TOOLS AND INSTRUMENTS

Similar documents
TOOLS AND INSTRUMENTS

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

INFICON Service Tools A Catalog For Service Professionals

TEK-Mate. Refrigerant Leak Detector

Instruments. for hydroponics & horticulture 2016

MicroRay IR-100 NEW. Inspection MicroRay IR-100

AIR CONDITIONNING 95 CODE 002

Digital, not analog: One manifold for all refrigeration systems.

COMBUSTION, ENVIRONMENTAL ANALYZERS, INDOOR AIR QUALITY, LEAK DETECTION, AIR ACONDITIONED & REFRIGERATION, CARBON MONOXIDE AND COMBUSTION ANALYSIS

Using the Model 1500 Portable Chilled Mirror Hygrometer

portable gas analyser

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

TEK-Mate. Refrigerant Leak Detector

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

REFRIGERANT LEAK DETECTOR

LEADERS IN LIQUID SCIENCE.

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

LD-5000 REFRIGERANT LEAK DETECTOR

NGD8800 USER S MANUAL

onlinecomponents.com

portable gas analyser

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

RLD-H10P Refrigerant Leak Detector

H-10PM. Refrigerant Leak Detector

GAS-Mate. Combustible Gas Leak Detector

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

FIRST CHOICE CATERING SPARES LTD DIGITAL TECHNOLOGY APRIL 2015 FS

Inc Series Digital Gas Detector/Controller. Operation Manual

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Measurement Solutions for Refrigeration Technology.

CLI Refrigerant Gas Leak Detector. User s Guide

IMR IX176 Portable Gas Detector User Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Measurement Solutions for Refrigeration Technology.

OPERATION & MAINTENANCE MANUAL RHS680

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Using the DewTrak II Dew Point/ Humidity Transmitter

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds.

Refrigerant Leak Detector

RLD-H10G Refrigerant Leak Detectors

D-TEK Select. Refrigerant Leak Detector

SAM-MAX Refrigerant Monitors

Section 2. Air Conditioning & Cooling System Service Equipment. Section 2: Suppliers: CALL:

Safe Operation Manual. Honeywell IQ Force Gas Detector

Vaccine & Pharmacy Upright Glass Door Refrigerators

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Upright Chromatography Refrigerators

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Combustible Gas Leak Detector Instruction Manual

OPERATION & MAINTENANCE MANUAL AC860

Instruction Manual MSI Sensit HXG

3.4 Humidity. Types of instruments

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Tune-Rite Software Operation Manual

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

Refrigerant Leak Detection Solutions

Danfoss gas detection units

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

GAS ANALYSIS / DETECTION Gas Detector

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

EVac II Programmable Digital Vacuum Gauge

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Dräger X-am 7000 Multi-Gas Detection

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

and Refrigerant Identifier

Version Inc Series Digital Gas Detector/Controller. Operation Manual

incubator, the best in its class

Operate the Mutli-Gas Monitor PID

Forehead Thermometer Instruction Manual

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

IRT2 Dual Laser IR Thermometer - User Guide

ppm F psi ΔP C "H 2 NO x Testo An overview

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

ALTAIR 5X Multigas Detector Product Specification

GasAlertMicroClip X3 Specifications

hvgrometers Humidity Meters humidity meters hygrometers & therma-hygrometers what is a hygrometer? applications

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OPERATION & MAINTENANCE MANUAL TX600

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Digital Salt / TDS Meter. 390a. The Value Leader TM

BITUMINOUS DIGITRAC AUTO STABILITY PRESS MARSHALL AUTOMATIC DIGITAL TESTER MARSHALL TESTING MACHINE W/ RECORDER MODELS

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

INSTRUCTION MANUAL. Model: 8918 THERMO HYGRO-ANEMOMETER KNT BF FPM MPH MS CKMH

Transcription:

ACID/MOISTURE TEST KITS TOOLS AND INSTRUMENTS THE FIRST & ONLY NO-OIL ACID/MOISTURE TEST P49 TOTALTEST TEST TUBE Chemical crystals react with acid or moisture which may be present in system. THE TOTALTEST KIT INCLUDES: One Totaltest Instrument, Two Totaltest Test Tubes and a Totaltest Kit case. STD. PACK OF 6 KITS: TT1-001 REPLACEMENT TEST TUBE PACK INCLUDES: 5TESTTUBES Totaltest is the fast, easy and reliable way to test a refrigeration or air conditioning system for corrosive acid and acid-causing moisture. Because Totaltest is a self- contained test instrument which needs only a small sample of the gas in a system, you will never need to extract another oil sample again. In just 10 minutes you will know if there is corrosive acid or moisture present in the system. TOTALTEST WorksAsEasyAs1-2-3 1. Insert a test tube in the instrument. 2. Attach the TOTALTEST instrument to the unit. 3. In ten minutes, detach the TOTALTEST instrument, remove the disposable test tube and compare it to the chart on the package. TOTALTEST reads acid and moisture in 1 test. TOTALTEST checks the whole system. TOTALTEST doesn t need an oil sample TOTALTEST tests R-22, R-12, R-500, R-502, and R-11 vapor. TOTALTEST doesn t require a system shut-down. ttlsts TOTALTEST works in 10 minutes or less. Use TOTALTEST to help prevent a premature refrigeration or air conditioning system breakdown. Use TOTALTEST to check a system after a compressor replacement. Use TOTALTEST as part of a maintenance contract, before you take on a new customer and as part of the agreement. WARNING: This product contains a chemical known to the state of California to cause cancer. P50 STD. PACK OF 6 REPLACEMENT TEST TUBE PACKS TT2-001 REPAIR KIT INCLUDES: PLASTIC HOLDER FOR INSTRUMENT, WASHER STD. PACK OF 6 REPAIR KIT TT3-001 642

755TOTALTEST HFC (Yellow Tubes) MOISTURE TEST TOTALTEST INSTRUCTIONS HOW TO USE TOTALTEST FOR HFC REFRIGERANTS: Totaltest for HFC Refrigerants is currently approved for use with R410A only. PREPARATION FOR SAMPLING: 1. Allow unit to run at least 30 minutes. 2. Locate the low-side vapor service port on the air conditioning or heat pump unit. 3. Connect manifold gauges to system service valves. 4. Measure and record the vapor pressure of the system. Ensure that the system pressure is between 80 and 140 psig. 5. Backset service valve and remove vapor hose. 6. Attach Totaltest instrument to unit s vapor service port. 7. With unit still running: slightly open service valve to blow away residual oil or moisture from the Totaltest instrument. CAUTION: Liquid refrigerant or oil will distrort test results. 8. Proceed immediately with the next five steps under Measurement Procedure. MEASUREMENT PROCEDURE: 9. Remove test tube from pack. Note the direction of the arrow on the tube. 10. Break off tips of the test tubes, using one end of the pack with small hole provided for this purpose. IMPORTANT: Break off the tip with the G mark first. TUBE PERFORMANCE GUIDELINES CALIBRATION SCALE/TESTING TIMEs Use the following scales for the following refrigerants and suction pressures: Puron TM (R-410A) Test time: cooling time 90 sec Test time: heating mode TBD 1 80 psig 2 110 psig 3 140 psig INTERPRETATION OF RESULTS AND CORRECTIVE ACTION Stain length before line - Acceptable moisture. No action required. Stain length past time - Unacceptable moisture. Action required. Follow clean-up procedure A detailed inside the lid of the Totaltest2 case. NOTE: Chemical bed will turn from gold or yellow color to green stain. P1529 11. Immediately insert the tube securely against the O-ring in the tube holder, making sure that the arrow is pointing in the direction of flow. Start timing once tube is in place. 12. Place protective plastic shield over the tube and lock into place. P1530 13. At the end of recommended test time (see Tube Performance Guidelines section below), remove shield and tube from the holder. Seal the end of the tubes with the test tube caps. Wait 30 seconds before reading stain length to ensure proper reading. 14. Backseat service valve and detach tube holder from the unit. NOTE: Chemical bed will turn yellow color to green stain. P1531 If the length of the stain is in the area of the chart, then ACTION IS REQUIRED. If the length of the stain is the area of the chart, then NO ACTION IS REQUIRED. If the length of the stain is in the area of the chart, then PROCEED WITH CAUTION. PART NO. DESCRIPTION All-in-One Kit. (One Totaltest instrument, 2 Totaltest TT1-002 blue tubes, 2 Totaltest yellow tubes, Kit case) TT2-002 Standard pack of 6 replacement test tubes (yellow) 643

