SIMPLICITY BY DESIGN M52 CONTROLLER

Similar documents
Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series PS6, Vertical Floor-Mount Units

Mission Critical Air Conditioning Systems

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

STEAMPAK Series BurnerPAK BMS Burner Management Systems

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Liebert icom. Intelligent Communication and Monitoring. Installer/User Guide

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Odyssey. issue 01c. system manual

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Operating Functions Temperature Parameters

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Chilled Water Precision Air Conditioner for Critical Application

Oakton TEMP 9500 Advanced Multiparameter Controller

Advanced FireAlarm Panel 1-4Loop

ATC32U01 igate Communicating, Programmable Thermostat

DXM2 Digital Heat Pump Controller

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Tri-Stack Smart System

CAREL heatersteam Electric Element Steam Humidifiers

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Largo & Allegro. Air Compressors LARGO & ALLEGRO

Metasys Integrator Airflow Application

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

Rollair. Air Compressors. Rollair 15-40E

APC BC300 Series 40kW 208/450/480V User Guide

NA G µair CONNECT 2

Humidity Controller Specification and Installation Instructions. Model HRO20

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

PDA20DX Air Purifying Dehumdifier Manual

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Table of Contents. W2W Open

Control Relay Modules

ACT2-CS Convenience Store Controller

ProCon Boiler Controller Commissioning Quick Reference Guide

CLIMATIC 60 User manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Variable Frequency Drive SERIES MP800 VFD

APC APPLICATION NOTE #119

Power Flame Incorporated

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Flexible & Innovative. Cooling Solutions

The EN54 Part 2 & 4 Fire System

The EN54 Part 2, 4 and 13 Fire System

TEC210x-2 Series Networked Thermostats

Follett Performance Plus

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

ATC32U01A Communicating, Programmable Thermostat

Tranquility Digital Quick Start Guide

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

MISSION CRITICAL Air Conditioning Systems. Maintenance Guide. ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Installation and Operation Manual

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

DAP III Zone Master User s Guide

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

ZXSe Range Data Sheet

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Refrigerated air dryers

Document # R01

At Coster we manufacture a comprehensive range of pre confi gured modular controllers which are both easy to install and simple to programme by use

New Versa IC Platform

Safety & Installation Instructions

Undercounter Refrigerator Operation Manual i.series and Horizon Series

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

I/O ZONE 560/583 USERS GUIDE

Wiser Air User Interface Guide. Thermostat

Overview - Danfoss Link and living software versions

Feature Summary. I. System

N M AirControl AHU. Control manual

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

ATC32U02 igate Communicating, Programmable Thermostat

GMM Güntner Motor Management

ATC32U03 igate Communicating, Programmable Thermostat

NetworkAIR AFX. Operation and Maintenance AFX65 AFX18

OPERATION AND MAINTENANCE MANUAL. Electrode Steam Humidifier Nortec EL Series

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

ITAS / ITAS-EXT / ITLS / ITLS-EXT

ATC32U01 igate Communicating, Programmable Thermostat

Danfoss gas detection unit Type GD Heavy Duty

Complete Boiler Management in a Compact, Affordable System

Intelligent Security & Fire Ltd

SCK. Air Compressors SCK 3-40 & ALLEGRO 8-11

Transcription:

SIMPLICITY BY DESIGN M52 CONTROLLER

CO-WORK TM CONNECTIVITY Our controller is at the heart of all of ClimateWorx product intelligence. Co-Work TM is based on a unique multi-master network system designed by ClimateWorx to maximize performance, reliability and manageability of our precision air conditioning systems. Its six key control functions guarantee the highest possible degree of on-site connectivity utilizing built-in IIC communication bus. An optional remote mounted panel allows for remote monitoring and control in a LAN environment. Common alarm output can be used for automatic dial-up to an emergency service response unit for remote sites. CO-WORK TM FUNCTIONS CONTROL REDUNDANCY Co-Work TM allows multiple master units to coexist on the same network. In case any master requires service, the remaining units will automatically take over control of the whole system. In the event of a controller failure, control will be transferred automatically to the other masters minimizing loss of system control and down time. EXPANSION OF CONTROL STEPS Co-Work TM improves the system performance by utilizing the limited number of control steps in individual units and converts tem to a maximum of 8 steps. This provides more precise control and limits on/off cycles by matching capacity to load. CONTROL VALUE AVERAGING Co-Work TM exchanges sensor readings (temperature and humidity) from network units and operates from the average value. This prevents units from fighting each other when multiple units control one space. SEQUENTIAL LOAD ACTIVATION Co-Work TM coordinates the activation and deactivation of components in a unit and within a group of units to minimize in-rush current DATA SYNCHRONIZATION Unit operation data such as set points, time schedule, alarm status is synchronized among units under the same C0- Work TM network. TWO LEVELS OF DUTY SHARING The first level maintains the required number of duty units in the network and automatically sequences duty and redundant units on to even out run time. This function is time based and is factory set for 24hrs. This value is adjustable. The second level of duty sharing automatically initiates lead/lag sequence of the components among the duty units to equalize run time. Co-Work TM BMS RS485 STANDARD GATEWAY RS485/Ethernet/Lon RS485 Co-Work TM #1 Co-Work TM #2 WEB ENABLED GATEWAY Ethernet Co-Work TM Network BMS Network

