 2202019169...16 2202039242...17 2202039277...18 2202049158...19 2202049160...20 Troubleshooting...21-23 2

SAFE SERVICING PRACTICES - ALL APPLIANCES To avoid personal injury or property damage, it is important that Safe Servicing Practices be observed. The following are some limited examples of safe practices. 1. DO NOT attempt a product repair if you doubt your ability to complete it in a safe and satisfactory manner. 2. Before servicing or moving an appliance Remove power cord from electrical outlet, trip circuit breaker to OFF position, or remove fuse Turn off gas supply Turn off water supply 3. Never interfere with the proper operation of any safety device. 4. Use only OEM replacement parts cataloged for this appliance. Substitutions may defeat compliance with safety standards set for home appliances. 5. GROUNDING: The standard color coding for safety ground wires is GREEN, or GREEN with YELLOW STRIPES. DO NOT use ground leads as current carrying conductors. It is EXTREMELY important that the service technician reestablish all safety grounds prior to completing service. Failure to do so will create an electrical hazard. 6. Prior to returning the product to service, ensure that All electrical connections are correct and secure All electrical leads are properly dressed and secured away from sharp edges, high-temperature components, and moving parts All non-insulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal parts and panels All safety grounds (both internal and external) are correctly and securely connected All panels are properly and securely reassembled WARNING This service manual is intended for use by persons having electrical and mechanical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. Electrolux Home Products, Inc. cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of this manual. 2004 Electrolux Home Products, Inc. 3

FRIGIDAIRE MODEL SPECIFICATIONS Model FAA051N7A FAA051N7A1 FAA051N7A2 FAA051N7A3 FAA052N7A Chassis type MS 2 MS 2 MS 2 MS 2 MS 2 Capacity features BTU - Cooling 5000 5000 5000 5000 5000 BTU - Heating Moisture Removal 1.45 1.45 1.45 1.45 1.45 EER 9.7 9.7 9.7 9.7 9.7 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 4.6 4.6 4.6 4.6 4.6 Amps - Heating Watts - Cooling 515 515 515 515 515 Watts - Heating Fuse/Breaker (Amps) 10 10 10 10 10 Receptacle Code A A A A A Wiring 2202019169 2202019169 2202019169 2202019169 2202019075 Page # 16 16 16 16 16 Air Flow System 6/250 6/250 6/250 6/250 6/250 Fan Motor Mfg. Welling Dayang Welling Dayang Welling Fan Motor Number 2240040611 2240040611 2240040611 2240040611 2240040612 RPM/CMP (EVAP) High 1120/240 1120/240 1120/240 1120/240 1120/240 Medium - - - - 920/180 Low Heat Only Refrigeration System Compressor Mfg. Shenlin, Shanghai Shenlin, Shanghai Matsushita Matsushita Shenlin, Shanghai Compressor Number SD074SW-P3BG SD074SW-P3BG 2R7S3R126A6A 2R7S3R126A6A SD074SW-P3BG Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140131210 2140131210 2140011600 2140011600 2140131210 35/250 35/250 35/250 35/250 35/250 Refrigerant Charge 9.9 9.9 9.9 9.9 9.9 Restrictor Tube 2162019061 2162019061 2162019017 2162019017 2162019061 Thermostat Type Capillary Capillary Capillary Capillary Capillary Installation Instructions Kit Type Part Number 2282019010 2282019010 2282019010 2282019010 2282019010 Control Thermostat Location Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 4

