JOB SITE ADDRESS: PERMIT NUMBER: 08-1691 VALUE: 1,878,708 380 W 37TH ST WATER DATE: 04/22/09 QUEBECOR WORLD Co. Parcel # 95024-32-002 287 LTD ADDN 1ST REP BLK TR LOT B1 Application Type: ADDITION INDUSTRIAL BLDG ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT Addition to existing industrial building totaling 19866sf to be used for Quebecor World warehouse. No new baths, 225amp electrical service, existing water service, no A/C. Warehouse addition using pre-engineered metal building 19,866sf. Site work with paving and landscape. No sewer or water services involved per contractor. 2006 IBC, 2008 NEC review. AD STORAGE-MOD HAZARD II-B # OF BATHS NONE # OF STORIES 1.00 BUILDING PLAN 7 SETS RCVD VALUATION OF ELEC WORK 92,700.00 ELEC SERVICE SIZE 225 AMP FOUNDATION PLAN 4 SETS RCVD GRADING PLAN 11 SETS TYPE OF HEAT FANG OCCUPANT LOAD 40.00 VALUATION OF MECH WORK 50,420.00 VALUATION OF PLMB WORK 11,452.00 SITE PLAN 4 SETS SPECIAL AGREEMENT 10 DAY EXPEDITE SQ FT OF ADDITION 19,866.00 CURRENT USE VACANT PROPOSED USE WAREHOUSE VOUCHER NO WATER SERVICE SIZE EXISTING DPC Development DSP BUILDERS, INC (303)289-0666 7000 E Belleview 4475 E 74TH AVE, SUITE 201 ENGLEWOOD CO 80111 COMMERCE CITY CO 80022
JOB SITE ADDRESS: PERMIT NUMBER: 08-1692 VALUE: 100 210 BARBERRY PL DATE: 04/13/09 CES INDUSTRIAL, LLC Co. Parcel # 95261-05-004 ROCKY MOUNTAIN PLAZA 1ST ADDN BLK 01 LOT 004 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH No work permit for change in occupancy group from B-2 to proposed F-1. Contractor notes are as follows: Requests for Certificate of Occupancy for change of use within existing building built 1984 of Type V-N construction for a B-2 occupancy. Building jas 2 levels- main level is 15,520 sf and 2nd level is 1,060sf for a total of 16,580sf. The building is divided in half by a permitted 2 hour area seperation wall. CES has purchased the building for immediate occupancy for for thier assembly business to be classified as F-1 occupancy. Owner requests deferral of complance upgrades but will submit for tenant finish review and permit within 12 months of occupancy. 2006 IBC, 2008 NEC review. AD FACTORY & IND -MOD HAZARD TYPE 5 NON-RATED BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK.00 OCCUPANT LOAD 41.00 VALUATION OF MECH WORK.00 VALUATION OF PLMB WORK.00 SPECIAL AGREEMENT 5 DAY EXPEDITE SQ FT OF TENANT FINISH.00 PROPOSED USE WAREHOUSE VOUCHER NO 1ST FLR FINISHED AREA.00 CES Enterprises, LLC 210 Barberry Pl LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-85 VALUE: 65,000 5285 MCWHINNEY BLVD #140 DATE: 04/30/09 ROCKY MOUNTAIN RADIOLOGY Co. Parcel # 85094-14-001 MCWHINNEY 12TH SUBD BLK 01 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 1961 sf expansion of existing medical office/imaging for Rocky Mountain Radiology. 