OPERATING STATUS DISPLAY 3-LEVELS LOG-IN SECURITY ACKNOWLEDGE ALARM TO MUTE THE AUDIBLE WARNING ACTIVE ALARM DISPLAY CUSTOMIZE ALARM CONFIGURATION FOR 26 PRE-PROGRAMMED ALARM MESSAGES 50 HISTORICAL EVENT LOG

PROCESS STATUS & OPERATION ICONS Heating Cooling Free Cooling (3 rd bar when active) Local on/off control via control panel Programmed timer schedule auto on/off Network Address Dehumidifying Humidifying Remote on/off via switch input Standby start backup start mode Co-Work TM Address SHOWN ACTUAL SIZE POSSIBLE ALARM CONFIGURATION OPTIONS Enable option key - alarm will only be monitored if this option is selected. Unit shut down option key - if this option is selected, unit will be automatically shut down under alarm condition. Standby enable option key - if this option is selected, standby enable output will be activated under alarm condition. Common alarm option key - if this option is selected, common alarm output will be activated under alarm condition. Event log option key - if this option is selected, the alarm events will be logged in the historical event/log. Audible warning option keys - provide selection of three different audible warning sounds. TEST MODE CONFIGURATION AND MANUAL OVERRIDE CONTROL Switched input / output opened. Switched output opened under override control. Switched input / output closed. Switched output closed under override control. Analogue output in percentage. Analogue output in percentage under override control.

TIMER MODE ON/OFF SCHEDULE LATEST 24-HOUR MAIN TEMPERATURE AND HUMIDITY LOG GRAPH SETTING FOLDER DISPLAYS & PROGRAMMING UNIT CONFIGURATION, SETPOINT, CUMULATIVE OPERATING HOURS AND OTHER CONTROL PARAMETERS I/O BOARD DIAGNOSTIC FOR UNIT IN CO-WORK TM NETWORK - SCREEN 1 I/O BOARD DIAGNOSTIC FOR UNIT IN CO-WORK TM NETWORK - SCREEN 2 SENSOR CALIBRATION & REVIEW OF SUPPLY VOLTAGE IN PERCENTAGE

