INSTRUCTIONS for installation and use

Similar documents
INSTRUCTIONS for installation and use

INSTRUCTIONS for installation and use

INSTALLATION MANUAL. Rangetops. RNB Heritage Classic Platinum

INSTALLATION MANUAL. Free Standing Ranges. RCS (Open/Sealed) RNB RPB Platinum Precious Metals 1

INSTALLATION MANUAL. Free Standing Ranges. RCS (Open/Sealed) RNB RPB Platinum Precious Metals 1

OPERATION & MAINTENANCE INSTRUCTIONS

Gas Cooktop Installation, User and Service Instructions GMS 955.1

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation

DESIGN CLASS FUNCTION

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

INSTALLATION INSTRUCTIONS

TRI-STAR INC SOUTH STANDARD AVENUE, SANTA ANA, CA Ph: Fax: MODEL #. OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS Carefully read the following Important information redarding installation safety and maintenance.

USER MANUAL Gas Countertop Charbroilers

Operator s Manual CAYENNE GAS COUNTERTOP CHAR BROILER ENGLISH

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

PC 640 GB. Built-in cooking tables 60 Instructions for installation and use

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18

Installation / Assembly

Using it in an enclosed space can kill you.

Viking Installation Guide

Installation Instructions Dual Fuel Ranges

Owner s Guide Installation & Operation

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Installation, Service and User Instructions Built-in gas cooktops BERTAZZONI

Stone Hearth Pizza Dome Oven

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

R-RCM & R-RSB SERIES

V SERIES HDR GAS RANGES

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

INSTALLATION MANUAL. Double Electric Wall Oven

Proline GAS HOB Model TCG40IX Instruction Book

STAR-MAX PROPANE GAS GRIDDLE

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

USER MANUAL Stock Pot Range

PRO SERIES GAS FRYERS OWNER S MANUAL

CINCINNATI, OH USA

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

GAS COOKTOP INSTALLATION INSTRUCTIONS

CBO-750 HYBRID-R OVEN Instructions Manual

Viking Installation Guide

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE CONVECTION OVEN MODEL # RDCO-32

Operating and Installation Instructions

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

GAS COOKER GAS OVEN SERIES. Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

Operating and Installation Instructions

Viking Installation Guide

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

Installation Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

USER MANUAL Gas Step Up Hot Plate

PROF. RANGE COOKER MODEL: EPRC-9850FE/SS EPRC-9860E/SS. Owner s Manual Please read this manual carefully before operating your set.

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

Group. Virtus Group GmbH Hüserstraße Hamm / Germany. Virtus s.r.l. via Milano 95/e Casteggio (PV) / Italy

User Manual. 600mm, 700mm & 900mm Gas Cooktops Model No. CF6GS, CF6GW, CF7GS, CF9GS

LGB Gas fired boiler

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Installation Instructions

Natural Gas Conversion Instruction for

Installation Instructions

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

JADE TACO RANGES MODEL: JTR and JTRB Series JADE STOCK POT RANGES MODEL: JSP Series

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

DESIGN CLASS FUNCTION

CYLINDER NOT INCLUDED

INSTRUCTION MANUAL. Full Size Gas Convection Oven

Multi-Function Cooktop

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

INSTALLATION INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Porter & Charles OPERATION MANUAL. Gas Cooktop CG60S, CG76S, CG90S, CG60W, CG90W

UBGHFF60W 60cm Gas on Glass Gas Hob

Installation instructions for the T 9820 Gas Dryer

Installation. Freestanding 30 Gas Self-Clean Sealed Burner Range

F900 SERIES BOILING PAN G9781. User, installation and servicing instructions. Read these instructions before use T REV.

Gourmet Freestanding Range Gas Cooktop Electric Oven

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Legend VENTED GAS FIREPLACE HEATERS

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Transcription:

GEPS12MP GAS RANGE WITH OVEN FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS for installation and use

TABLE OF CONTENTS WARNINGS & CAUTION...4 SAFETY INSTRUCTIONS...5 BURNER ASSEMBLY DIAGRAM...6 INSTALLATION INTRUCTIONS...10 USE AND MAINTENANCE INSTRUCTIONS...18 CLEANING AND CARE INSTRUCTIONS...21