FLUID ANALYSIS Totaline s Fluid Analysis Service is a cost-effective method of assessing the condition of internal fluids used in all types of HVAC & R equipment and system applications. Sample Kits include the supplies needed to sample, store and ship the fluids to the lab for analysis. PART NO. DESCRIPTION AVAILABLE OPTIONS P915-0001 Lithium Bromide Analysis Kit: Uninhibited Nitrate Inhibited Chromate Inhibited Molybdate Inhibited Aresenite Inhibited Refrigerant Water Octyl Alcohol Ammonia Arsenite Molybdate & Nitrate Purge Gas P915-0002 Lithium Chloride Analysis Kit: Chromate Inhibited Molybdate Inhibited GCMS test for volatile organic contaminants Molybdate only Chromate only Dissolved Fe Dissolved Cu Total Condition Analysis BrineServe Energy Analysis P915-0003 Brine Analysis Kit (Glycol) Freeze Pt & Concentration Only P915-0004 Fluid Loop Inventory Kit Glycol Fluid Analysis Glycol Fluid & Energy Analysis P915-0005 Inorganic Brine Analysis P915-0006 Cooling Tower Water Analysis Ammonia Other Elements P915-0007 Standard Oil Analysis Kit Chlorides/Fluorides IonActivity Viscosity Mixed Oil Percentage P915-0009 Refrigerant Analysis Kit includes DOT-approved sample cylinder, shipping and labeling instructions. Other refrigerant contamination Non-condensables Standard Service 5-7 days turnaround Oil, li br, refrigerant, water & glycol samples RUSH Service 24-48 hours turnaround Oil, li br, refrigerant, water & glycol samples TOTALINE POCKET THERMOMETER ANALOG, ROUND HEAD AND DIGITAL THERMOMETERS 5 STAINLESS STEEL STEM UNBREAKABLE LENS READOUT HIGH VISIBILITY POINTER AND NUMBERS RECALIBRATEABLE POCKET SHEATH WITH SAFETY CUP +1% DIVISION ACCURACY P836 SWIVEL HEAD DIGITAL THERMOMETER 1-3/4 INCH ANALOG THERMOMETER P833 1 INCH ANALOG THERMOMETER P834 TYPE DESCRIPTION PACKAGING STD.PACK P/N 1 Round face, -40 to 180 F Temperature Range Blister pack 12 P906-1002 ANALOG, 1 Round face, -40 to 70 C Temperature Range Blister pack 12 P906-2002 ROUND HEAD 1 Round face, 0 to 220 F Temperature Range Blister pack 12 P906-1004 1-3/4 Round face, 0 to 220 F & 0 to 100 C Temperature Range Blister pack 12 P906-1006 DIGITAL Swivel head, -40 to 100 C Temperature Range Blister pack 12 P906-2009 644

