ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com
Index KEY PADS & CARD READERS Heavy Duty Keypads... 1-4 E5 Access...5,6 2
HEAVY DUTY KEYPADS ENTRYCHECK SERIES DIGITAL KEYPADS The IDC EntryCheckTM series consists of stand alone digital keypads designed to control access of a single entry point for facilities with up to 500 users. Each user is assigned a personal identification number (PIN). Keypad entry of a valid one to six digit code activates one or both of the output relays which releases an electric door lock. Optional Prox Readers are available for selective models 918 EntryCheck Vandal Resistant, Thick S. S. Faceplate 920 EntryCheck Vandal Resistant, 920P EntryCheck Vandal Resistant, with Prox Reader 923 EntryCheck VNarrow, 923P EntryCheck VNarrow, 921P & 924P EntryCheck Vandal Resistant, with Prox Reader, 2 piece Configuration 1
FEATURES Weather Resistant Heavy Cast Vandal Resistant Housing Heavy Cast Metal Blue Backlit Keys Keypad programmable 500 Users, 4-6 digit PIN codes 4 outputs, 2 relay and 2 solid state outputs timed or latching (on/off) Assign entry PIN s to relays 1 and/or 2 LED Status: Access, lockout Tactile keys with loudness selectable audible volume for key depression or output activation Timed anti-passback, anti-tailgate Keypad tamper lockout Request-to-Exit/Enter input Choice of door sense/relay inhibit input functions Forced entry Door ajar Inhibit relay 1 or 2 Auto relock when door closes Choice of 2 solid states outputs functions: Alarm shunt Forced entry Door ajar Tamper lockout Keypad active PROX Only: 3 User Modes: PIN or Card Card Only Card and PIN 923 Indoor/Outdoor Stand-Alone Narrow Keypad, Dimensions: 1.75 W x 7-5/16 H x 1-3/8 D (1.5 wall projection) 923 ENTRYCHECK SPECIFICATIONS Voltage 12/24 VAC/DC Current 30mA typical, 150mA maximum Outputs Relay 1 - SPDT 5 Amps @ 30VDC Relay 2 - SPDT 2 Amps @ 30VDC Switch to Common Outputs 3 & 4 100mA @ 30VDC Temperature -22 F to + 149 F (-30 C to + 65 C) Humidity 5% to 95% non-condensing Finish 920/920P Powder Coat Painted ACCESSORIES - ACCESS CREDENTIALS HID1326-25 HID ProxCard II, 25 cards HID1326-100 HID ProxCard II, 100 cards HID1346-10 HID ProxKey II, 10 key fobs HID1346-100 HID ProxKey II, 100 key fobs 2 923P WITH PROX READER
920 Indoor/Outdoor Stand-Alone Keypad, Dimensions: 3 W x 5-3/4 H x 1-7/16 D (1.5 wall projection) 924P Indoor/Outdoor Keypad, 2 piece Configuration: Keypad and Controller, Keypad Dimensions: 1.75 W x 7-5/16 H x 1-3/8 D (1.5 wall projection) 924P 920 921P Indoor/Outdoor Keypad, 2 piece Configuration: Keypad and Controller, Keypad Dimensions: 3 W x 5-3/4 H x 1-7/16 D (1.5 wall projection) 920P with Prox Reader 921P 3
918 Indoor Stand-Alone Keypad, Single Gang Indoor blue backlit, moisture resistant keypad Thick S.S. faceplate 3/32 (2mm) Dimensions: 3 W x 4-3/4 H x 1-1/2 D (1/4 wall projection) SPECIFICATIONS Voltage 12/24 VAC/DC Current 30mA typical, 150mA maximum Outputs Relay 1 - SPDT 5 Amps @ 30VDC Relay 2 - SPDT 2 Amps @ 30VDC Switch to Common Outputs 3 & 4 100mA @ 30VDC Temperature -20 F to + 130 F (-30 C to + 54 C) Humidity 5% to 95% non-condensing Finish 918 Brushed Stainless Steel PROGRAMMING OPTIONS The EntryCheckTM series includes a Door Sense/ Inhibit Input feature. When programmed for Door Sense, a door position switch wired into the input and detects a forced entry or door ajar condition. When programmed for Inhibit Input, a maintained switch or automatic timer wired into a the input will disable the activation of the main relay. The EntryCheckTM also has a request-to-exit input for connection to an exit switch and/or fire access key switch for fire/emergency access. When access is granted, the shunt option is activated shunting alarm contacts on the door or gate. This prevents triggering of an alarm during authorized access. 4