WARNINGS & CAUTION 1. Before using the appliance, read the instruction manual carefully, as it contains important safety information on the proper installation, use and maintenance of the appliance. Please keep the instruction manual for further reference. 2. The appliance s electrical safety is guaranteed only if the electrical system is grounded in accordance with the relevant regulations. It is of the utmost importance to follow such regulations; when in doubt, please consult a qualified electrician to have the electrical system thoroughly checked. The manufacturer declines all responsibility for damage caused by a improperly grounded electrical system 3. Before connecting the appliance, make sure that the appliance s technical characteristics shown on the tag correspond to those of the electrical system and gas supply. 4. Make sure that the electrical system and sockets can handle the appliance s maximum power consumption as shown on the tag. When in doubt, please consult a qualified electrician. 5. When not in use for extended periods, switch off the general power supply to the appliance and close the gas supply valve. 6. Do not obstruct the appliance s cooling or heat dissipation vents. 7. The appliance must be used only for the purposes for which it has been expressly designed (cooking). All other uses (such as the heating of a room) are considered inappropriate and therefore dangerous. The manufacturer declines all responsibility for damage resulting from improper use of the appliance. 8. The use of any electric appliance implies the observance of some basic rules. More specifically: - Avoid the use of extension cords and, if necessary, take all precautions; - Do not pull the power cord to disconnect the plug from the power socket; - Do not allow children or untrained persons to use the appliance. 9. Before performing maintenance work, disconnect the appliance by pulling the plug out of the power socket or turning off the main switch. 10. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. 4 Officine Gullo

SAFETY INSTRUCTIONS Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING: Improper installation, adjustment,alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. To avoid personal injury or property damage, please read and follow these important safety precautions. 1. Before any maintenance or repairs are performed, disconnect the appliance from the electric and gas supply. 2. Your appliance should be installed by a qualified gas installation technician. Have the technician show you the exact location of the gas shutoff valve on the incoming gas line so you know how to turn off the gas if necessary. 3. In the event of a power failure, do not attempt to operate the appliance or light any of the burners. This is a gas fired appliance that employs electrical components such as the ignition and safety devices. 4. Do not attempt to repair or replace any part of this appliance unless specifically instructed to do so by this manual. In-warranty service must be performed by an authorized service agency. 5. Do not store flammable materials on or near the appliance. Keep the appliance area clean and free of combustible materials, gasoline and other flammable vapors and liquids. A check before each use to determine that no hazardous materials are in the area is recommended. 6. Children should not be left alone or unattended in the kitchen while the appliance is in use. 7. This appliance should not be operated without a properly sized and operational ventilation hood. 8. The ventilation and flue ways of this appliance must remain unobstructed at all times. 9. Do not store items of interest to children above the appliance. Children, as well as adults, should never be allowed to sit, stand, or climb on any part of the appliance. Serious injury may occur. 10. Never leave the appliance unattended during use. Boil-overs may occur, causing spills which may ignite. 11. Do not use water on grease fires. Never pick up a flaming pan. It is recommended you purchase a multi-purpose dry chemical or foam- type fire extinguisher for your home. Store it in close proximity to your appliance. 12. If you are flaming liquor or other spirits, and you're appliance is installed under a vent hood, TURN THE FAN OFF. The draft created could cause the flames to spread out of control. 13. For your safety, never use your appliance or any other cooking appliance as a space heater to warm or heat the room. 14. Use only dry potholders. Moist or damp potholders on hot surfaces may result in steam burns. Do not allow potholders to touch hot burner areas. Do not use a towel or other bulky material as a potholder. 15. To reduce the risk of burns, ignition of flammable materials, and spillage, the handle of any pot or pan should be positioned so that it does not extend over adjacent burners or the front of the appliance. Officine Gullo 5

FIG.A 1. Cooking rings by-pass FIG.B FIG. F PC -GP, CF -GP (FUOCHI, FLAMME, FEUX, COOKING RINGS, FUEGOS) 2 1 3 4 562047300M00P00 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos 3. Lighting spark plug 2 Regolazione aria Luftregelung Réglage d'air Air regulation Regulación aire 3 Candela accensione Zündkerze Bougie 4. d'allumage Thermocouple Lighting spark plug Candela encendido 4 Termocoppia Thermoelement Thermocouple Thermocouple Termopar 1. Injector cooking rings 2. Air regulation 6 Officine Gullo