MANNIX INSTRUMENTS DELUXE DIGITAL POCKET THERMOMETER DIGITAL ANEMOMETER F/C Switch Protective Cover Auto Power Off ON/OFF Switch Data Hold Simultaneous Display of Air Velocity and Temperature Recording Min., Max., and Average Measuring Average Air Velocity for Multi-points Pocket Clip C and F Switchable Drop Resistant Water Resistant P955 Hold Auto Power Off P952 2.5 Probe HDT303K RS232 Serial Output DCFM8901 Range: -40 to 300 F -40 to 150 C Battery: (1) LR44 Included AIRFLOW RANGE RESOLUTION ACCURACY 80-4900 ft/min. 1 ±2% 0.9-55.9 mph 0.1 ±2% 0.4-25 m/sec. 0.1 ±2% 1.4-90 km/hr. 0.1 ±2% TEMPERATURE -10 C to 50 C 0.1 ±0.6 C +14 F to 122 F 0.1 ±0.6 C SCREW DRIVER/TESTER with RED GLOW LED Self-Test Function AC Voltage Test: Contact: 70 to 250 VAC Non-Contact: 70 to 600 VAC Continuity Test Polarity Test Microwave Oven Leakage Detector Fuse Continuity Check Locates a Broken Wire P954 ST600LED DIGITAL SLING PSYCHROMETER Much More Accurate Than Outdated Analog Technology No Water Necessary No Twirling No Reading Charts Saves Time and Labor Instrument Displays: Temperature Humidity P953 Wet Bulb Dew Point SAM990DW 645

MANNIX INSTRUMENTS (cont) TEMPERATURE/HUMIDITY PEN (THERMO-HYGROMETER) Color: Dark Grey Power Supply: One Button Cell Included (1 CR2032) Humidity Range: 5 to 95 RH Accuracy: 10 to 90 RH ±3% All Other Ranges ±5% Temperature: ±14 Fto122 F -10 Cto50 C Response Time: 80 Seconds Typical Simultaneous Display of Temperature and Humidity Memory (Min/Max) F/C Switch Pocket Sized DIGITAL HIGH TEMPERATURE THERMOMETER F/C Switch Clear Button Min/Max Function Plastic Sheath -14 Fto392 F (0 Cto200 C) P1201 P1200 PTH8708 DPT392F/C CFM AIRFLOW METER Can read up to 8 multi-point readings Hard carrying case Single hand airflow measurement with recessed service grip F and C Switchable Auto power off RS232 output SPECIFICATIONS Air Flow 80 to 6900 ft/m (0.4 to 35 m/sec) Resolution 0.1 Accuracy ±3%, ±2 F (±1 C) Temperature +14 to 122 F (-10 to 50 C) bpic1 DCFM8906 646

BACHARACH SLING PSYCHROMETER TOOLS AND INSTRUMENTS Sling-type psychrometer determines percent relative humidity Built-in side rule calculator correlates wet and dry bulb temperatures to relative humidity Dual range (high and low temperature) scales for better resolution Thermometers telescope into handle for protection when not in use Built-in water reservoir holds sufficient water for several hours of testing P/N DESCRIPTION SCALE BAC-12-7011 Mercury Filled ( F) BAC-12-7012 Red Spirit Filled ( F) BAC-12-7013 Mercury Filled ( C) BAC-12-7043 Red Spirit Filled ( C) P825 BACHARACH GAS BURNER COMBUSTION TESTING KIT BAC-10-5217 This kit is one of the most economical means of testing for gas burner efficiency during installation or servicing. Included in this kit: Gas Service Calculator Fire Efficiency Finder High Efficiency Finder Carrying Case Moisture Absorb. Material Fyrite CO 2, 20% Filled Tyrite 0 2, 21% Filled Tempoint Thermometer 1000 F (6 Stem) Draftrite +.10 to.14 W Manometer 15 W8.5oz/in2 Sampling Tube Attachment Spare Tube Tips (6) Monoxor Indicator.2% Carton of 12 CO Tubes P4295 BACHARACH GAS PRESSURE MANOMETER BAC-17-7002 This accurate and portable manometer is easy to read. Whether you are measuring or adjusting the pressure in gas lines, the valuable manometer can be used for all types of gas burning appliances. Besides using this instrument to measure and adjust the inlet and manifold pressure, it can also be used to determine filter resistance, fan efficiency, air velocity and statistic pressures. P4296 BACHARACH OIL BURNER COMBUSTION KIT BAC-10-5022 Like the Gas Burner Combustion Kit featured above, this kit is one of the most economical means of testing for oil burner efficiency during installation and servicing. Included in this kit: Fire Efficiency Finder Carrying Case (large) Moisture Absorb. Material Sampling Hose Assembly Fyrite CO 2 20% Filled Tempoint Therm. 1000 (6 Stem) MZF Draft, +.05 to -.25 W P4294 True Spot Smoke Tester 647

