Installation and Operating Instructions

Similar documents
Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B

H32 Uni- Zone Model H32

Digi-Zone. Installation and Operating Instructions. Model MDP3. Controlling Your Comfort Room By Room

Digi-Zone Model MDP3 Ver.04

Mastertrol Automatic Balancing System (MABS ) EZ Zone (EZ-2 and EZ-4) Control Panels

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

ZONE 2 MOTOR SW2 OPEN M6 M4 M2 M1 CLOSED ZONE 1 MOTOR SW1 OPEN M6 M4 M2 M1 CLOSED 24V T'FORMER 2 CB1 SYSTEM B GHC R CONTROLS INC.

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Premier 2-Zone Controller model Installer Guide

HZ432 TrueZONE. Zone Panel Professional Installation Guide

TZ-3 TotalZone Zone Control Panel

Design & Installation for. Zonex Systems. System Zone Auto Changeover. System Zone Manual Changeover

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

TZ-4 TotalZone Zone Control Panel

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

Safety & Installation Instructions

LZP-2 ZONE CONTROL PANEL

Safety & Installation Instructions

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

Installation Instructions HEAT COOL FAN POWER

TB-231 ZONE 3 DAMPER PC PO C ZONE 2 DAMPER PC PO C ZONE 1 DAMPER PC PO C 24VAC T FORMER R SYSTEM W2/E W1/B O Y G RH RC C RC/RH LINK.

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Install Guide 3M-10 ENGLISH

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

W8703A Damper Interface Module

Commercial Zoning Guide

GLAS. Installation Instructions

HEAT HEAT HEAT COOL COOL

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

FP EZ4F 4 Zone Controller

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

7-Day. Digital Thermostat. residential. & 2-cool

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

Safety & Installation Instructions

Model 1730A Compact Dehumidifier Installation Instructions

TH8320U and TH8321U Touch Screen Programmable Thermostats

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

T-32-TS Touchscreen Thermostat. Installation Manual

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Installation and Operating Instructions

SmartZone TM System Manual

TB-226 ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS200.

TECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

Installation Instructions / User s Manual NAXA00101DB Communicating Daughter Board

Model 1750A/ 1770A Dehumidifier Installation Instructions

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

Mx-MTB HVAC Controller

RCS Residential Control Systems Inc.

Smart Si Thermostat. Installation Manual

Z24 Wireless Zone Controller Professional Installation Guide

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

T7200D,E Series 2000 Commercial Microelectronic Thermostats

Model Smart Digital Humidistat

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

INSTALLATION & OPERATION MANUAL

Installation, Specification & Operation Guide HI TEMP LO TEMP SUPPLY I88. ecojay. SmartZone RESET GND HEAT PUMP GAS/ELECT RVS. VLV.

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Installation & Operation Instructions

Fresh Air Ventilation Kit

Installation Instruction

Verasys System Operation Overview Technical Bulletin

Zonex Systems Intelligent Fresh Air Ventilator Installation Instructions

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

1F98EZ-1421, Easy Install

Safety & Installation Instructions

CEPL WeatherMaker Two-Zone Installation and Start-Up Instructions

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8602C Chronotherm IV Deluxe Programmable Thermostats

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

Installation & Operation Instructions

Installation Instructions

IntelliZone2 24V Installation Manual

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

Safety, Installation, and Operation Manual

Installation, Start-Up, and Operating Instructions

Installation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) Model MPC OUTPUT LED'S OUTPUT RELAYS

For Quick Set-Up go to Page 14

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

io-fav-08 FRESH AIR VENTILATION

Commercial Thermostat Submittal Data

T8611M Deluxe Programmable Heat Pump Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

Transcription:

MASTZON ZONIN SSTM 4 Zones For use with the 24V Damper Motors Model MZS4 Installation and Operating Instructions ontrolling our omfort oom By oom

MASTZON ZONIN SSTM FATUS Purge Override Button System Mode Indicator LD Power Indicator LD Boot Button Adjustable Heating Limit Adjustable Second Stage Timer ZON ADD J11 onnection Leaving Air Sensor Terminals No Sensor Jumper Zone Terminals for Zone Damper Motors and Zone Thermostats HVA quipment Terminals 24VA Transformer Terminals e-settable Fuse Mounting Keyholes Two at Top also. Zone alling Indicators Mode DIP Switches Form 2045-0803 opyright Trolex orporation & ZoneFirst P a g e 2 6 Aspen Drive - andolph, NJ 07869 1-877-FirstZone (347-7896)