FIG.C COUP DE FEU 1. Injector 2. Pilot Officine Gullo 7

ELECTRICAL / SCHEME The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70. If the electrical supply is not turned on or is interrupted the appliance will not operate. The applicable wiring diagram for this appliance is below. The circuit where you wire your appliance to must be grounded and polarized. We recommend the circuit for your appliance be a non-gcfi dedicated line. FIG. D ELECTRICAL SCHEME TOP 1. Electrical connection 2. Push-button starting burner 3/4. Power-station starting burner 8 Officine Gullo

FIG.E OVEN ELECTRICAL SCHEME 549018805 M00_00 1. Commutator 2. Commutator 3. Junction-box 4. Element 5. White light 6. Green light 7. Safety thermostat 8. Thermostat 230V~ 50/60Hz 230V~3 50/60Hz Officine Gullo 9

INSTALLATION INSTRUCTIONS This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory 50012 Antella - Bagno a Ripoli (FI) Italy via della Torricella, 29, tel. +39 055 6560324 In the US call (800)-781-7125 Home page http:// www.officinegullousa.com E-Mail: info@officinegullousa.com INSTALLATION S MANUAL Keep the appliance area free and clear from combustibles. Not obstruct the flow of combustion and ventilation air, This manual shall be retained for future reference. The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales conditions. GAS PRESSURE REGULATOR (Must be installed) Each gas hook input (every element) is supplied with a separate pressure regulator that needs to be installed. For assembly proceed as follows: To screw to held the elbow to 90 (1) on the ramp of income of gas. To screw the elbow the nipples of the connexion (2). To screw the nipple to the pressure regulator (3). WARNING: Maximum input pressure is ½ PSI. The pressure regulator has to be placed under or behind the cabinetry next to the range or in a different place but never under or behind it. 10 Officine Gullo

INSTALLATION S INSTRUCTIONS GAS CONNECTIONS This appliance must be installed by an approved installer or a gas technician 1. The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the installation must conform to the latest level of the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In Canada, the installation must be in accordance with the current CAN/CGA B149.1 and B149.2. 2. This appliance can be configured to work with either natural gas or LP gas. Verify that the appliance and the incoming gas supply are compatible. Check the rating plate. 3. The gas supply line must be the same size or larger than the gas inlet of the appliance. Your appliance has ¾ NPT gas inlet connection at the factory supplied gas regulator for each gas input. We recommend the supply line be ¼ NPT larger than the gas inlet of the appliance. 4. Sealant used on pipe joints must be resistant to LP gas. 5. An installer provided manual shut-off valve must be installed in the gas supply line ahead of the appliance. This shut-off must be easily accessible in case of emergency. 6. All gas cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation. This appliance is equipped with such a gas pressure regulator. Incoming gas pressure should be checked with a manometer. The correct manifold pressure for natural gas is 5.0 wc. For LP gas the correct manifold pressure is 10 wc. 7. Incoming line pressure upstream of the appliance should be 1.0 wc greater than the operating manifold pressure. Service pressure may fluctuate for a variety of reasons. Under no circumstances should the factory supplied regulator be removed or by-passed. 8. The factory supplied pressure regulator will withstand an input pressure of ½ PSI (12 wc). If the incoming pressure exceeds the maximum rating, a step-down regulator is required. 9. The appliance and its individual shut-off valve must be disconnected from the gas supply line during any pressure testing in excess of ½ PSI [3.5 kpa]. 10. The appliance must be disconnected from the gas supply by closing its individual shut-off during any pressure testing less than ½ PSI [3.5 kpa]. 11. Check to see that all installer supplied pipes and fittings are clear of debris, threading chips or other foreign particles before connecting the appliance to the supply line. Such particles will clog orifices and/or valves when pressure is applied. Service to clean such clogs is not covered by your warranty. 12. The incoming gas supply is brought from the inlet pipe. This is the only connection required via the installer-supplied shut-off valve. 13. If the appliance is to be installed with flexible couplings and/or a quick disconnect the installer must use a commercially approved AGA Design certified flexible connector at least ½ NPT that complies with ANSI Z21.41. In Canada, the connector must comply with CAN 16.10-88 and the quick disconnect device must comply with CAN 16.19M-79 and Officine Gullo 11