BACHARACH MONOXER II CO ANALYZER WITH CASE BAC-19-8004 The continuous sampling instrument measures CO levels in combustion gas stack and ambient air levels quickly and accurately. Measures and displays low levels of CO between 0 and 2200 ppm (parts per million) in increments of 1 ppm Easy to hold with the multi-purpose strap Easy to read highly visible digital display with backlight Comes with probe and hose assembly for flu gas testing BACHARACH TRUE SPOT SMOKE TEST KIT BAC-21-7006 The True Spot smoke method has long been recognized as the accepted standard for oil burner smoke tests. The kit determines efficient combustion. The smoke test is an indispensable part of any oil burner service job as excess smoke is one of the most common causes of excessive fuel usage and expensive service requirements. P4298 P4297 BACHARACH FYRITE PRO 120 COMBUSTION ANALYZER WITCO BAC-24-8104 Increase your overall service productivity with the Fyrite Pro. Verify and adjust the efficiency of residential furnaces and appliances quickly and easily with the Fyrite Pro and all of these features: Simple to use. Turn unit on, select fuel, insert probe Each test can be recorded using an optional infrared printer (no wires) Hold key freezes the readings and transfers them to the infrared printer Tactile feedback from the instrument s keypad assures that the appropriate key has been activated Warranty offers worry free operation of instrument and sensors for up to two years after purchase A unique hand strap offers ease of handling Four alkaline batteries typically offer 24 hours of continuous operation Automatic power off ensure long battery life Optional protective rubber boot with magnet provides hands free operation Error message informs you of an instrument or sensor failure CE Certified P4293 648

LEYBOLD INFICON D-TEK REFRIGERANT LEAK DETECTOR Equal sensitivity to CFC s, HCFC s, HFC s Flexible probe Variable-intensity audible signal Electrochemical heated-diode sensor TOOLS AND INSTRUMENTS 703-006-G1 (110V) 703-006-G2 (220V) P1198 TEK-MATE REFRIGERANT LEAK DETECTOR Sensitive to CFC s, HCFC s, HFC s (.4 oz./yr.) Automatic contamination adjustment Variable-intensity contamination alarm Operating Temperature Range: -20 F to 122 F, -27 Cto50 C 705-202-G1 P1199 WEY-TEK REFRIGERANT CHANGING SCALE Precision designed Lightweight Transfer all refrigerant by weight Measures in lbs. or kgs. High accuracy load cell won t drift 707-600-G1 649

LEYBOLD INFICON (cont) GAS-MATE GASLEAK DETECTOR Sensitive to 5 ppm methane Also Detects natural gas, propane, butane, cyclopentane, ethane, ethanol, isobutane and ammonia Flexible probe Adjustable sensitivity Variable audio alarm for leak strength Auto zeroing for ignoring background gas levels TOOLS AND INSTRUMENTS 706-600-G1 CHARGING MODULE Charge/hold key Displays target charge & total refrigerant transferred Provides power to the scale 709-700-G1 YOKOGAWA H10G REFRIGERANT LEAK DETECTOR Detect all CFC, HFC and HFC Refrigerants Manual balance/zero adjust control AC powered Switchable sensitivity 25 years of proven experience Alarm Sensitivity SW Position R-134a R-12 Small 0.5 oz/yr. 0.1 oz/yr. Medium 1.0 oz/yr. 0.5 oz/yr. Large 5.0 oz/yr. 3.o oz.yr. P4282 H10G01 (120 V) H10PM REFRIGERANT LEAK DETECTOR Detect all CFC, HFC and HFC Refrigerants Manual or automatic auto zero balance control Unique sensor calibration system CE Mark Pinpoints both small and large leaks Alarm Sensitivity SW Position R-134a R-12 Small 0.5 oz/yr. 0.1 oz/yr. Medium 1.0 oz/yr. 0.5 oz/yr. Large 5.0 oz/yr. 3.o oz.yr. P4283 H10PM-5 650