INSTALLATION The MasterZone Zoning System-4 is a four (4) zone control panel that controls up to four zones of heating and cooling. The MZS4 panel is the central control panel that all zone dampers, zone thermostats, HVA quipment, power transformer, Leaving Air Sensor and ZoneAdder panels are wired. When installing the MZS4 panel it is important to pick a central location where it is most convenient to bring all the wires. Most often this is at the furnace or air handler. It is often the most convenient location and closest to power, the HVA unit controls and the zone dampers when typically located at or near the plenum. The MZS4 panel is made of sturdy ABS plastic and can be mounted to any flat surface. It is recommended that the panel be mounted to a wall or return plenum and NOT on the furnace or plenum where it will be in contact with the hot temperatures.. The panel can be located in an attic space or in an enclosed cabinet of a rooftop unit, in order for the panel to be in direct exposure to the elements. The cover easily removes from the case by pulling firmly and separating the cover from the case exposing the circuit board. There are 4 key-hole mounting points in each corner of the case. The case has openings in the rear of the case as well as the side for all wiring. Wiring can come from the back as well as the side in order to make a neat installation. OPATION The MZS4 can control various types of HVA quipment all from the same panel. The MZS4 features allow the use of single stage thermostats to control up to three stage heating and two stage cooling and simple heat pump thermostats to control heat pumps. The MZS4 has various features that make installation and checkout very simple for all of the board s functionality. The MZS4 s basic function is zone control. On a call for heating or cooling, the panel will accept the first call from any zone. Upon accepting this call the MZS4 will open the damper(s) to the zone(s) calling, close the damper(s) to those zones not calling, activate the needed HVA controls for heating or cooling, whichever is being called and not accept any calls for the opposite mode. Any calls for the opposite mode will be locked out until the initial mode is either satisfied or a period of time has elapsed that is sufficient for the first mode to satisfy, a maximum of 20 minutes, when both calls occur simultaneously. An exclusive sequence determines the time the unit has been running or needs to continue to run in order to adequately provide conditioning for each mode. If a particular mode has already been calling for 20 minutes or longer and an opposite call comes in the MZS4 will immediately drop the mode, enter the purge mode in order to dissipate the conditioned air into the zones calling before switching over to provide the new conditioning call to its zones. When using the MZS4 to control multi-stage heating and/or cooling, the extra stages are controlled based upon time after the first stage call from the thermostat. When any zone calls the panel s built-in timer begins and after the set period of time elapses the MZS4 will also activate the W2 for Heating or 2 for ooling. In heating, after the second stage is activated the same timer will control the third stage of heating. The Stage Timer is adjustable from 5 to 23 minutes after the first stage call. Once the extra stages are on, these stages will continue to run until the first stage is satisfied or the Leaving Air Sensor limit setting is reached. (See Leaving Air section for further information.) Once all zone thermostats are satisfied for heating and cooling, the MZS4 will accept Fan calls allowing ontinuous Air irculation(a) in those zones where the thermostat s Fan Switch is set to ON. These zone dampers will be Open while the dampers to the zones where the Fan Switch is set to AUTO will be LOSD. When all zone thermostats are satisfied for both Heating