installed with a strain relief device. 14. Before putting the appliance into service test all gas connections for leaks. Use a soapy solution. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. Such a procedure is dangerous, and it may not detect all the small leaks that a soapy solution will 15. Air shutter adjustments are preset at the factory. These adjustments may need to be redone and/or fine tuned by the installer. TECHNICAL GAS DATA TABLE MODEL DIMENSIONS cm GEPS12P 120x70x90h Coup de feu 23,885 BTU/h NOMINAL BURNER CAPACITY Nr. Open ring 11,942 BTU/h Nr. Open ring 18,767 BTU/h Nr. Open ring 25,591 BTU/h TOT.NOM. CAPACITY Gas BTU/h Gas coupling NPT 1 1 2 1 98,952 3/4GM The machine is supplied with pressure regulator separately (in 3/4 NPT F) TECHNICAL ELECTRICAL DATA TABLE MODEL Dimensions cm Tot kw Max. Assorb. A Power supply Power supply cable mm² GEPS12P 120x70x90h 5 21,74 110+110V 50/60 Hz 3 x 2,5 UNPACKING Cut and Remove Plastic Straps Lift off cardboard surround Lift equipment off Timber stand The machine is supplied with pressure regulator separately (in 3/4 NPT F) INSTALLATION The appliance must be installed in accordance with the ANS Z83.11a CSA 1.8a(2001) Food Service Equipment. The operations for installing, conversions for use with other types of gas and starting up must be done only by qualified personnel whose qualifications comply with the norms in force. Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas emissions which are formed during combustion. The air necessary for combustion is 70.6 CbtF /h per 3412 BTu's (2m3 /h per kw) of power installed. 12 Officine Gullo

VENTILATION Proper ventilation is highly important for good operation. This appliance must be installed under a properly designed canopy hood. We recommend that the hood should be six inches [150 mm] wider than the appliance, however, it is not a requirement. A strong exhaust fan can create a vacuum in the room. For proper air balance, work with your Offcine Gullo representative and/or contactor to properly size your hood and its exhaust fan. IMPORTANT ALL GAS BURNERS NEED SUFFICIENT AIR TO OPERATE AND LARGE OBJECTS SHOULD NOT BE PLACED IN FRONT OF THIS APPLIANCE WHICH WOULD OBSTRUCT THE AIR FLOW THROUGH THE FRONT. OBJECTS SHOULD NOT BE PLACED ON THE REAR BACKGUARD WHILE IN USE. THIS COULD OBSTRUCT THE VENTING SYSTEM OF THE OVEN S FLUE PRODUCTS. Ensure that the air outlets in the place of work are sufficient to guarantee the necessary air exchange.the appliance may be installed as a single element or in series with other appliances of our production. It is necessary to observe a minimum distance of 4" (10 cm) from the appliance to prevent contact with walls of inflammable material; adequate measures must also be taken to ensure thermal insulation of inflammable parts, such as the installation of a protection against radiation; particular attention must be paid in installing the appliances adequately and safely. The feet are adjustable in height so that differences in level can be avoided. The machine must be place in conditions of optimal ventilation: the area for the combustion of the item comes captured from the bottom of the same one. The minimal necessary area for the combustion is given from the minimal height of the feet mounted on the machine, therefore the machine cannot be installed without the adjustable feet. In case of wood cabinetry placed on the side of the range, the cabinetry has to be mounted on top of feet in order to grant a correct ventilation to the machine. PIPE FOR GAS CONNECTION The gas connection must be done with steel pipes, or otherwise with flexible steel pipes in compliance with the national norms, if any exist. Each appliance must be provided with a cut-off cock for rapid interruption of the gas supply. Once the appliance has been installed, it is necessary to check for gas leaks for the pipe fittings; do not use a flame for this purpose but a non-corrosive substance such as soapy water or foamy substances as contained in leak-finder sprays. All our appliances undergo careful testing: the type of gas, the operating pressure and the category are indicated on the data plate. Officine Gullo 13

