Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Similar documents
SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Aquamatic Instantaneous DHW production unit with integrated storage tank

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

WZH Ground source heat pumps

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

HYDRONIC RESIDENTIAL

PRODUCT GUIDE

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

LZT High efficiency air to water heat pumps with E.V.I. compressors

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Ultimate energy saving technology

PRODUCT RANGE HEAT PUMPS 2012

CRIMSON & CRIMSON MAX

Advance Split

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Galletti Water chillers and heat pumps catalogue

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

ULTIMATE ENERGY SAVING TECHNOLOGY

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Neosys Product catalogue

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Process glycol chillers

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

High temperature air-to-water heat pumps

EVI Scroll Air To Water Heat Pumps

Air cooled industrial chillers

International Markets. Product Catalogue. complementary items

HIWARM COMPACT kw

ENG CATALOGUE Italian Company Since 1956

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Do you want a versatile solution


AUDAX Air-water heat pumps reversible with inverter single and three-phase

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

HVS, Hydro Variable System Air cooled chiller

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

Air Cooled Chillers & Heat Pumps WinPACK HE-A

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

PURESTREAM CHILL-CUBE TM BY FRIULAIR

Blue Box Epsilon Echos +

Ultimate energy saving technology

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

EVI + INVERTER MODELS A Q U A P U R A

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Solar heating systems

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

kw COOLING kw HEATING

Starting current with soft starter Fuse protection. Heat source connection

Starting current with soft starter Fuse protection

Transcription:

Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar heat all year long and maintain a stable temperature. They are therefore a heat source in winter, and a cool source in summer. Geolo requires 1 kw to move this energy from the ground to the terminal units, and gives up to 5 kw of thermal energy back. This means that up to 80% energy is free, renewable and clean. Vertical geothermal exchangers Horizontal geothermal exchangers Geothermal Well COMPACT TECHNOLOGY Means constant attention to every detail, to the design and engineering of the components. In this way we are able to conceive, design and create extremely compact sized products, that allow a reduction of unnecessary dimensions. Component engineering made it possible to place inside the unit a good amount of the hydraulic components needed to complete the system. Geolo includes all the valves, pumps and safety switches needed to move the fluid in the probes and in the system. Geolo supplies sanitary hot water thanks to the integrated 3 way valve. Moreover, Geolo (model F) allows the rooms to be cooled almost for free thanks to the free-cooling device. SMART CONTROL The smart control ensures a perfect climatic wellness and sanitary hot water production all year long. Geolo works using climatic curves: the temperature of the system can be changed depending on the external climatic conditions following the climatic curves. The heating capacity can be adjusted to the building s heat load, in order to get a very high energy saving. The operation criteria take the climatic season and the thermal load into consideration, linking comfort and energy saving at their best. All functionalities can be set with an optional remote supervision kit, which allows a management with a remote contact, through the Web or GPRS.* ADAPTIVE SW The on board software allows a perfect system configuration, including the dissipation circuits, thanks to the very precise and easy user interface. The correct operation of dissipation circuits and the correct system supply are ensured. QUICK INSTALL SYSTEM On the upper part of the unit you can find 3 couples of hydraulic connections (inlet and outlet): one for the dissipation circuit, one for the system and one for the sanitary hot water production circuit. Thanks to the OS Compact Technology and the self-adapting on board control, design and installation of the unit in the system are extremely easy. 12 * Optional