1-1/2 bath, 1200 amp electrical service, existing A/C. Energy Code Compliance: COM CHECK 2006 IBC/2008 NEC. T/S: 01/27/2009 08:26 AM POTOCM ---- BUSINESS V-B # OF BATHS 1-1/2 BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 11,000.00 ELEC SERVICE SIZE 1200 AMPS TYPE OF HEAT FANG/ELEC/A/C OCCUPANT LOAD 40.00 VALUATION OF MECH WORK 10,000.00 VALUATION OF PLMB WORK 8,000.00 SPECIAL AGREEMENT 5 DAY EXPEDITE SQ FT OF TENANT FINISH 1,961.00 PROPOSED USE MEDICAL OFFICE VOUCHER NO FSB PARTNERS I, LLC RHINOTRAX CONSTRUCTION INC (303)682-9906 2725 ROCKY MOUNTAIN AVE #200 4161 MULLIGAN ST LOVELAND CO 80538 LONGMONT CO 80504
JOB SITE ADDRESS: PERMIT NUMBER: 09-115 VALUE: 703,991 6125 SKY POND DR #200 DATE: 04/30/09 KENNEDY & COE Co. Parcel # 643S -01-001 MILLENNIUM EAST 5TH SUBD BLK 01 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 14,249 sf tenant finish for Kennedy & Coe. 200 amp electrical service, no bathrooms, existing water meter, existing heat and A/C. Energy Code Compliance: Com Check; 2006 IBC/2008 NEC. MP Contractor revised mechanical subcontract and total valuations. See email dated 3/27/09. AD BUSINESS V-B # OF BATHS EXISTING BUILDING PLAN 2 SETS RCVD VALUATION OF ELEC WORK 32,765.00 ELEC SERVICE SIZE 200 AMPS TYPE OF HEAT FANG A/C EXIST OCCUPANT LOAD 212.00 VALUATION OF MECH WORK 8,000.00 VALUATION OF PLMB WORK 7,800.00 SPECIAL AGREEMENT NO SQ FT OF TENANT FINISH 15,206.00 PROPOSED USE OFFICE VOUCHER NO KENNEDY & COE DOHN CONSTRUCTION, INC (970)490-1855 1901 56TH AVE 2642 MIDPOINT DR, UNIT A GREELEY CO 80634 FORT COLLINS CO 80525
JOB SITE ADDRESS: PERMIT NUMBER: 09-212 VALUE: 33,460 288-246 E 29TH ST DATE: 04/16/09 CALVARY CHAPEL #276 & 284 Co. Parcel # 95122-39-002 ORCHARDS 9TH SUBD BLK 01 LOT 002 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 4361 sf tenant finish to include 3387 sf for church and 974 sf for office space. Existing 3-1/2 accessible bathrooms,gas heat, 200 amp electrical service, and A/C. MP Per contractor there is no structural work and minimal electrical, mechanical and plumbing work. Received tax exempt certificate #98-19437-0000. MP Changed structure to 3B construction type rather than 5B construction type. Per Kenny Wiseman. AD Demolition of 5 interior non-bearing walls (only go to the sub-ceiling) is being added to this tenant finish. Valuations have been adjusted to include this work. SEF ASSY,CHURCHES III-B # OF BATHS 3-1/2 EXISTING BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 3,969.00 ELEC SERVICE SIZE 200 AMPS EXIST TYPE OF HEAT GAS EXISTING OCCUPANT LOAD 303.00 VALUATION OF MECH WORK 1,200.00 VALUATION OF PLMB WORK 2,000.00 SPECIAL AGREEMENT BO OVERRIDE SQ FT OF TENANT FINISH 4,361.00 PROPOSED USE CHURCH/OFFICE VOUCHER NO TWENTY-NINTH STREET PLAZA NAB CONSTRUCTION (970)663-1573 ASSOCIATES INC 3919 HAMMANS CT DENVER CO 80203 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-226 VALUE: 13,985 994 E EISENHOWER BLVD DATE: 04/09/09 DISCOUNT TIRE Co. Parcel # 560E -01-002 SHOPKO 2ND SUBD BLK 01 LOT 002 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM ALL STATE FIRE PROTECTION (303)288-3901 6045 E 76TH AVE #12 COMMERCE CITY CO 80022