FRIGIDAIRE MODEL SPECIFICATIONS Model FAA052N7A1 FAA052N7A2 FAA052N7A3 FAA055N7A FAA055N7A1 Chassis type MS 2 MS 2 MS 2 MS 2 MS 2 Capacity features BTU - Cooling 5000 5000 5000 5200 5200 BTU - Heating Moisture Removal 1.45 1.45 1.45 1.5 1.5 EER 9.7 9.7 9.7 11 11 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 4.6 4.6 4.6 4.2 4.2 Amps - Heating Watts - Cooling 515 515 515 472 472 Watts - Heating Fuse/Breaker (Amps) 10 10 10 10 10 Receptacle Code A A A A A Wiring 2202019075 2202019075 2202019075 2202039277 2202039277 Page # 16 16 16 18 18 Air Flow System 6/250 6/250 6/250 6/250 6/250 Fan Motor Mfg. Dayang Welling Dayang Welling Dayang Fan Motor Number 2240040612 2240040612 2240040612 2240040611 2240040611 RPM/CMP (EVAP) High 1120/240 1120/240 1120/240 1120/240 1120/240 Medium 920/180 920/180 920/180 920/180 920/180 Low Heat Only Refrigeration System Compressor Mfg. Shenlin, Shanghai Matsushita Matsushita Shenlin, Shanghai Shenlin, Shanghai Compressor Number SD074SW-P3BG 2R7S3R126A6A 2R7S3R126A6A SD074SW-P3BG SD074SW-P3BG Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140131210 2140011600 2140011600 2140131210 2140131210 35/250 35/250 35/250 35/250 35/250 Refrigerant Charge 9.9 9.9 9.9 12.3 12.3 Restrictor Tube 2162019061 2162019017 2162019017 2162019015 2162019015 Thermostat Type Capillary Capillary Capillary Electronic Electronic Installation Instructions Kit Type Part Number 2282019010 2282019010 2282019010 2282019010 2282019010 Control Thermostat Location Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 5

FRIGIDAIRE MODEL SPECIFICATIONS Model FAA055N7A2 FAA055N7A3 FAA064N7A FAA064N7A1 FAA064N7A2 Chassis type MS 2 MS 2 MS 2 MS 2 MS 2 Capacity features BTU - Cooling 5200 5200 6000 6000 6000 BTU - Heating Moisture Removal 1.5 1.5 1.85 1.85 1.85 EER 11 11 9.7 9.7 9.7 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 4.2 4.2 5.5 5.5 5.5 Amps - Heating Watts - Cooling 472 472 620 620 620 Watts - Heating Fuse/Breaker (Amps) 10 10 10 10 10 Receptacle Code A A A A A Wiring 2202039277 2202039277 2202039242 2202039242 2202039242 Page # 18 18 17 17 17 Air Flow System 6/250 6/250 6/250 6/250 6/250 Fan Motor Mfg. Welling Dayang Welling Dayang Welling Fan Motor Number 2240040611 2240040611 2240040611 2240040611 2240040611 RPM/CMP (EVAP) High 1120/240 1120/240 1120/220 1120/220 1120/220 Medium 920/180 920/180 - - - Low - - 920/170 920/170 920/170 Heat Only Refrigeration System Compressor Mfg. Matsushita Matsushita LG LG Shenlin, Shanghai Compressor Number 2R7S3R126A6A 2R7S3R126A6A QA084CAA QA084CAA SD086UW-P3BG Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140011600 2140011600 2140160370 2140160370 2140131220 35/250 35/250 35/250 35/250 40/250 Refrigerant Charge 12.3 12.3 13.4 13.4 13.4 Restrictor Tube 2162019015 2162019015 2162029029 2162029029 2162029029 Thermostat Type Electronic Electronic Electronic Electronic Electronic Installation Instructions Kit Type Part Number 2282019010 2282019010 2282019010 2282019010 2282019010 Control Thermostat Location Page 14 Page 14 Page 14 Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 6