CHOICE OF PROX CARD, FINGER PRINT OR KEYPAD ENTRY E5 ACCESS CONTROL SYSTEM Choice of Prox Card, Fingerprint or Keypad Entry Standalone or PC Managed Network up to 99 Readers Features Features STANDALONE CONFIGURATION 12VDC POWER SUPPLY HID Compatible Proximity reader Up to 4" read range 3000 cardholders Network configuration up to 99 devices Anti-passback Access mode 6 time zones 12 month programmable holiday schedule Password Required time zone Guard Patrol Function Door prop open alarm Forced entry alarm Access mode selectable 1. Proximity card only 2. Proximity card + PIN 3. Key-in card number only Communication interface: RS232 or RS485 Can be used as stand alone device without personal computer connected Use of password is time zone programmable if card data with password access selected Two types alarm status available 1. Force entry 2. Door prop open alarm Power saver function. The LED backlight turns itself off after 3 minutes Lock relay activation time, alarm function, anti-duress and door prop open alarm are individually programmable from 1 to 255 seconds Communication baud rate can be programmed via keypad Memory Buffer 3500 transactions 1. Invalid Card. 2. Restricted time. 3. Time zone unmatched. 4. Code unmatched. E5P Local PC OR Remote PC Local PC 4C 300 ft max. 2C 500 ft max. RS232 TCP/IP RS485 to USB (For 1 PC) Electric Locking Device Output Duress or Door Prop Output Auxiliary Output Request-to-Exit Device Input Door Status Contact Input NETWORK CONFIGURATION NETWORK SWITCH RS485/TCP/IP ADAPTER (For 2 PCs) E5P READY FOR CARD 2007/02/03 09:24 E5P E5C 6005B E5PW 6005B READY FOR CARD 2007/02/03 09:24 K40W POWER SUPPLY E5C 5
OPTIONAL PROXIMITY READERS 2nd Wiegand Reader (opt) E5PW E5KPW 6005B E5P Reader/Controller OPTIONAL KEYPAD READERS Entry Reader K40W 917W E5C Controller 2nd Wiegand Reader (opt) K30W Model Card Capacity Memory Buffer E5P Reader Module Type E5P Reader Range Display Battery Capacity E5 Specifications E5P 3000 cards holders 3500 transactions HID compatible proximity reader 125KHz Card up to 4" 125 KHz Key Fob Up to 2 inches 125 KHz Based on HID ProxCard II & ProxKey II in noise free environment 16 characters x2 lines LCD backlight Timer IC and data maintained up to 2 months after power failure Keypad 12 Key (0-9, X, #) Indicator Communication Interface Case Material Dimension 2-color LED (green/red) RS485, TCP/IP ABS (UL 94V-0) 4.375" W x 6" H x 1.75" D (110 x150 x 45 mm) Weight 14 ounces (380 g) Working Voltage Power Consumption Operating Temperature Humidity Approved DC 10-15 volts 300mA Max @ 12VDC 32 F - 122 F (0 C~50 C) 5%-95% (Non condensing) IEC 529 IP34 E5DI-1 COMMUNICATION INTERFACE RS485 to USB RS485 to USB data converter for 1 PC E5DI-2 Access Credentials RS485 RS485/TCP/IP dta converter for multiple PC s, Network switch required by others HID1326-25 HID ProxCard II, 25 cards HID1326-100 HID ProxCard, 100 cards HID1346-10 HID ProxKey II, 10 key fobs HID1346-80 HID ProxCard, 80 key fobs 6
West Coast Office 4431 E. La Palma, Anaheim, CA 92807 Tel: (714) 666-0390 (800) 544-4422 Fax: (714) 666-2215 intldoorclosers.com East Coast Office 1920 Air Lane Drive, Nashville, TN 37210 Tel: (615) 885-7060 (800) 225-6737 Fax: (615) 885-0903 Copyright 2017,