JOB SITE ADDRESS: PERMIT NUMBER: 09-230 VALUE: 25,397 2175 E 11TH ST DATE: 04/22/09 MET SHOP RESTAURANT Co. Parcel # 506B -02-002 KOLDEWAY IND 2ND SUBD BLK 02 LOT 002 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 1160sf tenant finish for unknown tenant. 2 existing baths, 600 amp electrical service, gas heat with A/C. 2006 IBC, 2008 NEC review. This project has only 1 set of plans for 3 tenant finishes. AD BUSINESS V-B # OF BATHS 2-OTHER EXISTIN BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 4,000.00 ELEC SERVICE SIZE 600 AMP TYPE OF HEAT FANG A/C OCCUPANT LOAD.00 VALUATION OF MECH WORK 3,000.00 VALUATION OF PLMB WORK 4,000.00 SPECIAL AGREEMENT NO SQ FT OF TENANT FINISH 1,160.00 PROPOSED USE RESTAURANT VOUCHER NO Flores, Porfizio A+ FN ASSOCIATES (303)751-4016 1350 E Eisenhower Blvd 3001 S JAMAICA CT #100 LOVELAND CO 80537 AURORA CO 80014
JOB SITE ADDRESS: PERMIT NUMBER: 09-231 VALUE: 62,179 2179 E 11TH ST DATE: 04/22/09 MET SHOP GROCERY/BAKERY Co. Parcel # 506B -02-002 KOLDEWAY IND 2ND SUBD BLK 02 LOT 002 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 2840 tenant finish for Met Shop Grocery /Bakery area for unknown tenant. 2 existing baths, 600 amp electrical service, gas heat with A/C. 2006 IBC, 2008 NEC review. AD BUSINESS V-B # OF BATHS 2 OTHER EXIST BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 4,000.00 ELEC SERVICE SIZE 600 AMP TYPE OF HEAT FANG A/C OCCUPANT LOAD.00 VALUATION OF MECH WORK 3,000.00 VALUATION OF PLMB WORK 4,000.00 SPECIAL AGREEMENT NO SQ FT OF TENANT FINISH 2,840.00 PROPOSED USE GROCERY/BAKERY VOUCHER NO Flores, Porfirio A+ FN ASSOCIATES (303)751-4016 3001 S JAMAICA CT #100 UNKNOWN.. AURORA CO 80014
JOB SITE ADDRESS: PERMIT NUMBER: 09-233 VALUE: 26,273 2187 E 11TH ST DATE: 04/22/09 MET SHOP LIQUOR STORE Co. Parcel # 506B -02-002 KOLDEWAY IND 2ND SUBD BLK 02 LOT 002 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 1200sf tenant finish for Liquor Store with unknown tenant. 2 existing baths, 600 amp electrical service, 1" water meter, gas heat and A/C. 2008 NEC, 2006 IBC review. AD BUSINESS V-B # OF BATHS 2 EXIST OTHER BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 4,000.00 TYPE OF HEAT FANG A/C OCCUPANT LOAD.00 VALUATION OF MECH WORK 3,000.00 VALUATION OF PLMB WORK 4,000.00 SPECIAL AGREEMENT NO SQ FT OF TENANT FINISH 1,200.00 PROPOSED USE LIQUOR STORE VOUCHER NO.00 Flores, Porfizio A+ FN ASSOCIATES (303)751-4016 1350 E Eisenhower Blvd 3001 S JAMAICA CT #100 LOVELAND CO 80537 AURORA CO 80014