FRIGIDAIRE MODEL SPECIFICATIONS Model FAA064N7A3 FAA065N7A FAA065N7A1 FAA065N7A2 FAA065N7A3 Chassis type MS 2 MS 2 MS 2 MS 2 MS 2 Capacity features BTU - Cooling 6000 6000 6000 6000 6000 BTU - Heating Moisture Removal 1.85 1.9 1.9 1.9 1.9 EER 9.7 10.7 10.7 10.7 10.7 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 5.5 4.9 4.9 4.9 4.9 Amps - Heating Watts - Cooling 620 560 560 560 560 Watts - Heating Fuse/Breaker (Amps) 10 10 10 10 10 Receptacle Code A A A A A Wiring 2202039242 2202039277 2202039277 2202039277 2202039277 Page # 17 18 18 18 18 Air Flow System 6/250 6/250 6/250 6/250 6/250 Fan Motor Mfg. Dayang Welling Dayang Welling Dayang Fan Motor Number 2240040611 2240040611 2240040611 2240040611 2240040611 RPM/CMP (EVAP) High 1120/220 1120/220 1120/220 1120/220 1120/220 Medium Low 920/170 920/170 920/170 920/170 920/170 Heat Only Refrigeration System Compressor Mfg. Shenlin, Shanghai LG LG Shenlin, Shanghai Shenlin, Shanghai Compressor Number SD086UW-P3BG QA084CAA QA084CAA SD086UW-P3BG SD086UW-P3BG Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140131220 2140160370 2140160370 2140131220 2140131220 40/250 35/250 35/250 40/250 40/250 Refrigerant Charge 13.4 17.3 17.3 17.3 17.3 Restrictor Tube 2162029029 2162029029 2162029029 2162029029 2162029029 Thermostat Type Electronic Electronic Electronic Electronic Electronic Installation Instructions Kit Type Part Number 2282019010 2282019010 2282019010 2282019010 2282019010 Control Thermostat Location Page 14 Page 14 Page 14 Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 7

FRIGIDAIRE MODEL SPECIFICATIONS Model FAC084N7A FAC084N7A1 FAC084N7A2 FAC085N7A FAC085N7A1 Chassis type Compact 2 Compact 2 Compact 2 Compact 2 Compact 2 Capacity features BTU - Cooling 8000 8000 8000 8000 8000 BTU - Heating Moisture Removal 1.7 1.7 1.7 1.7 1.7 EER 9.8 9.8 9.8 10.8 10.8 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 7.4 7.4 7.4 6.4 6.4 Amps - Heating Watts - Cooling 820 820 820 740 740 Watts - Heating Fuse/Breaker (Amps) 15 15 15 15 15 Receptacle Code A A A A A Wiring 2202039242 2202039242 2202039242 2202039277 2202039277 Page # 17 17 17 18 18 Air Flow System 15/250 15/250 15/250 15/250 15/250 Fan Motor Mfg. Heshan Dayang Welling Heshan Dayang Fan Motor Number 2240042425 2240042425 2240042425 2240042425 2240042425 RPM/CMP (EVAP) High 1250/265 1250/265 1250/265 1250/265 1250/265 Medium Low 1050/210 1050/210 1050/210 1050/210 1050/210 Heat Only Refrigeration System Compressor Mfg. Matsushita Matsushita Matsushita Matsushita Matsushita Compressor Number 2R11S3R126A6B 2R11S3R126A6B 2R11S3R126A6B 2R11S3R126A6B 2R11S3R126A6B Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140021580 2140021580 2140021580 2140021580 2140021580 35/250 35/250 35/250 35/250 35/250 Refrigerant Charge 16.9 16.9 16.9 20.1 20.1 Restrictor Tube 2162039034 2162039034 2162039034 2162039027 2162039027 Thermostat Type Electronic Electronic Electronic Electronic Electronic Installation Instructions Kit Type Part Number 2282049504 2282049504 2282049504 2282049504 2282049504 Control Thermostat Location Page 14 Page 14 Page 14 Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 8

FRIGIDAIRE MODEL SPECIFICATIONS Model FAC085N7A2 FAC086N7A FAC086N7A1 FAC086N7A2 FAC104N1A Chassis type Compact 2 Compact 2 Compact 2 Compact 2 Compact 2 Capacity features BTU - Cooling 8000 8000 8000 8000 10000 BTU - Heating Moisture Removal 1.7 1.7 1.7 1.7 1.7 EER 10.8 10.8 10.8 10.8 9.7 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 6.4 6.4 6.4 6.4 9.3 Amps - Heating Watts - Cooling 740 740 740 740 1020 Watts - Heating Fuse/Breaker (Amps) 15 15 15 15 15 Receptacle Code A A A A A Wiring 2202039277 2202039277 2202039277 2202039277 2202049160 Page # 18 18 18 18 20 Air Flow System 15/250 15/250 15/250 15/250 15/250 Fan Motor Mfg. Welling Heshan Dayang Welling Welling Fan Motor Number 2240042425 2240042425 2240042425 2240042425 2240049106 RPM/CMP (EVAP) High 1250/265 1250/265 1250/265 1250/265 1460/295 Medium Low 1050/210 1050/210 1050/210 1050/210 1260/240 Heat Only Refrigeration System Compressor Mfg. Matsushita Matsushita Matsushita Matsushita Gold Star Compressor Number 2R11S3R126A6B 2R11S3R126A6B 2R11S3R126A6B 2R11S3R126A6B QK141CBC Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140021580 2140021580 2140021580 2140021580 2140160360 35/250 35/250 35/250 35/250 45/250 Refrigerant Charge 20.1 20.1 20.1 20.1 20.5 Restrictor Tube 2162039027 2162039027 2162039027 2162039027 2162049155 Thermostat Type Electronic Electronic Electronic Electronic Electronic Installation Instructions Kit Type Part Number 2282049504 2282049504 2282049504 2282049504 2282049504 Control Thermostat Location Page 14 Page 14 Page 14 Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 9