CHECKING HEAT OUTPUT The appliances must be checked in such a way as to verify that the heat output is correct: The heat output (thermal power) is indicated on the data plate of the appliance. Firstly, check that the appliance can be used with the type of gas supplied; then check that the indication on the plate corresponds to the gas to be used. For converting to another type of gas, check that the type of gas complies with what is stated in this instruction manual. The pressure is read with a gauge inserted in the relative pressure outlet. Remove the hermetically closed screw and connect the gauge pipe. After reading, put back the screw, tightening it hermetically and check for leaks. Connection for liquid gas (Propane HD-5) The connection pressure for liquid gas is 2.74 kpa with Propane HD-5. Connection with natural gas The connection pressure for natural gas is 1.74 kpa. THIS APPLIANCE IS EQUIPPED WITH THE GAS TYPE AS PER YOUR ORDER - A conversion kit is provided with the range if it ever needs to be converted to a diferent type of gas suppy (LPG or Natural Gas) and it in a package together with the rest of the manuals. ADJUSTMENTS IN MAIN BURNERS Air shutter adjustments are preset at the factory. These adjustments may need to be redone and/or fine tuned by the installer. These adjustments are normal and can be regulated and fixed with a screw by adjusting the air shutter. In the Burners technical data table are the approximate values of parameter h (air shutter). The volume flow of primary air (air shutter) must be regulated so that the flame does not tend to come away from the burner when it is cold or backfire when the burner is hot, The flame should be almost all blue all the time. Lowest setting addjustment can be made by turning the bypass screw by a 1/4 of the turn at time, see table below for values, note that for LPG the screw position should be closed. RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS Our appliances are tested and regulated with liquid gas (see data plate). The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the various types of gas are supplied in a packet and are marked in hundredths of mm (see burners technical data table). 14 Officine Gullo

BURNERS TECHNICAL DATA TABLE & ADJUSTMENT VALUES GAS A (Natural gas) Burner Nominal Gas Consumption (BTU/h) Main Injector size Nominal/ (Measured) Values in mm Lowest setting addjustment (By-pass Screw Adjustment) (See note) Air Shutter Adjustment (Primary Aeration Adjustment) Values in mm Small 11,942 1.60 ¼ turn Fully open Medium 18,767 1.90 ¼ turn 33 Large 25,591 2.40 ¼ turn 35 Coup de Feu 23,885 1.45 ¼ turn - GAS E (Propane gas) Burner Nominal Gas Consumption (BTU/h) Main Injector size Nominal/ (Measured) Values in mm Lowest setting addjustment (By-pass Screw Adjustment) (See note) Air Shutter Adjustment (Primary Aeration Adjustment) Values in mm Small 11,942 1.00 0.20 Fully open Medium 18,767 1.15 Fully closed Fully open Large 25,591 1.45 Fully closed 20 Coup de Feu 23,885 1.45 Fully closed - GAS A = Natural gas (pressure at the outlet of the regulator) = 10 mbar (4 inch water) GAS E = Propan gas (pressure at the outlet of the regulator) = 24.9 mbar (10 inch water) Officine Gullo 15

REPLACING THE NOZZLE FOR THE BURNERS Main nozzles: Remove the grills, the burners and the containers, substitute the nozzles with the right ones, using a suitable spanner, unscrewing the blockage screw and relative jam nut. Once regulated, tighten the screw, adjust the minimum flame by turning the screw to the right or left until the thermal power reaches 3,924 BTU/h for the 11,942 BTU/h burner, 35,290 BTU/h for the 18,767 BTU/h burner and 8,530 BTU/h for the 25,591 BTU/h burner. Warning: For functioning with LPG, the screw for regulating minimum output must be blocked completely. SUBSTITUTING THE NOZZLE IN THE ALL PLATE BURNER Remove the panel and with a suitable spanner substitute the nozzle with another, suitable one. Adjust the minimum flame by turning the by-pass screw either to the right or to the left until heat output reaches 13,648 BTU/h. The primary air of the all plate burner does not need adjusting. Warning: For functioning with LPG, the screw for regulating minimum output must be blocked completely. DECLARATION OF COMPLIANCE The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly concerning room ventilation and discharging gas emissions. N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation, maintenance or use of the appliance and alterations, as in all the other cases considered in the items of our sales conditions. 16 Officine Gullo

ELECTRIC CONNECTION The appliance is supplied without the connection cable; to install it, proceed in the following way: -Remove the back panel bye removing the screws that are around its perimeter as shown in picture 1E -Fit the connection cable through the cable channel, connect the conductor wires to the corresponding terminals in the junction box as shown in picture 2E below and fix them into place. -Block the cable with the cable blocker, and reassemble the panel. The ground wire must be longer than the others so that if the cable blocker should break for any reason, it will disconnect after the hot wires. N.B. The connection cable must have the following characteristics: it must be type H05RN-F and must have an adequate section for the power of the appliance (see technical data table). The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70. There are several screws around the perimeter of the back panel, to remove the panel you need to remove all the screws around the perimeter and them pull away the panel to access the terminal block. IMPORTANT! MAKE SURE TO ALWAYS DISCONNECT THE APPLIANCE FROM THE ELECTRICITY BEFORE WORKING ON IT. Picture 1E Line 110 / 120V Line 110 / 120V L1 L2 N Picture 2E Officine Gullo 17