JOB SITE ADDRESS: PERMIT NUMBER: 09-239 VALUE: 165,000 2500 ROCKY MOUNTAIN AVE MCR DATE: 04/24/09 VERIZON WIRELESS EQUIP. S Co. Parcel # 663B -01-001 TWIN PEAKS 2ND SUBD BLK 01 LOT 001 Application Type: NEW STRUCTURE OTHER THAN A BUILDING ELECTRICAL PERMIT MECHANICAL PERMIT New 283sf building for Verizon Wireless Equipment Shelter on top of existing hospital building. Electric heat, Energy Code Compliance: ComCheck Software V3.5.1, with A/C. Clients notes: Site improvements for a telephone cell site for Verizon Wireless, known as FTC Chapungu. All work includes: Constructing equipment shelter, running all required power and coaxail cable from the new equipment shelter to the antennas mounted on existing and new screen panels. 2006 IBC, 2008 NEC review. AD BUSINESS I-B # OF STORIES 1.00 BUILDING PLAN 7 SETS RCVD VALUATION OF ELEC WORK 12,000.00 ELEC METER LOCATION NOT PROVIDED ELEC SERVICE SIZE 277 AMPS TYPE OF HEAT ELEC A/C VALUATION OF MECH WORK 15,000.00 VALUATION OF PLMB WORK.00 SPECIAL AGREEMENT NO CURRENT USE NONE PROPOSED USE CELLULAR COMM F VOUCHER NO WATER SERVICE SIZE NONE.00 MOUNTAIN WIRELESS CONSTRUC (303)343-6544 927 SALIDA WAY AURORA CO 80011
JOB SITE ADDRESS: PERMIT NUMBER: 09-262 VALUE: 104,843 5297 GULF STREAM CT DATE: 04/09/09 OFFICE/MEZZANINE (HANGAR) Co. Parcel # 540A -01-001 BARNSTORM 2ND ADDN AMENDED BLK 01 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 965 sf mezzanine, 845 sf unfinished with 120 sf finished office; 900 sf tenant finish on 1st floor; 1 accessible 3/4 bath, existing electrical and new A/C, (FCWSD). 2006 IBC/2008 NEC T/S: 03/12/2009 07:40 AM POTOCM ---- Per TPH this project is due out 3/19/09, called all reviewers. Changed Street CEF fee to $2694.70 per email from Rich Becker. Email was placed in address folder. AD Per TPH, these revisions are being given an expedited 5-day review. BUSINESS V-B # OF BATHS 1-3/4 ACCESSIBL BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 8,100.00 ELEC SERVICE SIZE EXISTING TYPE OF HEAT FANG NEW A/C VALUATION OF MECH WORK 8,400.00 VALUATION OF PLMB WORK 3,200.00 SPECIAL AGREEMENT NO SQ FT OF TENANT FINISH 1,020.00 PROPOSED USE OFFICE/STORAGE VOUCHER NO 1ST FLR FINISHED AREA 900.00 2ND FLR FINISHED AREA 120.00.00 BELMONT HERITAGE LLC STAR-KETT CONSTRUCTION, IN (970)227-2574 DELTA THREE ROYALTIES, INC 820 DELCON FORT COLLINS CO 80525 LOVELAND CO 80538
JOB SITE ADDRESS: PERMIT NUMBER: 09-269 VALUE: 14,360 6125 SKY POND DR DATE: 04/15/09 SKYPOND OFFICE BLDG Co. Parcel # 643S -01-001 MILLENNIUM EAST 5TH SUBD BLK 01 LOT 001 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM FRONT RANGE FIRE PROTECTIO (970)663-3310 4007 S LINCOLN AVE, SUITE 460 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-321 VALUE: 32,840 5971 SKY POND DR #C100 DATE: 04/03/09 DOGS Co. Parcel # 643K -01-001 MILLENNIUM EAST 2ND SUBD BLK 01 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT MECHANICAL PERMIT PLUMBING PERMIT 1496 sf tenant finish in former Chapangu Gallery space. 