Air-Handling System Cooling Options

Similar documents
Air-Handling System Cooling Options

Technical Development Program

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

CTI Sponsored Educational Program

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Heat pump and energy recovery systems

COOLING / HEATING COILS

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Air-Cooling Evaporators

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

General Catalogue. FORM SSI - G.C (94)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

THE ULTIMATE ROOFTOP SOLUTION

WCD-1. Evaporative Cooling Modules. WCD Series. Alton. Keeps You. Cool

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

LARGE CAPACITY HEATERS

Flexible & Innovative. Cooling Solutions

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

VariCool VAV Engineering Guide

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

VertiCool Aurora Engineering Guide

Modular Supply Make-Up Air Unit

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Pthey are comfortable. In regions with hot

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Direct Gas-Fired Make-Up Air Models DG and DGX

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL SPECIFICATIONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

TOPAZ ADIABATIC COOLER

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

AHRI Certification Program Scopes - COOLING

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Direct and indirect evaporative cooling

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Comfort and health-indoor air quality

Energy Recovery with Cooling and Heating

CONDENSERS AND CONDENSING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Modular Active. Chilled. Beams

Explanation of Cooling and Air Conditioning Terminology for IT Professionals

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

Implementation of Energy Saving measures in Existing Buildings

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Innovent s. Custom Pool Dehumidification Units. Your best choice for swimmers, spectators and savvy building owners.

Evaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study

InRow Direct Expansion

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

2003 METAL FORM MFG. FORM NO: PCIOM/03

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Chilled Water system

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

PACKAGED ENVIRONMENTAL UNIT

HCU Systems for Industrial Applications. Rob Smith National Accounts Manager March 7, 2011

EVAPORATIVE AIR-COOLING EQUIPMENT

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Energy Recovery with Cooling and Heating Model ERCH

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Liquid desiccant dehumidification systems. Product guide

RT-OA TM Rooftop Outdoor-Air (DOAS)

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

MAC-120HE-03 Air-Cooled Chiller

FOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A

Transcription:

Air-Handling System Cooling Options High-Capacity, Economical Evaporative Cooling High-Efficiency, DX & CW Mechanical Cooling Pure and Simple Solutions

AbsolutAire Air-Handling System Cooling Options Economical and effective cooling is easily added to your choice of AbsolutAire direct-fired heating, ventilating and make-up air systems. The cooling option selected can also be stand alone or coupled with steam, electric or hot-water heating systems. Evaporative and mechanical cooling options are available. These cooling choices are low-cost, efficient answers for temperature and/or humidity control, increased worker comfort and improved indoor air quality. Based on your facility requirements, we can help if cooling only is needed or if adding or subtracting humidity is desired as well. We can develop an engineered solution based on the entering air and leaving dry bulb (db) and wet bulb (wb) objectives, along with elevation above sea level. Evaporative cooling works by adding moisture to the air stream. These systems can be a viable low-cost option for summertime cooling and wintertime humidification in many areas. AbsolutAire has evaporative cooling with water recirculation (EVR) and without water recirculation (EVN). Evaporative cooling is most effective in dry climates. Mechanical coil cooling works by transferring heat from the air stream to a coolant. It can achieve lower temperature levels than evaporative cooling and also dehumidify the supply air. AbsolutAire offers direct-expansion (DX) and chilled-water (CW) coil cooling options to meet specific application needs. Committed to providing the Best Available Value in its advanced air-handling systems, AbsolutAire can engineer, integrate and deliver the solution for most any cooling and/or humidification requirement your customer demands. Evaporative Cooling: Water-saturated rigid cellulose is used for evaporative cooling and addition of humidity to the supply air from an air-handling system. AbsolutAire models are available in a wide range of capacities from less than 1,000 CFM to more than 130,000 CFM. Mechanical Cooling: DX or CW coils can be used for mechanical cooling of the supply air from an air-handling system. AbsolutAire models are available for single-unit, closed-loop systems and for multiple-unit, central-control systems. AbsolutAire is a registered trademark of AbsolutAire, Inc. 2