GUIDE SPECIFICATIONS 1.1 The unit shall have a microprocessor based control system with automatic control and monitoring capability. 1.2 The control system shall use a Proportional + Integral + Derivative (PID) control algorithm to maintain the temperature and humidity to a close tolerance of ±0.5 C and 3% RH. 1.3 The control system shall have a fascia with 240x128 dot resolution touch screen graphical CD display located on the front panel of the unit for the display and programming of functions. 1.4 The control system shall display simultaneously the following information on the fascia. Room temperature in C/ F Room humidity in %RH Network Address no. Co-Work TM Unit no. On/Off mode indicator Operating status Active alarms Date & time 1.5 System confi guration and setting shall be stored in non-volatile memory and safeguarded in the event of power failure. 1.6 The system shall have at least three levels of programmable password access to prevent unauthorized changes of the system confi guration and settings. 1.7 The control system shall have a built-in testing routine to simplify fi eld testing and troubleshooting. 1.8 The system shall be capable of communicating with a Building Management System (BMS) Network, via a RS485 serial link through a BMS Interface (Gateway / Communications Bridge) for remote monitoring function. CONTROL FEATURES 2.1 System set-points and confi guration shall be programmable only when access is gained by entering the correct password. 2.2 The following programmable control parameters shall be provided for fi ne tuning the system to suit the site conditions and requirements: Temperature set point Temperature high limit Temperature low limit Cooling proportional band Heating proportional band Temperature dead band Relax temperature dead band Temperature integral action time Humidity set point Humidity high limit Humidity low limit Humidifying proportional band Dehumidifying proportional band Humidity dead band Relax humidity dead band Humidity integral action time 2.3 The control system shall have the following programmable On/Off control mode options: Local mode allows unit on/off control via the I/O key on the display Remote mode allows unit On/Off control via a switched input Timer mode allows 4 event/day weekly automatic on/off control 2.4 A Standby unit enable input shall be provided to force the unit to start irrespective of the current On/Off status and On/Off mode setting. 2.5 For energy saving and extended system life, a Relax feature shall be provided in the Timer On/Off mode to allow wider temperature and humidity tolerances when the room is not operational. The system shall have programmable, manual, or automatic restart option. A programmable startup delay shall be provided for the automatic restart option which allows multiple units to restart progressively when power resumes after a power failure. 2.6 The accumulated runtime of the following components shall be logged for energy analysis ad planned maintenance: Fan Compressor Heaters Humidifi er 2.7 Components shall be scheduled to activate sequentially to minimize inrush current. 2.8 The system shall have a temperature and humidity graph which shows the main temperature and humidity variation in the latest 24 hours. The data for the graph shall be logged in 15 minute intervals. ALARMS 3.1 The control systems shall have the following standard alarms: High/Low temperature, 1 & 2 High/Low humidity, 1 & 2 High/Low voltage Filter dirty Fan overload Low airfl ow Compressor high pressure, 1 & 2 Compressor low pressure, 1 & 2 Heater overheat Boiler dirty Fire Flood Fault 1 (user defi ned) 3.2 All alarms shall have programmable reporting/ response options which include: Polling enable / disable Unit shutdown Activate standby unit Activate common alarm output Log alarm event 4 warning sound selection 3.3 Alarm messages, when programmed, shall comprise text description and occurrence time. Messages shall be ranked in the sequence of occurrence for fault analysis. 3.4 When a programmed alarm condition exists, the audible alarm shall sound and the common alarm output shall close until acknowledged. Active alarm record shall remain until the alarm condition is cleared. 3.5 A historical event log which maintains the latest 50 system events shall be provided. The test description and occurrence time of the following events shall be logged: Power failure Power restore Unit start Unit stop Alarm raised Alarm acknowledged Alarm cleared CO-WORK TM, MULTIPLE UNITS CONFIGURATION 4.1 The units shall have built-in master and slave inter-networking capability, Co-Work TM which allows a combination of a maximum of 8 master or slave circuits to form a local area network. 4.2 To achieve the tightest control tolerance and minimize component on/off, the units shall have a built in control step expansion algorithm which uses a multi-step control scheme to coordinate the on/off of cooling, heating, humidifying and dehumidifying steps in multiple units. 4.3 The units shall have a sequential load activation control algorithm to minimize the inrush current when components among multiple units are activated at the same time. 4.4 The control of a slave circuit shall not be limited to any particular master unit. Any master unit can control any slave. In case of a master unit failure or scheduled service, the remaining master units in the same network shall automatically take over the control. 4.5 The units shall have a duty sharing control algorithm which helps maintain the required number of duty units and balancing runtime by automatically coordinating units on/off and providing time based auto-changeover. 4.6 The units shall have a data synchronization feature. Operation data such as set points, time schedule, and alarm status shall be automatically synchronized among all the units under the same local area network. 4.7 To avoid hunting among multiple units, the units shall have a control value averaging algorithm which allows units to exchange sensor readings and control the room based on the common desired average values. Units shall be capable of displaying the network temperature and humidity or the individual unit s temperature and humidity. Mission Critical Climate Control ClimateWorx International Inc. 14 Chelsea Lane Brampton ON, L6T 3Y4, Canada Tel: (905) 405-0800 Fax: (905) 405-0807 1-800-648-2584 www.climateworxinternational.com ISO 9001:2008 All rights reserved. In the interest of continuous improvement, ClimateWorx reserves the right to change specifications without notice. All ClimateWorx equipment is evaluated and accepted by a Nationally Recognized Testing Laboratory, NRTL accredited organization to UL 1995 standard. ClimateWorx International Inc. is part of the Bempro Global Group of companies. COLE-CW-M52-B 2014.01.13