1/2 bath (non accessible), 200 amp electrical service, existing water and electrical meters, Energy Code Compliance: COM CHECK, existing A/C. This permit has been given an expedited review of 5 working days per TPH. MP MERCANTILE II-A # OF BATHS 1-1/2 BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 3,525.00 ELEC SERVICE SIZE 200 AMPS EXIST TYPE OF HEAT FANG A/C EXIST OCCUPANT LOAD.00 VALUATION OF MECH WORK 1,962.00 VALUATION OF PLMB WORK 3,525.00 SPECIAL AGREEMENT 5 DAY REVIEW SQ FT OF TENANT FINISH 1,496.00 PROPOSED USE RETAIL VOUCHER NO DIGIALLONARDO, CHRISTINE & COE CONSTRUCTION, INC (970)663-7636 VIRGINIA 2302 E 13TH ST FORT COLLINS CO 80526 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-329 VALUE: 15,000 1805 TOPAZ DR DATE: 04/01/09 ABRA AUTO BODY & GLASS Co. Parcel # 85182-17-008 SYLMAR 6TH SUBD BLK 01 LOT 002 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT Demo 2 interior walls; build 3 new walls, sheetrock and paint. Install new floor cover. 2006 IBC / 2008 NEC review. AD BUSINESS II-B # OF BATHS INFO NOT PROVID BUILDING PLAN EMAILED 1 SET VALUATION OF ELEC WORK 1,500.00 ELEC SERVICE SIZE INFO NOT PROVID TYPE OF HEAT INFO NOT PROVID OCCUPANT LOAD 10.00 VALUATION OF MECH WORK.00 VALUATION OF PLMB WORK.00 SPECIAL AGREEMENT 5 DAY REVIEW PROPOSED USE AUTO BODY SHOP VOUCHER NO.00 BOWMAN, ROBERT G VARLEY CONSTRUCTION CO, IN (507)334-6034 STEPHANIE J 16800 SHIELDSVILLE BLVD LOVELAND CO 80537 FARIBAULT MN 55021
JOB SITE ADDRESS: PERMIT NUMBER: 09-332 VALUE: 2,480 1292 S CLEVELAND AVE DATE: 04/23/09 GULF EAGLE SUPPLY Co. Parcel # 95243-12-002 S LVLD IND PARK ADDN REP L7B1 BLK 01 LOT 07B Application Type: COMMERCIAL FIRE ALARM SYSTEM INSTALL FIRE ALARM SYSTEM SHENK, DAVID K/LORETTA TRI TECH SECURITY (970)686-6596 PO BOX 464 561 GARDEN DR, UNIT G LONGMONT CO 80501 WINDSOR CO 80550
JOB SITE ADDRESS: PERMIT NUMBER: 09-340 VALUE: 5,400 3755 PRECISION DR #180 DATE: 04/09/09 AVA SOLAR Co. Parcel # 542A -01-003 MYERS GRP PRTSHP 949 1ST SUBD BLK 01 LOT 003 Application Type: COMMERCIAL FIRE ALARM SYSTEM INSTALL FIRE ALARM SYSTEM GREGORY ELECTRIC, INC (970)669-7609 3317 N LINCOLN AVE LOVELAND CO 80538
JOB SITE ADDRESS: PERMIT NUMBER: 09-343 VALUE: 38,555 710 14TH ST SW DATE: 04/08/09 DBM TECHNOLOGIES, INC Co. Parcel # 95262-25-001 LOMA VISTA 1ST ADDN BLK 01 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH ELECTRICAL PERMIT Received 2 copies MSDS. MP BUSINESS V-B # OF BATHS 4-1/2 EXISTING BUILDING PLAN 8 SETS RCVD VALUATION OF ELEC WORK 3,925.00 ELEC SERVICE SIZE 400 AMPS EXIST TYPE OF HEAT FANG EXISTING OCCUPANT LOAD 146.00 VALUATION OF MECH WORK.00 VALUATION OF PLMB WORK.00 SPECIAL AGREEMENT TPH APD REVIEW SQ FT OF TENANT FINISH 636.00 PROPOSED USE OFFICES VOUCHER NO MACDONALD, DOREEN & ALISTAIR STARWOOD C/M, INC (970)490-1813 2045 SITKA CT 452 S LINK LN LOVELAND CO 80538 FORT COLLINS CO 80524