FRIGIDAIRE MODEL SPECIFICATIONS Model FAC104N1A1 FAC106N1A FAC106N1A1 FAC124N1A FAC124N1A1 Chassis type Compact 2 Compact 2 Compact 2 Compact 2 Compact 2 Capacity features BTU - Cooling 10000 10000 10000 12000 12000 BTU - Heating Moisture Removal 1.7 2.7 2.7 3.6 3.6 EER 9.7 10.7 10.7 9.8 9.8 Electrical Information Voltage 115 115 115 115 115 Amps - Cooling 9.3 8.4 8.4 11.1 11.1 Amps - Heating Watts - Cooling 1020 925 925 1230 1230 Watts - Heating Fuse/Breaker (Amps) 15 15 15 15 15 Receptacle Code A A A A A Wiring 2202049160 2202049158 2202049158 2202049160 2202049160 Page # 20 19 19 20 20 Air Flow System 15/250 15/250 15/250 15/250 15/250 Fan Motor Mfg. Dayang Welling Dayang Welling Dayang Fan Motor Number 2240049106 2240049106 2240049106 2240049106 2240049106 RPM/CMP (EVAP) High 1460/295 1460/295 1460/295 1460/295 1460/295 Medium - - - 1260/240 1260/240 Low 1260/240 1260/240 1260/240 - - Heat Only Refrigeration System Compressor Mfg. Gold Star Gold Star Gold Star Gold Star Gold Star Compressor Number QK141CBC QK134CCB QK134CCB QK164CBB QK164CBB Compressor Type Rotary Rotary Rotary Rotary Rotary Overload Protector 2140160360 2140160350 2140160350 2140160340 2140160340 45/250 50/250 50/250 50/250 50/250 Refrigerant Charge 20.5 22.9 22.9 23.6 23.6 Restrictor Tube 2162049155 2162049149 2162049149 2162049145 2162049145 Thermostat Type Electronic Electronic Electronic Electronic Electronic Installation Instructions Kit Type Part Number 2282049504 2282049504 2282049504 2282049504 2282049504 Control Thermostat Location Page 14 Page 14 Page 14 Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 Page 15 Page 15 Page 15 10

FRIGIDAIRE MODEL SPECIFICATIONS Model FAC126N1A FAC126N1A1 Chassis type Compact 2 Compact 2 Capacity features BTU - Cooling 12000 12000 BTU - Heating - - Moisture Removal 3.6 3.6 EER 10.8 10.8 Electrical Information Voltage 115 115 Amps - Cooling 10.1 10.1 Amps - Heating - - Watts - Cooling 1110 1110 Watts - Heating - - Fuse/Breaker (Amps) 15 15 Receptacle Code A A Wiring 2202049158 2202049158 Page # 19 19 Air Flow System 15/250 15/250 Fan Motor Mfg. Welling Dayang Fan Motor Number 2240049106 2240049106 RPM/CMP (EVAP) High 1460/295 1460/295 Medium 1260/240 1260/240 Low - - Heat Only - - Refrigeration System Compressor Mfg. Gold Star Gold Star Compressor Number QK164CDB QK164CDB Compressor Type Rotary Rotary Overload Protector 2140160330 2140160330 60/250 60/250 Refrigerant Charge 27.2 27.2 Restrictor Tube 2162049137 2162049137 Thermostat Type Electronic Electronic Installation Instructions Kit Type Part Number 2282049504 2282049504 Control Thermostat Location Page 14 Page 14 Condenser Fan and Evaporator Blower Location Page 15 Page 15 11