USE AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS FOR USE Attention! The appliance must only be used under surveillance. LIGHTING AND ADJUSTING THE BURNERS On the front panel, above each knob, there is a symbol which indicates to which burner the knob corresponds. To light, turn the knob to the left from position 0 to the symbol (see figure); keep it pushed down and press the button with the symbol until the gas lights. The knob must be kept pushed down for a few seconds and then released. The flame may go out, in which case it is necessary to repeat the procedure. By turning to the position, the burner is brought to the minimum. To put out the burner, turn the knob back into the 0 position. LIGHTING AND ADJUSTING THE COUP DE FEU On the front panel, above each knob, the burner it corresponds to is indicated by the index Use a lighter to light the pilot flame: turn the knob to the left, from the 0 position to the sign (see figure), hold it down and light the gas. Keep the knob pressed a few second and then let it go. If the flame goes out you have to repeat the procedure. By turning the knob round to the position the burner is at maximum. By turning the knob round to the position the burner is at minimum. To switch off, move the knob back into position " 0". 18 Officine Gullo

TURNING ON AND ADJUSTING THE ELECTRIC OVEN 120 210 0 570 390 480 Turn the control knob to the right and set the temperature wanted. To turn the oven off, turn the knob to the left to position 0. To turn the oven on, turn the selector knob (see figure) to the right or left into one of the following positions. 300 Top + bottom heating element Bottom heating element Top heating element Caution: when the oven is on the door must be kept shut otherwise the knobs and protection sheet could get hot and be damaged. Officine Gullo 19

VERY IMPORTANT With the use of the range the brass (burnished, nickel or chrome) plate, show in the picture, may warp due to the developed heat. After the use the bar will get it's original shape. 20 Officine Gullo

CARE AND CLEANING INSTRUCTIONS CLEANING BURNISHED BRASS SURFACES No synthetic protective varnishes have been used to obtain the special burnishing effect on the burnished brass details in order to avoid spoiling the beauty of the brass with an artificial patina. The antique finish of the surface is the result of natural oxidation that has simply been accelerated. All the natural antique finish brass surfaces can be cleaned with mild soap and warm water, accompanied by the use of an abrasive pad (the green color type used for washing dishes). It is recommended that the metal be rubbed, uniformly applying light pressure, use caution as this will remove some of the patina if rubbed excessvily. The brass details should then be dried. Do not use metal polish as this is suitable not to clean the antique finish and could result in loos of the color and patina. Oxidation that may appear over time on the burnished brass surfaces is a normal characteristic of our craft metal working processes. CLEANING CHROME PLATED BRASS SURFACES No synthetic varnishes have been used to obtain the special polish on the chromium-plated brass details in order to avoid spoiling the beauty of the chrome with an artificial patina. All the chromed surfaces should be clean as needed with a warm water and mild soap and a soft cloth or micro-fiber. Do not use abrasive pads. CLEANING SATIN FINISH NICKEL PLATED BRASS SURFACES No synthetic varnishes have been used to obtain the special nickel-plating on the satin finish nickel-plated brass details in order to avoid spoiling the beauty of the nickel-plated, satin finished solid brass with an artificial patina. All the nickelplated and satin finished brass surfaces should be cleaned, where necessary, with a soft cloth or micro-fiber cloth, combined with a mild soap, if required. Do not use abrasive pads. CLEANING THE VARNISHED SURFACES All the varnished surfaces should be cleaned using a mild soap and, where necessary, a soft cloth or micro-fiber cloth. Do not use abrasive pads or any other chemical products. Officine Gullo 21

CLEANING BRUSHED STEEL SURFACES All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be used on steel and, where necessary, extrafine steel wool. WHAT TO DO IN THE EVENT OF A BREAKDOWN Turn off the gas shut off valve and notify your authorized service center or call our main line at (800) 781-7125 22 Officine Gullo

Officine Gullo 23

us V 1.3-10.17 OFFICINE GULLO S.R.L.: via della Torricella 29, 50012 Antella - Bagno a Ripoli (FI) Tel. +39 055 6560324 / 621807 - Fax: + 39 055 620670 - info@officinegullo.com WWW.OFFICINEGULLO.COM