AbsolutAire Cooling Advantages Advanced Evaporative Cooling Low-Cost Cooling & Humidification High-Efficiency Wetted Media Wide Range of Features & Models Mechanical Cooling Excellence DX & CW System Choices Low Service Requirements Integrated All-Season Performance Wetted Media Evaporative Cooling: Nature s Air Conditioner Evaporative cooling is sometimes called nature s air conditioner. Just as a breeze across wet skin provides cooling as the moisture evaporates, an evaporative cooler does the same. It reduces the dry bulb or sensible air temperature to the wet bulb or saturated air temperature by evaporating water and adding humidity to the facility supply air. The process is effective, economical, environmentally friendly and healthy. With direct evaporative cooling, outside air is drawn through a water-saturated medium, usually cellulose, and cooled by evaporation. Direct evaporative cooling adds moisture to the air stream until the air volume is close to saturation. The dry bulb temperature is reduced, while the wet bulb temperature stays the same. Warm Air Fan Cool Air Water Recirculation Pump Sump Mechanical Cooling: Refrigerant or Chilled Water Mechanical cooling in an air-handling system can be provided by direct expansion (DX) coils with a refrigerant or by or chilled water (CW) coils. With relatively mild, ambient temperatures, the air-handling unit can efficiently provide cooling for a good portion of its operating cycle by varying the fan speeds or outside-return air blends. Both the dry-bulb temperature and the wet-bulb temperature are reduced when using mechanical cooling coils. With DX cooling, refrigerant flows through the evaporator coils to absorb heat, thus cooling and dehumidifying the air. A compressor moves the coolant through the coils and a condenser removes the absorbed heat for exhaust outside. Based on the project objectives, these may or may not be part of the AbsolutAire-supplied air-handling unit. With CW cooling, refrigeration equipment provides cold water, which is then pumped through coils in the air-handling unit to cool and dehumidify the air stream. To save energy, the flow can be modulated to provide dehumidification and reduced cooling. Pure and Simple Solutions 3

AbsolutAire Evaporative Cooling Evaporative cooling is the most economical alternative to chilled water (CW) or direct expansion (DX) cooling. When the site ambient conditions are right for the application, AbsolutAire evaporative cooling solutions offer low first cost, efficient operation, long-life performance and low maintenance expense. The Concept When warm air passes over cooler water, the water absorbs heat from the air and evaporates. Evaporative coolers use this concept to extract heat from outside air by passing it through a wetted media and cooling the building supply air. Two types of air temperature are involved: dry bulb and wet bulb. Air ambient or dry bulb temperature is measured with a thermometer. The air saturation or wet bulb temperature is the lowest temperature that can be reached by the air absorbing moisture. Saturation efficiency is when the dry bulb temperature of the leaving air is the same as the wet bulb temperature of the entering air. Dry Bulb vs. Wet Bulb Temperature Concepts AIR FLOW T Dry Bulb T Wet Bulb Wet T Dry Bulb WARM AIR Direct T Wet Bulb COOL AIR An evaporative cooler with 88% saturation efficiency will cool the air by 88% of the difference between the two air temperatures. For example, if the dry bulb temperature is 90 F and the wet bulb temperature is 70 F, this evaporative cooler can cool the air to about 72.4 F (90-70 = 20 X 0.88 = 17.6 and 90-17.6 = 72.4 ) Important Operating Formulas Air Flow Velocity = Feet per Minute = Evaporative Cooling EDBT LDBT Efficiency = 100% x EDBT WBT LDBT = EDBT CFM L x H Evaporative Media Performance Water Evaporation and Bleed-Off 1.2 x SCFM x (EDBT LDBT) Gallons per Hour Evaporated = 10,000 E% x (EDBT WBT) Cycles of Concentration = 100% Make-Up = Evaporations + Bleed-Off Abbreviations EDBT = Entering dry bulb temperature (before cooling pad) LDBT = Leaving dry bulb temperature (after cooling pad) WBT = Wet bulb temperature (same before and after the pad) Evaporation + Bleed-Off Bleed-Off SCFM = Standard cubic feet per minute of air L = Length of pad wall in feet H = Height of pad wall in feet Cooling effectiveness and pressure drop are impacted by the thickness of the wetted media and the air velocity. Cooling Effectiveness 100% 90% 80% 70% 60% 50% 24 18 12 8 6 4 Pressure Drop, WG 0.50 0.40 0.30 0.20 0.10 24 18 12 8 6 4 4 40% 100 200 300 400 500 600 700 800 Air Velocity, FPM 0.0 100 200 300 400 500 600 700 800 Air Velocity, FPM