JOB SITE ADDRESS: PERMIT NUMBER: 09-345 VALUE: 7,450 5740 BOEING DR DATE: 04/15/09 STANDARD PROCESSING Co. Parcel # 86273-06-011 EAST LOVELAND IND ADDN BLK 02 LOT 011 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM B & R REAL ESTATE FLOW FIRE PROTECTION (970)494-1817 5717 BYRD DR 3054 LAKE CANAL CT, UNIT 100 LOVELAND CO 80538 FORT COLLINS CO 80524
JOB SITE ADDRESS: PERMIT NUMBER: 09-346 VALUE: 438 1112 N MONROE AVE DATE: 04/09/09 CUSTOM WHOLESALE FLOORING Co. Parcel # 95131-98-001 LOVELAND IND 3RD SUBD BLK 01 LOT 001 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM FRONT RANGE FIRE PROTECTIO (970)663-3310 4007 S LINCOLN AVE, SUITE 460 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-363 VALUE: 1,800 801 N CLEVELAND AVE DATE: 04/06/09 TRINITY METHODIST CHURCH Co. Parcel # 95133-06-901 LOVELAND ADDN BLK 02 LOT 001 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH Replace flat roof with pitched shingled roof using 6.4 squares. Tax exempt: 98-02416. This property is located in the downtown district and is subject to a voucher. T/S: 03/31/2009 11:13 AM POTOCM ---- UNKNOWN UNKNOWN BUILDING PLAN 4 SETS RCVD SPECIAL AGREEMENT NO VOUCHER YES.00 TRINITY UNITED METHODIST KEIRNS CONSTRUCTION (DAVE) (970)667-0770 CHURCH 816 E 57TH ST LOVELAND CO 80537000LOVELAND CO 80538
JOB SITE ADDRESS: PERMIT NUMBER: 09-377 VALUE: 17,200 1811 W 15TH ST SCHOL DATE: 04/23/09 EARLY CHILDHOOD Co. Parcel # 95104-41-901 HILE 1ST ADDN BLK TR LOT 1 Application Type: COMMERCIAL FIRE ALARM SYSTEM INSTALL FIRE ALARM SYSTEM THOMPSON R2J SCHOOL DISTRICT FAS SYSTEMS GROUP LLC (303)298-7900 2890 N MONROE AVE 4800 W 60TH AVE, #200 LOVELAND CO 80537 ARVADA CO 80003
JOB SITE ADDRESS: PERMIT NUMBER: 09-390 VALUE: 800 5740 BOEING DR DATE: 04/15/09 STANDARD PROCESS WEST Co. Parcel # 86273-06-011 EAST LOVELAND IND ADDN BLK 02 LOT 011 Application Type: COMMERCIAL FIRE ALARM SYSTEM INSTALL FIRE ALARM SYSTEM B & R REAL ESTATE LIFE SAFETY TECHNOLOGIES (970)493-3206 5717 BYRD DR 912 SMITHFIELD DR, UNIT 3 LOVELAND CO 80538 FORT COLLINS CO 80524
JOB SITE ADDRESS: PERMIT NUMBER: 09-392 VALUE: 300 541 N LINCOLN AVE DATE: 04/15/09 LOVELAND MUSEUM DOOR Co. Parcel # 95133-23-001 LOVELAND ADDN BLK 12 LOT 001*008 Application Type: ALTERATION COMMERCIAL BLDG-TENANT FINISH New 4 x 7 opening in non load bearing wall at bank building owned by City of Loveland for expansion of the Loveland Museum. Tax Exempt: 98-03478 This building is located in the downtown development district and is subject to a voucher. Per Dave Sprague, only Building Division will review this permit. T/S: 04/08/2009 02:55 PM POTOCM ---- UNKNOWN UNKNOWN BUILDING PLAN 2006 IBC VALUATION OF ELEC WORK.00 VALUATION OF MECH WORK.00 VALUATION OF PLMB WORK.00 USE CODE-IND COMMISSON.00 SPECIAL AGREEMENT 5 DAY REVIEW VOUCHER YES/TAX EXEMPT.00 HALSEY CONSTRUCTION (970)667-2720 330 N MADISON AVE LOVELAND CO 80537 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-399 VALUE: 678 5971 SKY POND DR #C100 DATE: 04/15/09 DOGS/LOVELAND Co. Parcel # 