and ooling, and all Fan switches are set to AUTO position, the HVA unit will be off and all zone dampers will return to a normally open position. Once a zone calls for heating, cooling or fan, the dampers to the calling zones remain open and the dampers to the zones not calling will close. Set-Up for Various HVA quipment The MZS4 is factory set for conventional fossil fuel (oil or gas) single and up to three stage heating and two stage cooling. The panel only needs to be configured when using with an conventional electric furnace or hydro-air system in order to bring the fan on with a call for heat, or when using with a heat pump equipment and thermostats. Most all of the panel configuration is done by setting the DIP switches in the lower center of the panel. Below is show their setting and functions. ON OFF 1 2 3 4 5 6 7 8 1. HP QP Heat Pump quipment This switch changes the output of the HVA quipment terminals from conventional Heating and ooling to a traditional Heat Pump Output. When OFF, a heat call activates the W1 output and the second stage activates W2. When ON a Heat call activates the 1 output to bring on the compressor for first stage and 2 for the second stage, of both heating and cooling. W3 is activated on a third stage call in either mode. 2. FAN HAT Activates the output to turn the Fan on with a call for Heat. This is used for Heat Pumps, lectric Heat furnaces and Hydro-Air Systems. In the OFF position the MZS4 will not activate the Fan in heating unless there is a fan call from one of the zone thermostats. 3. O TO W Switch Is placed to ON when using Heat Pump thermostats that use an O terminal to activate the reversing valve in OOLIN. The O on the thermostat is wired to W on the zone terminal in order to determine if the call is for heating or cooling. All zone thermostats must operate and be wired the same way. 4. B TO W Switch is used when using Heat Pump thermostats that use a B terminal to activate the reversing valve in HATIN. The B terminal on the thermostat is wired to W on the zone terminal in order to determine if the call is for heating or cooling. All zone thermostats must operate and be wired the same way. NOT: Some OMs use the B terminal as a transformer ommon and not as the heating reversing valve. These thermostats will use the O terminal for the reversing valve and should be wired accordingly using DIP Switch #3. The B terminal will then be wired to the terminal on the thermostat terminal block. 5. FAN P This switch keeps the fan running during the purge time in order to dissipate the conditioned air into the last zone(s) calling. Placing this switch to ON, prevents the fan from turning off from the fan control in the HVA Unit during the purge mode and coming back on moments later if another call is waiting. In OFF the fan will be control by HVA Fan controls. This is desirable in residential to prevent cold drafts after heating by having the switch OFF. 6. M HAT MN HAT This switch can be used to place all zones into the mergency Heat mode. This switch would be used when single stage thermostats are used. NOT: There is no indication on the panel to show this switch is ON. 7. ZON ST STA ONTOL This switch is used to control how the second stage of heating and cooling is determined. In the OFF position, the second stage is controlled by the timer. In the ON position the second stage is brought based on the number of zones calling. reater than 50% of the zones calling will bring on the second stage, for both heating and cooling. 8. TL 3 Future Use One of the many features of the DIP switches is if at anytime the equipment is changed from single stage to heat pump or vice versa the thermostats do not need to be changed with the equipment change. hanging the DIP switch settings is all that is needed. Form 2045-0803 opyright Trolex orporation & ZoneFirst P a g e 3 6 Aspen Drive - andolph, NJ 07869 1-877-FirstZone (347-7896)