Construction Features Evaporative cooling systems from AbsolutAire offer a wide range of standard features, as well as numerous options. These are shown for both EVR and EVN models. AbsolutAire EVR Evaporative Cooling (With Water Recirculation) AbsolutAire EVN Evaporative Cooling (Without Water Recirculation) STANDARD FEATURES w/ 1 Insulation Evaporative Media Evaporative Media OPTIONS Drift-Eliminator Mediae Evaporative Media Fiberglass Media; 6, 12 or 18 Evaporative Media Fiberglass Media; 6 or 12 CELdek, DRIFdek and GLASdek are registered trademarks of Munters Corporation. Good Practices Poor water quality and improper maintenance can cause problems including scale buildup, biological growth, and corrosion. These can foul the wetted media, reduce operating efficiency and service life, and degrade IAQ with objectionable odors and unhealthy microorganisms. Good system design and operating practices can minimize such problems. The primary approach is to provide sufficient water to the media to keep it completely wet and fully flushed. Good practices include using fresh clean water, de-ionized or municipal, not from open holding tanks or reverse-osmosis systems. Preventive measures may include chemical treatments, regular media flushing, adequate bleed-off for scale control, and fresh makeup water to replace evaporated water. Our fan-run timer option allows the fan to continue running for a pre-set time (field adjustable) to ensure the media is dry. Pure and Simple Solutions 5

Evaporative Cooling: Capacities, Dimensions & Selection Evaporative cooling solutions from AbsolutAire deliver economical, effective cooling and/or humidification for a wide range of industrial and commercial applications. EVR models provide maximum cooling and humidity utilizing a pump and a closed-loop, water recirculation system. EVN models provide similar cooling, but without water recirculation, and provide for reduced up-front costs, a simplified design and lower maintenance. Model selection is unique to specific application requirements. AbsolutAire EVN Evaporative Cooling CFM Range Dimensions, Inches Pipe Dia., In. *Sq Ft of Evap Media Model Min. Max. Used with Units A B C D E F G H J (6 or 12 ) M1 23 21 12 M2 28 24 12 M3 35 27 18 M4 43 30 18 M5 48 35 24 M6 55 46 24 30 28 28 26 1/2 1 4.00 38 30 35 32 1/2 1 5.78 46 37 43 32 1/2 1 9.17 54 44 53 38 1/2 1-1/2 13.33 66 52 63 46 1/2 1-1/2 20.00 66 64 63 58 1/2 1-1/2 25.00 Notes: per minute (FPM) Transition Section EVN Section EVN Inlet Hood (transition required only on M1-M6) C 30" G 15" 6 3/8" D * 1 2 A D D Air flow F Transition Section Dropout Access Door EVN Section H (fill) J (drain) PLAN VIEW 4 3/8" Evaporative Media 6" Standard (12" optional) Controls Side D Opposite Side B E E Air flow E E E 6 Optional Inlet Damper CONTROLS SIDE VIEW Optional Filters (side access) Optional Filters (dropout rack) Water Distribution H (fill) J (drain) Piping with Nozzles EVN SECTION INLET VIEW

AbsolutAire EVR Evaporative Cooling CFM Range Dimensions, Inches Pipe Dia., In. **6 Media (28 EVR) **12 Media (34 EVR) **18 Media (40 EVR) *Sq Ft of Pump Max *Sq Ft of Pump Max *Sq Ft of Pump Max Model Min. Max. A B C D E F G H Media HP GPM Media HP GPM Media HP GPM Transition & EVR Section Options Section EVR Inlet Hood D **28" **6" 15" E EVR Piping Detail Unit Width Air Flow A H (over-flow) F (fill) G (bleed) G (drain) Sump Tank Hinged Access Door PLAN VIEW Dropout Access Door Transition EVR Section Optional Filters (side access) Optional Inlet Damper or Louver Controls Side A Pitched Roof (EVR4 - EVR21) Opposite Side Unit Height Air Flow B B C See EVR Piping Detail Evaporative Media CONTROLS SIDE VIEW Optional Filters EVR Piping Pitched Sump Tank EVR SECTION INLET VIEW Pure and Simple Solutions 7