643K -01-001 MILLENNIUM EAST 2ND SUBD BLK 01 LOT 001 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM FRONT RANGE FIRE PROTECTIO (970)663-3310 4007 S LINCOLN AVE, SUITE 460 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-417 VALUE: 1,280 215 CARINA CIR BLG DATE: 04/23/09 STONECREEK Co. Parcel # 85173-18-010 MILLENNIUM SW 2ND SUBD BLK TR LOT J Application Type: COMMERCIAL FIRE ALARM SYSTEM INSTALL FIRE ALARM SYSTEM FIRE GUARD (402)592-1999 4404 S 76TH CIRCLE OMAHA NE 68127
JOB SITE ADDRESS: PERMIT NUMBER: 09-460 VALUE: 558 710 14TH ST SW DATE: 04/23/09 DBM TECHNOLOGY Co. Parcel # 95262-25-001 LOMA VISTA 1ST ADDN BLK 01 LOT 001 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM GRANITE PROPERTIES INC FRONT RANGE FIRE PROTECTIO (970)663-3310 2045 SITKA CT 4007 S LINCOLN AVE, SUITE 460 LOVELAND CO 80538 LOVELAND CO 80537
JOB SITE ADDRESS: PERMIT NUMBER: 09-461 VALUE: 250 506 W 66TH ST DATE: 04/23/09 ATLAS ROOFING Co. Parcel # 96261-05-005 LONGVIEW-MIDWAY 4TH ADDN BLK 01 LOT 005 Application Type: COMMERCIAL WET FIRE SPRINKLER SYSTEM INSTALL WET SPRINKLER SYSTEM FIRST LONGVIEW, LTD FLOW FIRE PROTECTION (970)494-1817 1134 S BROADWAY 3054 LAKE CANAL CT, UNIT 100 DENVER CO 80210 FORT COLLINS CO 80524
JOB SITE ADDRESS: PERMIT NUMBER: 09-484 VALUE: 3,650 625 14TH ST SE BLG10 DATE: 04/28/09 THERM TECH TEMP OFFICE TR Co. Parcel # 95243-65-002 WATERFORD PLACE 2ND SUBD AMD BLK TR LOT B Application Type: TEMPORARY STRUCTURES:PUBLIC & INTERIM ELECTRICAL PERMIT New temporary structure for Therm/Tech office. 680sf trailer with no baths will have electric heat pulled from building and have an A/C unit. Per Rob Carlson this structure will be up for an estimated 2 months while construction on the building in being completed. Client notes: Hook up temp office trailer to existing building, power to be used by building tenant until new office space is completed. 2006 IBC 2008 NEC review. AD UNKNOWN UNKNOWN # OF BATHS NONE # OF STORIES 1.00 BUILDING PLAN 2 SETS RCVD VALUATION OF ELEC WORK 2,000.00 ELEC SERVICE SIZE N/A TYPE OF HEAT ELECT A/C SPCN OCCUPANT LOAD.00 VALUATION OF MECH WORK.00 MIXED OCCUPANT LOADNOT PROVIDED VALUATION OF PLMB WORK.00 SITE PLAN 2 SETS RCVD SPECIAL AGREEMENT NO TOTAL SQ FOOTAGE OF BLDG 680.00 TIME PERIOD.00 CURRENT USE NONE PROPOSED USE OFFICE VOUCHER NO WATER SERVICE SIZE NONE Benner, Jeryl CARLSON HOMES (970)663-7207 3053 Nature Run PO BOX 194 LOVELAND CO 80537 LOVELAND CO 80539
JOB SITE ADDRESS: PERMIT NUMBER: 09-498 VALUE: 6,500 1292 S CLEVELAND AVE DATE: 04/30/09 Co. Parcel # 95243-12-002 S LVLD IND PARK ADDN REP L7B1 BLK 01 LOT 07B Application Type: DEMOLISH COMMERCIAL/NON-RESIDENTIAL STRUCTURE DEMOLITION PERMIT Demolition of interior only to include 4 office spaces and no bathrooms. SEF GULF EAGLE SUPPLY CASTLE CREEK BUILDERS, LLC (970)278-0394 1292 S. CLEVELAND 696 W 1ST ST LOVELAND CO 80537 LOVELAND CO 80537