FEATURES AVAILABLE IN 5 DIFFERENT SIZES: GEOLO 10 M, GEOLO 13M, GEOLO 14T, GEOLO 16 T, GEOLO 19T. GUARANTEES SANITARY HOT WATER SUPPLY WITH AN EXTERNAL BUFFER. INVERTER CIRCULATION PUMP ON THE DISSIPATION PROBES CIRCUIT (VERSION B) PROTECTION HEAT EXCHANGER KIT ON DISSIPATION WATER CIR- CUIT WITH DIFFERENTIAL PRESSURE SWITCH (VERSION WW) STANDARD FREE-COOLING DEVICE INCLUDED (VERSION F) CLIMATIC CURVES BASED ON THE OUTDOOR AIR TEMPERATURE: two curves available, one for cooling and one for heating. GUARANTEES HOT WATER UP TO 60 C 3 SET POINTS (HEATING, COOLING AND SANITARY HOT WATER) CAN BE MANAGED R410A REFRIGERANT REVERSIBLE REFRIGERANT CIRCUIT SCROLL COMPRESSOR WITH CRANKCASE HEATER STARTING CURRENT LIMITER FOR SINGLE PHASE UNITS (M) PHASES SEQUENCE CHECK FOR THE TRIPLE PHASE UNITS (T) HYDRAULIC CIRCUITS WITH SAFETY FLOW SWITCH ELECTRONIC EXPANSION VALVE EASY AND COMPLETE FRONT ACCESSIBILITY TO ALL THE COMPO- NENTS USER INTERFACE WITH EXPLICIT MESSAGES B BF W WF WW WWF Circulation pump Inverter dissipation circulation pump Freecooling module System and sanitary water temperature probes External air temperature probes o o o o o o Safety heat exchanger with differential flow switch and dissipation on-off circulation pump o o 2 way valve (application with external on off pump) o o o o 3 way valve (application with external on off pump) o o o o Web + GPRS supervision module o o o o o o GEOLO 10M GEOLO 13M GEOLO 14T GEOLO 16T GEOLO 19T B 99662 99661 99660 99659 99658 B F 99647 99646 99645 99644 99643 W 99667 99666 99665 99664 99663 W F 99652 99651 99650 99649 99648 WW 99657 99656 99655 99654 99653 WW F 99642 99641 99640 99639 99638 o = OPTIONAL = STANDARD B = dissipation in geothermal probes (closed circuit) BF = dissipation in geothermal probes (closed circuit) with freecooling system W= dissipation in water (open circuit) WF= dissipation in water (open circuit) with freecooling system WW= dissipation in water with safety exchanger (open circuit) WW= dissipation in water with protection exchanger (open circuit)and freecooling system 13

TECHNICAL DATA GEOLO 10M GEOLO 13M GEOLO 14T GEOLO 16T GEOLO 19T Heating Capacity Geolo B (A) kw 10,02 12,53 13,92 16,08 18,51 Power Input kw 2,32 2,91 3,19 3,73 4,29 COP 4,31 4,31 4,36 4,31 4,31 Heating Capacity Geolo B (B) kw 9,36 11,8 13,13 15,33 17,4 Power Input kw 2,88 3,7 3,98 4,72 5,35 COP 3,25 3,19 3,3 3,25 3,25 Heating Capacity Geolo WW ( C) kw 12,51 16,02 17,48 20,25 22,99 Power Input kw 2,41 3,14 3,16 3,86 4,50 COP 5,19 5,11 5,53 5,24 5,11 Heating Capacity Geolo WW (D) kw 11,5 14,78 16,15 18,8 21,24 Power Input kw 3,00 3,96 3,94 4,83 5,71 COP 3,83 3,73 4,10 3,89 3,72 Cooling Capacity Geolo (E) kw 12,65 16,9 18,1 21,37 24,46 Power Input kw 2,48 3,31 3,5 4,18 4,79 EER 5,11 5,11 5,17 5,11 5,11 Cooling Capacity Geolo (F) kw 9,28 12,02 13,3 15,68 17,92 Power Input kw 2,68 3,44 3,5 4,21 4,95 EER 3,46 3,49 3,80 3,72 3,62 Water flow in heating (35/30 C) l/h 1723 2155 2394 2766 3184 System pump input power kw 256 256 410 410 410 Compressor type scroll scroll scroll scroll scroll Number of compressors 1 1 1 1 1 Refrigerant gas R 410A R 410A R 410A R 410A R 410A Hydraulic connections 1"1/4 1"1/4 1"1/4 1"1/4 1"1/4 Electrical power supply V/Ph/Hz 230/1/50 230/1/50 400/3N/50 400/3N/50 400/3N/50 Compressor start up current A 97 97 66 73 75 Sound pressure level(g) db (A) 55 55 57 57 57 Operational weight kg 201 201 206 206 206 (A) = Radiant plant: Water temperature plant side (out-in): 35/30 C; Fluid temperature source side (in-out): 0/-3 C (B) = Fancoil plant: Water temperature plant side (out-in): 45/40 C; Fluid temperature source side (in-out): 0/-3 C (C) = Radiant plant: Water temperature plant side (out-in): 35/30 C; Water temperature source side (in-out): 10/5 C (D) = Fancoil plant: Water temperature plant side (out-in): 45/40 C; Water temperature source side (in-out): 10/5 C (E) = Radiant plant: Water temperature plant side (out-in): 18/23 C; Fluid temperature source side (in-out): 30/35 C (F) = Fancoil plant: Water temperature plant side (out-in): 7/12 C; Fluid temperature source side (in-out): 30/35 C (G) = Sound pressure level @1 m HYDRAULIC CONNECTIONS A - Out Dissipation B - In Dissipation C - In User System D - Out User System E - In Sanitary F - Out Sanitary Male Fillet Connections Dn - 1 1/4 14 dimension (mm)