AbsolutAire Mechanical Coil Cooling Some applications require temperature and humidity levels lower than evaporative cooling can provide. In such cases, AbsolutAire can provide mechanical cooling options. These systems cost more than evaporative cooling because added equipment is needed such as chillers, condensers and compressors. Direct Expansion (DX) cooling is the usual choice for smaller systems, while Chilled Water (CW) cooling is the choice for larger tonnage systems. Both types of cooling systems reduce the dry bulb temperature and wet bulb temperature. Direct Expansion (DX) Coils Direct expansion evaporator coils offer single, dual or quad circuits to ensure precise control of cooling capacity on AbsolutAire units. Interlaced circuiting as well as face or run control options ensure uniform refrigerant distribution over the face of the coil. Wide fin spacing is available to reduce frost buildup on low-temperature applications. Many options are available. These include special coil coatings, such as phenolic or urethane; special coil construction, such as copper fins, stainless steel, thicker fins or tubes; a choice of different refrigerants; and other features to meet requirements. Chilled Water (CW) Coils Chilled water coils are a common choice for low-cost cooling and dehumidification on AbsolutAire units. These coils are typically available in a range of sizes and circuiting selections to optimize heat-transfer capacities. The design and selection process ensures easy cleaning for lasting performance. Glycol is sometimes used as the cooling fluid. Construction Features Mechanical coil cooling systems from AbsolutAire offer a wide range of standard features, as well as numerous options. These include: Good Practices Mechanical cooling coils perform their heat-transfer functions in extremely hostile environments, which may degrade performance as well as shorten coil life. Regular cleaning and adjustments are recommended to prevent dirt from accumulating and moisture causing corrosion. Upstream filters must be maintained as specified. Other good practices include: STANDARD FEATURES OPTIONS which is biologically active and may cause IAQ problems. 8

AbsolutAire CB Mechanical Cooling Dimensions, Inches *E Coil Data CFM Range Quantity of Rows in Coil Qty of FH (Max) FL (Max) Model Min. Max. A B C D 1 5 6 or 8 10 or 12 F (dia.) G Coils Fin Height Fin Length *Once the factory performs the coil selection, the CB section length (dim. E) is determined by the quantity of rows in coil(s). F (Drain) Unit Width Hinged Access Door Transition & CB Section Options Section CB Inlet Hood D * E Access Patch FL Coil Connections 15" PLAN VIEW Dropout Access Door G Air Flow A * Consult factory representative for DX or CW coil selection * Coil connections are standard as shown - opposite side connections are available * Drain piping is standard as shown - opposite side, floor, or special drain locations are available * - upright, and special configurations are available * Split system configuration shown - packaged systems, including condensing units, are available - consult factory representative for proper selection A Transition CB Section Optional Filters (Side Access) Optional Inlet Damper or Louver Controls Side FL Pitched Roof (CB5 - CB20) Opposite Side Unit Height FH Air Flow B B FH C DX or CW Coil CONTROLS SIDE VIEW Optional Filters Pitched Drain Pan CB SECTION INLET VIEW F (Drain) Pure and Simple Solutions 9

AbsolutAire Cooling Solutions Direct Expansion (DX) Cooling: Worthington Trailer Montoursville, PA Direct Expansion (DX) Cooling: Toyota Fork Lift Columbus, IN Chilled Water (CW) Cooling: Caterpillar Lafayette, IN 10

EVR Evaporative Cooling: Johns Manville Scottsboro, AL EVR Evaporative Cooling: Metalsa Corporation Monterrey, Mexico EVR Evaporative Cooling: Federal Mogul Lake City, MN Pure and Simple Solutions 11

Other Pure and Simple Solutions: E-Series Direct-Fired Air Turnover S-Series Air-Handling Systems Spray & Bake Paint-Booth Heating Systems CH, DH & APD Heaters & Air-Process Dryers LX1 Direct Digital Control (DDC) System Represented by: 05/09 www.absolutaire.com