COMPRESSOR OVERLOAD DATA Part# Used with compressor Supplier part # Opening Temp Closing Temp Short Time Trip C ± 5 C C ± 5 C Test Amp Opening Time - Sec 2140131210 SD074SW-P3BG LOGN21A/LYGN56A 160±10 70±10 18A/12A 5~15Sec 2140011600 2R7S3R126A6A MRA99087 135±5 75±9 19.5A 6~11Sec 2140131220 SD086UW-P3BG LOGN21A/LYGN56A 160±10 70±10 18A/12A 5~15Sec 2140160370 QA084CAA MRA98703-12026 140±5 78±10 21A 5~11Sec 2140021580 2R11S3R126A6B MRA98705 155±5 74±9 25.5A 6~16Sec 2140160360 QK141CBC MRA12061-12026 150±5 61±11 40.5A 5~11Sec 2140160350 QK134CCB MRA12061-12026 150±5 61±11 50.5A 5~11Sec 2140160340 QK164CBB MRA12053-12027 150±5 61±9 41.5A 5~11Sec 2140160330 QK164CDB MRA12061-12026 150±5 61±11 50.5A 5~11Sec RESTRICTED TUBE DATA Style # Internal Diameter CFM Dry Air Length O.D. I.D. PSIG Color Code Min. Max. 2162019017 27.6 0.098 0.043 20 0.865 0.936 2162019061 25.6 0.098 0.043 20 0.900 0.971 2162019015 42.5 0.098 0.051 15 1.119 1.190 2162029029 37.4 0.098 0.051 15 1.148 1.218 2162039027 27.6+29.5 0.098 0.043 20 0.883+0.847 0.953+0.918 2162039034 31.5+33.5 0.098 0.043 20 0.812+0.795 0.883+0.865 2162049149 35.4+39.4+41.3 0.098 0.043 20 0.812+0.716+0.706 0.883+0.787+0.776 2142049155 41.3+43.3 0.098 0.051 15 1.130+1.095 1.201+1.165 2162049137 26.8+33.9+33.9 0.098 0.043 20 0.890+0.763+0.777 0.960+0.833+0.847 2162049145 31.5+39.4+37.4 0.098 0.043 20 0.847+0.713+0.787 0.918+0.784+0.858 12

Receptacle Outlet Codes Code A 115 Volts - 15 Amps NEMA 5-15 TYPE Code B 115 Volts - 20 Amps NEMA 5-20 TYPE Code C 230 Volts - 15 Amps NEMA 6-20 TYPE Power Supply Cord with 3-prong Grounding Plug Code D 230 Volts - 20 Amps NEMA 6-20 TYPE Grounding Type Wall Receptacle Code E 230 Volts - 30 Amps NEMA 6-30 TYPE 13

Product Dimensions Control Thermostat Location s MS2 Rotary Controls MS2 Electronic Controls The 4th pipe The 4th pipe The 5th pipe 4 2 4 Compact 2 The 4th pipe The 5th pipe 3.2 14