Leaving Air Temperature Sensor The Leaving Air Temperature Sensor, Model ZPS, is a remote sensor that is located in the supply air duct to sense the leaving air temperature of the HVA Unit. The ZPS is a high limit protection for the heating and a low limit protection for the cooling. When zoning, the airflow through the HVA Unit is critical. The ZPS protects the equipment in low air flow situations as well as when by-pass air is being directed back into the return air duct. The heating limit is adjustable from 100 F to 170 F. The cooling limit is fixed at 40 F. When the ZPS senses heating above its set point, or cooling below its set point, the MZS4 will drop both stages of heating or cooling. The ZPS must sense a 10 F fall for heating or rise for cooling before re-activating the first stages of heating or cooling. If two stage heating or cooling is being used the second stage timer will start again once the first stage is re-activated. After all calls are satisfied or the changeover timer activates, the Purge Timer begins and the heating or cooling, whichever was on, is deactivated. Typically the fan may be running during this time and the damper(s) to the last zone(s) calling will remain open to purge the conditioned air only into those zones that were calling for the conditioning. DIP Switch 5 can be set ON to keep the Fan running during the Purge mode in order to prevent the fan cycling off and back on between modes. In the instance where the Fan staying may create a draft, and the frequency of opposite calls is minimal this switch can be kept to OFF. The L P button on the top left of the panel can be pushed to override the Purge mode and speed installation and checkout. This button is only active when the System LD is AMB. L P The ZPS requires 2 wires from the sensor to the LAT1 and LAT2 terminals on the MZS4 panel. The ZPS probe can also be adjusted for length by loosening the end nut and sliding the probe thru the mounting plate in order for the probe to pass through any duct insulation Leaving Air Sensor (Mounted in Supply Air before Zone Dampers) Model ZPS LAS Terminals On Zone Panel NOT: If the ZPS is not used, the NO SNSO jumper located near the LAT terminals must placed across the two pins. When the sensor is used the jumper must be removed from the pins. Stage Timer The MZS4 has a built-in stage timer that eliminates the need and added cost of using two stage thermostats. On a call for either heating or cooling the timer begins. A minimum of 5 minutes, adjustable to a maximum of 23 minutes, can be set in order to activate the W2, W3 and 2 outputs after the first stage call. The Stage Timer is marked 0 through 9 and each increment is indented as the dial is rotated. A minimum 5 minutes is set when the dial is set to 0. To calculate the stage timing the dial setting is multiplied by 2 and added to the base of 5 minutes. xample: Dial setting is 3 x 2 = 6 + 5 = 11 Minutes for the Stage Timer. ST Time 5 MIN + 2X When any zone calls the timer starts and activates the second stage W2 or 2 after the set time elapses. The timer also controls W3 after the same time elapses after the W2 call. PU TIM The MZS4 has a built-in Purge Time after each call is satisfied and provides a minimum off time before another call is initiated. The Purge Time is set at 2.5 minutes after all calls for a particular mode are satisfied or when the hangeover Timer requires a changeover due to opposing calls. Minimum On Timer The MZS4 also has a minimum on time whenever the compressor operates in order to prevent frequent short cycling. Once there is a call for cooling or the compressor on a heat pump, the MZS4 will hold that call for a period of 2 minutes. HANOV TIM Whenever a call is made for either heating or cooling, the changeover timer is activated in order to track the amount of time heating or cooling is on. When an opposite call is made after a first call is existing the changeover timer calculates the amount of time the unit has already been supplying the first mode in order to determine how long it will hold off the opposite call. If an opposite call is made shortly after the first call, the opposite call may be held off for as much as 20 minutes. If the first call or subsequent calls for the first call mode has had that mode operating for up to 20 minutes already and an opposite call comes in after 20 minutes, the changeover timer will immediately recognize the opposite call, shutting off the current mode, enter the purge mode and automatically switch to the opposite mode. The longer a call has been running up to 20 minutes, the shorter the wait time will be for an opposite call. If a call is over 20 minutes and an opposite call is made the changeover will be immediate following the purge time. This intelligent changeover timing makes the MZS4 unique to any other zoning system. Zone-Adder ontrol The MZS4 Zone Panel can be added onto with the MasterZone-Adder Model MZA. The MZA is available as a 2 zone adder panel and expands any MZS4 panel up to 10 zones, using a maximum of three (3) MZA panels. The MZA2 panel is connected by a 6 conductor J11 telephone cable. This makes wiring between the MZS4 and MZA2 literally a snap. This cable is included with each MZA panel. HKOUT The MZS4 has unique features that simplify the checkout of the system and has LD readouts that constantly indicate the system operation. Once 24 Volt Power is applied to the panel the reen Power LD will illuminate. This will stay illuminated constantly when power is applied. The System LD will provide several different indications based upon color and if it is flashing. Heat ON D Heat Limit D Flashing ool ON - N ool Limit - N Flashing FAN ON/PU - AMB TIM DLA AMB Flashing ach zone has its own small reen indicator LD next to each zone relay. This light is lit when the specific zoning is calling for the mode shown on the System LD. Form 2045-0803 opyright Trolex orporation & ZoneFirst P a g e 4 6 Aspen Drive - andolph, NJ 07869 1-877-FirstZone (347-7896)