DIAGRAMS Thermometer Pressure gauge Automatic air vent Sludge remover with drain Check valve Shutoff valve Expansion vessel Water temperature probe Air temperature probe Check valve Thermostatic mixer Suction well Return well Self-cleaning filter 2-way solenoid valve Plate exchanger* Diff. pressure switch* Thermostat Pressure gauge Automatic air vent Check valve Shutoff valve Expansion vessel Water temperature probe Air temperature probe Pressure sensor. * WW exchanger kit 15

HEAT PUMP ACCESSORIES GEOLO DHW INSTANTANEOUS HEATERS - DHW instantaneous heaters combined with inertial tanks (puffer). - Features exchanger with copper brazed plates in stainless steel INOX AISI 316 and a primary circuit circulator. Adjustment of DHW temperature is by thermostatic mixing on the primary circuit (models 01349 and 01350) or by flow modulation on the primary circuit via electronic control unit (model 01351) - Drastic reduction of legionella risk thanks to minimum stagnation of sanitary water. Compact insulated unit, easy to install and service. 01349 01350 01351 Max primary flow rate l/h 1200 1620 1650 Min operation flow rate l/min 2,5 2,5 2 Power supply V / W 230AC/93 230AC/132 230AC/90 Length (A) mm 340 400 475 Height (H) mm 400 620 835 Depth (B) mm 165 180 226 DHW production (45 C/DT 35 K)* l/min 11,5 20,7 21,8 *= Primary 50 C; DCW inlet 10 C Table A Table B F E D G C B A TABLE A TABLE B PUFFER / STORAGE TANK 01199 01200 01201 01333 01334 01335 01346 01347 01348 Water volume lt 50 100 200 300 500 800 300 500 800 - Storage tank designed to ensure correct Weight kg 25 34 45 90 120 170 115 140 200 water content in system (recommended Solar exchanger m 2 - - - - - - 1,8 1,8 2,6 min 10 l/kw) and reduce activation of Geolo A mm 300 400 450 500 650 790 500 650 790 heat pump to the minimum. B mm 933 1095 1395 235 330 340 235 330 340 - Puffer function on sanitary circuit to meet C mm 785 935 1200 420 520 530 420 520 530 DHW demand D mm 485 560 705 605 710 720 605 710 720 - Maximum operating temperature 95 C, E mm 180 185 215 835 930 1050 835 930 1050 maximum operating pressure 3 bar F mm 100 100 105 975 1090 1470 975 1090 1470 - Carbon steel tanks insulated with rigid G mm 530 605 750 1345 1470 1725 1345 1470 1725 polyurethane (100 mm thickness 50 mm H mm - - - 1565 1695 1975 1565 1695 1975 in 50/100/200 l versions) and blue Pvc finish. - Also available with fixed solar exchanger with coil ( 300/500/800 l versions) 16

B0625 ANTI-VIBRATION RUBBER SUPPORTS Anti-vibration rubber feet B0626 OUTDOOR AIR PROBE WITH BOX To be used for activation of the climate curve for setpoint compensation. B0627 TWO-WAY VALVE FOR CONDENSATION CONTROL To be used with WW/W unit (ground water dissipation) Application with external dissipation pump featuring variable flow (inverter controlled). B0628 THREE-WAY VALVE FOR CONDENSATION CONTROL To be used with WW/W unit (ground water dissipation) Application with external on-off dissipation pump. INTERMEDIATE EXCHANGER KIT FOR UNIT WW 10/13 * B0630* Intermediate protection exchanger kit for unit with ground water dissipation (WW version). The kit includes an exchanger with copper brazed plates, thermally insulated and mounted on support plate, a differential pressure switch, brass fi ttings and connectors. INTERMEDIATE EXCHANGER KIT FOR UNIT WW 14/16/19 B0631* Intermediate protection exchanger kit for unit with ground water dissipation (WW version). The kit includes an exchanger with copper brazed, thermally insulated and mounted on support plate, a differential pressure switch, brass fi ttings and connectors. B0629 ETHERNET REMOTE SUPERVISION KIT + GPRS - Module is applied on outside of unit - Enables access to the unit s control panel to interact with the machine in real time via web. - Hardware features Ethernet connection and network and USB port for quick download of data. - Gsm-Gprs internal modem version for connection with standard telephone lines. *required for WW version 17