Fan and Blower Location s MS 2 MODELS COMPACT 2 MODELS 0.2 0.52 15

Wiring s 2202019075 2202019169 16

Wiring s 2202039242 17

Wiring s 2202039277 18

Wiring s 2202049158 19

Wiring s 2202049160 20

ROOM AIR CONDITIONERS TROUBLESHOOTING CAUTION: Review Safe Servicing Practices in the front of this manual before attempting diagnostic procedures and repairs. AIR CONDITIONER VOLTAGE LIMITS NAMEPLATE RATING MINIMUM MAXIMU M 115 VAC 103.5 VAC 126.5 VAC 230 VAC 207 VAC 253 VAC 208/230 197.5 VAC 253 VAC AIR CONDITIONER VOLTAGE LIMITS Low voltage is a common cause of trouble in the operation of any room air conditioner. Improper voltage may cause one or more of the following problems: 1. Unit will not start. 2. Compressor motor cycling on motor protector. 3. Premature failure of motor protector. 4. Blown fuses. 5. Premature failure of compressor or fan motor. 6. Noticable dimming of lights when air conditioner is running. 7. Evaporator icing. Low voltage may reduce fan speed resulting in inadequate air flow over evaporator, thereby allowing it to ice up. Low voltage can also be the direct result of inadequately wired circuits, extension cords, or loose fuses and connections to the power supply. Voltage may also be a general condition in the area (a responsibility of the power company). All units will start and run on the minimum voltage stated in the chart to the left, and will perform satisfactorily if the voltage remains constant. Low voltage caused by defective wiring will not remain constant under load. To test for low voltage, use a reliable meter with sufficient capacity to measure the required voltage. Take measurements at the electric power entry point and at the electric outlet serving the air conditioner. Take readings with the unit off, while the unit is starting, and again while the unit is running. The lowest reading should not drop below the lowest value listed in the chart. HIGH VOLTAGE High voltage can be equally troublesome, causing motors to overheat, cycle on their protectors, or break down electrically. This problem can only be solved by the power company. ELECTRONIC CONTROL This control is not repairable. If any component in the control is defective, the entire control must be replaced. IMPORTANT NOTICE: Repair or replace any malfunctioning line voltage component before testing or replacing the electronic control. DO NOT assume a service problem is directly caused by the electronic control system. A line voltage component (including power cord and wiring) that has opened, shorted, grounded or otherwise malfunctioned, may have created a service problem. SYMPTON POSSIBLE CAUSE Fan motor will not run. 1. No power. 2. Power supply cord. 3. Selector switch. 4. Energy saving switch (if applicable). 5. Electronic control (if applicable). 6. Wire disconnected or connection loose. 7. Capacitor. (Discharge capacitor before testing.) 8. Defective fan motor windings. 9. Will not rotate. Fan blade hitting shroud or blower wheel hitting scroll. (Motor cycles on overload.) Fan motor runs intermittently. 1. Cycle on motor protector. 21

SYMPTON POSSIBLE CAUSE Fan motor noisy. 1. Condenser fan blade or evaporator blower wheel. 2. Loose power clamp or set screw. 3. Worn bearings. 4. Grommets (if applicable). Compressor will not run, but fan motor runs. 1. Voltage. 2. Wiring. 3. Selector switch. 4. Temperature control. 5. Capacitor. (Discharge capacitor before testing.) 6. Compressor. 7. Motor protector (external). 8. Motor protector (internal). 9. Electronic control (if applicable). 10. Hard starting. Compressor cycles on motor protector. 1. Voltage. 2. Motor protector (external). 3. Motor protector (internal). 4. Fan motor. 5. Condenser air flow restriction. 6. Condenser fins damanged. 7. Capacitor. 8. Wiring. 9. Refrigerant system. Insufficient cooling. 1. Low capacity. 2. Air filter. 3. Exhaust door open. 4. Unit undersized. Excessive noise. 1. Evaporator blower wheel. 2. Condenser wheel. 3. Copper tubing. 4. Compressor internal noise. 5. Fan motor. Excessive water or condensation. 1. Unit operating under extremely high humidity conditions. No cooling. 1. Refrigerant leak. Unit is cooling but room is not cool. 1. Amps and watts. 2. Sealed refrigeration system. Wattage decreases slowly until abnormally low. 1. Undercharged, restricted strainer or plugged restrictor tube. Wattage decreases immediately. 1. No refrigerant. 2. Compressor defective. Wattage continuously high. 1. Refrigerant overcharge. 22

SYMPTON POSSIBLE CAUSE Evaporator coil partially frosted. 1. System low on refrigerant. Evaporator completely iced. 1. Low outside temperature. No heat. 1. No power. 2. Selector switch position. 3. Temperature control position. 4. Fan motor. 5. Heating element. 6. Selector switch. 7. Temperature control. 8. Terminals and connectors. Fan motor will not rotate during heat cycle. 1. Thermostatic drain valve. (Water level control, if (Heat/Cool models only.) applicable.) 23