WIIN The MZS4 is very simple to wire and requires only a minimum number of connections. The MZS4 terminal blocks are screw-less and all wires can easily be pushed into their respective terminal by de-pressing the button for each point and releasing once the wire is seated. To remove the wire, just press its button again and remove the wire. WIIN DIAAM 1 Single Stage Thermostat SINL STA THMOSTAT W MZS4 ZON ONNTIONS W/OB LOS OPN OM THMOSTAT DAMP MOTO WIIN DIAAM 2 Single Stage, Two Stage and Three Stage Heating quipment and up to Two Stage ooling QUIPMNT W3 W2 W1 B O 1 2 HATIN OOLIN QUIPMNT Third Stage Heat elay Second Stage Heat elay First Stage Heat elay 24V. Transformer Fan elay First Stage ooling elay Second Stage ooling elay WIIN DIAAM 3 Heat Pump Thermostats HAT PUMP THMOSTAT O/B MZS4 ZON ONNTIONS LOS OPN OM THMOSTAT DAMP MOTO WIIN DIAAM 4 Typical Heat Pump quipment QUIPMNT W3 W2 W1 B O 1 2 AI TO AI HAT PUMP ONNTIONS HAT PUMP ONTOLS mergency Heat elay 24V. Transformer Fan elay eversing Valve ompressor elay Second Stage Heat elay TOUBLSHOOTIN The MZS4 is a very simple control to troubleshoot, especially with the LD indicators. The only other device needed is a simple Volt/Ohm meter. Almost all problems can be traded to an external component or wiring to the MZS4. While the MZS4 has been designed to operate under extreme voltage conditions and is fuse protected, like any computer the micro-processor can hang up and not operate properly. For these instances a BOOT button has been installed that re-boots the micro-processor just like your computer. Pressing this button for a few seconds and then release it will allow the micro-processor to re-boot and in most all cases eliminate the problem. If not the following procedure can help isolate the problem. BOOT Zone(s) Not alling ach zone has a reen LD next to the zone relay when it is calling and that calling is being recognized by the MZS4. If a zone is supposed to be calling and the Zone LD is not on, check for 24VA across the thermostat terminal and the, if a ool call, W if a Heat all, or if a Fan call. If there is no voltage here at the panel the panel is not getting the signal from the thermostat. The problem is mis-wiring, a broken wire or a problem in the thermostat. To check the zone on the panel, place jumper from to, to W or to to see that the panel is operating properly. Zone(s) Will Not Shut Off If a zone will not stop calling, the Zone LD should still be on. Depending on the call disconnect the, W or wire from the terminal strip. The zone will drop out. heck the thermostat wiring for a miswiring or short that keeps the zone calling. Damper Motor heckout ach zone has reen indicaor light located to the right of the zone damper s relay. When all zones are satisfied all zone lights are lit reen indicating all zone dampers will be Open. To check this there will be 24VA across the OM and Open terminal. When any zone calls, the damper(s) to the satisfied zone(s) will power close and the indicator light will go out. When the damper is to be closed there will be 24VA across OM and LOS. 6 Aspen Drive andolph, New Jersey 07869 USA Telephone 1.877.604.1044(US and anada) FAX 1.201.794.1359 www.zonefirst.com info@zonefirst.com Form 2045-0803 opyright Trolex orporation & ZoneFirst P a g e 5 6 Aspen Drive - andolph, NJ 07869 1-877-FirstZone (347-7896)

MZS4 WIIN DIAAM SINL STA THMOSTAT W ZON ONNTIONS LOS OPN OM 34 5 6 7 2 8 1 0 9 135F 100F 170F Leaving Air Sensor (Mounted in Supply Air before Zone Dampers) Model ZPS SINL STA THMOSTAT W ZON ONNTIONS LOS OPN OM LAS Terminals On Zone Panel HATIN OOLIN QUIPMNT SINL STA THMOSTAT W ZON ONNTIONS LOS OPN OM QUIPMNT W3 W2 W1 B O 1 2 Third Stage Heat elay Second Stage Heat elay First Stage Heat elay 24V. Transformer Fan elay First Stage ooling elay Second Stage ooling elay SINL STA THMOSTAT ON W ZON ONNTIONS LOS OPN OM 8 7 6 5 4 3 2 1 HP QP FAN HT O TO W B TO W FAN P M HAT ZON ST TL 3 24VA 24VA Form 2045-0803 opyright Trolex orporation & ZoneFirst P a g e 6 6 Aspen Drive - andolph, NJ 07869 1-877-FirstZone (347-7896)